Loading...
HomeMy WebLinkAboutB17-0092_A-720.1_1498849080.pdfSINGLE FLUSH F1 RE: SCHEDULERE: SCHED. DOUBLE FLUSH UNEVEN F5 RE: SCHEDULE 4' - 0" 2' - 0" RE: SCHEDULE SINGLE NARROW LITE (TEMPERED OR FIRE RATED GLASS) N1 RE: SCHEDULE RE SCHED. 3' - 4" 8" 8" 8" RE: SCHEDULE RE: SCHED. SINGLE FULL GLAZED (TEMPERED OR FIRE RATED GLASS) FG1 6" 6" 6" 1' - 0" SINGLE HALF LITE (TEMPERED OR FIRE RATED GLASS) HG1 RE: SCHEDULE RE: SCHED. 6" 6" 3' - 0" 6" DOUBLE FLUSH F3 RE: SCHEDULE RE: SCHEDULE EQ EQ SINGLE NARROW LITE (TEMPERED OR FIRE RATED GLASS) N2 RE: SCHED. EQ EQ 8" 3' - 4" 8" 8" 8" 8" RE: SCHEDULE SINGLE FLUSH WITH PEEP HOLE P1 RE: SCHEDULERE: SCHED. 3' - 6" 1' - 6" EQ EQ RE: SCHEDULE RE: SCHED. DOUBLE FULL GLAZED (TEMPERED OR FIRE RATED GLASS) FG2 6"6" 6" 1' - 0" 6" 6" D0a D0b 4 7/8" 5/8" 3 5/8" 5/8" D0p 4 7/8" 5/8" 3 5/8" 5/8" D1sX 4 7/8" 5/8" 3 5/8" 5/8" D0s 4 7/8" 5/8" 3 5/8" 5/8" D1s 4 7/8" 5/8" 3 5/8" 5/8" J1b 5/8" 2 1/2" 3" D0f 4 1/4" 3 5/8" 5/8" 4 7/8" 5/8" 3 5/8" 5/8" D0bX 4 7/8" 5/8" 3 5/8" 5/8" L0k 5/8" 6" 6 5/8" 7 1/4" 5/8" 6" 5/8" F0s D0sX 4 7/8" 5/8" 3 5/8" 5/8" SINGLE OR DOUBLE DOOR FRAME HM01 RE: SCHEDULE 2" 2" RE: SCHED. 2" / A2A-720.1 /A1 A-720.1 DOOR / FRAME MATERIAL: AL/G - ALUMINUM GLASS HM - HOLLOW METAL WD - WOOD P - PAINTED STAIN - STAINED MFR - MANUFACTURER DOOR FINISH: PL# - PLASTIC LAMINATE ST - STAINED CA - CLEAR ANODIZED P - PAINTED KF - KYNAR FINISH GL - GLASS DOOR NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS. 2. REFER TO SPECIFICATIONS FOR HARDWARE TYPES AND SCHEDULE. 3. ALL FIRE RATED DOORS SHALL HAVE UNDERWRITERS LABEL ON DOOR AND FRAME. 4. WHERE EXISTING DOORS TO REMAIN, TOUCH UP SCUFFING TO MAKE DOOR FINISH LIKE-NEW. 5. AT EXISTING DOORS IN SCOPE: WHERE SCUFFED,PATCH AND REFINISH TO LIKE-NEW CONDITION DOOR AND HARDWARE SCHEDULE - ABBREVIATIONS LEGEND/NOTES FRAME NOTES 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS PRIOR TO ORDERING OR FABRICATING ANY FRAMES. 2. ALL ELEVATIONS ARE DRAWN FACING THE EXTERIOR OF THE WINDOW FRAME. 3. STOREFRONT FABRICATOR TO PROVIDE REINFORCING AS REQUIRED 4. ALL DIMENSIONS ARE TO MASONRY OR ROUGH OPENING UNLESS NOTED OTHERWISE, PROVIDE PROPER SHIM CLEARANCE AS REQUIRED. 5. AT EXISTING FRAMES IN SCOPE: WHERE SCUFFED, PATCH AND REFINISH TO LIKE- NEW CONDITION GLAZING TYPES S = PROVIDE TEMPERED GLASS IN NON-RATED DOORS WHERE INDICATED. F = PROVIDE FIRE- PROTECTION-RATED GLASS MEETING OR EXCEEDING THE RATING OF THE DOOR ASSEMBLY WHERE INDICATED SEE SPECIFICATION FOR ACCEPTABLE GLASS TYPES. UNO 6" TYP. TYPE RE: PARTITION SECTION 09 2900 - GYPSUM BOARD 08 1416 - FLUSH WOOD DOOR 08 1113 - INTERIOR HOLLOW-METAL FRAME 05 4000 - COLD-FORMED METAL FRAMING 07 9200 - JOINT SEALANT07 9200 - JOINT SEALANT TYPE RE: PARTITION SECTION 09 2900 - GYPSUM BOARD 08 1113 - INTERIOR HOLLOW-METAL FRAME 08 1416 - FLUSH WOOD DOOR 07 9200 - JOINT SEALANT 05 4000 - COLD-FORMED METAL FRAMING INTERIOR PARTITION TYPES STRUCTURE A 7/8" HAT CHANNEL B 1 5/8" METAL STUD C 2 1/2" METAL STUD D 3 5/8" METAL STUD E 4" METAL STUD F 6" METAL STUD G 3 5/8" DOUBLE METAL STUD J 2 1/2" C-H METAL STUD K 4" C-H METAL STUD L 6" C-H METAL STUD M 2x4 WOOD STUD N 2x6 WOOD STUD P 4" CMU Q 6" CMU R 8" CMU S 12" CMU Z 1 1/2" "Z" FURRING CHANNEL D1sX EXAMPLE D = 3 5/8" METAL STUD 1 = 1 HOUR FIRE RESISTANCE RATING s = SOUND PARTITION X = SMOKE RATED PARTITION FIRE RESISTANCE RATING* 0 NON-RATED 1 1 HOUR 2 2 HOUR 3 3 HOUR 4 4 HOUR SUB-TYPE a 6" ABOVE CEILING b UNDERSIDE OF STRUCTURE c UNDER SIDE OF CEILING f FURRING l LEAD LINED k SECURITY MESH p PARTIAL HEIGHT s SOUND PARTITION t THERMAL INSULATION v SOUND PARTITION WITH (2) LAYERS GYPSUM BOARD EACH SIDE w SOUND PARTITION WITH (2) LAYERS GYPSUM BOARD ONE SIDE (1) LAYER OTHER SIDE z TILE BACKER BOARD SMOKE RATED* X SMOKE PARTITION, SMOKE BARRIER OR WALL RESISTING THE PASSAGE OF SMOKE STRUCTURE FIRE RESISTANCE RATING SUB-TYPE SMOKE RATED (OPTIONAL) * SEE RATED PARTITION NOTE 2 GENERAL CONSTRUCTION AND LAYOUT NOTES 1. THE INTERIOR FRAMING SUBCONTRACTOR SHALL PROVIDE A DELEGATED ENGINEERED STUD DESIGN FOR ALL NON-STRUCTURAL METAL FRAMING FOR WALLS AND CEILINGS. SUBMIT FRAMING SHOP DRAWINGS WITH DETAILS, PRODUCT SELECTIONS, AND ENGINEERING CALCULATIONS STAMPED BY A LICENSED ENGINEER IN THE PROJECT JURISDICTION. ENGINEERING SHALL INCLUDE PROVISIONS FOR ELEMENTS ATTACHED TO/SUPPORTED BY THE FRAMING. FASTENER DESIGN AND SELECTION IS ALSO REQUIRED. SUBMIT ICC ES EVALUATION REPORTS FOR EACH FASTENER. USE OF DIMPLED OR PERFORMANCE ENHANCED SHAPED STUDS IS ACCEPTABLE. UNLESS OTHERWISE INDICATED DESIGN FOR A MAXIMUM DEFLECTION OF L/240 AT 5 PSF. AT PARTITIONS TO RECEIVE CERAMIC TILE DESIGN FOR A MAXIMUM DEFLECTION OF L/360 AT 5 PSF. REGARDLESS OF DESIGN, PROVIDE 20 GA STUD AT A MINIMUM. 2. ALL INTERIOR PARTITIONS ARE DIMENSIONED TO FINISHED FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE. 3. ALL STUDS SHALL BE FULL HEIGHT TO UNDERSIDE OF STRUCTURE UNLESS INDICATED OTHERWISE BY PARTITION TYPE. 4. BOTTOM OF GYPSUM BOARD SHALL BE 1/4” TO 3/8” ABOVE FINISH FLOOR UNLESS OTHERWISE INDICATED. 5. OFFSET STUDS AS NECESSARY TO ALIGN OUTSIDE FACES OF GYPSUM BOARD AT ADJACENT WALL TYPES WITH VARYING LAYERS OF GYPSUM BOARD. 