HomeMy WebLinkAboutB17-0092_A-151A.1_1498849020.pdfH
OFFICE
106
OFFICE
114
OFFICE
117
OFFICE
119
OFFICE
122
CONFERENCE
ROOM
123
OFFICE
116A OFFICE
116B
OFFICE
121
OFFICE
120
OFFICE
112
OFFICE
111
TLT
104
RECEPTION
102
BREAK
127
OFFICE
126
ULTRASOUND
113
CORRIDOR
100B
HOT LAB
104B
NUCLEAR
MEDICINE
CAMERA
105A
CONTROL
104A
STORAGE
108
CORRIDOR
109
SPRINKLER ROOM
106A
De01 Ce01 Be01 Ee01 Fe01 Ge01 He01 Je01
2e01
3e01
4e01
5e01
6e01
8' - 0"
8' - 0"
8' - 0"
8' - 0" 8' - 0"
8' - 0"
8' - 0"
8' - 0"
C03
C03
C03
C03
C03
8' - 0"
8' - 0"
OFFICE
128A
COPY
125
PT TOILET
104C
SOILED HOLD
105B
ESR
105C
INJECTION
104D
8' - 0"
8' - 0"
8' - 0"
8' - 0"
STORAGE
118A
2' - 0"
E1
A-550.1
SIM
8' - 0"
2' - 0"
2' - 0" 1' - 0"
8' - 0"
2' - 0" 8"
C03
2' - 0"
2' - 0" 2' - 0"
8' - 0"
2' - 0"
2' - 0"
C03
8' - 0"
7' - 10"
8' - 0"
8' - 0"
8' - 0"
8' - 0" 2' - 0"
2' - 0"
C07
C03
C03
2' - 0"
2' - 0"
C03
ALIGN ALIGN
OFFICE
128B
OFFICE
128C
C03
C03
C03
C10
E1
A-550.1
SIM
C10
7' - 0"
1' - 3"
8' - 0"
C11C11
8' - 0"
CORRIDOR
100
STAFF RECESS
101
4"
2' - 7"
EQ EQ
3' - 3"
6 1/2"
11"
C03
ALIGN
1' - 10"
6" 1' - 10"
1' - 0"
1' - 10"
1' - 2 1/2" 1' - 8" C03
ALIGN
7"
2' - 0"
1' - 3 1/2"
2' - 0"
8' - 0"
2' - 0"
C07
4' - 5"
4' - 11"
EQ. EQ.
EQ. EQ.
(E) STORAGE
120Z
CLOSET
100A
3' - 10 1/2"
EQ EQ
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING THE HOURS OF XX AND XX AND ALL SHUT
DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON WEEKENDS.
ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST
COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD
OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL
CONDITION TO BE LIKE-NEW.
PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN
PATIENT AREAS
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH
OWNER
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND
PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT
NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF
VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT
SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO
THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL.
EXISTING FLOORING AND WALL FINISH TO BE REPLACED WHERE
FUNCTION OF SPACE IS CHANGING OR NEW FLOOR FINISH IS
SCHEDULED, TYP.
GENERAL NOTES
GENERAL NOTES
AREA NOT IN SCOPE
GYP. BOARD CEILING
2' x 2' ACT CEILING
EPOXY FINISH ON GYP.
BOARD CEILING
EXISTING 2' x 2' ACT
CEILING
KEY PLAN
KEYNOTE LEGEND
MECHANICAL DIFFUSER
(SUPPLY AIR)
MECHANICAL DIFFUSER
(RETURN AIR)
2' x 4' LIGHT
2' x 2' LIGHT
RECESSED CAN
LIGHT FIXTURE
8' x 0" CEILING HEIGHT
ABOVE FINISH FLOOR
4' - 0" PENDANT LIGHT
18" x 18" ACCESS PANEL
2' - 0" WALL
DECORATIVE
LINEAR LIGHT
4' - 0" STRIP LIGHT
CUBICLE CURTAIN
TRACK
NOTE: NOT ALL SYMBOLS SHOWN ON THE DRAWINGS ARE INDICATED
BELOW. SEE MECHANICAL, ELECTRICAL FIRE ALARM, AND TECHNOLOGY
DRAWINGS FOR ADDITIONAL SYMBOLS AND SYSTEMS INFORMATION
SECURITY CAMERA
EXISTING GYP.
BOARD CEILING
EXIT LIGHTING
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:36:16 PM
15924.00
A-151A.1
ENLARGED REFLECTED
CEILING PLAN AREA A
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1/4" = 1'-0"
A1
ENLARGED REFLECTED CEILING PLAN AREA A
C03 ACOUSTIC CEILING GRID START POINT.
C07 INTEGRATE NEW CEILING INTO EXISTING CEILING SYSTEM.
C10 CUBICLE CURTAIN WITH TRACK. CURTAIN PROVIDED BY OWNER.
C11 NEW PARTITION TO TERMINATE AT EXISTING SOFFIT IN THIS
LOCATION; APPLY SEALANT ALONG PERIMETER.
A
B
C
NORTH
06/30/17