HomeMy WebLinkAboutB17-0092_A-101A.1_1503950485.pdfOFFICE
106
OFFICE
114
OFFICE
119
OFFICE
122
CONFERENCE
ROOM
123
OFFICE
116A
OFFICE
121
OFFICE
117B
OFFICE
112
OFFICE
111
TLT
104
RECEPTION
102
BREAK
127
OFFICE
126
CORRIDOR
100B
HOT LAB
104B
NUCLEAR
MEDICINE
CAMERA
105A
CONTROL
104A
STORAGE
108
SPRINKLER ROOM
106A
CORRIDOR
118
A-401A.2 D4
D2
B5
A-300.1
A5
A-300.1
112
111
108
101
105A
104B
128A
A-401A.2
A-401A.2
C2
A-401A.2
B1
D5
C1
C4
B3 B2
128C
F20
F20105D
COPY
125
104A
100
INJECTION
104D
A-401A.2
A1
A4
A3
A5
A-401A.1
D3
126 116B
F32
A-401A.2 D1
A-401A.1
A1
A-401A.2E2
E1
E3
STORAGE
118A 118A
XX118B
100A
COPIER
A-401A.2
C5
A5
A-320.1
114
STORAGE
127A
CORRIDOR
100
STAFF RECESS
101
OFFICE
128B
OFFICE
128A
116A
F20
F37
W1
OFFICE
128C
128B
(E) STORAGE
F32
F32
F80
EQ EQ
EQ EQ 102
CLOSET
100A
F20
F98
F99
F99
F99
F99 F99
ESR / SOILED
HOLD
104E
PT TOILET
104C
104C
104E
1
D1
D2
A-401A.2
B1 A-401A.1
B5
CLEAN STORAGE
130
STORAGE
131
1
CORRIDOR
03
131B 130B
131A
130A
1
F101
F101
F101
F101
F101
A-740.1
B2
F103 F103 F103 XX132
A-401A.2A6
1
F103
F103
OFFICE
117C
117C
117B
122
121
OFFICE/RECEPT
117A
CORRIDOR
01
B1
A-550.1
4
119
117A
CORRIDOR
02
4 104
A2
A-740.1
SIM A2
A-740.1
SIM
A2
A-740.1
SIM A2
A-740.1
SIM
A2
A-740.1
SIM
OPP
HAND
4
A-740.1
B1
4
4
4
F99
F101
F101
4
4
127
127A
102B
102A
123
106
4
4
4
LEGEND
EXISTING TO
REMAIN
NEW WALL
EXISTING TO BE
REMOVED
REGION INDICATES AREA
NOT IN SCOPE
KEYNOTE LEGEND
KEY PLAN
GENERAL NOTES
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR
CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL
SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P
COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE
SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND
OBTAINING AN APPROVED METHOD OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY
CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH
EXISTING CONDITION.
PROVIDE CORNER OR WALL GUARDS PER FINISH PLANS.
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL
EQUIPMENT AHEAD OF DEMOLITION WORK.
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE UNLESS
APPROVED IN WRITING BY THE OWNER ON A CASE-BY-CASE BASIS.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION
AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION,
INCLUDING BUT NOT LIMITED TO CORING AND TRENCHING.
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE
LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES
OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO
NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED
INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE
WALL.
STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
PROGRESS PRINTS
NOT FOR
CONSTRUCTION
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
7/11/2017
10:23:22 AM
7/11/2017 10:23:22 AM
15924.00
A-101A.1
ENLARGED ANNOTATION
FLOOR PLAN - AREA A
2017
07/11/17
PERMIT
RESUBMISSION
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1/4" = 1'-0"
A1
ENLARGED ANNOTATION FLOOR PLAN AREA A
F20 REFINISH NEW OR WALLS DAMAGED BY THIS SCOPE OF WORK
TO MATCH EXISTING ADJACENT WALLS WITHIN THE SPACE
F32 MONITOR AND BRACKET; MATCH HEIGHT OF EXISTING
LOCATION, OFCI. GC TO PROVIDE FRAMING WITHIN WALL.
F37 PROTECT AND MAINTAIN WINDOW
F80 NORTH OF THIS LINE IS NEW FLOORING. SOUTH OF THIS LINE IS
EXISTING TO REMAIN, WITH ALTERNATE FOR NEW.
F99 GROMMET IN COUNTERTOP; PROVIDE COUNT AS SHOWN - GC
TO COORDINATE FINAL LOCATION WITH OWNER
F101 PROVIDE THE FOLLOWING: 1. FILL WALL CAVITIES WITH
ACOUSTIC SAFB SOUND BATTS. 2. SEAL ALL PENETRATIONS
WITH ACOUSTIC RATED SEALANT AT ALL JOINTS AND DEVICES.
3. PROVIDE ACOUSTIC PUTTY BEHIND EACH WALL DEVICE BACK
BOX. 4. WHERE NOT POSSIBLE FOR WALLS TO EXTEND TO DECK,
PROVIDE 48" OF 6" THICK SAFB SOUND BATTS IN EACH
DIRECTION HORIZONTALLY ABOVE THE CEILINGS. 5. WHERE NOT
FULLY DUCTED, PROVIDE BOOT TYPE DUCTWORK
CONFIGURATION AT RETURN DUCTS TO REDUCE THE PASSAGE
OF SOUND. 6. AT DOORS WITHOUT PERIMETER GASKETS,
PROVIDE PERIMETER GASKETING TO ALL NON-GASKETED
DOORS.
F103 08 8113 - DECORATIVE WINDOW FILM; "LLUMAR BRONZE NRMB
PS2" OR SIM. ON BACK SIDE OF GLASS
A
B
C
D
E
NORTH
1
1
1
1
1
1
1
1
1
1
1
4
4
4
4
4
4
4
4
4
ADDENDUM 1 05/23/17 1
RFC0005 06/09/17 2
RFC0008 06/20/17 3
ADDENDUM 3 06/27/17 4
08/28/17