HomeMy WebLinkAboutB17-0092_A-621A.1_1498849080.pdfDe01 Ce01 Be01 Ee01 Fe01 Ge01 He01 Je01
2e01
3e01
4e01
5e01
6e01
OFFICE
111
OFFICE
121
OFFICE
120
OFFICE
117
NUCLEAR
MEDICINE
CAMERA
105A
CONTROL
104A
HOT LAB
104B
INJECTION
104D
SOILED HOLD
105B
ESR
105C
PT TOILET
104C
CORRIDOR
100B
OFFICE
128A
ULTRASOUND
113
COPY
125
OFFICE
126
STORAGE
118A
CORRIDOR
118
BREAK
127
OFFICE
116B
OFFICE
116A
CONFERENCE
ROOM
123
OFFICE
122
OFFICE
119
OFFICE
112
CORRIDOR
109
RECEPTION
102
TLT
104
STORAGE
108
OFFICE
114
OFFICE
106
SPRINKLER ROOM
106A
CG
CG
CG
CG
NEW SECTION OF WALL
AND WALLBASE FINISH
TO MATCH EXISTING ADJACENT
NEW SECTION OF WALL
AND WALLBASE FINISH
TO MATCH EXISTING ADJACENT
NEW SECTION OF WALL
AND WALLBASE FINISH
TO MATCH EXISTING ADJACENT
STORAGE
127A
OFFICE
128B
CORRIDOR
100
STAFF RECESS
101
FIN01
FIN02
FIN03 FIN04
FIN03
FIN03
FIN03
FIN03
FIN04
FIN04
FIN04
FIN03 FIN04
CR1 CR1
CR
CR
CR
CG
CG
CG
CG
CG
CG
CG
CG
FINISH SYMBOL LEGEND
P_
FINISH EXTENTS
WALL PROTECTION, WP1
CORNER GUARD (CG1)
FINISH TAG
ROOM NAME
####
XX#
ROOM TAG WITH
FINISH INDICATOR
CPT1
PFT1
LVT1
SV1
CPT2
SV2
SV3
SV4
1. PAINT ALL GYP. WALLS P1 U.N.O.
2. ALL PAINT FINISHES TO BE SATIN: (2) COATS OVER (1)
COAT PRIMER, U.N.O.
3. ALL FLOOR FINISH CHANGES TO BE AT CENTER OF
DOORWAYS U.N.O. NO SEAMS INFRONT OF DOOR
WAYS.
4. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL
WALL FINISH INFORMATION AND EXTENT OF FINISHES.
5. ALL RUBBER REDUCER STRIPS AT FLOOR
TRANSITIONS TO BE ADA PROFILE. COLOR TO MATCH
RUBBER BASE, U.O.N.
6. ALL EXPOSED GRILLS, REGISTERS, DIFFUSERS,
ACCESS PANELS, AND SPECIAL DOORS TO BE PAINTED
TO MATCH THE SURFACE ON WHICH THEY OCCUR
U.N.O.
7. ALL PAINT COLORS TO BE MOCKED-UP ON-SITE ON
ONE ENTIRE FULL HEIGHT WALL FOR OWNER
APPROVAL PRIOR TO ORDERING PRODUCT.
8. ALL GYP. CEILINGS TO BE PAINTED; PROVIDE MOLD
RESISTANT EPOXY PAINT AT CEILINGS IN TOILET AND
SHOWER ROOMS AND WET AREAS AS NOTED.
9. ALL CEILING GRID WALL ANGLES TO BE SEALANT AT
WALL WHERE PAINT OCCURS.
10. FINISH AND PAINT ALL SIDES OF SOFFIT OR GYP.
CEILING. REFER TO REFLECTED CEILING PLAN FOR
CEILING PAINT ACCENTS. WHEN ACCENT PAINT IS
CALLED OUT ON SOFFIT- ALL SIDES, FACES, EDGES,
ETC TO RECIEVE ACCENT PAINT.
11. ALL SHEET VINYL SEAMS TO BE HEAT WELDED.
12. ALL CASEWORK/MILLWORK COUNTERTOPS WITH
SINKS TO BE SOLID SURFACE (SS) U.N.O.
13. 4" HIGH RUBBER BASE WHERE SCHEDULED, U.O.N.
14. WINDOW TREATMENTS: EXTERIOR WINDOWS
REQUIRE MINI-BLINDS. REFER TO FINISH LEGEND FOR
FURTHER INFO.
15. PROVIDE GROUT SAMPLES FOR ARCHITECT'S
SELECTION. GROUT IN WET AREAS TO BE EPOXY.
16. PAINT ALL INTERIOR METAL PT2. SEE
SPECIFICATIONS
FOR PAINT FINISH.
17. WHERE NOTED, ACROVYN SHEET WALL PRETECTION
TO BE 48" AFF.
18. WHERE NOTED, 2" BRUSHED STANLESS STEEL
CORNER GURARDS TO BE 48" AFF. CORNER GUARDS
TO BE GLUED AND NOT SCREWED INTO DRYWALL.
19. FURNITURE SHOWN DASHED, TO BE PURCHASED
BY OWNER.
20. EXISTING WALLCOVERING TO BE REMOVED U.O.N.
EXPOSED WALLS TO BE SKIM COATED SMOOTH AND
PREPARED TO BE PAINTED NEW.
21. EXISTING CHAIR RAIL TO REMAIN, U.O.N. AND
PROTECTED FREE FROM DIRT AND DAMAGE DURING
INTERIOR RENOVATION.
22. EXISTING WOOD WALL BASE TO REMAIN U.O.N. AND
PROTECTED FREE FROM DIRT AND DAMAGE DURING
INTERIOR RENOVATION.
23. REFER TO REFLECTED CEILING PLANS FOR EXTENT
OF NEW CEILING TILE AND GRID, NEW CEILING TILE
AND/OR GRID TO MATCH EXISTING, AND EXISTING
CEILING TILE AND/OR GRID TO REMAIN.
GENERAL FINISH NOTES
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:38:30 PM
15924.00
A-621A.1
ENLARGED FINISH FLOOR
PLAN - AREA A
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
1/4" = 1'-0" A1
ENLARGED FLOOR PLAN AREA A
02 - 100 - KEYNOTE LEGEND - FINISH FLOOR PLAN
FIN01 NEW FLOOR, WALL BASE, AND WALL FINISHES TO MATCH
ADJACENT EXISTING IN MATERIAL AND COLOR.
FIN02 EXISTING WALLCOVERING TO REMAIN AND PROTECTED FREE
FROM DIRT AND DAMAGE DURING RENOVATION.
FIN03 NEW WOOD WALL BASE TO MATCH EXISTING.
FIN04 NEW CHAIR RAIL TO MATCH EXISTING.
06/30/17