HomeMy WebLinkAboutB17-0092_A-401C.1_1503950455.pdfBD1536
BD1536 B3636
B3636
NOTE: ALL MILLWORK THIS ELEVATION TO BE LOCKABLE
W3030 W3630 W3030 W3630 W3030
BS3034
BS3034
F43
F53
F53 F53
F53
F52
F52
F74
TA6
TA5 TA6
TA5
TA1
TA2
TA3
TA1
TA7
TA6
F15
TA5 RE: D5/ A-320.1
FOR
DETAIL
4' - 11 1/2" WALL
TILE
F60
F61F61
F47
TA1TA1
TA2
TA4
RE: D5/ A-320.1
FOR
DETAIL
4' - 11 1/2" WALL
TILE
F60
F61F61
COUNTER TOP DEPTH TO BE 25" FOR BASE CABINETS AND
31" FOR ALL 30" HT WORK-SURFACES U.N.O.
STYLE
WIDTH OF
B1836
HEIGHT OF
BASE
WALL CABINET DEPTH TO BE 15"
U.N.O.
STYLE
WIDTH OF
W1836
HEIGHT OF
WALL AND TALL
STYLE
B BASE CABINET WITH DOOR & DRAWERS
BD BASE CABINET WITH DRAWERS
BF BASE FILE CABINET
BN BASE CABINET WITHOUT DOOR & DRAWER
BS ADA SINK BASE CABINET
K KNEE OPENING
KT KNEE OPENING WITH KEYBOARD TRAY
KD KNEE OPENING WITH PENCIL DRAWER
T TALL CABINET WITH DOORS
TG TALL CABINET WITH SLIDING GLASS DOORS
W WALL CABINET WITH DOORS
WG WALL CABINET WITH SLIDING GLASS DOORS
WN WALL CABINET WITH NO DRAWERS
AS ADJUSTABLE SHELVES
CASEWORK NOTE:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
REFER TO ELEVATIONS FOR DOOR, DRAWER, AND SHELF CONFIGURATIONS.
ALL SOLID SURFACE COUNTERTOPS TO BE SS1, U.N.O.
ALL PLAM COUNTERTOPS TO BE PL3, U.N.O.
ALL PLAM CABINETS TO BE PL1, U.N.O.
REFER TO INTERIOR FINISH DRAWINGS FOR FINISH INFORMATION.
PROVIDE 4" RUBBER COVE BASE AT ALL CASEWORK KICKSPACES, U.N.O.
COORDINATE ALL EQUIPMENT PLANS AND ELECTRICAL DOCUMENTS FOR
LOCATION OF ALL REQUIRED GROMMETS.
PROVIDE 4" HEIGHT INTEGRAL COVE BACK SPLASH WHERE BACKSPLASH IS
INDICATED ON INTERIOR ELEVATIONS IN NON-HEALTHCARE HANDWASHING
SINK AREAS. AT HEALTHCARE SINK AREAS, SIDE SPLASH, BACK SPLASH, AND
FREE-STANDING SPLASH PANEL TO FLANK ALL SIDES OF HANDWASHING
SINK. HEIGHT OF HEALTHCARE SINK TO BE ABOVE THE TOP OF THE FAUCET
WATER SUPPLY LOCATION AT A MINIMUM. AT HEALTHCARE SINK LOCATIONS,
SIDE, BACK, AND FREE-STANDING SPLASH PANEL TO BE OF THE SAME
MATERIAL AS THE COUNTERTOP U.N.O.
FIELD VERIFY DIMENSIONS OF WALL LAYOUTS BEFORE FABRICATION OF
CASEWORK.
PROVIDE FINISHED END PANELS AT ALL EXPOSED SIDES OF CASEWORK.
ALL SOLID SURFACE OR ENGINEERED STONE COUNTERTOPS TO HAVE
EASED EDGE AND BE FINISHED ON ALL EXPOSED SIDES AND BOTTOM.
PROVIDE FRAMING SUPPORT FOR UNSUPPORTED OR FREE-STANDING
COUNTERTOPS. SEE A4/A592.1 FOR MORE INFORMATION.
PROVIDE RADIUS ON COUNTER TOP CORNERS. SEE DETAIL A6/A-592.1 FOR
MORE INFORMATION.
CASE WORK LEGEND
INTERIOR ELEVATIONS GENERAL NOTES & LEGEND
A.
B.
C.
EQUIPMENT TAG. SEE Q SERIES FOR MEDICAL EQUIPMENT INFORMATION.
TOILET ACCESSORIES TAG. SEE A-760.2 FOR TOILET ACCESSORIES
INFORMATION.
FINISH TAG. SEE A-600 SERIES FOR FINISH INFORMATION.
E #
XX#
TA
F57
F29
F57
F29
F57
F29
W3230 W2330
E2
A-591.1
SIM
F89
F53
F53
F90
1' - 8"
2' - 10" A3
A-591.1
SIM
W3830 W3830 W3830 W3830
F74
F53
F43
F53
F43
F55
F29 F95
2' - 10" 1' - 8"
W3430 W3430
W3430
A3
A-591.1
SIM
F74
F53 F53
F43
F29
3' - 10"
TA8
RE: D5/ A-320.1
FOR
DETAIL
4' - 11 1/2" WALL
TILE
F60
F61 F61
F60
F61F61
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
7/11/2017
10:25:31 AM
15924.00
A-401C.1
AREA C ENLARGED PLANS
AND INTERIOR
ELEVATIONS
2017
07/11/17
PERMIT
RESUBMISSION
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1/4" = 1'-0"
A4
LARGE EXAM - EAST
1/4" = 1'-0"
B3
TLT - NORTH
1/4" = 1'-0"
B4
TLT - EAST
F15 SINK WITH PIPE PROTECTION, RE: PLUMBING
F29 WALL BASE, RE: FINISH SCHEDULE
F43 P.LAM CABINETRY FUR-DOWN WITH END PANEL ON BOTH SIDES
AS REQUIRED , RE: FINISH SCHEDULE.
F47 SCRIBE MIRROR INTO TILE, TYPICAL
F52 INTEGRAL BACK & SIDE SPLASH, RE: FINISH SCHEDULE
F53 SCRIBE PANEL, RE: FINISH SCHEDULE
F55 COPIER, OF/ CI
F57 WALL PROTECTION, RE: FINISH SCHEDULE
F60 SCHLUTER RONDEC - DB FINISHING CAP OR SIMILAR
F61 PORCELAIN WALL TILE AND GLASS ACCENT TILE, SEE D5/A-320.1
FOR MORE INFORMATION.
F74 COUNTER TOP, RE: FINISH SCHEDULE
F89 EXISTING COLUMN LOCATION BEHIND CABINET. COORDINATE
NEW MILLWORK AROUND EXISTING CONDITION.
F90 EXISTING MILLWORK TO REMAIN
F95 PLASTIC LAMINATE CLAD PANELING ON FR WOOD BLOCKING;
PROVIDE WALL BASE AT EXPOSED EDGES.
1/4" = 1'-0"
A3
LARGE EXAM - NORTH
1/4" = 1'-0"
A5
LARGE EXAM - SOUTH
1/4" = 1'-0"
A6
LARGE EXAM -WEST
1/4" = 1'-0"
C6
MSA CORRIDOR - SOUTH
1/4"
= 1'-0"
C4
RECEPTION 120R - NORTH
1/4" = 1'-0"
C5
RECEPTION 120R - SOUTH
1/4" = 1'-0"
B5
TLT - SOUTH
1/4" = 1'-0"
B6
TLT - WEST
1
1
1
1
1
ADDENDUM 1 05/23/17 1
08/28/17