HomeMy WebLinkAboutB17-0092_A-152C.1_1498849020.pdfH
Be78
3e78 4e78 5e78 6e78 7e78 9e78 12e78 13e78 18e78 21e78
De79
(E) LAB
(E) LAB
(E) PHYSICIAN'S
OFFICE
(E) SLEEP
(E) SLEEP
C10
LARGE EXAM
ROOM
120W
OFFICE
120YY
OFFICE
120J
OFFICE
120K
EXAM
120L
EXAM
120M
EXAM
120N
EXAM
120P
BREAK
120O
OFFICE
120U
WAIT
120Q
RECEPTION
120R
CORRIDOR
120T
TLT
120V
STORAGE
120Y
7' - 9"
8' - 7"
C05
1' - 6"
C03
1' - 9" 2' - 0"
C03
1' - 5"
C03
EQ
7' - 10"
3' - 0" 4' - 9 1/2"
2' - 0"
C05
C13
C05
8' - 0"
EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN
OPERATIONAL DURING THE HOURS OF XX AND XX AND ALL SHUT
DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON WEEKENDS.
ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST
COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD
OF PROCEDURE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL
CONDITION TO BE LIKE-NEW.
PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN
PATIENT AREAS
ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE
MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES.
SEE LS SERIES FOR MORE INFORMATION.
DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE
UNLESS NOTED OTHERWISE
SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH
OWNER
PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO
CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE
DRYWALL INSTALLATION.
WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE
DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE.
CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND
PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT
NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS
PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS.
WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF
VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT
SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO
THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL.
EXISTING FLOORING AND WALL FINISH TO BE REPLACED WHERE
FUNCTION OF SPACE IS CHANGING OR NEW FLOOR FINISH IS
SCHEDULED, TYP.
GENERAL NOTES
GENERAL NOTES
AREA NOT IN SCOPE
GYP. BOARD CEILING
2' x 2' ACT CEILING
EPOXY FINISH ON GYP.
BOARD CEILING
EXISTING 2' x 2' ACT
CEILING
KEY PLAN
KEYNOTE LEGEND
MECHANICAL DIFFUSER
(SUPPLY AIR)
MECHANICAL DIFFUSER
(RETURN AIR)
2' x 4' LIGHT
2' x 2' LIGHT
RECESSED CAN
LIGHT FIXTURE
8' x 0" CEILING HEIGHT
ABOVE FINISH FLOOR
4' - 0" PENDANT LIGHT
18" x 18" ACCESS PANEL
2' - 0" WALL
DECORATIVE
LINEAR LIGHT
4' - 0" STRIP LIGHT
CUBICLE CURTAIN
TRACK
NOTE: NOT ALL SYMBOLS SHOWN ON THE DRAWINGS ARE INDICATED
BELOW. SEE MECHANICAL, ELECTRICAL FIRE ALARM, AND TECHNOLOGY
DRAWINGS FOR ADDITIONAL SYMBOLS AND SYSTEMS INFORMATION
SECURITY CAMERA
EXISTING GYP.
BOARD CEILING
EXIT LIGHTING
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:36:37 PM
15924.00
A-152C.1
ENLARGED REFLECTED
CEILING PLAN - LEVEL 2 -
AREA C
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1/4" = 1'-0"
A1
RCP - LEVEL 2 - AREA C - PHASE 1.5
A
B
C
NORTH
C03 ACOUSTIC CEILING GRID START POINT.
C05 ALIGN NEW CEILING GRID TO EXISTING CEILING GRID
C10 CUBICLE CURTAIN WITH TRACK. CURTAIN PROVIDED BY OWNER.
C13 EXTEND BULKHEAD CEILING
ADDENDUM #1 03/10/17 1
06/30/17