Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0092_A-740.1_1498849080.pdf
GL-1 INTERIOR VISION GLASS - TEMPERED GL-2 INTERIOR FIRE RATED GLAZING - RE: DOOR SCHEDULE FOR RATED ASSEMBLY IN DOORS GL-3 POLYCABONATE SECURITY GLAZING GL-4 INTERIOR VISION GLASS - LEAD EQUIVALENT GLAZING GL-5 EXTERIOR INSULATED GLASS 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS PRIOR TO ORDERING OR FABRICATING ANY FRAMES. 2. ALL ELEVATIONS ARE DRAWN FACING THE EXTERIOR OF THE WINDOW FRAME. 3. STOREFRONT FABRICATOR TO PROVIDE REINFORCING AS REQUIRED FOR ANY STRUCTURAL REQUIREMENTS. 4. REFER TO PLANS FOR QUANTITIES AND LOCATIONS OF ALL DOORS AND WINDOWS. 5. ALL DIMENSIONS ARE TO MASONRY OR ROUGH OPENING UNLESS NOTED OTHERWISE, PROVIDE PROPER SHIM CLEARANCE AS REQUIRED. 6. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION. 7. REFER TO PLANS FOR WALL TYPE AND THICKNESS, COORDINATE WINDOW FLASHING WITH EXTERIOR DETAILS. FRAME GENERAL NOTES GLAZING TYPES NUCLEAR MED CONTROL ROOM WINDOW STOP 2" 1" 2" WALL PROTECTION, RE: FINISH SCHEDULE AND ELEVATIONS 08 8853 - SECURITY GLAZING 09 2216 - NON-STRUCTURAL METAL FRAMING 07 9200 - JOINT SEALANT PAINTED METAL FRAME 1/2" TYP. PARTITION AS SCHEDULED PARTITION TYPE RE: SECTION 09 2900 - GYPSUM BOARD 08 1113 - INTERIOR HOLLOW-METAL FRAME 07 9200 - JOINT SEALANT 09 2216 - NON-STRUCTURAL METAL FRAMING SECTION 08 8000 - GLAZING PARTITION TYPE RE: SECTION 09 2900 - GYPSUM BOARD 08 1113 - INTERIOR HOLLOW-METAL FRAME 07 9200 - JOINT SEALANT SECTION 08 8000 - GLAZING 2" 5/8" 5/8" 5/8" 2" 5/8" PARTITION TYPE RE: 07 9200 - JOINT SEALANT 08 1113 - INTERIOR HOLLOW-METAL FRAME SECTION 09 2900 - GYPSUM BOARD 05 4000 - COLD-FORMED METAL FRAMING SECTION 08 8000 - GLAZING 1/4" GASKET 5/8" 2" 5/8" 08 8853 - POLYCARBONATE SECURITY GLAZING 08 5113 - ALUMINUM FIXED WINDOW 09 2900 - INTERIOR GYPSUM BOARD VESTIBULE SOLID SURFACE TRANSACTION TOP, RE: FINISH SCHEDULE 4" 4" ALUMINUM U-CHANNEL WORK AREA MIN. 2" WINDOW HEADER 2" FRAME 5" 08 3323 - ROLL-DOWN SHUTTER OPENING4" UNDERLAYMENT PANEL VESTIBULE SOLID COUNTER TOP BELOW, RE: FINISH SCHEDULE WORK AREA 09 2900 - INTERIOR GYPSUM BOARD 08 5113 - ALUMINUM FIXED WINDOW 09 2216 - NON-STRUCTURAL METAL FRAMING 08 8853 - POLYCARBONATE SECURITY GLAZING 08 3323 - ROLL-DOWN SHUTTER FRAME 2" 1" 1" 2" CONTINUOUS SEALANT 08 8853 - SECURITY GLAZING 2" 1" 2" 1/2" TYP. 09 2216 - NON-STRUCTURAL METAL FRAMING WINDOW STOP NUCLEAR MED CONTROL ROOM PAINTED METAL FAME CONTINUOUS SEALANT ON BOTH SIDES PARTITION AS SCHEDULE WINDOW HEADER 08 8853 - SECURITY GLAZING WINDOW STOP 2" 2" 1" NUCLEAR MED CONTROL ROOM PAINTED METAL FAME CONTINUOUS SEALANT ON BOTH SIDES PARTITION AS SCHEDULE 1/2" TYP. 08 4113 - EXTERIOR THERMALLY BROKEN, ALUMINUM-FRAMED 08 800 - 1" INSULATED GLAZING EXISTING WALL SHIM AS NECESSARY; CONTINUOUS SEALANT AND BACKER ROD, EACH SIDE EXTERIOR INTERIOR GC TO VIF 4 1/2" 09 2116 - 6" C-H STUDS, TRUNCATE H- SECTION