6. PROVIDE DEEP LEG TRACKS (3" FLANGE) AT HEAD OF PARTITIONS AT ALL NON-LOAD BEARING PARTITIONS FOR EACH CONDITION THAT ALLOW FOR 1" OF UPWARD MOVEMENT AND 1" OF DOWNWARD DYNAMIC MOVEMENT CAPABILITIES. 7. AT SLAB-ON-GRADE CONDITIONS PROVIDE DYNAMIC MOVEMENT REQUIREMENTS CALLED FOR IN THE GEOTECHNICAL INVESTIGATION (SOILS REPORT). IF NO GEOTECHNICAL INVESTIGATION EXISTS CONTACT THE ARCHITECT FOR DEFLECTION CRITERIA. 8. ALL PARTITION TYPES MARKED BY A "t" SUFFIX (IE. D0t) SHALL BE INSTALLED WITH FULL HEIGHT AND WIDTH CONTINUOUS THERMAL INSULATION AND, IF INDICATED, CONTINUOUS VAPOR RETARDER. 9. PROVIDE GYPSUM BOARD CONTROL JOINTS PER ASTM C 840 UNLESS OTHERWISE INDICATED ON DRAWINGS. 10. PROVIDE FIRE BLOCKING AND DRAFT STOPS PER CODE. 11. AT LOCATIONS ADJACENT TO GLASS SYSTEMS, GC TO VERIFY IN FIELD AND PROVIDE FASTENERS SUCH THAT THE INSTALLATION OF METAL FRAMING DOES NOT ADVERSELY IMPACT THE GLASS SYSTEM. RATED PARTITION NOTES 1. FIRE RATED ASSEMBLY CRITERIA TAKE PRECEDENT OVER ANY OTHER CONSTRUCTION CRITERIA. 2. REFERENCE LIFE SAFETY DRAWINGS FOR LOCATIONS OF FIREWALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE PARTITIONS, SMOKE BARRIERS, AND WALLS RESISTING THE PASSAGE OF SMOKE. COMPLY WITH IBC AND ANY OTHER APPLICABLE CODES FOR CONSTRUCTION REQUIREMENTS FOR EACH RATED PARTITION TYPE. 3. REFERENCE SPECIFICATION SECTION 07 8413 – ‘PENETRATION FIRESTOP’ FOR TREATMENT OF ANY PENETRATIONS THROUGH A FIRE RATED PARTITION. 4. REFERENCE SPECIFICATION SECTION 07 8443 – ‘JOINT FIRESTOP’ FOR TREATMENT OF TOP AND BOTTOM OF WALL JOINTS AND JOINTS TO ABUTTING CONSTRUCTION. 5. PROVIDE AND SUBMIT FOR APPROVAL U.L. RATED HEAD OF WALL ASSEMBLIES FOR EACH RATED PARTITION CONDITION THAT ALLOWS FOR THE DYNAMIC MOVEMENT INDICATED. IF ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION (AHJ), OBTAIN ENGINEERING JUDGEMENTS FOR JOB SPECIFIC CONDITIONS NOT ADDRESSED BY TESTED ASSEMBLIES. 6. PROVIDE FIRE-RATED ACCESS DOORS AND FRAMES TO REACH DAMPERS OR CONTROL VALVES IN RATED PARTITIONS OR CEILING AS REQUIRED TO MAINTAIN RATING. PROVIDE NONRATED ACCESS DOORS AT NON RATED CONSTRUCTION. 7. WHERE DEVICES ARE RECESSED IN A FIRE RATED PARTITION PROVIDE: A.) DEVICE RATED FOR INSTALLATION IN RATED PARTITIONS, OR B.) CONSTRUCTION SUCH THAT FIRE RATING IS MAINTAINED BEHIND RECESSED DEVICE. 