HomeMy WebLinkAboutB17-0092_A-000.1_1498849020.pdfPWS_MET2A
X-###
1 Ref
1 Ref
1
Ref
1 Ref
STANDARD ABBREVIATIONS LEGEND GENERAL NOTES
1. IF DISCREPANCIES OCCUR BETWEEN DRAWINGS OR BETWEEN THE
DRAWINGS AND THE SPECIFICATIONS, SUBMIT AN RFI FOR RESOLUTION.
2. DO NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS GOVERN. DETAILS
SHOWN CLOSER TO ACTUAL SCALE GOVERN OVER LARGER SCALE DETAILS.
IF CRITICAL DIMENSIONS DO NOT APPEAR ON CONSTRUCTION DOCUMENTS,
NOTIFY THE ARCHITECT IN WRITING FOR RESOLUTION. SUBMIT AN RFI IF
CRITICAL DIMENSIONS DO NOT APPEAR ON THE DRAWINGS.
3. THE BUILDING EXTERIOR IS DEFINED BASED ON A SYSTEMS METHODOLOGY.
REFER TO A-700 DRAWING SERIES FOR COMPONENTS THAT COMPRISE EACH
SYSTEM.
4. PROVIDE ISOLATION BETWEEN ALL DISSIMILAR METALS WHERE THEY OCCUR
TO PREVENT ELECTROLYTIC REACTION AND CORROSION.
5. VERIFY EQUIPMENT ROUGH-IN DIMENSIONS WITH MANUFACTURER FOR
EQUIPMENT THAT IS EXISTING, REUSED, OR FURNISHED BY OWNER.
6. ALL PLAN DIMENSIONS LOCATING DOOR ASSEMBLIES IN INTERIOR GYPSUM
BOARD PARTITIONING ARE TO EDGE OF DOOR, UNLESS NOTED OTHERWISE.C
7. ALL PLAN DIMENSIONS LOCATING DOOR ASSEMBLIES IN INTERIOR GYPSUM
BOARD PARTITIONING ARE TO EDGE OF DOOR, UNLESS NOTED OTHERWISE.
8. ANY FINISH INDICATED FOR A PARTICULAR INTERIOR WALL MEANS THAT THE
ENTIRE UNINTERRUPTED LENGTH OF THE WALL IS TO BE FINISHED AS
INDICATED UNLESS SHOWN OR NOTED OTHERWISE.
9. THE PRESENCE OF THE ARCHITECT OR AN ARCHITECT'S REPRESENTATIVE ON
THE JOB SITE DOES NOT IMPLY CONCURRENCE OR APPROVAL OF THE WORK.
THE CONTRACTOR SHALL CALL SPECIFIC ITEMS TO THE ATTENTION OF THE
ARCHITECT IF THE CONTRACTOR WISHES TO OBTAIN THE ARCHITECT'S
APPROVAL.
ALIGN
MAXIMUM
MINIMUM
TYPICAL
SIMILAR
TO ACCURATELY LOCATE FACE BASED ON ADJACENT ITEMS OR
CONSTRUCTION
THE CONDITION MAY NOT VARY TO A DIMENSION GREATER THAN THAT
SHOWN WITHOUT THE APPROVAL OF THE ARCHITECT
THE CONDITION MAY NOT VARY TO A DIMENSION SMALLER THAN THAT
SHOWN WITHOUT THE APPROVAL OF THE ARCHITECT
THE CONDITION APPLIES TO SAME CONDITIONS THROUGHOUT UNLESS
NOTED OTHERWISE
THE CONDITION IS THE SAME OR REPRESENTATIVE FOR ALL SIMILAR
CONDITIONS, UNLESS NOTED OTHERWISE. ACTUAL CONDITIONS MAY VARY,
BUT DO NOT REVOKE THE INTENT OF THE CONFIGURATION INDICATED.
DETAILS ARE USUALLY KEYED AND NOTED "SIMILAR" ONLY ONCE WITH THE
FIRST OCCURRENCE AND ARE REPRESENTATIVE FOR ALL SIMILAR
CONDITIONS THROUGHOUT, UNLESS NOTED OTHERWISE.
