HomeMy WebLinkAboutB17-0092_A-721.1_1498849080.pdfMTL. WALL STUDS
REFER
TYPICAL
MOUNTING
HEIGHTS
3 5/8" MIN,
DEEPER IF REQUIRED
18 GA. METAL RUNNER TRACK
LEG NOTCHED AROUND STUD,
EXTEND TO ONE
STUD BEYOND ATTACHMENT POINT
MAX.1/4"
7' - 0"
8' - 6" MAX. 4' - 6" MAX.
PROVIDE BLOCKING AS REQ. TO SUPPORT CABINETS,
SHELVING, EQUIPMENT, AND DECORATIVE PANELING.
PROVIDE FULL HEIGHT CONTROL JOINTS ON STRIKE
SIDE OF DOORS 3'-0" WIDE AND UNDER, PROVIDE
FULL HEIGHT CONTROL JOINTS ON BOTH SIDES OF
DOORS WIDER THAN 3'-0".
DOOR
OPENING
DOUBLE
DOOR
OPENING
NOTES:
1. CONTROL JOINTS SHALL BE INSTALLED ON BOTH SIDES
OF ALL PARTITIONS.
2. CONTROL JOINTS SHALL BE INSTALLED EVERY 20'-0"
ON BOTH SIDES OF ALL CURVED WALL PARTITIONS, AND
EVERY 30'-0" ON BOTH SIDES OF STRAIGHT PARTITIONS.
ALIGN CONTROL JOINTS WITH EDGE OF CLOSEST
ARCHITECTURAL FEATURE.
3. PROVIDE FULL HEIGHT HDS STUDS AT ALL OPENINGS
AND DOOR LOCATIONS. ALTERNATE: STUDS DESIGNATED
AS "16 GAUGE PAIR" SHALL EXTEND FULL HEIGHT FROM
FLOOR TRACK TO TRACK AT STRUCTURE ABOVE AND
SHALL BE STITCH WELDED 1/8" FLARE BEVEL STITCH
WELD - 3/4" PER 24", BOTH SIDES.
CONTRACTOR NOTE:
1. IN NO CASE SHALL DOUBLE STUDS OR HDS STUDS AT
SIDES OF OPENING BE CUT FOR DUCTWORK OR OTHER
MECHANICAL, ELECTRICAL, OR PLUMBING SYSTEMS.
CEILING LINE
BOTTOM TRACK (TYP.) 8' - 6" MAX.
1' - 6" TYP. UNO.
LARGE ABOVE CEILING
OPENING
ABOVE CEILING
OPENING
4' - 6" MAX.
LARGE BELOW CEILING
OPENING
BELOW CEILING
OPENING
8' - 6" MAX. 4' - 6" MAX.
7' - 0"
8' - 6" MAX. 4' - 6" MAX.
PROVIDE FULL HEIGHT CONTROL JOINTS ON
STRIKE SIDE OF DOORS 3'-0" WIDE AND UNDER,
PROVIDE FULL HEIGHT CONTROL JOINTS ON BOTH
SIDES OF DOORS WIDER THAN 3'-0".
DOOR
OPENING
DOUBLE
DOOR
OPENING
CEILING LINE
1' - 6" TYP. UNO.
LARGE BELOW CEILING
OPENING
BELOW CEILING
OPENING
8' - 6" MAX. 4' - 6" MAX. 6" TYP.
U.N.O.
3' - 0"
FULL HEIGHT WALL
METAL STUD WITH FULL HEIGHT GYPSUM
WALL BOARD (GWB) BOTH SIDES.
PARTIAL HEIGHT WALL
01 02
03 03
01
03
02 01 01 03
05
05 05 05
16 GA. DOUBLE STUDS
OR HDS SINGLE STUD
16 GA. DOUBLE STUDS
OR HDS SINGLE STUD
16 GA. DOUBLE STUDS
OR HDS SINGLE STUD
SLIP TRACK
SLIP TRACK
PROVIDE BLOCKING AS REQ.
