Loading...
HomeMy WebLinkAboutB17-0092_A-102C.1_1503950442.pdfT A-401C.1A4 A3 STORAGE 120Y OFFICE 120YY OFFICE 120J OFFICE 120K EXAM 120L EXAM 120M EXAM 120N EXAM 120P BREAK 120O OFFICE 120U RECEPTION 120R PT TLT 120V LARGE EXAM ROOM 120W WAIT 120Q A-401C.1 B5 B3 B4 120Y A6 A5 X120K A-401C.1 C6 120V A-401C.1 C4 C5 COPIER OFCI CORRIDOR 120T F32 B6 F86 F85F85 F87 F88 121Y MEETING/WORK 121Y F100 F99 F99 F99 F99 F99 F99 1 LEGEND EXISTING TO REMAIN NEW WALL EXISTING TO BE REMOVED REGION INDICATES AREA NOT IN SCOPE KEYNOTE LEGEND KEY PLAN GENERAL NOTES EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITION. PROVIDE CORNER OR WALL GUARDS PER FINISH PLANS. ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL EQUIPMENT AHEAD OF DEMOLITION WORK. PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE UNLESS APPROVED IN WRITING BY THE OWNER ON A CASE-BY-CASE BASIS. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING AND TRENCHING. PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS. WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL. STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:23:47 AM 15924.00 A-102C.1 ENLARGED ANNOTATION FLOOR PLAN - AREA C 2017 07/11/17 PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/4" = 1'-0" A1 ENLARGED ANNOTATION LEVEL 2 - AREA C F32 MONITOR AND BRACKET; MATCH HEIGHT OF EXISTING LOCATION, OFCI. GC TO PROVIDE FRAMING WITHIN WALL. F85 EXISTING EQUIPMENT TO BE RELOCATED. F86 DASH LINE INDICATES CLEARANCE FROM EXAM CHAIR. F87 EXISTING WALL TO REMAIN; ADD 48" ACOUSTIC BATT INSULATION EXTENDING BOTH SIDES OF EXISTING PARTITION. F88 OFCI EXAM CHAIR F99 GROMMET IN COUNTERTOP; PROVIDE COUNT AS SHOWN - GC TO COORDINATE FINAL LOCATION WITH OWNER F100 PROVIDE TRIM AT EDGE OF COUNTER AT AREA IMPACTED BY DEMOLITION. A B C D E NORTH 1 1 1 ADDENDUM 1 05/23/17 1 08/28/17