8. WHERE STRUCTURAL ITEMS SUCH AS HANGERS FOR STAIRS ARE EMBEDDED IN A RATED PARTITION CONSTRUCTION SHALL BE SUCH THAT FIRE RATING IS MAINTAINED BEHIND EMBEDDED ITEM. 9. MARKING AND IDENTIFICATION: FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE LABELED PER CODE. 10. PROVIDE SMOKE PARTITIONS TO LIMIT THE TRANSFER OF SMOKE. FILL JOINTS AND THE SPACE AROUND PENETRATING ITEMS SUCH AS DUCTS, PIPES, CONDUITS, AND SIMILAR BUILDING SERVICE EQUIPMENT WITH AN APPROVED MATERIAL TO LIMIT THE PASSAGE OF SMOKE. 11. SEE A-720.1 FOR TYPICAL FRAMING DETAILS. SOUND PARTITION NOTES 1. ALL PARTITION TYPES MARKED BY AN "s" SUFFIX (IE. D1s) SHALL BE INSTALLED AS A SOUND PARTITION INCLUDING: FULL HEIGHT AND WIDTH SOUND ATTENUATION BLANKETS (SAB), ACOUSTICAL JOINT SEALANT AT TOPS AND BOTTOMS OF ALL WALLS AND PENETRATIONS, DRYWALL TO BE FROM FLOOR TO DECK BOTH SIDES. 2. PROVIDE ELECTRICAL OUTLET BARRIER PADS IN SOUND PARTITIONS. 3. STAGGER DEVICES THAT PENETRATE OPPOSING WALL SURFACES IN ADJACENT STUD CAVITIES. RATED ASSEMBLY INFORMATION TOP OF WALL ASSEMBLY: • STANDARD INTERIOR NON-BEARING WALL ASSEMBLY: UL HW-D-0495 OR EQUAL • SHAFTWALL FLAT CONCRETE: UL HW-D-0496 • SHAFTWALL PARALLEL TO BEAM: UL HW-D-0497 • SHAFTWALL PAN DECK: UL HW-D-0504 • SHAFTWALL PROTECTED ROOF DECK: UL HW-D-0559 WALL ASSEMBLY: • STANDARD INTERIOR NON-BEARING WALL ASSEMBLY : UL U419 OR UL U423 • SHAFTWALL ASSEMBLY: UL U415 SILL TRACK OF WALL ASSEMBLY: • PROVIDE UL LISTED ASSEMBLY COMPLIANT WITH THE UL WALL ASSEMBLY AND THAT MATCHES FIRE RESISTIVITY OF THE WALL. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 3:38:49 PM 15924.00 A-720.1 DOOR SCHEDULE, PARTITION TYPES, AND DETAILS 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/4" = 1'-0" DOOR TYPES PARTITION TYPES SCHEDULE PARTITION TYPE USE DESCRIPTION PARTITION WIDTH STRUCTURE CONSTRUCTION DESCRIPTION TOP OF WALL TO FIRE RATING DESIGN NUMBER (FIRE) D0a PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE 6" ABOVE CEILING NON-RATED N/A D0b PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A D0bX SMOKE PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A D0f FURRING WALL 4 1/4" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD ONE SIDE 6" ABOVE CEILING NON-RATED N/A D0p PARTIAL HEIGHT PARTITION 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE PER ELEVATIONS NON-RATED N/A D0s PARTITION WALL, SOUND BATTS 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A D0sX SMOKE PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A D1s 1-HR PARTITION WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE 1 HR UL U419 D1sX SMOKE BARRIER WALL 4 7/8" 3-5/8" STEEL STUDS (1) LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE 1 HR UL U419 D2b 11" 3-5/8" STEEL STUDS (2) LAYERS 5/8" TYPE "X" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE 2 HR UL