Loading...
HomeMy WebLinkAboutB17-0092_A-520B.1_1503950456.pdf07 2119 - THERMAL INSULATION WITH SPRAY APPLICATION, R-21 MINIMUM EXISTING WALL ,TRUNCATE H-SECTION AT EXISTING STOREFRONT EXISTING EXTERIOR WALL DECORATIVE WINDOW FILM; LLUMAR BRONZE NRMB" OR SIM 09 2900 - INTERIOR GYPSUM BOARD,TYPE X 05 4000 - C-H STUD FRAMING STOREFRONT MULLION 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 09 2900 - INTERIOR GYPSUM BOARD,TYPE X SECTION 09 2216 - NON-STRUCTURAL METAL FRAMING SECTION 09 2216 - NON-STRUCTURAL METAL FRAMING 1 1 FASTER & SEAM FASTENING PLATE BONDING ADHESIVE FULLY ADHERED SHEET METAL COUNTER FLASHING ROOF TOP MECHANICAL EQUIPMENT, RE: MECH EPDM 6" PRESSURE - SENTITIVE CURB WRAP WITH 6" FACTORY- APPLIED TAPE INSULATED METAL CURB, RE: MECH FIRE TREATED WOOD BLOCKING AS REQUIRED. TREATED WOOD TO BE COATED AS TO PREVENT GALVANIC ACTION WITH FASTENERS AND ADJACENT METAL SURFACES MODIFY EXISTING ROOF FOR NEW MECHANICAL CURB INSTALLATION. PATCH AND REPAIR ROOF TO MAINTAIN WARRANTY, FIRE RESISTIVITY, THERMAL PROPERTIES, AND WATER RESISTIVITY EXISTING ROOF ASSEMBLY CONTINUE ROOF MEMBRANE COVER BOARD PER MFR INTERMEDIATE FR WOOD FRAMING; TREATED WOOD TO BE COATED AS TO PREVENT GALVANIC ACTION WITH FASTENERS AND ADJACENT METAL SURFACES CONTINUOUS SEALANT FLASHING SECURE ROOF CURB TO EXISTING METAL DECK. RE: STRUCTURAL. ABOVE ROOF MEMBRANE AT LOWEST ELEVATION 8" MIN. CURB MECHANICAL DUCT, RE: MECHANICAL ROOF PIPE SUPPORT SYSTEM EXISTING EXTERIOR WALL PIPE CLAMP; RE: MECHANICAL SS SELF-TIGHTENING BOLTS 1/4" CAP PLATE; RE: STRUCT. STEEL ANGLE, SEE STRUCTURAL; SEAL ALL SIDES WITH THERMAX "LIQUID ARMOR"; SEAL PENETRATION AT WEATHER BARRIER FASTENERS; STEEL ANGLE, SEE STRUCTURAL; SEAL ALL SIDES WITH THERMAX "LIQUID ARMOR"; SEAL PENETRATION AT WEATHER BARRIER PROVIDE ONE FRAME EACH SIDE OF DUCT; RE: STRUCT. NOTE: COORDINATE CONDITION WITH EXISTING WALL FRAMING,CLADDING, AND JOINT SYSTEM TO MAINTAIN INTEGRITY OF CLADDING AND WEATHER RESISTIVE ASSEMBLY, TYPICAL. 5/8" GYPSUM WALL 07 2119 - THERMAL INSULATION WITH SPRAY APPLICATION, R-21 MINIMUM GYPSUM SHAFTLINER BOARD. MOISTURE AND MOLD RESISTANT, TYPE X 6" C-H STUD FRAMING, TRUNCATE H- SECTION AT STOREFRONT MULLION DECORATIVE WINDOW FILM; "LLUMAR BRONZE NRMB PS2" OR SIM EXISTING WALL A-740.1 B4 1 1 1 1 GC TO VERIFY WALL AND JOINT CONDITION TO MATCH FIRE RESISTIVITY PER LIFE SAFETY PLANS 1 1 6e86 MECHANICAL DUCT, RE: MECHANICAL PARAPET BEYOND TOP OF EXISTING ROOF ASSMEBLY MEMBRANE PAD ADHERED TO EXISTING ROOF WITH SPLICE ADHESIVE; SEAL PERIMETER WITH POURABLE SEALER ROOF PIPE SUPPORT METAL ROOF CURB AND FRAMING SECURED TO EXISTING STRUCTURAL DECK CONTINUOUS LAP SEALANT FULLY ADHERED FLASHING MEMBRANE CONTINUOUS BEAD OF LAP SEALANT GC TO VIF PER MFR, BUT NOT LESS THAN 8" 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:25:35 AM 15924.00 A-520B.1 EXTERIOR DETAILS 2017 07/11/17 PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1 1/2" = 1'-0" A2 IP PHARMACY -PLAN DETAIL 1 1/2" = 1'-0"D5 ROOF CURB DETAIL 1 1/2" = 1'-0" D4 EXTERIOR DUCT SUPPORT DETAIL AT PARAPET 1 1/2" = 1'-0" A5 IP PHARMACY - NORTH EXTERIOR WALL PLAN DETAIL 1 1/2" = 1'-0" B5 ROOF PENETRATION SECTION DETAIL 1 ADDENDUM 1 05/23/17 1 08/28/17