HomeMy WebLinkAboutB17-0092_A-151A.1_1508947729.pdfOFFICE
106
OFFICE
114
OFFICE
119
OFFICE
122
CONFERENCE
ROOM
123
OFFICE
116A
OFFICE
121
OFFICE
117B
OFFICE
112
OFFICE
111
TLT
104
RECEPTION
102
BREAK
127
OFFICE
126
CORRIDOR
100B
HOT LAB
104B
NUCLEAR
MEDICINE
CAMERA
105A
CONTROL
104A
STORAGE
108
SPRINKLER ROOM
106A
8' - 0"
8' - 0"
7' - 6"
8' - 0" 8' - 0"
8' - 0"
8' - 0"
8' - 0"
C03
C03
C03
C03
C03
8' - 0"
8' - 0"
OFFICE
128A
COPY
125
INJECTION
104D
7' - 6"
7' - 6"
STORAGE
118A2' - 0"7' - 6"
2' - 0"
8' - 0"
2' - 0" 8"C03
2' - 0" 2' - 0"2' - 0"8' - 0"2' - 0"2' - 0"
C03
7' - 10"
8' - 0"
8' - 0"
8' - 0" 2' - 0"2' - 0"
C07
C03
C03
ALIGN ALIGN
OFFICE
128B
OFFICE
128C
C03
E1
A-550.1
SIM
C10
D5
A-320.1
7' - 0"
1' - 3"
C11C11
8' - 0"
CORRIDOR
100
OFFICE
101
1' - 10"
6 1/2"11"C03 2' - 0"6"2' - 0"1' - 2 1/2"1' - 8"C03
ALIGN
7"
1' - 3 1/2"2' - 0"8' - 0"
C07
EQ. EQ.EQ. EQ.
CLOSET
100A
C03 C03
PT TOILET
104C
ESR / SOILED
HOLD
104E 2' - 0"CLEAN STORAGE
130
STORAGE
131
C03 C03
1' - 8"2' - 0"8' - 0"
C14
C07
8' - 0"
8' - 0"
8' - 0"
10' - 4"
C1
A-550.1 2' - 0"2' - 0"3' - 10" 6' - 0"C15
C07
STORAGE
127A
CORRIDOR
03
C3
A-550.1 4' - 6"4' - 9"
7' - 0"7' - 0"
ALIGN
C4
A-550.1
OFFICE
117C
OFFICE/RECEPT
117A
C16
C16
2' - 0"2' - 0"C03
1' - 0" 1' - 0"
7' - 6"
7' - 2"
7' - 6" 1' - 0"C3
A-550.1
SIM
A1
A-550.1
2' - 6 1/2"
1' - 0"
6' - 4"
C2
A-551.1 2' - 0"2' - 0"
4' - 0"
HATCH INDICATES EXTENT OF EXISTING 1967
CONCRETE STRUCTURE ABOVE THE CEILING.
GC TO PROVIDE NEW STEEL FRAMING AND SUPPORTS
PER STRUCTURAL DRAWINGS, AND PROVIDE 2 HOUR FIRE
RESISITIVE CONSTRUCTION ALONG THE ENTIRE LENGTH OF
THE JOINT AND OVER ANY EXPOSED NEW STRUCTURAL STEEL
E2
A-551.1
B1
A-551.1
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING ALL HOURS OF THE DAY. REGULAR
CONSTRUCTION WORK HOURS ARE FROM 7:00 AM AND 5:30 PM. ALL
SHUT DOWNS OR MODIFICATIONS SHALL BE COMPLETED PER M.O.P
COORDINATION PROCESSES. ADDITIONALLY, NO SYSTEM IS TO BE
SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND
OBTAINING AN APPROVED METHOD OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN
PATIENT AREAS
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION
AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION,
INCLUDING BUT NOT LIMITED TO CORING, TRENCHING, AND FINISH
MODIFICATIONS
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE
LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES
OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO
NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED
INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE
WALL.
GENERAL NOTES
GENERAL NOTES
AREA NOT IN SCOPE
GYP. BOARD CEILING
2' x 2' ACT CEILING
EPOXY FINISH ON
GYP. BOARD CEILING
EXISTING 2' x 2' ACT
CEILING
KEY PLAN
KEYNOTE LEGEND
MECHANICAL DIFFUSER
(SUPPLY AIR)
MECHANICAL DIFFUSER
(RETURN AIR)
2' x 4' LIGHT 2' x 2' LIGHT
RECESSED CAN
LIGHT FIXTURE
8' x 0" CEILING HEIGHT
ABOVE FINISH FLOOR
4' - 0" PENDANT LIGHT
18" x 18" ACCESS
PANEL
2' - 0" WALL
DECORATIVE
LINEAR LIGHT
4' - 0" STRIP LIGHT
CUBICLE CURTAIN
TRACK
NOTE: NOT ALL SYMBOLS SHOWN ON THE DRAWINGS ARE INDICATED
BELOW. SEE MECHANICAL, ELECTRICAL FIRE ALARM, AND TECHNOLOGY
DRAWINGS FOR ADDITIONAL SYMBOLS AND SYSTEMS INFORMATION
SECURITY CAMERA
EXISTING GYP.
BOARD CEILING
EXIT LIGHTING
2' x 2' ACT CEILING
SCRUBBABLE
GC TO PROTECT EXISTING FINISHES. FINISHES IMPACTED BY
CONSTRUCTION TO BE REPAIRED OR REPLACED TO MATCH
EXISTING CONDITION.
GC TO PROVIDE OWNER WITH OPPORTUNITY TO REMOVE MEDICAL
EQUIPMENT AHEAD OF DEMOLITION WORK.
STORE RECYCLABLES SUCH AS COPPER FOR SALVAGE BY OWNER.
REMOVE AND
REPLACE (E) CEILING
RE: INTERIM LIFE
SAFETY PLANS FOR
MORE INFO.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
9/1/2017 3:29:45 PM15924.00
A-151A.1
ENLARGED REFLECTED
CEILING PLAN AREA A
2017
07/11/17PERMIT
RESUBMISSION
1/4" = 1'-0"A1 ENLARGED REFLECTED CEILING PLAN AREA A
C03 ACOUSTIC CEILING GRID START POINT.
C07 INTEGRATE NEW CEILING INTO EXISTING CEILING SYSTEM.
C10 CUBICLE CURTAIN WITH TRACK. CURTAIN PROVIDED BY OWNER.
C11 NEW PARTITION TO TERMINATE AT EXISTING SOFFIT IN THIS
LOCATION; APPLY SEALANT ALONG PERIMETER.
C14 PROVIDE CONVEX MIRROR IN THE CEILING GRID.
C15 REFINISH REPLACED CEILING IN THIS AREA TO MATCH EXISTING
FOR SEAMLESS APPEARANCE.
C16 IF WALL ASSEMBLY MODIFICATION AT PERIMETER OF ROOM
IMPACTS CEILING SYSTEM, REBUILD CEILING TO MATCH
EXISTING CONDITION.
A
B
C
D
E
NORTH
ADDENDUM 1 05/23/17 1
RFC0007 06/13/17 2
ADDENDUM 3 06/27/17 3
ASI 02 08/11/17 4
RFC0047 08/14/17 5
RFC0048 08/24/17 6
ASI 04 08/31/17 7
7
CENTRAL
WING RENOVATION
VAIL VALLEY
MEDICAL
CENTER
180 S. Frontage
Road West,
Vail, CO 8165710/25/17