Loading...
HomeMy WebLinkAboutB17-0092_A-000.1_1498849020.pdfPWS_MET2A X-### 1 Ref 1 Ref 1 Ref 1 Ref STANDARD ABBREVIATIONS LEGEND GENERAL NOTES 1. IF DISCREPANCIES OCCUR BETWEEN DRAWINGS OR BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, SUBMIT AN RFI FOR RESOLUTION. 2. DO NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS GOVERN. DETAILS SHOWN CLOSER TO ACTUAL SCALE GOVERN OVER LARGER SCALE DETAILS. IF CRITICAL DIMENSIONS DO NOT APPEAR ON CONSTRUCTION DOCUMENTS, NOTIFY THE ARCHITECT IN WRITING FOR RESOLUTION. SUBMIT AN RFI IF CRITICAL DIMENSIONS DO NOT APPEAR ON THE DRAWINGS. 3. THE BUILDING EXTERIOR IS DEFINED BASED ON A SYSTEMS METHODOLOGY. REFER TO A-700 DRAWING SERIES FOR COMPONENTS THAT COMPRISE EACH SYSTEM. 4. PROVIDE ISOLATION BETWEEN ALL DISSIMILAR METALS WHERE THEY OCCUR TO PREVENT ELECTROLYTIC REACTION AND CORROSION. 5. VERIFY EQUIPMENT ROUGH-IN DIMENSIONS WITH MANUFACTURER FOR EQUIPMENT THAT IS EXISTING, REUSED, OR FURNISHED BY OWNER. 6. ALL PLAN DIMENSIONS LOCATING DOOR ASSEMBLIES IN INTERIOR GYPSUM BOARD PARTITIONING ARE TO EDGE OF DOOR, UNLESS NOTED OTHERWISE.C 7. ALL PLAN DIMENSIONS LOCATING DOOR ASSEMBLIES IN INTERIOR GYPSUM BOARD PARTITIONING ARE TO EDGE OF DOOR, UNLESS NOTED OTHERWISE. 8. ANY FINISH INDICATED FOR A PARTICULAR INTERIOR WALL MEANS THAT THE ENTIRE UNINTERRUPTED LENGTH OF THE WALL IS TO BE FINISHED AS INDICATED UNLESS SHOWN OR NOTED OTHERWISE. 9. THE PRESENCE OF THE ARCHITECT OR AN ARCHITECT'S REPRESENTATIVE ON THE JOB SITE DOES NOT IMPLY CONCURRENCE OR APPROVAL OF THE WORK. THE CONTRACTOR SHALL CALL SPECIFIC ITEMS TO THE ATTENTION OF THE ARCHITECT IF THE CONTRACTOR WISHES TO OBTAIN THE ARCHITECT'S APPROVAL. ALIGN MAXIMUM MINIMUM TYPICAL SIMILAR TO ACCURATELY LOCATE FACE BASED ON ADJACENT ITEMS OR CONSTRUCTION THE CONDITION MAY NOT VARY TO A DIMENSION GREATER THAN THAT SHOWN WITHOUT THE APPROVAL OF THE ARCHITECT THE CONDITION MAY NOT VARY TO A DIMENSION SMALLER THAN THAT SHOWN WITHOUT THE APPROVAL OF THE ARCHITECT THE CONDITION APPLIES TO SAME CONDITIONS THROUGHOUT UNLESS NOTED OTHERWISE THE CONDITION IS THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS, UNLESS NOTED OTHERWISE. ACTUAL CONDITIONS MAY VARY, BUT DO NOT REVOKE THE INTENT OF THE CONFIGURATION INDICATED. DETAILS ARE USUALLY KEYED AND NOTED "SIMILAR" ONLY ONCE WITH THE FIRST OCCURRENCE AND ARE REPRESENTATIVE FOR ALL SIMILAR CONDITIONS THROUGHOUT, UNLESS NOTED OTHERWISE. DEFINITIONS # X-### SIM WALL SECTION REFERENCE EXTERIOR ELEVATION REFERENCE DIMENSION LINE DOOR TAG CENTERLINE ROOM TAG ROOM NAME #### # GRID LABEL - NEW ELEVATION LABEL INTERIOR ELEVATION REFERENCE 8' - 2" AREA TAG AREA NAME 150 SF INTERIOR PARTITION TYPE TAG STOREFRONT TAG NORTH ARROW 0' 2' 4' 8' 16' SCALE: 1/4" = 1'-0" GRAPHIC SCALE # X-### SIM BUILDING SECTION REFERENCE # X-### SIM SPOT