HomeMy WebLinkAboutB17-0092_A-101.1_1508947723.pdfUP
A-101A.1
A1
A-101B.1
A3
5e86 6e86 7e86 8e86
LEGEND
EXISTING TO
REMAIN
NEW WALL
EXISTING TO BE
REMOVED
REGION INDICATES AREA
NOT IN SCOPE
KEYNOTE LEGEND
KEY PLAN
GENERAL NOTES
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR
CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL
SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P
COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE
SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND
OBTAINING AN APPROVED METHOD OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY
CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH
EXISTING CONDITION.
PROVIDE CORNER OR WALL GUARDS PER FINISH PLANS.
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL
EQUIPMENT AHEAD OF DEMOLITION WORK.
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE UNLESS
APPROVED IN WRITING BY THE OWNER ON A CASE-BY-CASE BASIS.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION
AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION,
INCLUDING BUT NOT LIMITED TO CORING AND TRENCHING.
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE
LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES
OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO
NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED
INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE
WALL.
STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL WING RENOVATION
8/11/2017 4:35:56 PM15924.00
A-101.1
OVERALL FLOOR PLAN -
LEVEL 1
2017
07/11/17PERMIT
RESUBMISSION
VAIL VALLEY
MEDICAL
CENTER
180 S. Frontage
Road West,
Vail, CO 81657 1/16" = 1'-0"A1 OVERALL FLOOR PLAN - LEVEL 1
A
B
C
D
E
NORTH
ADDENDUM 1 05/23/17 1
ADDENDUM 3 06/27/17 2
ASI 02 08/11/17 3
3
3
3
3
10/25/17