TO SUPPORT CABINETS,
SHELVING, EQUIPMENT,
AND DECORATIVE PANELING.
BOTTOM TRACK (TYP.)
NOTE: ALL PARTITIONS NOT EXTENDING TO DECK TO HAVE DIAGONAL KICKER
FRAMING EVERY 48" O.C. MAX. BOTH SIDES OF PARTITION.
HIGHER PRIORITY
PARTITIONS TO
RUN CONTINUOUS
PAST A LOWER
PRIORITY
PARTITION
LOWER PRIORITY
PARTITIONS TO
TERMINATE INTO
HIGHER PRIORITY
PARTITIONS
LOWER PRIORITY PARTITIONS
TO TERMINATE INTO HIGHER
PRIORITY PARTITIONS
ALIGN
ALIGN
HIGHER PRIORITY PARTITIONS
TO RUN CONTINUOUS PAST A
LOWER PRIORITY PARTITION
NOTES:
1. REFER TO PARTITION PLANS FOR PARTITION
TYPES, NUMBER OF LAYERS OF GYP, STUD
SIZE, UL LISTING ETC.
2. THE HIGHER PRIORITY PARTITION MUST PASS
THROUGH THE LESSER PRIORITY PARTITION. THE
COMPLETE WALL ASSEMBLY MUST BE CONTINOUS
THROUGH INTERSECTION.
3. TAPE AND SEAL JOINTS IN GYP. BOARD IN
PARTITION BEHIND INTERSECTING PARTITIONS.
LOWER
PRIORITY
PARTITIONS TO
TERMINATE
INTO HIGHER
PRIORITY
PARTITIONS
HIGHER PRIORITY
PARTITIONS TO RUN
CONTINUOUS PAST
A LOWER PRIORITY
PARTITION
PLAN
PLAN
HIGHER PRIORITY PARTITIONS
TO RUN CONTINUOUS PAST A
LOWER PRIORITY PARTITION
LOWER PRIORITY PARTITIONS
TO TERMINATE INTO HIGHER
PRIORITY PARTITIONS
HIGHER PRIORITY PARTITIONS
TO RUN CONTINUOUS PAST A
LOWER PRIORITY PARTITION
LOWER PRIORITY PARTITIONS
TO TERMINATE INTO HIGHER
PRIORITY PARTITIONS
ALIGN
PLAN
PLAN
PARTITION PRIORITY LEGEND
DISCRIPTION PRIORITY RANKING
3 HOUR FIRE RATED WALLS PRIORITY 1 - HIGHEST
2 HOUR FIRE RATED SHAFTWALLS PRIORITY 2
2 HOUR FIRE RATED PARTITIONS PRIORITY 3
1 HOUR FIRE RATED SHAFTWALLS PRIORITY 4
1 HOUR FIRE RATED PARTITIONS PRIORITY 5
SMOKE PARTITIONS PRIORITY 6
SOUND PARTITIONS PRIORITY 7
NON-FIRE RATED; NON-SOUND RATED PRIORITY 8 - LOWEST
6" TYP.
STUD OR CLIP ANGLES
AS REQ'D FOR CONNECTION
SCREW AS REQ'D
SCREW AS REQ'D
MTL TRACK AT FLOOR
HDS MTL STUD
AT BOTH JAMBS ;
ANCHOR TO DECK
OR STRUCTURE ABOVE
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
MTL SILL TRACK BELOW
TRACK TO BE CUT, BENT
AND THEN SCREWED TO
STUDS
HDS STUD OR DOUBLE MTL
STUDS AT
BOTH JAMBS; JOIN
STUDS WITH 2" LONG
INTERMITTENT WELDS
BOTH SIDES; LOCATE @
TOP AND BOTTOM OF
STUDS, @ ALL DOOR
FRAME HINGE POINT
LOCATIONS AND @
REMAINING PORTION OF
STUDS NOT TO EXCEED
48" O.C.
