HomeMy WebLinkAboutB17-0092_A-101A.2_1503950486.pdfOFFICE
106
OFFICE
114
OFFICE
119
OFFICE
122
CONFERENCE
ROOM
123
OFFICE
116A
OFFICE
121
OFFICE
117B
OFFICE
112
OFFICE
111
TLT
104
RECEPTION
102
BREAK
127
OFFICE
126
CORRIDOR
100B
HOT LAB
104B
NUCLEAR
MEDICINE
CAMERA
105A
CONTROL
104A
STORAGE
108
SPRINKLER ROOM
106A
CORRIDOR
118 ALIGN
ALIGN
CLEAR
4' - 9"
ALIGN
ALIGN
CLEAR
5' - 0" 9' - 10"
ALIGN
D0s
D0sX
D0b
D0b
D0s
D0s D0s
D0s
D0s D0s
D0s D0s
D0b
D0sXD0sX
D0f
D0s
D0s
D0bX
D0s
D0b
D0sX
D0s
D0b
STORAGE
127A 2' - 8"
D0s
D0s
D0b D0b
D0b
D0b
D0b
D0bD0b
?
ALIGN
INJECTION
104D
D0sX
1' - 9" 1' - 5" 4' - 10"
9"
1' - 4" 4' - 11"
D0sX
D0a
2' - 6"
OFFICE
128A
CORRIDOR
100
OFFICE
128B
STAFF RECESS
101
ALIGN
1' - 0"
D0f
ALIGN
D0f
ALIGN
D0sX
COPY
125
ALIGN
ALIGN
ALIG
ALIGN
ALIGN ALIGN
ALIG
ALIG
3"
2' - 8" 10' - 11"
2' - 4"
D0b
9' - 4"
EQ EQ
CL
1' - 7 1/8"
1' - 8 7/8"
3' - 10 1/4" 2' - 3 3/4"
30" CLEAR
6" 8' - 3 3/4"
D0s
D0s
ALIGN
ALIGN
ALIG
ALIGN
ALIGN
D0s
D0s D0s
F51
D0b
7' - 0" 8' - 4 7/8" 9' - 2 3/8"
3' - 5"
D0b EQ EQ
EQ EQ
F32
F32
ALIGN
ALIGN
ALIG
ALIGN
3' - 6" 3' - 2"
5' - 11"
(E) STORAGE
120Z
ALIGN
D0sX
ALIGN
6' - 6 3/4"
ALIGN
44" MIN. CLEAR
44" MIN. CLEAR
F26
F26
ALIGN
3' - 10"
CLOSET
100A
CLEAR
2' - 3 3/4"
OFFICE
128C
1
CLEAN STORAGE
130
STORAGE
131
ALIGN 5'-0" CLR MIN
5' - 5 1/4"
3' - 0"
1
1
PT TOILET
104C
ESR / SOILED
HOLD
104E
D0sX
F101
F101
F101 F101 F101
F101
D0sX
F101
D1b
D1b
J1b
J1b
1
7' - 6" CLEAR
7' - 6" CLEAR ALIGN
ALIGN
EQ EQ
F32
?
?
? 8 7/8" - COORD W PIPE
ENCLOSURE
2
2
OFFICE/RECEPT
117A
OFFICE
117C
D0sX D0sX
WINDOW
INFILL
WINDOW
INFILL
D0sX
ALIGN
7' - 0" CLEAR
D0s
D0s
D0s D0sX
2
2
LEGEND
EXISTING TO
REMAIN
NEW WALL
EXISTING TO BE
REMOVED
REGION INDICATES AREA
NOT IN SCOPE
KEYNOTE LEGEND
KEY PLAN
GENERAL NOTES
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR
CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL
SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P
COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE
SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND
OBTAINING AN APPROVED METHOD OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY
CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH
EXISTING CONDITION.
PROVIDE CORNER OR WALL GUARDS PER FINISH PLANS.
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL
EQUIPMENT AHEAD OF DEMOLITION WORK.
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE UNLESS
APPROVED IN WRITING BY THE OWNER ON A CASE-BY-CASE BASIS.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION
AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION,
INCLUDING BUT NOT LIMITED TO CORING AND TRENCHING.
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE
LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES
OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO
NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED
INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE
WALL.
STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
7/11/2017
10:23:26 AM
15924.00
A-101A.2
ENLARGED DIMENSION
FLOOR PLAN - AREA A
2017
07/11/17
PERMIT
RESUBMISSION
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
A
B
C
D
E
NORTH
1/4" = 1'-0"
A1
ENLARGED DIMENSION FLOOR PLAN AREA A
F26 44" CLEAR MINIMUM. IF LESS THAN 44", GC TO MODIFY TO
PROVIDE 44" CLEAR
F32 MONITOR AND BRACKET; MATCH HEIGHT OF EXISTING
LOCATION, OFCI. GC TO PROVIDE FRAMING WITHIN WALL.
F51 CONFERENCE TABLE, OFCI. COORDINATE POWER AND AV
CONNECTION WITH ELECTRICAL
F101 PROVIDE THE FOLLOWING: 1. FILL WALL CAVITIES WITH
ACOUSTIC SAFB SOUND BATTS. 2. SEAL ALL PENETRATIONS
WITH ACOUSTIC RATED SEALANT AT ALL JOINTS AND DEVICES.
3. PROVIDE ACOUSTIC PUTTY BEHIND EACH WALL DEVICE BACK
BOX. 4. WHERE NOT POSSIBLE FOR WALLS TO EXTEND TO DECK,
PROVIDE 48" OF 6" THICK SAFB SOUND BATTS IN EACH
DIRECTION HORIZONTALLY ABOVE THE CEILINGS. 5. WHERE NOT
FULLY DUCTED, PROVIDE BOOT TYPE DUCTWORK
CONFIGURATION AT RETURN DUCTS TO REDUCE THE PASSAGE
OF SOUND. 6. AT DOORS WITHOUT PERIMETER GASKETS,
PROVIDE PERIMETER GASKETING TO ALL NON-GASKETED
DOORS.
1
1
1
1
1
1
1 1
1
1
2
2
2
2
2
2
2
2
ADDENDUM 1 05/23/17 1
ADDENDUM 3 06/27/17 2
08/28/17