ELEVATION X-### # TYP. REVISION CLOUD AND TAG 100'-0" DETAIL CALLOUT DETAIL ELEVATION REFERENCE CEILING HEIGHT TAG CURTAIN WALL TAG EXTERIOR SYSTEM TAG X-### # # # # 1' - 0" ####X # X-### X#x VIEW REFERENCE / # X-### DETAIL NUMBERING BATTLESHIP GRID ORDER A B C D E 1 2 3 4 5 6 XX# FINISH TAG KEYNOTE AND LEADER- TYPE 1 HATCHED DETAIL LOCATION WOULD BE NUMBERED "A2" ON THE DETAIL SHEET F15 07 2700 - SHEET WATERPROOFING KEYNOTE AND LEADER- TYPE 2 WINDOW TAG GRID LABEL - EXISTING # ARCHITECTURAL SYMBOLS LEGEND W# C# S# 1 NORTH 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 3:35:01 PM 15924.00 A-000.1 ABBREVIATIONS & SYMBOLS 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 NOTE: FOR ADDITIONAL ABBREVATIONS; REFER TO SPECIFICATION 01 4200 FOR COMPLETE INDUSTRY STANDARD ABBREVIATION LIST A ACT ACOUSTICAL CEILING TILE ADD ADDENDUM AFF ABOVE FINISHED FLOOR ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE(LY) ARCH ARCHITECT or ARCHITECTURAL ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS AUX AUXILIARY B BLDG BUILDING BSMT BASEMENT BTWN BETWEEN C CD CONSTRUCTION DOCUMENTS or CONTRACT DOCUMENTS CJ CONSTRUCTION JOINT or CONTROL JOINT CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT CONC CONCRETE CORR CORRIDOR D DBL DOUBLE DEMO DEMOLISH or DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION or DIMENSIONAL DW DISHWASHER DWG DRAWING E EA EACH EJ EXPANSION JOINT ELEC ELECTRIC(AL) ELEV ELEVATOR EMER EMERGENCY EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EXIST EXISTING F FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FFE FURNITURE, FIXTURES AND EQUIPMENT FHC FIRE HOSE CABINET G GA GAUGE GALV GALVANIZED H HB HOSE BIBB HORIZ HORIZONTAL HT HEIGHT HVAC HEATING, VENTILATION and AIR CONDITIONING I IBC INTERNATIONAL BUILDING CODE J JAN JANITOR JT JOINT L L ANGLE M MAX MAXIMUM MECH MECHANICAL MEP MECHANICAL, ELECTRICAL and PLUMBING MEZZ MEZZANINE MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING N NA NOT APPLICABLE NIC NOT IN CONTRACT NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE O OC ON-CENTER OPNG OPENING OPP OPPOSITE P PERIM PERIMETER PR PAIR or PROPOSAL REQUEST PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PAINT(ED), POST-TENSIONED SLAB or PRESSURE TREATED Q QTY QUANTITY R R RADIUS, RISER or THERMAL RESISTANCE RCP REFLECTED CEILING PLAN RD ROAD or ROOF DRAIN RE REFER TO or REFERENCE REV REVISE, REVISED or REVISION RM ROOM RO ROUGH OPENING ROW RIGHT-OF-WAY RTU ROOFTOP UNIT S SAN SANITARY SF SQUARE FOOT (FEET) SHT SHEET SIM SIMILAR SPEC SPECIFICATION(S) SQ SQUARE STC SOUND TRANSMISSION CLASS STL STEEL STOR STORAGE T TO TOP OF TOC TOP OF CONCRETE TOP TOP OF PARAPET TOS TOP OF STEEL TOW TOP OF WALL TYP TYPICAL U UNO UNLESS NOTED OTHERWISE V VIF VERIFY IN FIELD W W/ WITH W/O WITHOUT WD WOOD WP WORKING POINT WT WEIGHT 06/30/17