Loading...
HomeMy WebLinkAboutB17-0092_A-101A.1_1503950485.pdfOFFICE 106 OFFICE 114 OFFICE 119 OFFICE 122 CONFERENCE ROOM 123 OFFICE 116A OFFICE 121 OFFICE 117B OFFICE 112 OFFICE 111 TLT 104 RECEPTION 102 BREAK 127 OFFICE 126 CORRIDOR 100B HOT LAB 104B NUCLEAR MEDICINE CAMERA 105A CONTROL 104A STORAGE 108 SPRINKLER ROOM 106A CORRIDOR 118 A-401A.2 D4 D2 B5 A-300.1 A5 A-300.1 112 111 108 101 105A 104B 128A A-401A.2 A-401A.2 C2 A-401A.2 B1 D5 C1 C4 B3 B2 128C F20 F20105D COPY 125 104A 100 INJECTION 104D A-401A.2 A1 A4 A3 A5 A-401A.1 D3 126 116B F32 A-401A.2 D1 A-401A.1 A1 A-401A.2E2 E1 E3 STORAGE 118A 118A XX118B 100A COPIER A-401A.2 C5 A5 A-320.1 114 STORAGE 127A CORRIDOR 100 STAFF RECESS 101 OFFICE 128B OFFICE 128A 116A F20 F37 W1 OFFICE 128C 128B (E) STORAGE F32 F32 F80 EQ EQ EQ EQ 102 CLOSET 100A F20 F98 F99 F99 F99 F99 F99 ESR / SOILED HOLD 104E PT TOILET 104C 104C 104E 1 D1 D2 A-401A.2 B1 A-401A.1 B5 CLEAN STORAGE 130 STORAGE 131 1 CORRIDOR 03 131B 130B 131A 130A 1 F101 F101 F101 F101 F101 A-740.1 B2 F103 F103 F103 XX132 A-401A.2A6 1 F103 F103 OFFICE 117C 117C 117B 122 121 OFFICE/RECEPT 117A CORRIDOR 01 B1 A-550.1 4 119 117A CORRIDOR 02 4 104 A2 A-740.1 SIM A2 A-740.1 SIM A2 A-740.1 SIM A2 A-740.1 SIM A2 A-740.1 SIM OPP HAND 4 A-740.1 B1 4 4 4 F99 F101 F101 4 4 127 127A 102B 102A 123 106 4 4 4 LEGEND EXISTING TO REMAIN NEW WALL EXISTING TO BE REMOVED REGION INDICATES AREA NOT IN SCOPE KEYNOTE LEGEND KEY PLAN GENERAL NOTES EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITION. PROVIDE CORNER OR WALL GUARDS PER FINISH PLANS. ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL EQUIPMENT AHEAD OF DEMOLITION WORK. PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE UNLESS APPROVED IN WRITING BY THE OWNER ON A CASE-BY-CASE BASIS. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING AND TRENCHING. PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS. WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL. STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver PROGRESS PRINTS NOT FOR CONSTRUCTION 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:23:22 AM 7/11/2017 10:23:22 AM 15924.00 A-101A.1 ENLARGED ANNOTATION FLOOR PLAN - AREA A 2017 07/11/17 PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/4" = 1'-0" A1 ENLARGED ANNOTATION FLOOR PLAN AREA A F20 REFINISH NEW OR WALLS DAMAGED BY THIS SCOPE OF WORK TO MATCH EXISTING ADJACENT WALLS WITHIN THE SPACE F32 MONITOR AND BRACKET; MATCH HEIGHT OF EXISTING LOCATION, OFCI. GC TO PROVIDE FRAMING WITHIN WALL. F37 PROTECT AND MAINTAIN WINDOW F80 NORTH OF THIS LINE IS NEW FLOORING. SOUTH OF THIS LINE IS EXISTING TO REMAIN, WITH ALTERNATE FOR NEW. F99 GROMMET IN COUNTERTOP; PROVIDE COUNT AS SHOWN - GC TO COORDINATE FINAL LOCATION WITH OWNER F101 PROVIDE THE FOLLOWING: 1. FILL WALL CAVITIES WITH ACOUSTIC SAFB SOUND BATTS. 2. SEAL ALL PENETRATIONS WITH ACOUSTIC RATED SEALANT AT ALL JOINTS AND DEVICES. 3. PROVIDE ACOUSTIC PUTTY BEHIND EACH WALL DEVICE BACK BOX. 4. WHERE NOT POSSIBLE FOR WALLS TO EXTEND TO DECK, PROVIDE 48" OF 6" THICK SAFB SOUND BATTS IN EACH DIRECTION HORIZONTALLY ABOVE THE CEILINGS. 5. WHERE NOT FULLY DUCTED, PROVIDE BOOT TYPE DUCTWORK CONFIGURATION AT RETURN DUCTS TO REDUCE THE PASSAGE OF SOUND. 6. AT DOORS WITHOUT PERIMETER GASKETS, PROVIDE PERIMETER GASKETING TO ALL NON-GASKETED DOORS. F103 08 8113 - DECORATIVE WINDOW FILM; "LLUMAR BRONZE NRMB PS2" OR SIM. ON BACK SIDE OF GLASS A B C D E NORTH 1 1 1 1 1 1 1 1 1 1 1 4 4 4 4 4 4 4 4 4 ADDENDUM 1 05/23/17 1 RFC0005 06/09/17 2 RFC0008 06/20/17 3 ADDENDUM 3 06/27/17 4 08/28/17