B17-0092_A-740.1_1508947552.pdf
GL-1 INTERIOR VISION GLASS - TEMPERED GL-2 INTERIOR FIRE RATED GLAZING - RE: DOOR SCHEDULE FOR RATED ASSEMBLY IN DOORS GL-3 POLYCARBONATE SECURITY GLAZING GL-4 INTERIOR VISION GLASS - LEAD EQUIVALENT GLAZING GL-5 EXTERIOR INSULATED GLASS 1. CONTRACTOR TO FIELD COORDINATE ALL ROUGH OPENINGS PRIOR TO ORDERING OR FABRICATING ANY FRAMES. 2. ALL ELEVATIONS ARE DRAWN FACING THE EXTERIOR OF THE WINDOW FRAME. 3. STOREFRONT FABRICATOR TO PROVIDE REINFORCING AS REQUIRED FOR ANY STRUCTURAL REQUIREMENTS. 4. REFER TO PLANS FOR QUANTITIES AND LOCATIONS OF ALL DOORS AND WINDOWS. 5. ALL DIMENSIONS ARE TO MASONRY OR ROUGH OPENING UNLESS NOTED OTHERWISE, PROVIDE PROPER SHIM CLEARANCE AS REQUIRED. 6. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION. 7. REFER TO PLANS FOR WALL TYPE AND THICKNESS, COORDINATE WINDOW FLASHING WITH EXTERIOR DETAILS. FRAME GENERAL NOTES GLAZING TYPES NUCLEAR MED CONTROL ROOM WINDOW STOP 2" 1" 2" WALL PROTECTION, RE: FINISH SCHEDULE AND ELEVATIONS 08 8853 - SECURITY GLAZING 09 2216 - NON-STRUCTURAL METAL FRAMING 07 9200 - JOINT SEALANT PAINTED METAL 1/2" TYP.PARTITION AS PARTITION TYPE RE: SECTION 09 2900 - GYPSUM BOARD 08 1113 - INTERIOR HOLLOW-METAL FRAME 07 9200 - JOINT SEALANT 09 2216 - NON-STRUCTURAL METAL FRAMING SECTION 08 8000 - GLAZING PARTITION TYPE RE: SECTION 09 2900 - GYPSUM BOARD 08 1113 - INTERIOR HOLLOW-METAL FRAME 07 9200 - JOINT SEALANT SECTION 08 8000 - GLAZING 2" 5/8"5/8" 5/8"2"5/8" PARTITION TYPERE:07 9200 - JOINT SEALANT 08 1113 - INTERIOR HOLLOW-METAL FRAME SECTION 09 2900 - GYPSUM BOARD 05 4000 - COLD-FORMED METAL FRAMING SECTION 08 8000 - GLAZING 1/4"GASKE 5/8"2" 5/8" 08 8853 - POLYCARBONATE SECURITY GLAZING 08 5113 - ALUMINUM FIXED WINDOW 09 2900 - INTERIOR GYPSUM BOARD VESTIBULE SOLID SURFACE TRANSACTION TOP, RE: FINISH SCHEDULE 4" 4" ALUMINUM U- WORK AREA MIN.2"WINDOW HEADER 2" FRAME 5" 08 3323 - ROLL-DOWN SHUTTER OPENING4"UNDERLAYMENT PANEL VESTIBULE SOLID COUNTER TOP BELOW, RE: FINISH SCHEDULEWORK AREA 09 2900 - INTERIOR GYPSUM BOARD 08 5113 - ALUMINUM FIXED WINDOW 09 2216 - NON-STRUCTURAL METAL FRAMING 08 8853 - POLYCARBONATE SECURITY GLAZING 08 3323 - ROLL-DOWN SHUTTER FRAME 2" 1"1" 2" CONTINUOUS SEALANT 08 8853 - SECURITY GLAZING 2"1"2"1/2" TYP. 09 2216 - NON-STRUCTURAL METAL FRAMING WINDOW NUCLEAR MED CONTROL ROOM PAINTED METAL FAME CONTINUOUS SEALANT ON BOTH SIDES PARTITION AS SCHEDULE WINDOW HEADER 08 8853 - SECURITY GLAZING WINDOW2"2"1" NUCLEAR MED CONTROL ROOM PAINTED METAL FAME CONTINUOUS SEALANT ON BOTH SIDES PARTITION AS 1/2" TYP. EXISTING WALL EXTERIOR INTERIOR GC TO VIF 4 1/2" 09 2116 - 6" C-H STUDS, TRUNCATE H- SECTION AT STOREFRONT MULLION 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 09 2900 - INTERIOR GYPSUM BOARD VAPOR RETARDER 1"AIR GAP EXISTING STOREFRONT 07 2119 - CLOSED-CELL SPRAY POLYURETHANE FOAM R-21 INTERIOR GC TO VIF 4 1/2" 09 2900 - INTERIOR GYPSUM BOARD 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 09 2116 - 6" C-H STUDS TRUNCATE H- SECTION 08 8113 - DECORATIVE WINDOW FILM "LLUMAR BRONZE NRMB PS2" OR SIM1"1" VAPOR BARRIER AIR GAP EXISTING STOREFRONT 07 2119 - CLOSED-CELL SPRAY POLYURETHANE FOAM R-21 LEVEL 1 100' - 0" EXTERIOR INTERIOR PAN FLASHING WITH END DAMS 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 09 2116 - 6" C-H STUDS FRAMING, TRUNCATE WALL BASE AS SCHEDULED 08 8113 - DECORATIVE WINDOW FILM "LLUMAR