U419 F0s PARTITION WALL, SOUND BATTS 7 1/4" 6" STEEL STUDS (1) LAYER 5/8" GYPSUM BOARD EACH SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A J0bX 1-HR SHAFT LINER 3 1/8" 2 1/2" C-H STEEL STUDS (1) LAYERS 5/8" TYPE "X" GYPSUM BOARD ROOM SIDE WITH 1" SHAFTLINER BOARD SHAFT SIDE UNDER SIDE OF STRUCTURE 1 HR UL U415 J1b 1-HR SHAFT LINER 3 1/8" 2 1/2" C-H STEEL STUDS (1) LAYERS 5/8" TYPE "X" GYPSUM BOARD ROOM SIDE WITH 1" SHAFTLINER BOARD SHAFT SIDE UNDER SIDE OF STRUCTURE 1 HR UL U415 L0k SHAFT LINER 6 5/8" 6" C-H STEEL STUDS (1) LAYERS 5/8" TYPE "X" GYPSUM BOARD ROOM SIDE WITH 1" SHAFTLINER BOARD SHAFT SIDE UNDER SIDE OF STRUCTURE NON-RATED N/A 1/4" = 1'-0" FRAME TYPES 3" = 1'-0" A1 HM DOOR FRAME JAMB 3" = 1'-0" A2 HM DOOR FRAME HEAD DOOR SCHEDULE ROOM LEAF FRAME Hardware Set Fire Rating Wall Width Remarks REV NAME Door Type Door Material Finish Width Height Thickness Door Glass Type Frame Type Frame Material Frame Finish LEVEL 1 100 CORRIDOR F1 WD ST 3' - 6" 7' - 0" 1 3/4" - HM1 HM PT 01 20 4 7/8" 100A CORRIDOR F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 13 - 4 7/8" 101 STAFF RECESS F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 04 - 4 7/8" 102 RECEPTION FG2 WD ST 7' - 0" 7' - 0" 1 3/4" F HM1 HM PT 05 20 5" EXISTING WALL - GC TO VERIFY IN FIELD 104A CONTROL F5 WD ST 6' - 0" 7' - 0" 1 3/4" - HM1 HM PT 06 - 5" EXISTING WALL - GC TO VERIFY IN FIELD 104B HOT LAB F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 07 - 4 7/8" 104C PT TOILET F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 08 - 5" EXISTING WALL - GC TO VERIFY IN FIELD 104D PT TOILET F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 21 - 4 7/8" DOOR STOP TO BE FLOOR MOUNTED 8" FROM HINGE; 90 DEGREE SWING LIMIT 105A NUCLEAR MEDICINE CAMERA F5 WD ST 6' - 0" 7' - 0" 1 3/4" - HM1 HM PT 09 - 4 7/8" PROVIDE WALL PROTECTION ON PUSH SIDE OF DOOR; FINISH TO MATCH ADJACENT WALL PROTECTION. PROVIDE ARMOR PLATE ON PULL SIDE OF DOOR. 105B SOILED HOLD F3 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 10 - 4 7/8" PROVIDE WALL PROTECTION ON PUSH SIDE OF DOOR; FINISH TO MATCH ADJACENT WALL PROTECTION. PROVIDE ARMOR PLATE ON PULL SIDE OF DOOR. 105C ESR F1 WD ST 2' - 6" 7' - 0" 1 3/4" - HM1 HM PT 11 - 4 7/8" JANITORIAL STORAGE LOCKSET - COORDINATE KEYING WITH OWNER. PROVIDE WALL PROTECTION ON PUSH SIDE OF DOOR; FINISH TO MATCH ADJACENT WALL PROTECTION. PROVIDE ARMOR PLATE ON PULL SIDE OF DOOR. 105D NUCLEAR MEDICINE CAMERA F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 12 - 4 7/8" PROVIDE WALL PROTECTION ON PUSH SIDE OF DOOR; FINISH TO MATCH