HomeMy WebLinkAboutB17-0092_A-101A.2_1503950486.pdfOFFICE 106 OFFICE 114 OFFICE 119 OFFICE 122 CONFERENCE ROOM 123 OFFICE 116A OFFICE 121 OFFICE 117B OFFICE 112 OFFICE 111 TLT 104 RECEPTION 102 BREAK 127 OFFICE 126 CORRIDOR 100B HOT LAB 104B NUCLEAR MEDICINE CAMERA 105A CONTROL 104A STORAGE 108 SPRINKLER ROOM 106A CORRIDOR 118 ALIGN ALIGN CLEAR 4' - 9" ALIGN ALIGN CLEAR 5' - 0" 9' - 10" ALIGN D0s D0sX D0b D0b D0s D0s D0s D0s D0s D0s D0s D0s D0b D0sXD0sX D0f D0s D0s D0bX D0s D0b D0sX D0s D0b STORAGE 127A 2' - 8" D0s D0s D0b D0b D0b D0b D0b D0bD0b ? ALIGN INJECTION 104D D0sX 1' - 9" 1' - 5" 4' - 10" 9" 1' - 4" 4' - 11" D0sX D0a 2' - 6" OFFICE 128A CORRIDOR 100 OFFICE 128B STAFF RECESS 101 ALIGN 1' - 0" D0f ALIGN D0f ALIGN D0sX COPY 125 ALIGN ALIGN ALIG ALIGN ALIGN ALIGN ALIG ALIG 3" 2' - 8" 10' - 11" 2' - 4" D0b 9' - 4" EQ EQ CL 1' - 7 1/8" 1' - 8 7/8" 3' - 10 1/4" 2' - 3 3/4" 30" CLEAR 6" 8' - 3 3/4" D0s D0s ALIGN ALIGN ALIG ALIGN ALIGN D0s D0s D0s F51 D0b 7' - 0" 8' - 4 7/8" 9' - 2 3/8" 3' - 5" D0b EQ EQ EQ EQ F32 F32 ALIGN ALIGN ALIG ALIGN 3' - 6" 3' - 2" 5' - 11" (E) STORAGE 120Z ALIGN D0sX ALIGN 6' - 6 3/4" ALIGN 44" MIN. CLEAR 44" MIN. CLEAR F26 F26 ALIGN 3' - 10" CLOSET 100A CLEAR 2' - 3 3/4" OFFICE 128C 1 CLEAN STORAGE 130 STORAGE 131 ALIGN 5'-0" CLR MIN 5' - 5 1/4" 3' - 0" 1 1 PT TOILET 104C ESR / SOILED HOLD 104E D0sX F101 F101 F101 F101 F101 F101 D0sX F101 D1b D1b J1b J1b 1 7' - 6" CLEAR 7' - 6" CLEAR ALIGN ALIGN EQ EQ F32 ? ? ? 8 7/8" - COORD W PIPE ENCLOSURE 2 2 OFFICE/RECEPT 117A OFFICE 117C D0sX D0sX WINDOW INFILL WINDOW INFILL D0sX ALIGN 7' - 0" CLEAR D0s D0s D0s D0sX 2 2 LEGEND EXISTING TO REMAIN NEW WALL EXISTING TO BE REMOVED REGION INDICATES AREA NOT IN SCOPE KEYNOTE LEGEND KEY PLAN GENERAL NOTES EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITION. PROVIDE CORNER OR WALL GUARDS PER FINISH PLANS. ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL EQUIPMENT AHEAD OF DEMOLITION WORK. PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE UNLESS APPROVED IN WRITING BY THE OWNER ON A CASE-BY-CASE BASIS. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING AND TRENCHING. PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS. WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL. STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:23:26 AM 15924.00 A-101A.2 ENLARGED DIMENSION FLOOR PLAN - AREA A 2017 07/11/17 PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 A B C D E NORTH 1/4" = 1'-0" A1 ENLARGED DIMENSION FLOOR PLAN AREA A F26 44" CLEAR MINIMUM. IF LESS THAN 44", GC TO MODIFY TO PROVIDE 44" CLEAR F32 MONITOR AND BRACKET; MATCH HEIGHT OF EXISTING LOCATION, OFCI. GC TO PROVIDE FRAMING WITHIN WALL. F51 CONFERENCE TABLE, OFCI. COORDINATE POWER AND AV CONNECTION WITH ELECTRICAL F101 PROVIDE THE FOLLOWING: 1. FILL WALL CAVITIES WITH ACOUSTIC SAFB SOUND BATTS. 2. SEAL ALL PENETRATIONS WITH ACOUSTIC RATED SEALANT AT ALL JOINTS AND DEVICES. 3. PROVIDE ACOUSTIC PUTTY BEHIND EACH WALL DEVICE BACK BOX. 4. WHERE NOT POSSIBLE FOR WALLS TO EXTEND TO DECK, PROVIDE 48" OF 6" THICK SAFB SOUND BATTS IN EACH DIRECTION HORIZONTALLY ABOVE THE CEILINGS. 5. WHERE NOT FULLY DUCTED, PROVIDE BOOT TYPE DUCTWORK CONFIGURATION AT RETURN DUCTS TO REDUCE THE PASSAGE OF SOUND. 6. AT DOORS WITHOUT PERIMETER GASKETS, PROVIDE PERIMETER GASKETING TO ALL NON-GASKETED DOORS. 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 ADDENDUM 1 05/23/17 1 ADDENDUM 3 06/27/17 2 08/28/17