AT STOREFRONT MULLION BATT INSULATION 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 09 2900 - INTERIOR GYPSUM BOARD MATCH EXISTING SYSTEM 08 8113 - DECORATIVE WINDOW FILM "LLUMAR BRONZE NRMB PS2" OR SIM VAPOR RETARDER 1" X = MATCH EXISTING DIMENSION X AIR GAP EXTERIOR INTERIOR 08 4113 - EXTERIOR THERMALLY BROKEN, ALUMINUM-FRAMED 08 8000 - GLAZING X GC TO VIF 4 1/2" 09 2900 - INTERIOR GYPSUM BOARD 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 09 2116 - 6" C-H STUDS TRUNCATE H-SECTION AT STOREFRONT MULLION X = MATCH EXISTING DIMENSION MATCH EXISTING SYSTEM 08 8113 - DECORATIVE WINDOW FILM "LLUMAR BRONZE NRMB PS2" OR SIM 1" 1" BATT INSULATION VAPOR RETARDER AIR GAP LEVEL 1 100' - 0" 08 800 - 1" INSULATED GLAZING X EXTERIOR INTERIOR 08 4113 - EXTERIOR THERMALLY BROKEN, ALUMINUM-FRAMED PAN FLASHING WITH END DAMS 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 09 2116 - 6" C-H STUDS FRAMING, TRUNCATE H-SECTION AT STOREFRONT MULLION BATT INSULATION WALL BASE AS SCHEDULED X = MATCH EXISTING DIMENSION MATCH EXISTING SYSTEM 08 8113 - DECORATIVE WINDOW FILM "LLUMAR BRONZE NRMB PS2" OR SIM 1" 1" VAPOR RETARDER AIR GAP 08 800 - 1" INSULATED GLAZING 08 4113 - EXTERIOR THERMALLY BROKEN, ALUMINUM-FRAMED 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 05 4000 - C-H STUD FRAMING 09 2900 - INTERIOR GYPSUM BOARD MATCH EXISTING SYSTEM DECORATIVE WINDOW FILM; "LLUMAR BRONZE NRMB PS2" OR SIM BATT INSULATION VAPOR RETARDER AIR GAP NOTE: WHERE POSSIBLE INTEGRATE NEW GLASS INTO EXISTING STOREFRONT SYSTEM INSTEAD OF TWO MULLIONS. T.O. COUNTER 2' - 10" 4" 2' - 4" 2" / D2A-740.1 /C2 A-740.1 2" 1' - 8" 2" 2' - 0" 1' - 8" W2 08 8853 - GLASS TYPE GL-3 SHATTER PROOF PLEXI-GLASS 08 0811 - PASS THROUGH WINDOW WITH ROLL-DOWN SHUTTER PASS-THROUGH OPENING LEVEL 1 100' - 0" V.I.F. 8' - 8" X V.I.F. 2' - 5 1/4" X V.I.F. 5' - 7 1/4" X V.I.F. 3 EQ SPACES = 13' - 2" X EQ X EQ X EQ X / C5A-740.1 / E5A-740.1 / B5A-740.1 /B4 A-740.1 /B4 A-740.1 W3 0880 - GLASS TYPE GL-5- EXTERIOR INSULATED GLASS 08 4113 - ALUMINUM - FRAMED STOREFRONT SYSTEM ALIGN MULLION TO EXISTING X = MATCH EXISTING DIMENSION 3' - 3" 2" 3' - 7" 2" 3' - 11" 2" 3' - 9" 2" 4' - 1" W1 08 0880 - GLASS TYPE GL-1 - INTERIOR VISION GLASS - TEMPERED 08 0811 - HM WINDOW SYSTEM / E4A-740.1 /C4 A-740.1 / D4A-740.1 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 3:38:58 PM 15924.00 A-740.1 WINDOW TYPES AND DETAILS 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 3" = 1'-0" C4 WINDOW JAMB DETAIL 3" = 1'-0" D1 TYPICAL WINDOW SECTION DETAIL 3" = 1'-0" C1 TYPICAL WINDOW JAMB DETAIL 3" = 1'-0" D2 TRANSACTION WINDOW DETAIL 3" = 1'-0" C2 TRANSACTION WINDOW JAMB DETAIL 3" = 1'-0" D4 WINDOW SILL DETAIL 3" = 1'-0" E4 WINDOW HEAD DETAIL 3" = 1'-0" E5 EXTERIOR STOREFRONT HEAD DETAIL 3" = 1'-0" C5 EXTERIOR STOREFRONT MULLION DETAIL 3" = 1'-0"B5 EXTERIOR STOREFRONT SILL DETAIL 3" = 1'-0" B4 EXTERIOR STOREFRONT JAMB DETAIL 06/30/17