HomeMy WebLinkAboutB17-0092_A-520B.1_1503950456.pdf07 2119 - THERMAL INSULATION WITH
SPRAY APPLICATION, R-21 MINIMUM
EXISTING WALL
,TRUNCATE H-SECTION AT
EXISTING STOREFRONT
EXISTING EXTERIOR
WALL
DECORATIVE WINDOW
FILM; LLUMAR BRONZE
NRMB" OR SIM
09 2900 - INTERIOR GYPSUM BOARD,TYPE X
05 4000 - C-H STUD
FRAMING
STOREFRONT MULLION
09 2116.23 - GYPSUM
SHAFTLINER BOARD,
MOISTURE- AND
MOLD-RESISTANT TYPE X
09 2900 - INTERIOR GYPSUM BOARD,TYPE X
SECTION 09 2216 -
NON-STRUCTURAL
METAL FRAMING
SECTION
09 2216 -
NON-STRUCTURAL
METAL
FRAMING
1
1
FASTER & SEAM
FASTENING PLATE
BONDING ADHESIVE
FULLY ADHERED SHEET
METAL COUNTER
FLASHING
ROOF TOP MECHANICAL
EQUIPMENT, RE: MECH
EPDM 6" PRESSURE -
SENTITIVE CURB WRAP
WITH 6" FACTORY-
APPLIED TAPE
INSULATED METAL
CURB, RE: MECH
FIRE TREATED WOOD
BLOCKING AS REQUIRED.
TREATED WOOD TO BE
COATED AS TO PREVENT
GALVANIC ACTION WITH
FASTENERS AND
ADJACENT METAL
SURFACES
MODIFY EXISTING ROOF FOR NEW
MECHANICAL CURB INSTALLATION.
PATCH AND REPAIR ROOF TO
MAINTAIN WARRANTY, FIRE
RESISTIVITY, THERMAL PROPERTIES,
AND WATER RESISTIVITY
EXISTING ROOF ASSEMBLY
CONTINUE ROOF
MEMBRANE
COVER BOARD
PER MFR
INTERMEDIATE FR WOOD
FRAMING; TREATED WOOD
TO BE COATED AS TO
PREVENT GALVANIC
ACTION WITH FASTENERS
AND ADJACENT METAL
SURFACES
CONTINUOUS
SEALANT
FLASHING
SECURE ROOF CURB TO
EXISTING METAL DECK.
RE: STRUCTURAL.
ABOVE
ROOF
MEMBRANE AT LOWEST ELEVATION
8" MIN.
CURB
MECHANICAL DUCT, RE:
MECHANICAL
ROOF PIPE
SUPPORT SYSTEM
EXISTING EXTERIOR WALL
PIPE CLAMP;
RE: MECHANICAL
SS SELF-TIGHTENING BOLTS
1/4" CAP PLATE; RE: STRUCT.
STEEL ANGLE, SEE
STRUCTURAL;
SEAL ALL SIDES WITH
THERMAX "LIQUID ARMOR";
SEAL PENETRATION AT
WEATHER BARRIER
FASTENERS;
STEEL ANGLE, SEE
STRUCTURAL;
SEAL ALL SIDES WITH
THERMAX "LIQUID ARMOR";
SEAL PENETRATION AT
WEATHER BARRIER
PROVIDE ONE
FRAME EACH
SIDE OF DUCT;
RE: STRUCT.
NOTE: COORDINATE CONDITION WITH
EXISTING WALL FRAMING,CLADDING,
AND JOINT SYSTEM TO MAINTAIN
INTEGRITY OF CLADDING AND
WEATHER RESISTIVE ASSEMBLY,
TYPICAL.
5/8" GYPSUM WALL
07 2119 - THERMAL INSULATION WITH
SPRAY APPLICATION, R-21 MINIMUM
GYPSUM SHAFTLINER BOARD.
MOISTURE AND MOLD RESISTANT, TYPE X
6" C-H STUD FRAMING, TRUNCATE H-
SECTION AT STOREFRONT MULLION
DECORATIVE WINDOW FILM;
"LLUMAR BRONZE NRMB PS2" OR
SIM
EXISTING WALL
A-740.1
B4
1
1 1 1
GC TO VERIFY WALL AND JOINT
CONDITION TO MATCH FIRE RESISTIVITY
PER LIFE SAFETY PLANS 1
1
6e86
MECHANICAL
DUCT,
RE:
MECHANICAL
PARAPET
BEYOND
TOP OF EXISTING
ROOF ASSMEBLY
MEMBRANE PAD
ADHERED TO
EXISTING ROOF
WITH SPLICE
ADHESIVE; SEAL
PERIMETER WITH
POURABLE
SEALER
ROOF PIPE
SUPPORT
METAL ROOF
CURB AND
FRAMING
SECURED TO
EXISTING
STRUCTURAL
DECK
CONTINUOUS LAP
SEALANT
FULLY ADHERED
FLASHING
MEMBRANE
CONTINUOUS
BEAD OF LAP
SEALANT
GC TO VIF
PER MFR,
BUT
NOT
LESS
THAN 8"
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
7/11/2017
10:25:35 AM
15924.00
A-520B.1
EXTERIOR DETAILS
2017
07/11/17
PERMIT
RESUBMISSION
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1 1/2" = 1'-0" A2
IP PHARMACY -PLAN DETAIL
1 1/2" = 1'-0"D5
ROOF CURB DETAIL
1 1/2" = 1'-0"
D4
EXTERIOR DUCT SUPPORT DETAIL AT PARAPET
1 1/2" = 1'-0"
A5
IP PHARMACY - NORTH EXTERIOR WALL PLAN DETAIL
1 1/2" = 1'-0" B5
ROOF PENETRATION SECTION DETAIL
1
ADDENDUM 1 05/23/17 1
08/28/17