Loading...
HomeMy WebLinkAboutB17-0092_AD152C.1_1498849080.pdfH Ce78 Be78 3e78 4e78 5e78 6e78 7e78 9e78 12e78 13e78 18e78 21e78 De78 De79 RE: FLOOR PLAN 3' - 0" 7' - 9" 7' - 9" 7' - 9" 7' - 9" 7' - 9" 7' - 9" 7' - 10" 7' - 9" 7' - 9" 7' - 10" C02 C02 C02 C02 C02 C02 C02 C02 C02 C02 C02 (E) X-RAY (E) OFFICE (E) OFFICE (E) EXAM (E) EXAM (E) EXAM (E) EXAM (E) BREAK (E) EXAM (E) RECEPTION (E) CLOSET C02 C02 EXISTING SYSTEMS, LIFE SAFETY FEATURES, ETC., ARE TO REMAIN OPERATIONAL DURING THE HOURS OF XX AND XX AND ALL SHUT DOWNS OR MODIFICATIONS WILL BE AT NIGHT OR ON WEEKENDS. ADDITIONALLY, NO SYSTEM IS TO BE SHUT DOWN WITHOUT FIRST COORDINATING WITH VVMC AND OBTAINING AN APPROVED METHOD OF PROCEDURE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. PATCH AND REFINISH AREAS INPACTED BY CONSTRUCTION. FINAL CONDITION TO BE LIKE-NEW. PROVIDE CORNER OR WALL GUARDS AT ALL EXPOSED CORNERS IN PATIENT AREAS ALL LIFE SAFETY SYSTEMS AND FIRE RATED ASSEMBLIES TO BE MAINTAINED PER LIFE SAEFTY CODE REQUIREMENTS AT ALL TIMES. SEE LS SERIES FOR MORE INFORMATION. DOORS TO BE LOCATED 6" FROM ADJACENT WALL ON HINGE SIDE UNLESS NOTED OTHERWISE SALVAGE ALL MEDICAL EQUIPMENT, CONFIRM NEW LOCATION WITH OWNER PROVIDE COORDINATION WALK WITH OWNER AND ARCHITECT TO CONFIRM ALL BACK BOXES AND WALL DEVICE LOCATION BEFORE DRYWALL INSTALLATION. WHEN ITEM NOTED TO BE DEMOLISHED, ENTIRETY OF ITEM TO BE DEMOLISHED. ABANDON IN PLACE IS NOT ACCEPTABLE. CONTRACTOR IS ULTIMATELY RESPONSIBILE FOR ALL DEMOLITION AND PREPARTIONS REQUIRED FOR FINAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO CORING, TRENCHING, AND FINISH MODIFICATIONS PROVIDE METAL TRIM AT ALL EXPOSED CORNERS AT TILE LOCATIONS. WALL MOUNTED DEVICES SHALL NOT SPAN BETWEEN SURFACES OF VARYING DEPTH. DEVICES TO BE LOCATED SUCH THAT THEY DO NOT SPAN BETWEEN SURFACES OF VARYING DEPTH OR SCRIBED INTO THE SURFACE MATERIAL WITH THE GREATEST DEPTH OF THE WALL. EXISTING FLOORING AND WALL FINISH TO BE REPLACED WHERE FUNCTION OF SPACE IS CHANGING OR NEW FLOOR FINISH IS SCHEDULED, TYP. GENERAL NOTES GENERAL NOTES AREA NOT IN SCOPE 8' x 0" CEILING HEIGHT ABOVE FINISH FLOOR GYP. BOARD CEILING 2' x 2' ACT CEILING EPOXY FINISH ON GYP. BOARD CEILING RCP TO BE DEMOLISHED KEY PLAN KEYNOTE LEGEND 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 3:40:11 PM 15924.00 AD152C.1 ENLARGED DEMOLITION RELFECTED CEILING PLAN - AREA C 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 1/4" = 1'-0" A1 ENLARGED DEMOLITION REFLECTED CEILING PLAN - AREA C A B C NORTH C02 EXISTING CEILING TO REMAIN. WHERE EXISTING TILE IS DAMAGED OR STAINED, REPLACE WITH NEW TILE MATCHING EXISTING SYSTEM 06/30/17