ADJACENT WALL PROTECTION. PROVIDE ARMOR PLATE ON PULL SIDE OF DOOR. 108 STORAGE F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 13 - 4 7/8" 111 OFFICE F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 14 - 4 7/8" 112 OFFICE F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 14 - 4 7/8" 114 OFFICE N1 WD ST 2' - 10" 7' - 0" 1 3/4" S HM1 HM PT 14 4 7/8" 116A OFFICE F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM1 PT 14 - 5" EXISTING WALL - GC TO VERIFY IN FIELD 116B OFFICE F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 14 - 4 7/8" 118A STORAGE F3 WD ST 4' - 0" 7' - 0" 1 3/4" - HM1 HM PT 15 - 4 7/8" 120A VEST F1 WD ST 3' - 6" 7' - 0" 1 3/4" - HM1 HM PT 17A 20 4 7/8" 120B VEST P1 WD ST 3' - 6" 7' - 0" 1 3/4" - HM1 HM PT 17B - 4 7/8" 120D PREP AREA HG1 WD ST 3' - 0" 7' - 0" 1 3/4" S HM1 HM PT 19 - 4 7/8" COORDINATE WITH HOOD DIMENSIONS 120E CHEMO MIXING ROOM HG1 WD ST 3' - 6" 7' - 0" 1 3/4" S HM1 HM PT 20 - 4 7/8" 120G CLEAN ROOM HG1 WD ST 3' - 6" 7' - 0" 1 3/4" S HM1 HM PT 20 - 4 7/8" 126 OFFICE F1 WD ST 3' - 0" 7' - 0" 1 3/4" - HM1 HM PT 14 - 4 7/8" 128A OFFICE N1 WD ST 3' - 0" 7' - 0" 1 3/4" F HM1 HM PT 17 20 4 7/8" 128B OFFICE N1 WD ST 3' - 0" 7' - 0" 1 3/4" F HM1 HM PT 17 20 4 7/8" 128C OFFICE N1 WD ST 3' - 0" 7' - 0" 1 3/4" F HM1 HM PT 17 20 4 7/8" LEVEL 2 120V TLT F1 WD ST 3' - 0" 7' - 0" 1 3/4" HM1 HM PT 08A - 4 7/8" RESCUE HARDWARE 120Y CORRIDOR F1 WD ST 3' - 0" 7' - 0" 1 3/4" HM1 HM PT 17 - 4 7/8" 121Y MEETING/WORK F1 WD ST 3' - 0" 7' - 0" 1 3/4" HM1 HM PT 17 - 4 7/8" EXISTING DOOR SCHEDULE DR. # ROOM LEAF FRAME Hardware Set Fire Rating Remarks REV NAME Door Type Door Material Finish Width Height Thickness Door Glass Type Frame Type Frame Material Frame Finish LEVEL 1 XX104 TLT - - EXISTING 3' - 0" 7' - 0" 1 3/4" - - - PT 16 - EXISTING WALL - GC TO VERIFY IN FIELD. REPLACE HARDWARE. XX105 - - 3' - 0" 7' - 0" 1 1/2" PT - XX106 XX117 - - EXISTING 3' - 0" 7' - 0" 1 3/4" - - - PT 14 - DOOR TO BE F1 TYPE. REPLACE DOOR HW SET IF EXISTING DOOR TO REMAIN; GC TO VERIFY EXISTING WALL IN FIELD. XX118B - - EXISTING 3' - 0" 7' - 0" 1 3/4" - - - PT 18 - REPLACE DOOR HARDWARE; GC TO VERIFY EXISTING WALL IN FIELD. XX119 - - EXISTING 3' - 0" 7' - 0" 1 3/4" - - - PT 14 - DOOR TO BE F1 TYPE. REPLACE DOOR HW SET IF EXISTING DOOR TO REMAIN; GC TO VERIFY EXISTING WALL IN FIELD. XX122 - - EXISTING 3' - 0" 7' - 0" 1 3/4" - HM1 - PT 14 - EXISTING WALL - GC TO VERIFY IN FIELD. REPLACE HARDWARE. LEVEL 2 XX120K - - EXISTING 3' - 0" 7' - 0" 1 1/2" - - - PT 14 - REPLACE DOOR HARDWARE; GC TO VERIFY EXISTING WALL IN FIELD. 06/30/17