Loading...
HomeMy WebLinkAboutB17-0092_A-151A.1_1503950444.pdfH OFFICE 106 OFFICE 114 OFFICE 119 OFFICE 122 CONFERENCE ROOM 123 OFFICE 116A OFFICE 121 OFFICE 117B OFFICE 112 OFFICE 111 TLT 104 RECEPTION 102 BREAK 127 OFFICE 126 CORRIDOR 100B HOT LAB 104B NUCLEAR MEDICINE CAMERA 105A CONTROL 104A STORAGE 108 SPRINKLER ROOM 106A 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" C03 C03 C03 C03 C03 8' - 0" 8' - 0" OFFICE 128A COPY 125 INJECTION 104D 8' - 0" 8' - 0" STORAGE 118A 2' - 0" 8' - 0" 2' - 0" 2' - 0" 8' - 0" 2' - 0" 8" C03 2' - 0" 2' - 0" 2' - 0" 8' - 0" 2' - 0" 2' - 0" C03 7' - 10" 8' - 0" 8' - 0" 8' - 0" 2' - 0" 2' - 0" C07 C03 C03 ALIGN ALIGN OFFICE 128B OFFICE 128C C03 E1 A-550.1 SIM C10 7' - 0" 1' - 3" C11C11 8' - 0" CORRIDOR 100 STAFF RECESS 101 1' - 10" 6 1/2" 11" C03 ALIGN 2' - 0" 6" 2' - 0" 1' - 2 1/2" 1' - 8" C03 ALIGN 7" 1' - 3 1/2" 2' - 0" 8' - 0" 2' - 0" C07 EQ. EQ. EQ. EQ. (E) STORAGE 120Z CLOSET 100A 2' - 0" 2' - 0" C03 C03 1 PT TOILET 104C ESR / SOILED HOLD 104E 1 2' - 0" CLEAN STORAGE 130 STORAGE 131 1 C03 C03 1' - 8" 2' - 0" 8' - 0" C14 1 1 C07 8' - 0" 8' - 0" 8' - 0" 10' - 4" C1 A-550.1 2' - 0" 2' - 0" 3' - 10" 6' - 0" C15 C07 STORAGE 127A CORRIDOR 03 C3 A-550.1 4' - 6" 4' - 9" 7' - 0" 7' - 0" ALIGN C4 A-550.1 OFFICE 117C OFFICE/RECEPT 117A EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN PATIENT AREAS ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS. WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL. GENERAL NOTES GENERAL NOTES AREA NOT IN SCOPE GYP. BOARD CEILING 2' x 2' ACT CEILING EPOXY FINISH ON GYP. BOARD CEILING EXISTING 2' x 2' ACT CEILING KEY PLAN KEYNOTE LEGEND MECHANICAL DIFFUSER (SUPPLY AIR) MECHANICAL DIFFUSER (RETURN AIR) 2' x 4' LIGHT 2' x 2' LIGHT RECESSED CAN LIGHT FIXTURE 8' x 0" CEILING HEIGHT ABOVE FINISH FLOOR 4' - 0" PENDANT LIGHT 18" x 18" ACCESS PANEL 2' - 0" WALL DECORATIVE LINEAR LIGHT 4' - 0" STRIP LIGHT CUBICLE CURTAIN TRACK NOTE: NOT ALL SYMBOLS SHOWN ON THE DRAWINGS ARE INDICATED BELOW. SEE MECHANICAL, ELECTRICAL FIRE ALARM, AND TECHNOLOGY DRAWINGS FOR ADDITIONAL SYMBOLS AND SYSTEMS INFORMATION SECURITY CAMERA EXISTING GYP. BOARD CEILING EXIT LIGHTING 2' x 2' ACT CEILING SCRUBBABLE GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITION. GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL EQUIPMENT AHEAD OF DEMOLITION WORK. STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER. REMOVE AND REPLACE (E) CEILING RE: INTERIM LIFE SAFETY PLANS FOR MORE INFO. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:24:18 AM 15924.00 A-151A.1 ENLARGED REFLECTED CEILING PLAN AREA A 2017 07/11/17 PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/4" = 1'-0" A1 ENLARGED REFLECTED CEILING PLAN AREA A C03 ACOUSTIC CEILING GRID START POINT. C07 INTEGRATE NEW CEILING INTO EXISTING CEILING SYSTEM. C10 CUBICLE CURTAIN WITH TRACK. CURTAIN PROVIDED BY OWNER. C11 NEW PARTITION TO TERMINATE AT EXISTING SOFFIT IN THIS LOCATION; APPLY SEALANT ALONG PERIMETER. C14 PROVIDE CONVEX MIRROR IN THE CEILING GRID. C15 REFINISH REPLACED CEILING IN THIS AREA TO MATCH EXISTING FOR SEAMLESS APPEARANCE. A B C D E NORTH 1 1 1 1 1 1 1 3 3 ADDENDUM 1 05/23/17 1 RFC0007 06/13/17 2 ADDENDUM 3 06/27/17 3 08/28/17