HomeMy WebLinkAboutB17-0092_A-151B.1_1498849020.pdfCLEAN ROOM 120G WORK AREA 120B 5e86 6e86 7e86 8e86 Ke86 Je86 He86 9' - 0" 8' - 0" 8' - 0" 8' - 0" C03 BREAK 120H VEST 120A 8' - 0" 2' - 0" 1' - 0" 1' - 3" C03 2' - 0" 2' - 7"PACKING AREA 120C PREP AREA 120D CHEMO MIXING ROOM 120E ANTE ROOM 120F 4' - 11" 1' - 3" 1' - 4" 3' - 7" 2' - 1" 1' - 8" 2' - 1" 2' - 1" 2' - 3" 1' - 1 1/2"C12 EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING THE HOURS OF XX AND XX AND ALL SHUT DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON WEEKENDS. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL CONDITION TO BE LIKE-NEW. PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN PATIENT AREAS ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH OWNER PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS. WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL. EXISTING FLOORING AND WALL FINISH TO BE REPLACED WHERE FUNCTION OF SPACE IS CHANGING OR NEW FLOOR FINISH IS SCHEDULED, TYP. GENERAL NOTES GENERAL NOTES AREA NOT IN SCOPE GYP. BOARD CEILING 2' x 2' ACT CEILING EPOXY FINISH ON GYP. BOARD CEILING EXISTING 2' x 2' ACT CEILING KEY PLAN KEYNOTE LEGEND MECHANICAL DIFFUSER (SUPPLY AIR) MECHANICAL DIFFUSER (RETURN AIR) 2' x 4' LIGHT 2' x 2' LIGHT RECESSED CAN LIGHT FIXTURE 8' x 0" CEILING HEIGHT ABOVE FINISH FLOOR 4' - 0" PENDANT LIGHT 18" x 18" ACCESS PANEL 2' - 0" WALL DECORATIVE LINEAR LIGHT 4' - 0" STRIP LIGHT CUBICLE CURTAIN TRACK NOTE: NOT ALL SYMBOLS SHOWN ON THE DRAWINGS ARE INDICATED BELOW. SEE MECHANICAL, ELECTRICAL FIRE ALARM, AND TECHNOLOGY DRAWINGS FOR ADDITIONAL SYMBOLS AND SYSTEMS INFORMATION SECURITY CAMERA EXISTING GYP. BOARD CEILING EXIT LIGHTING 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 3:36:20 PM 15924.00 A-151B.1 ENLARGED REFLECTED CEILING PLAN AREA B 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/4" = 1'-0" A3 ENLARGED REFLECTED CEILING PLAN AREA B C03 ACOUSTIC CEILING GRID START POINT. C12 COORDINATE LIGHTING LOCATION WITH MILLWORK TO ENSURE MAINTENANCE OF THE LIGHT FIXTURE A B C NORTH 06/30/17