HomeMy WebLinkAboutB17-0092_A-550.1_1503950456.pdfSURFACE MOUNTED BRUSHED STAINLESS STEEL 22" GAUGE SHEET METAL STUDS 5/8" TYPE 'X' GYP. BD. SURFACE MOUNTED BRUSHED STAINLESS STEEL 22" GAUGE SHEET METAL STUDS 5/8" TYPE 'X' GYP. BD. 2" 2" 09 3013 - CERAMIC TILE 09 6813 - METAL EDGE/TRANSITION STRIP 09 6813 - CARPET TILE NOTE: TRANSITION PROFILE TO BE 'SCHLUTER SCHIENE 6 12.5MM H; ALUM FINISH' OR SIM SECTION 09 6516 - RESILIENT SHEET FLOORING 09 6813 - METAL EDGE/TRANSITION STRIP 09 6813 - CARPET TILE NOTE: TRANSITION PROFILE TO BE 'SCHLUTER SCHIENE 2 12.5MM H; ALUM FINISH' OR SIM 09 6513 - RESILIENT BASE SECTION 09 6516 - RESILIENT SHEET FLOORING BASE HEIGHT 09 2900 - INTERIOR GYPSUM BOARD COVE 09 6513 - RESILIENT BASE BASE HEIGHT WALL COVERING J- WALL COVERING, RE: FINISH CONTINUOUS COVE CAP TRIM AS SECTION 09 6516 - RESILIENT SHEET FLOORING PER MANUFACTURER AS SCHEDULED 4" MAX 5/8" GYP. BOARD ON METAL STUDS 5/8" GYP. BOARD ON METAL STUDS NOTE: CONTRACTOR TO PROVIDE RATED ENCLOSURE IN RATED PARTITION OR PROVIDE RATED CABINET. / E2A-550.1 AS SCHEDULED FIELD VERIFY HEIGHT AND WIDTH VERTICAL 5/8" GYP. BOARD ON METAL STUDS 3'-6" A.F.F. NOTE: MAINTAIN THE INTEGRITY OF THE PARTITION TYPE FIRE RATING. NOTE: CABINET ENCLOSURE IN FIRE RATED PARTITION TO HAVE RATED CABINET. /E3 A-550.1 PER 2010 NFPA 10, SECTION 6.1.3.8, IF WEIGHT > 40 LBS, X=5'-0" IF WEIGHT < 40 LBS, X=3'-6" PORCELAIN FLOOR TILE (VARIES; RE: FINISH PLANS) RESILIENT FLOORING (VARIES; RE: FINISH PLANS) FLOOR TRANSITION NOTE: TRANSITION PROFILE TO BE 'SCHLUTER, RENO-U 8-10MM HEIGHT, ALUM FINISH' OR SIM NOTE: TYPICAL AT ALL RESILIENT FLOORING TO SEALED CONCRETE FLOOR TRANSITIONS. NOTE: TRANSITION PROFILE TO BE 'SCHLUTER, RENO-U 3.5MM – 1/8” HEIGHT, ALUM FINISH' OR SIM. RESILIENT FLOORING RE: FINISH LEGEND ADA COMPLIANT TRANSITION FINISH SEALED CONCRETE NEW FINISH AS SCHEDULED EXISTING FINISH FLOOR TRANSITION NOTE: TYPICAL AT ALL RESILIENT FLOORING TO SEALED CONCRETE FLOOR TRANSITIONS. NOTE: TRANSITION PROFILE TO BE 'SCHLUTER, RENO T; ALUMINIUM FINISH" OR SIM. 09 5113 - ACOUSTICAL PANEL CEILING 09 5113 - METAL SUSPENSION SYSTEM 10 2123 - CUBICLE CURTAIN TRACK MATCH EXISTING CONDITIONS 2' - 2" PARTITION AS SCHEDULED COLD FORMED METAL FRAMING CEILING AS SCHEDULED CONTINUOUS CORNER BEAD DRYWALL CEILING PANEL ON METAL FRAMING COLD FORMED METAL FRAMING EXISTING EXTERIOR WALL ASSEMBLY EXISTING STOREFRONT SYSTEM 6" EGRESS LIGHT, SEE ELECT. RE: RCP STUD BRACING BEYOND 05 4000 - STEEL STUD 09 2900 - INTERIOR GYPSUM BOARD 05 4000 - STEEL STUD SCHEDULED CEILING 09 2900 - CORNERBEAD B.O. SOFFIT 7' - 0" B.O. CEILING 8' - 0" 6" B.O. CEILING 7' - 0" B.O. CEILING 8' - 0" 6" 09 2900 - INTERIOR GYPSUM BOARD 05 4000 - STEEL STUD SCHEDULED CEILING 09 2900 - CORNERBEAD 05 4000 - STEEL STUD RE: RCP LEVEL 1 100' - 0" 3/4" EXISTING PARTITION 06 - 2000 - CHAIR RAIL; PROFILE AND LOCATION TO MATCH EXISTING 3" VERIFY WITH OWNER - TO ALIGN WITH OFOI CHAIRS 2' - 8" LEVEL 1 100' - 0" EXISTING PARTITION REMOVE EXISTING CHAIR RAIL. PATCH WALL WHERE NEW NOT INDICATED ON PLAN. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:25:39 AM 15924.00 A-550.1 INTERIOR DETAILS 2017 07/11/17 PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 6" = 1'-0"E6 CORNER GUARD 6" = 1'-0" E5 CORNER GUARD AT WING WALL 12" = 1'-0" A5 FLOOR TRANSITION - PFT TO CPT 12" = 1'-0" A6 FLOOR TRANSITION - RESILIENT TO CPT 12" = 1'-0" B4 INTEGRAL BASE 12" = 1'-0" B5 INTEGRAL BASE TO WALL PROTECTION 1 1/2" = 1'-0" E3 FEC - PLAN 1 1/2" = 1'-0" E2 FEC - SECTION 12" = 1'-0"A4 FLOOR TRANSITION - RESILIENT TO PFT 12" = 1'-0" A3 FLOOR TRANSITION - RESILIENT TO SC 12" = 1'-0" A2 FLOOR TRANSITION - EXISTING TO NEW 6" = 1'-0" E1 CURTAIN TRACK 1 1/2" = 1'-0" C1 RCP SECTION DETAIL AT EXTERIOR WALL 1 1 1/2" = 1'-0" C3 RCP SECTION DETAIL AT SOFFIT 1 1/2" = 1'-0" C4 RCP SECTION DETAIL AT SOFFIT 1 1/2" = 1'-0"B3 SECTION DETAIL AT CONFERENCE ROOM 1 1/2" = 1'-0" B1 DEMO SECTION DETAIL AT CONFERENCE ROOM 3 3 ADDENDUM 1 05/23/17 1 RFC0007 06/13/17 2 ADDENDUM 3 06/27/17 3 08/28/17