BRONZE NRMB PS2" OR SIM 1"1"VAPOR BARRIER AIR GAP EXISTING STOREFRONT 1 07 2119 - CLOSED-CELL SPRAY POLYURETHANE FOAM R-21 1 09 2116.23 - GYPSUM SHAFTLINER BOARD, MOISTURE- AND MOLD-RESISTANT TYPE X 05 4000 - C-H STUD FRAMING 09 2900 - INTERIOR GYPSUM BOARD DECORATIVE WINDOW FILM; "LLUMAR BRONZE NRMB PS2" OR SIM BATT INSULATION VAPOR RETARDER AIR GAP NOTE: WHERE POSSIBLE INTEGRATE NEW GLASS INTO EXISTING STOREFRONT SYSTEM INSTEAD OF TWO MULLIONS. EXISTING STOREFRONT 1 T.O. COUNTER2' - 10" 4" 2' - 4" 2"/ D2 A-740.1 /C2 A-740.1 2" 1' - 8" 2" 2' - 0" 1' - 8" W2 08 8853 - GLASS TYPE GL-3 SHATTER PROOF PLEXI-GLASS 08 0811 - PASS THROUGH WINDOW WITH ROLL-DOWN SHUTTER PASS-THROUGH OPENING / D2 A-740.1 3' - 3" 2" 3' - 7"2"3' - 11"2" 3' - 9" 2" 4' - 1" W1 08 0880 - GLASS TYPE GL-1 - INTERIOR VISION GLASS - TEMPERED 08 0811 - HM WINDOW SYSTEM / E4 A-740.1 /C4A-740.1 / D4 A-740.1 /C4 A-740.1 BASIS OF DESIGN: UL ASSEMBLY NO: WW-S-1039 "MULL-IT- OVER" 60 MINUTE FIRE RATED ASSEMBLY. EXISTING SILL BEYOND SNAP COVER TO CONCEAL FASTENERS; FINISH TO MATCH MULLION SYSTEM. 07 9200 JOINT SEALANT DASH LINE INDICATES 08 8113 - DECORATIVE WINDOW FILM; "LLUMAR BRONZE NRMB PS2" OR SIM. ON INTERIOR SIDE OF GLASS PARTITION AS SCHEDULED MULLION BEYOND 07 9200 JOINT SEALANT FASTENER EXTRUDED ALUMINUM WITH FINISH TO MATCH MULLION SYSTEM SOUND DEADENING COMPOSITE INTUMESCENT LAYER COMPRESSIBLE GASKET, TYPICAL BOTH SIDES OF ASSEMBLY CORNER BEAD 3 1/4" THICK ALUM PLATE FINISHED TO MATCH EXISTING STOREFRONT SYSTEM. EDGE OF EXISTING MULLION AND STOREFRONT SYSTEM ADHESIVE AT REGULAR INTERVALS; VISUALLY CONCEAL 1/4" THICK ALUM PLATE FINISHED TO MATCH EXISTING STOREFRONT SYSTEM. DASHED LINE INDICATE WINDOW TREATMENT BRACKET LOCATION EDGE OF WINDOW JAMB BEYOND SELF TAPPING FASTENERS DASHED LINE INDICATE WINDOW TREATMENT INTERMEDIATE BRACKET; USE SELF TAPPING FASTENERS; LOCATE AND SIZE SUCH THAT FASTENERS DO NOT IMPACT EXISTING STOREFRONT SYSTEM ELEVATION A-A ELEVATION A-ANOTE: INTENT IS TO INSTALL WINDOW TREATMENT USING BRACKET IN LIEU OF DAMAGING THE EXISTING STOREFRONT SYSTEM. BASIS OF DESIGN: "MULL-IT-OVER" STC 55 ASSEMBLY. EXISTING SILL BEYOND SNAP COVER TO CONCEAL FASTENERS; FINISH TO MATCH MULLION SYSTEM. 07 9200 JOINT SEALANT DARK LINE INDICATES 08 8113 - DECORATIVE WINDOW FILM; "LLUMAR BRONZE NRMB PS2" OR SIM. ON INTERIOR SIDE OF GLASS PARTITION AS SCHEDULED MULLION BEYOND 07 9200 JOINT SEALANT FASTENER EXTRUDED ALUMINUM WITH FINISH TO MATCH MULLION SYSTEM SOUND DEADENING COMPOSITE COMPRESSIBLE GASKET, TYPICAL BOTH SIDES OF ASSEMBLY 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:26:32 AM15924.00 A-740.1 WINDOW TYPES AND DETAILS 2017 07/11/17PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 3" = 1'-0" C4 WINDOW JAMB DETAIL 3" = 1'-0"D1 TYPICAL WINDOW SECTION DETAIL 3" = 1'-0" C1 TYPICAL WINDOW JAMB DETAIL 3" = 1'-0" D2 TRANSACTION WINDOW DETAIL 3" = 1'-0" C2 TRANSACTION WINDOW JAMB DETAIL 3" = 1'-0"D4 WINDOW SILL DETAIL 3" = 1'-0"E4 WINDOW HEAD DETAIL 3" = 1'-0"E5 EXTERIOR STOREFRONT HEAD DETAIL 3" = 1'-0"C5 EXTERIOR STOREFRONT MULLION DETAIL 3" = 1'-0"B5 EXTERIOR STOREFRONT SILL DETAIL 3" = 1'-0"B4 EXTERIOR STOREFRONT JAMB DETAIL 1 1 1 1 3" = 1'-0"B2 EXTERIOR AL DOOR PLAN DETAIL 2 3" = 1'-0"A2 WINDOW TREATMENT BRACKET AT EXISTING STOREFRONT 3 3" = 1'-0" B1 EXTERIOR MULLION AT PARTITION 3 ADDENDUM 1 05/23/17 1 ADDENDUM 2 06/12/17 2 ADDENDUM 3 06/27/17 3 10/25/17