Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0092_CUTBOOK_1491500107.pdf
Mitchell Associates 630 Dundee Rd. - Suite 340 Northbrook, IL 60062 Telephone 847.412.0300 Facsimile 847.412.0385 www.mitchellplanning.com INSTRUCTIONS FOR PRINTING HARD COPY When printing a Hard Copy make sure to print both the document and comments FILE > PRINT (CTRL+P) > PRINT WHAT: Document and Comments (Located above PRINTING TIPS) Vail Valley Medical Center Medical Equipment Cutbook Central Department Phase 02/28/2017 E-NUMBER GENERIC DESCRIPTION REVISED 12/27/2016 REVISED 2/28/2017 BRK01 BRACKET CAL01 CALIBRATOR, RADIOISOTOPE CBL01 CABINET, LEAD LINED CHANGED CBL02 CABINET, LEAD LINED DELETED CBR01 COFFEE BREWER CBS01 CABINET, SAFETY, BIOLOGICAL CHANGED CLF01 CABINET, LAMINAR FLOW ADDED CRT04 CART, UTILITY ADDED DIS01 DISINFECTOR DSS01 DISPOSAL CONTAINER, SHARPS W/BRACKET DSS03 DISPOSAL CONTAINER, WASTE, PHARMACEUTICAL DSS04 DISPOSAL CONTAINER, WASTE, PHARMACEUTICAL FZU01 FREEZER, UNDERCOUNTER ICG01 IMAGING, CAMERA, GAMMA ADDED IUS02 IMAGING, ULTRASOUND SCANNER LET01 LIGHT, EXAM/TREATMENT ADDED MTR01 MONITOR, ECG OVN01 OVEN, MICROWAVE OVN03 OVEN, MICROWAVE RCK03 RACK, ULTRASOUND PROBES REF02 REFRIGERATOR, UPRIGHT, PHARMACY REF03 REFRIGERATOR, UPRIGHT, PHARMACY REF05 REFRIGERATOR/FREEZER, UPRIGHT RFU05 REFRIGERATOR, UNDERCOUNTER CHANGED CHANGED RFU06 REFRIGERATOR/FREEZER, UNDERCOUNTER ADDED SAF01 SAFE, NARCOTICS CHANGED SHW02 SHELVING, WIRE SHW03 SHELVING, WIRE DELETED ADDED STR04 STRETCHER, PROCEDURE TBL01 TABLE, EXAM, ADULT ADDED WRM02 WARMER, CONTRAST MEDIA ADDED ***FOR DESIGN PURPOSES ONLY NOT FOR CONSTRUCTION*** 1 1 EQUIP# BRK01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. DOSE CALIBRATORS8 www.capintec.com • Hard copy records of data available from optional dot matrix printer • Vial and syringe labels on adhesive-backed strips available from optional mini- printer • 6-channel pulse height analyzer with spectral pulse amplitude discrimination for preliminary isotope identification • Compatible with nuclear medicine information management systems via USB or Rs-232 ports • Calculation of printable dose table • Inventory control- maintains inventory of unit dose and kits • Automated linearity and geometry testing • Radiochromatography QC package • CRC®-25W Dose Calibrator/Well Counter The new standard in providing dose calibration, wipe tests and lab tests all in one unit! As a combination of the popular CRC®-25R Dose Calibrator and the CAPRAC®-R Well Counter, the CRC®-25W dose calibrator provides advanced features with the speed and accuracy you need to measure activity and prepare doses. Its ion chamber is one of Capintec’s time-tested, high pressure well designs capable of measuring a dose as high as 6 Ci (250 GBq) of Tc 99m with high accuracy. The CRC®-25W now features a helpful chamber plug- and-play capability. For wipe testing, the CRC®-25W allows the user to define specific counting procedures (protocols) with trigger levels for work, patient, unrestricted areas and sealed source leak tests. The CRC®- 25W also performs counting functions for wipe tests in as little as 6 seconds at activities as low as 1 nCi. Low activities are measured with a drilled well high sensitivity Sodium Iodide (NaI) detector. The 6-channel pulse-height analyzer also provides the user with pulse amplitude discrimination, which can be used to help with radionuclide isotope identification. The chamber and counter of the CRC®-25W are combined in a menu driven, push-button interface that is easy to learn and use. Perform nuclide and Daily Test selections hundreds of feet away from the CRC®-25W read out unit with our new remote capabilities. Count on Capintec not only for excellence in energy measurement, but for our unsurpassed customer service, training and support! continued on next page 25W Features • USB and RS232 ports • Software upgrade via SD flash card • USB printer capability • Chamber plug-and-play capability • Intelligent, interactive remote • Both remote and chamber can be placed 100 feet from the readout unit • Selection of Nuclide and Daily Test can be done with the remote • Built-in dose calibration, quality control and self diagnostics • Well counter for wipe tests and laboratory tests • User-definable protocols for wipe testing • Large character, high visibility