Loading...
HomeMy WebLinkAboutB17-0092_A-550.1_1498849080.pdfSURFACE MOUNTED BRUSHED STAINLESS STEEL CORNER GUARD 22" GAUGE SHEET METAL BACKING METAL STUDS 5/8" TYPE 'X' GYP. BD. TYP. SURFACE MOUNTED BRUSHED STAINLESS STEEL CORNER GUARD 22" GAUGE SHEET METAL BACKING METAL STUDS 5/8" TYPE 'X' GYP. BD. TYP. 2" 2" 09 3013 - CERAMIC TILE 09 6813 - METAL EDGE/TRANSITION STRIP 09 6813 - CARPET TILE NOTE: TRANSITION PROFILE TO BE 'SCHLUTER SCHIENE 6 12.5MM H; ALUM FINISH' OR SIM SECTION 09 6516 - RESILIENT SHEET FLOORING 09 6813 - METAL EDGE/TRANSITION STRIP 09 6813 - CARPET TILE NOTE: TRANSITION PROFILE TO BE 'SCHLUTER SCHIENE 2 12.5MM H; ALUM FINISH' OR SIM 09 6513 - RESILIENT BASE SECTION 09 6516 - RESILIENT SHEET FLOORING BASE HEIGHT 09 2900 - INTERIOR GYPSUM BOARD COVE FORMER 09 6513 - RESILIENT BASE BASE HEIGHT WALL COVERING J-TRIM WALL COVERING, RE: FINISH SCHEDULE CONTINUOUS SEALANT COVE FORMER CAP TRIM AS SPECIFIED SECTION 09 6516 - RESILIENT SHEET FLOORING PER MANUFACTURER AS SCHEDULED 4" MAX 5/8" GYP. BOARD ON METAL STUDS 5/8" GYP. BOARD ON METAL STUDS NOTE: CONTRACTOR TO PROVIDE RATED ENCLOSURE IN RATED PARTITION OR PROVIDE RATED CABINET. / E2A-550.1 AS SCHEDULED FIELD VERIFY HEIGHT AND WIDTH VERTICAL SECTION 5/8" GYP. BOARD ON METAL STUDS 3'-6" A.F.F. NOTE: MAINTAIN THE INTEGRITY OF THE PARTITION TYPE FIRE RATING. NOTE: CABINET ENCLOSURE IN FIRE RATED PARTITION TO HAVE RATED CABINET. /E3 A-550.1 PER 2010 NFPA 10, SECTION 6.1.3.8, IF WEIGHT > 40 LBS, X=5'-0" IF WEIGHT < 40 LBS, X=3'-6" PORCELAIN FLOOR TILE (VARIES; RE: FINISH PLANS) RESILIENT FLOORING (VARIES; RE: FINISH PLANS) FLOOR TRANSITION NOTE: TRANSITION PROFILE TO BE 'SCHLUTER, RENO-U 8-10MM HEIGHT, ALUM FINISH' OR SIM NOTE: TYPICAL AT ALL RESILIENT FLOORING TO SEALED CONCRETE FLOOR TRANSITIONS. NOTE: TRANSITION PROFILE TO BE 'SCHLUTER, RENO-U 3.5MM – 1/8” HEIGHT, ALUM FINISH' OR SIM. RESILIENT FLOORING RE: FINISH LEGEND ADA COMPLIANT TRANSITION FINISH SEALED CONCRETE NEW FINISH AS SCHEDULED EXISTING FINISH FLOOR TRANSITION NOTE: TYPICAL AT ALL RESILIENT FLOORING TO SEALED CONCRETE FLOOR TRANSITIONS. NOTE: TRANSITION PROFILE TO BE 'SCHLUTER, RENO T; ALUMINIUM FINISH" OR SIM. 09 5113 - ACOUSTICAL PANEL CEILING 09 5113 - METAL SUSPENSION SYSTEM 10 2123 - CUBICLE CURTAIN TRACK 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 3:38:05 PM 15924.00 A-550.1 INTERIOR DETAILS 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 6" = 1'-0"E6 CORNER GUARD 6" = 1'-0" E5 CORNER GUARD AT WING WALL 12" = 1'-0" A5 FLOOR TRANSITION - PFT TO CPT 12" = 1'-0" A6 FLOOR TRANSITION - RESILIENT TO CPT 12" = 1'-0" B4 INTEGRAL BASE 12" = 1'-0" B5 INTEGRAL BASE TO WALL PROTECTION 1 1/2" = 1'-0" E3 FEC - PLAN 1 1/2" = 1'-0" E2 FEC - SECTION 12" = 1'-0"A4 FLOOR TRANSITION - RESILIENT TO PFT 12" = 1'-0" A3 FLOOR TRANSITION - RESILIENT TO SC 12" = 1'-0" A2 FLOOR TRANSITION - EXISTING TO NEW 6" = 1'-0" E1 CURTAIN TRACK 06/30/17