DEFINITIONS
#
X-###
SIM
WALL SECTION
REFERENCE
EXTERIOR ELEVATION
REFERENCE
DIMENSION LINE
DOOR TAG
CENTERLINE
ROOM TAG
ROOM NAME
####
#
GRID LABEL - NEW
ELEVATION LABEL
INTERIOR ELEVATION
REFERENCE
8' - 2"
AREA TAG AREA NAME
150 SF
INTERIOR PARTITION
TYPE TAG
STOREFRONT TAG
NORTH ARROW
0' 2' 4' 8' 16'
SCALE: 1/4" = 1'-0"
GRAPHIC SCALE
#
X-###
SIM BUILDING SECTION
REFERENCE
#
X-###
SIM
SPOT ELEVATION
X-###
#
TYP.
REVISION CLOUD
AND TAG
100'-0"
DETAIL CALLOUT
DETAIL ELEVATION
REFERENCE
CEILING HEIGHT TAG
CURTAIN WALL TAG
EXTERIOR SYSTEM TAG
X-###
# #
#
#
1' - 0"
####X
#
X-###
X#x
VIEW REFERENCE
/ # X-###
DETAIL NUMBERING
BATTLESHIP GRID ORDER
A
B
C
D
E
1 2 3 4 5 6
XX#
FINISH TAG
KEYNOTE AND LEADER-
TYPE 1
HATCHED DETAIL
LOCATION WOULD BE
NUMBERED "A2" ON
THE DETAIL SHEET
F15
07 2700 - SHEET
WATERPROOFING
KEYNOTE AND LEADER-
TYPE 2
WINDOW TAG
GRID LABEL - EXISTING #
ARCHITECTURAL SYMBOLS LEGEND
W#
C#
S#
1
NORTH
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:35:01 PM
15924.00
A-000.1
ABBREVIATIONS &
SYMBOLS
2017
03/10/17
PERMIT
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
NOTE: FOR ADDITIONAL ABBREVATIONS; REFER TO SPECIFICATION 01 4200 FOR
COMPLETE INDUSTRY STANDARD ABBREVIATION LIST
A
ACT ACOUSTICAL CEILING TILE
ADD ADDENDUM
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE(LY)
ARCH ARCHITECT or ARCHITECTURAL
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS
AUX AUXILIARY
B
BLDG BUILDING
BSMT BASEMENT
BTWN BETWEEN
C
CD CONSTRUCTION DOCUMENTS or CONTRACT DOCUMENTS
CJ CONSTRUCTION JOINT or CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CORR CORRIDOR
D
DBL DOUBLE
DEMO DEMOLISH or DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION or DIMENSIONAL
DW DISHWASHER
DWG DRAWING
E
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMER EMERGENCY
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
F
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FURNITURE, FIXTURES AND EQUIPMENT
FHC FIRE HOSE CABINET
G
GA GAUGE
GALV GALVANIZED
H
HB HOSE BIBB
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION and AIR CONDITIONING
I
IBC INTERNATIONAL BUILDING CODE
J
JAN JANITOR
JT JOINT
L
L ANGLE
M
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL and PLUMBING
MEZZ MEZZANINE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O
OC ON-CENTER
OPNG OPENING
OPP OPPOSITE
P
PERIM PERIMETER
PR PAIR or PROPOSAL REQUEST
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT(ED), POST-TENSIONED SLAB or PRESSURE TREATED
Q
QTY QUANTITY
R
R RADIUS, RISER or THERMAL RESISTANCE
RCP REFLECTED CEILING PLAN
RD ROAD or ROOF DRAIN
RE REFER TO or REFERENCE
REV REVISE, REVISED or REVISION
RM ROOM
RO ROUGH OPENING
ROW RIGHT-OF-WAY
RTU ROOFTOP UNIT
S
SAN SANITARY
SF SQUARE FOOT (FEET)
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
STC SOUND TRANSMISSION CLASS
STL STEEL
STOR STORAGE
T
TO TOP OF
TOC TOP OF CONCRETE
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
V
VIF VERIFY IN FIELD
W
W/ WITH
W/O WITHOUT
WD WOOD
WP WORKING POINT
WT WEIGHT
06/30/17