MTL TRACK AT FLOOR
MTL. TRACK
TRACK TO BE CUT,
BENT AND THEN
SCREWED TO STUDS
MTL. TRACK
MTL. STUDS
TRACK TO BE CUT,
BENT AND THEN
SCREWED TO STUDS
MTL. TRACK
TRACK TO BE CUT, BENT
AND THEN SCREWED TO
STUDS
DOUBLE 3 5/8" OR 6"
MTL. STUDS
MTL. TRACK
TRACK TO BE CUT, BENT
AND THEN SCREWED TO
STUDS
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
01 DOUBLE DOOR / LARGE OPENING HEADER
SCALE: 3" = 1'-0" 02 DOOR OPENING HEADER
SCALE: 3" = 1'-0" 03 OPENING HEADER
SCALE: 3" = 1'-0" 04 LARGE
OPENING JAMB STUDS
SCALE: 3" = 1'-0" 05 DOOR OPENING JAMB STUDS
SCALE: 3" = 1'-0" 06 CORNER FRAMING
SCALE: 3" = 1'-0" 07 WALL INTERSECTION FRAMING
SCALE: 3" = 1'-0" 08 HEAD OF WALL DETAIL
SCALE: 3" = 1'-0"
CONTINUOUS 2" WIDE X 20 GA.
METAL STRAP. ATTACH
GYPSUM BOARD TO STRAP AT
8" O.C. MAXIMUM.
CONTINUOUS 20 GA. 2-1/2" X 2-1/2" METAL
ANGLE WITH 2-1/2" WIDE PIECE OF GYPSUM
BOARD USED FOR THE WALL - ATTACH TO
PLATE OR STEEL DECK AT 12" O.C. MAXIMUM.
NOTE:
DO NOT ATTACH GYPSUM
BOARD TO TOP TRACK.
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
ROOF OR FLOOR ASSEMBLY ABOVE
(NON-RATED)
SEALANT, TYP. BOTH SIDES
DEFLECTION TRACK TO MATCH WALL
RATING
CONT. HORIZONTAL BRIDGING AS
RECOMMENDED BY MFR. LOCATE 18" FROM
DECK UNLESS NOTED OTHERWISE.
ROOF OR FLOOR ASSEMBLY ABOVE
FLUTE DECK
CONTINUOUS FLUTE COVER
STEEL STUD
FIRE STOP
DEFLECTION TRACK
(1) LAYER OF GYP. BOARD
FOR 1-HOUR FIRE RATING-
ATTACH PER UL DESIGN.
09 HEAD OF WALL DETAIL
SCALE: 3" = 1'-0"
NOTE:
DO NOT ATTACH GYPSUM
BOARD TO TOP TRACK.
SEE PARTITION SCHEDULE
FOR WIDTH OF PARTITIONS
(RATED - SEE SPECIFICATION 07
8443 FOR MORE INFORMATION)
MINERAL WOOL FLUTE FILL
CONT. HORIZONTAL BRIDGING AS
RECOMMENDED BY MFR. LOCATE 18"
FROM DECK UNLESS NOTED
OTHERWISE.
DEFLECTION
1" ALLOWABLE
PARTITION
SEALANT
"LC" BEAD
INTERIOR PARTITION
NON-EXPOSED EDGE
CJ 1
2 3/4" GYPSUM BOARD SUSPENDED
CEILING SYSTEM
CONTROL JOINT
CONTROL JOINT FOR GYPSUM BOARD CEILING
CJ 2
24'-0"
MAX.
24'-0"
MAX.
