HomeMy WebLinkAboutB17-0092_A-520B.1_1498849080.pdf07 2119 CLOSED-CELL SPRAY
POLYURETHANE FOAM R-21
EXISTING WALL
,TRUNCATE H-SECTION AT
EXISTING STOREFRONT
EXISTING EXTERIOR
WALL
DECORATIVE WINDOW
FILM; LLUMAR BRONZE
NRMB" OR SIM
09 2900 - INTERIOR GYPSUM BOARD,TYPE X
05 4000 - C-H STUD
FRAMING
STOREFRONT MULLION
09 2116.23 - GYPSUM
SHAFTLINER BOARD,
MOISTURE- AND
MOLD-RESISTANT TYPE X
09 2900 - INTERIOR GYPSUM BOARD,TYPE X
09 2900 - CORNERBEAD
SECTION 09 2216 -
NON-STRUCTURAL METAL
FRAMING
SECTION
09 2216 -
NON-STRUCTURAL
METAL
FRAMING
FASTER & SEAM
FASTENING PLATE
BONDING ADHESIVE
FULLY ADHERED SHEET
METAL COUNTER
FLASHING
ROOF TOP MECHANICAL
EQUIPMENT, RE: MECH
EPDM 6" PRESSURE -SENTITIVE
CURB WRAP WITH 6" FACTORY-
APPLIED TAPE
INSULATED METAL
CURB, RE: MECH
FIRE TREATED WOOD
BLOCKING AS REQUIRED.
TREATED WOOD TO BE
COATED AS TO PREVENT
GALVANIC ACTION WITH
FASTENERS AND ADJACENT
METAL SURFACES
MODIFY EXISTING ROOF FOR NEW
MECHANICAL CURB INSTALLATION.
PATCH AND REPAIR ROOF TO
MAINTAIN WARRANTY, FIRE
RESISTIVITY, THERMAL PROPERTIES,
AND WATER RESISTIVITY
EXISTING ROOF ASSEMBLY
CONTINUE ROOF
MEMBRANE
COVER BOARD
PER MFR
INTERMEDIATE FR
WOOD FRAMING;
TREATED WOOD TO
BE COATED AS TO
PREVENT GALVANIC
ACTION WITH
FASTENERS AND
ADJACENT METAL
SURFACES
CONTINUOUS
SEALANT
FLASHING
SECURE ROOF CURB TO
EXISTING METAL DECK
STEEL PLATE OVER FR
BLOCKING
ABOVE
ROOF
MEMBRANE AT LOWEST
ELE
VATION
8" MIN.
CURB
MECHANICAL DUCT,
RE: MECHANICAL
ROOF PIPE SUPPORT
SYSTEM
EXISTING EXTERIOR WALL
SS DUCT CLAMP;
RE: MECHANICAL
SS SELF-TIGHTENING BOLTS
SS THREADED ROD
UNISTRUT
SS SELF-TIGHTENING BOLTS
2" X 2" SS STEEL ANGLE
SS FASTENNERS; COORDINATE
CONDITION WITH EXISTING
WALL FRAMING,
CLADDING, AND JOINT SYSTEM
TO MAINTAIN INTEGRITY OF
CLADDING AND
WEATHER RESISTIVE
ASSEMBLY
5/8" GYPSUM WALL BOARD
CLOSED-CELL SPRAY
POLYURETHANE FOAM R-21
GYPSUM SHAFTLINER BOARD.
MOISTURE AND MOLD RESISTANT, TYPE X
6" C-H STUD FRAMING, TRUNCATE H-
SECTION AT STOREFRONT MULLION
DECORATIVE WINDOW FILM;
"LLUMAR BRONZE NRMB PS2" OR
SIM
STOREFRONT SYSTEM TO MATCH
EXISTING
EXISTING WALL
STOREFRONT SYSTEM TO
MATCH EXISTING
EXISTING WALL
A-740.1
B4
6e86
MECHANICAL
DUCT,
RE: MECHANICAL
PARAPET
BEYOND
TOP OF EXISTING
ROOF ASSMEBLY
MEMBRANE PAD
ADHERED TO
EXISTING ROOF
WITH SPLICE
ADHESIVE; SEAL
PERIMETER WITH
POURABLE SEALER
ROOF PIPE
SUPPORT
METAL ROOF CURB
AND FRAMING
SECURED TO
EXISTING
STRUCTURAL DECK
CONTINUOUS LAP
SEALANT
FULLY ADHERED
FLASHING
MEMBRANE
CONTINUOUS BEAD
OF LAP SEALANT
GC TO VIF
PER MFR,
BUT
NOT
LESS
THAN 8"
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:38:02 PM
15924.00
A-520B.1
EXTERIOR DETAILS
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1 1/2" = 1'-0"
A2
IP PHARMACY -PLAN DETAIL
1 1/2" = 1'-0"
D5
ROOF CURB DETAIL
1
1/2" = 1'-0" D4
EXTERIOR DUCT SUPPORT DETAIL AT PARAPET
1 1/2" = 1'-0"
A5
IP PHARMACY - NORTH EXTERIOR WALL PLAN
DETAIL
1 1/2" = 1'-0" B5
ROOF PENETRATION SECTION DETAIL
06/30/17