HomeMy WebLinkAboutB17-0092_A-102C.2_1498849020.pdfCe78
Be78
Ke86
Je86
He86
3e78 4e78 5e78 6e78 7e78 9e78 12e78 13e78 18e78 21e78
De78
De79
EXAM
120L
EXAM
120M
EXAM
120N
D1s
D1sD1s D1s
J1bJ1b
LARGE EXAM
ROOM
120W
STORAGE
120Y
BREAK
120O
EXAM
120P
RECEPTION
120R
WAIT
120Q
CORRIDOR
120T
TLT
120V
OFFICE
120K
OFFICE
120J
OFFICE
120YY
OFFICE
120U
ALIGN
ALIGN
3' - 5" 3' - 0" 4' - 2"
GC TO VIF
5' - 1"
J1b
J1bJ1b
D0s
D0s
D0bD0b D0a
D0b
D0s
7' - 2"
D1s
ALIGN
6"
2' - 8 7/8" CLR.
3' - 8"
5' - 4 7/8"
ALIGN
CLEAR 5' - 1"
D0b
ALIGN
D0sX
1' - 6"
J0bX
LEGEND
EXISTING TO REMAIN
NEW WALL
EXISTING TO BE REMOVED
REGION INDICATES AREA
NOT IN SCOPE
KEYNOTE LEGEND
KEY PLAN
GENERAL NOTES
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR
CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM.
ALL SHUT DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON
WEEKENDS. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN
WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN
APPROVED METHOD OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL
CONDITION TO BE LIKE-NEW.
PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN
PATIENT AREAS
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH
OWNER
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND
PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT
NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF
VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT
SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO
THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL.
EXISTING FLOORING AND WALL FINISH TO BE REPLACED WHERE
FUNCTION OF SPACE IS CHANGING OR NEW FLOOR FINISH IS
SCHEDULED, TYP.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:35:47 PM
15924.00
A-102C.2
ENLARGED DIMENSION
FLOOR PLAN - AREA C
2017
03/10/17
PERMIT
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1/4" = 1'-0"
A1
ENLARGED DIMENSION FLOOR PLAN - AREA C
NORTH A
B
C
ADDENDUM #1 03/10/17 1
clarify this use.
06/30/17