HomeMy WebLinkAboutB17-0092_A-101B.1_1508947725.pdfF.E.
(E)
CLEAN ROOM
120G
WORK AREA
120B
VEST
120A
5e86 6e86 7e86
BREAK
120H
5' - 0" CLRL0kL0k D0b
D0b
D0b
D0b
D0sX
D0sX
5' - 10" 2' - 8"
J1b
J1b
J1b
4' - 8 7/8" 4' - 0 1/4"
HOLD
4' - 3 1/2"
D0f
D0f
D1sX
D0b
ALIGN
F0p
D0b
D0b
ALIGN
ALIGN2' - 7"D0b
D0b
D0f
D0sX
HOLD
3' - 3"ALIGNALIGND0f
D0b
ALIGN
L0k
PREP AREA
120D
CHEMO MIXING
ROOM
120E
ANTE ROOM
120F
PACKING AREA
120C
1' - 6"
NON-STERILE
COMPOUNDING
120I
D0b
8' - 6" 10' - 7" ALIGN
7' - 1"13' - 11 7/8"16' - 0 7/8"
2' - 2"
2' - 2"2' - 0" 3 1/2"2' - 2"4' - 6 1/4" 5' - 6"
5' - 0 1/8"
J0a
J0a 1' - 4 1/2"2' - 1"
LEGEND
EXISTING TO
REMAIN
NEW WALL
EXISTING TO BE
REMOVED
REGION INDICATES AREA
NOT IN SCOPE
KEYNOTE LEGEND
KEY PLAN
GENERAL NOTES
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR
CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL
SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P
COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE
SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND
OBTAINING AN APPROVED METHOD OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY
CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH
EXISTING CONDITION.
PROVIDE CORNER OR WALL GUARDS PER FINISH PLANS.
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL
EQUIPMENT AHEAD OF DEMOLITION WORK.
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE UNLESS
APPROVED IN WRITING BY THE OWNER ON A CASE-BY-CASE BASIS.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION
AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION,
INCLUDING BUT NOT LIMITED TO CORING AND TRENCHING.
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE
LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES
OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO
NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED
INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE
WALL.
STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER.A-401B.1
D1
D2C2
D3
A-401B.1
E4
E2
E3
A-401B.1
A2
A3
A-401B.1B3
A2
A-310.1
B3
A-300.1
A4
A-310.1
A-401B.1
A6 A1
A-401B.1
A5
B4
CLEAN ROOM
120G
WORK AREA
120B
VEST
120A
120B120G120ETYP
ALL
SIDES
F25
BREAK
120H
F30
F30
120A
120D
B2
F25F25
B1
A-401B.1
E5
E1
48 LF
42 LF48 LF42 LF 42 LF 42 LF 21 LFA-401B.1D4
C3
C4
C1
F25
A-520B.1
A2
F42
A-551.1
A6
A-551.1
A3
A-520B.1
A5
F25
ANTE ROOM
120F
PACKING AREA
120C
CHEMO MIXING
ROOM
120E
PREP AREA
120D
F14
A4
F22
F58
F64
A-551.1
A1
F42
F30
F22
NON-STERILE
COMPOUNDING
120I
A-551.1
C1
F99
F99
F99
3' - 0"4' - 8"
W2
3
F99F99
F99
TYP
F75
F99
TYP
F99
3
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL WING RENOVATION
8/11/2017 4:36:05 PM15924.00
A-101B.1
ENLARGED FLOOR PLAN -
AREA B
2017
07/11/17PERMIT
RESUBMISSION
VAIL VALLEY
MEDICAL
CENTER
180 S. Frontage
Road West, Vail, CO 81657NORTH
F14 CLEAN ROOM PASS-THROUGH CHAMBER; TERRA
UNIVERSAL.COM #2636-06D OR SIMILAR
F22 PROVIDE FILM ON BACK OF GLASS, TYPICAL THIS SECTION
OF GLASS ON THIS LEVEL
F25 REFINISH WALL, BOTH SIDES, TO LIKE-NEW FINISH; MATCH
ADJACENT CONDITIONS.
F30 EXISTING WALL TO REMAIN
F42 COUNTER MOUNTED MONITOR BRACKET. PROVIDE
BLOCKING AND FRAMING TO SUPPORT MONITOR
INSTALLATION.
F58 RECESS POWER/DATA IN THIS LOCATION
F64 INSTALLATION OF WALL TO BE UNDER PHARMACIST
SUPERVISION. GC TO COORDINATE INSTALLATION WITH
OWNER
F75 EXISTING RELOCATED FILE CABINET, OF/ OI
F99 GROMMET IN COUNTERTOP; PROVIDE COUNT AS SHOWN -
GC TO COORDINATE FINAL LOCATION WITH OWNER
A
B
C
D
E
1/4" = 1'-0"A3 ENLARGED DIMENSION LEVEL 1 - AREA B
NORTH
1/4" = 1'-0"C3 ENLARGED ANNOTATION LEVEL
1 - AREA B
3
ADDENDUM 1 05/23/17 1
RFC0021 07/21/17 2
ASI 02 08/11/17 3
10/25/17