CEILING GRID
SUSPENSION SYSTEM
CASTING BEAD
1/8" EACH SIDE
CONTINUOUS 2" WIDE
NEOPRENE FILLER
PARTITION
PARTITION ATTACHMENT TO CEILING GRID
CJ 3
PARTITION
SOLID ATTENUATION
BLANKET COMPRESSED
TO FILL OPENING AT
PARTITION
L-BEAD
SEALANT AND BACKER ROD
LINE OF PARTITION
CONTROL JOINT AT PARTITION
CJ 4
INTERSECTION / CHANGE IN CONSTRUCTION
CJ 5
DOUBLE 20 GAUGE METAL STUDS
WITH 1"X226A METAL STRAP PLATES
AT 3'-6" O.C. EACH SIDE
5/8" TYPE "X" GYPSUM BOARD
5/8" MAX.
TYPICAL CONTROL
JOINT FOR PARTITION
TYPE REQUIRING (1)
LAYER OF GYPSUM
BOARD
VINYL OR METAL CONTROL JOINT
BACKER ROD & FIRE STOP SEALANT,
CONTINUOUS AT RATED CONSTRUCTION.
1/2" GAP MAX.
5/8" TYPE "X" GYPSUM BOARD
BACKER ROD AND FIRE STOP
SEALANT CONTINUOUS AT
RATED CONSTRUCTION
1/2" GAP MAX.
METAL GYPSUM BOARD
CONTROL JOINT
DOOR CONTROL JOINT
(PROVIDE MINIMUN ONE JOINT
AT ALL DOORS AND WINDOWS)
CJ 6
TYPICAL CONTROL JOINT
FOR PARTITION TYPE
REQUIRING (1) LAYER OF
GYPSUM BOARD
VINYL OR METAL CONTROL JOINT
BACKER ROD & FIRE STOP SEALANT,
CONTINUOUS.
1/2" GAP MAX. 5/8" TYPE "X" GYPSUM BOARD
5/8" TYPE "X" GYPSUM BOARD
VINYL OR METAL CONTROL JOINT
BACKER ROD & FIRE STOP SEALANT,
CONTINUOUS.
NOTE: LOCATE CONTROL JOINTS IN
UNINTERRUPTED WALL SPANNING
MORE THAN 30"-0" & WHERE
INDICATED ON DRAWINGS, OR AT A
CHANGE IN MATERIALS, FINISH,
BACKING, OR INSIDE FACE OF BRICK
EXPANSION JOINT.
ASSEMBLY GA-WH1651-0318.1
5/8" GAP
1 HOUR PARTITION
CONTROL JOINT SECTION
CJ 7
TYPICAL CONTROL JOINT
FOR PARTITION TYPE
REQUIRING (1) LAYER OF
GYPSUM BOARD
VINYL OR METAL CONTROL JOINT
BACKER ROD & FIRE STOP SEALANT,
CONTINUOUS.
1/2" GAP MAX.
5/8" TYPE "X" GYPSUM BOARD
5/8" TYPE "X" GYPSUM BOARD
VINYL OR METAL CONTROL JOINT
BACKER ROD & FIRE STOP SEALANT,
CONTINUOUS.
NOTE: LOCATE CONTROL JOINTS IN
UNINTERRUPTED WALL SPANNING
MORE THAN 30"-0" & WHERE
INDICATED ON DRAWINGS, OR AT A
CHANGE IN MATERIALS, FINISH,
BACKING, OR INSIDE FACE OF BRICK
EXPANSION JOINT.
ASSEMBLY GA-WH1651-0318.1
5/8" GAP
1 HOUR PARTITION
CONTROL JOINT SECTION
CJ 7
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
3:38:52 PM
15924.00
A-721.1
FRAMING DETAILS
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
3" = 1'-0" D4
EQUIPMENT / ACCESSORIES MOUNTING - PHASE
1.5
1/4" = 1'-0"
TYPICAL PARTITION FRAMING ELEVATIONS
1 1/2" = 1'-0" D1
PARTITION PRIORITY - PHASE 1.5
3" = 1'-0"
C3
PARTITION FRAMING - PHASE 1.5
1 1/2" = 1'-0"
B1
CONTROL JOINTS - PHASE 1.5
06/30/17