HomeMy WebLinkAboutB17-0092_A-101B.1_1498849020.pdfF.E.
(E)
CLEAN ROOM
120G
WORK AREA
120B
VEST
120A
5e86 6e86 7e86
Ke86
Je86
He86
BREAK
120H
5' - 5"
L0k L0k D0b
D0b
D0b
D0b
D0sX
D0b
D0b
D0sX
5' - 10"
J1b
J1b
J1b
4' - 9 3/4" 4' - 0 1/4"
HOLD
4' - 3 1/2"
D0f
D0f
D1sX
D0b
ALIGN
D0p
ALIGN
2' - 2"
D0b
D0b
ALIGN
ALIGN
5 3/8"
2' - 7"
D0b
ALIGN
D0b
D0f
D0sX
8' - 11"
HOLD
3' - 6"
2' - 2"
ALIGN
ALIGN
D0f
D0b
V.I.F.
3 EQ SPACES = 13' - 2 1/4"
ALIGN
5'-0" CLEAR
1' - 6"
L0k
PREP AREA
120D
CHEMO MIXING
ROOM
120E
ANTE ROOM
120F
PACKING AREA
120C
2' - 8"
1' - 6"
NON-STERILE
COMPOUDING
120I
D0b
LEGEND
EXISTING TO REMAIN
NEW WALL
EXISTING TO BE REMOVED
REGION INDICATES AREA
NOT IN SCOPE
KEYNOTE LEGEND
KEY PLAN
GENERAL NOTES
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR
CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM.
ALL SHUT DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON
WEEKENDS. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN
WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN
APPROVED METHOD OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL
CONDITION TO BE LIKE-NEW.
PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN
PATIENT AREAS
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH
OWNER
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND
PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT
NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF
VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT
SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO
THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL.
EXISTING FLOORING AND WALL FINISH TO BE REPLACED WHERE
FUNCTION OF SPACE IS CHANGING OR NEW FLOOR FINISH IS
SCHEDULED, TYP.
A-401B.1
D1
D2
C2
D3
A-401B.1
E4
E2
E3
A-401B.1
A2
A3
A-401B.1B3
A-200.1
A4
A-401B.1
A6
A1
A-401B.1
A5
B4
CLEAN ROOM
120G
WORK AREA
120B
F06
VEST
120A
120B 120G
120E
TYP
ALL
SIDES
F25
BREAK
120H
F30
F30
120A
120D
B2
REF
F25F25
B1
A-401B.1
E1
48 LF
42 LF
48 LF 42 LF 42 LF 42 LF 24 LF
A-401B.1D4
C3
C4
C1
F25
A-520B.1
A2
F42
W2
A-551.1
A6
A-551.1
A3
A-520B.1
A5
F25
ANTE ROOM
120F
PACKING AREA
120C
CHEMO MIXING
ROOM
120E
PREP AREA
120D
F14
A4
F22
F58
F63
F64
F34
F75
F54
W3
F79
F79
A-551.1
A1
F24
F42
F30
F22
NON-STERILE
COMPOUDING
120I
A-551.1
C1
F99
F99
F99
F99
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:35:25 PM
15924.00
A-101B.1
ENLARGED FLOOR PLAN -
AREA B
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
NORTH
F06 INFILL STOREFRONT SYSTEM TO MATCH EXISTING ADJACENT
SYSTEM IN DETAIL, COLOR, AND GENERAL AESTHETICS. GLASS
AND FILM TO MATCH ADJACENT SIMILAR CONDITIONS.
F14 CLEAN ROOM PASS-THROUGH CHAMBER; TERRA UNIVERSAL.COM
#2636-06D OR SIMILAR
F22 PROVIDE FILM ON BACK OF GLASS, TYPICAL THIS SECTION OF
GLASS ON THIS LEVEL
F24 UNDER CABINET LIGHTING, RE: ELECTRICAL
F25 REFINISH WALL, BOTH SIDES, TO LIKE-NEW FINISH; MATCH
ADJACENT CONDITIONS.
F30 EXISTING WALL TO REMAIN
F34 DASH LINE INDICATES CLEAN ROOM DEMARCATION LINE; SEE
FINISH PLANS FOR MORE INFORMATION.
F42 COUNTER MOUNTED MONITOR BRACKET. PROVIDE BLOCKING
AND FRAMING TO SUPPORT MONITOR INSTALLATION.
F54 FURNITURE/ EQUIPMENT BY OWNER
F58 RECESS POWER/DATA IN THIS LOCATION
F63 OF/ CI EQUIPMENT; FURNITURE BASE CASEWORK, FAX MACHINE,
AND UPPER CABINET WITH LOCK. GC TO PROVIDE BLOCKING AS
REQUIRED FOR THE UPPER CABINET
F64 INSTALLATION OF WALL TO BE UNDER PHARMACIST
SUPERVISION. GC TO COORDINATE INSTALLATION WITH OWNER
F75 EXISTING RELOCATED FILE CABINET, OF/ OI
F79 EXISTING RELOCATED CART, OF/ OI
F99 GROMMET IN COUNTERTOP; PROVIDE COUNT AS SHOWN - GC TO
COORDINATE FINAL LOCATION WITH OWNER
A
B
C
1/4" = 1'-0" A3
ENLARGED DIMENSION LEVEL 1 - AREA B
NORTH
1/4" = 1'-0"
C3
ENLARGED ANNOTATION LEVEL 1 - AREA B
06/30/17