display with automatic backlighting • Over 80 nuclides in memory • Automatic energy calibration, zeroing and background subtraction 25W Specifications • Well Detector: Sodium Iodide (NaI) drilled-well crystal detector; Energy Discrimination: Fixed range MCA, channel windows are 15-100, 100-200, 200-400, 400-660, 660-800 and >800 keV; Warning Trigger Levels: User- definable; Tests: Daily test by standard sources (Cs-137 or Ba-133), data and program memory configuration EQUIP# CAL01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. CRC® PC Communications software will allow for faster and easier data acquisition and storage to your computer. Measurement data, including isotope name and activity, will be transmitted and stored on your PC via an RS232 interface port and the Dose-Link Software package. Ideal for maintaining regulatory compliance, research studies or use in production facilities. The PC Communications software will create an interface between your CRC®-25R or 25W dose calibrator and your PC. The Dose Link program has four modes of operation: • Acquire and Store Data - Each second the name and activity of the isotope selected on the dose calibrator console will be updated by the program. This data can be saved and exported to an Excel spreadsheet. • Repetitive Acquisitions - Following user defined parameters of time intervals and number of measurements, activity and isotope data are acquired and saved. The data can then be printed or exported. Great for performing quarterly linearity tests (you don't even have to be there). • Maximum Activity Acquisition - The activity and isotope are updated and displayed at time intervals defined by the user, when data acquisition is stopped, the maximum activity and time will be saved and can be printed or exported. The CRC® PC Communications software is easy to install, easy to use and almost as cost conscious as you are. Help your department maintain accurate record keeping without breaking the department budget. CRC®-25R and 25W PC Series Communications Software Fast and Easy Data Acquisition- Track, Record and Store Dose Calibrator Measurements on Your PC Data Acquisition Screen (201) 825-9500 / (800) 631-3826 DOSE CALIBRATORS 9 25R/W PC Communications Software..........................................0960-0173 • Ionization Chamber: Thin wall, deep well, high pressure; Measurement: Auto ranging; Activity Range: Up to 6 Ci (250 GBq); Resolution: .001 mBq (.01 μCi); Response Time: Within 2 sec., for low activity sample, 4 to 16 sec. (user selectable); Tests: Daily tests include Auto Zero, Background Adjustment, Voltage Test, Data Check, Accuracy and Constancy • Display Screen: Dot matrix liquid crystal display; Bq/Ci Reading: User selectable or fixed; Calibrator Values: Selected radionuclide,calibration number, measured activity and display units (Bq/Ci); Counter Values: Wipe and lab test results • Electrometer: Accuracy: Better than ± 2%; Linearity: Within ± 2% • Nuclide Data: Setting Keys: 8 pre-set, 5 user selectable; Calibration # Key: Calibration # Keys for Over 200 nuclides; System Memory: Over 80 nuclides (w/cal number and half-life) • Standard Source Data: System Memory: Co-57, Co-60, Ba-133, Cs-137, Ra- 226 standard sources • Molybdenum-99 Assay: Methods: CAPMAC® & canisters; Measured Values: Mo-99 elution, Tc-99m,Tc-99m/Mo-99 ratio • PC Port: Interface: RS-232C and USB port; Compatibility: Standard nuclear medicine management systems • Printer Port: RS-232 & USB • Power Requirements: 100-240 VAC (50/60 Hz) 100 MA • Tests: Diagnostics: Full test of program, system memories • Cable: Printer (Optional): 1.8m (6ft) CRC®-25W Calibrator .................................................................. 5130-3216 Optional Accessories CRC®-25 Interactive Remote Display............................................5130-2224 Epson Roll Printer..........................................................................5430-0058 Epson Ticket Printer ......................................................................5430-0100 CRP-200 Dose Tickets & Labels....................................................7120-1199 Environmental Shield ....................................................................7300-2450 Well Detector Auxilary Shield........................................................5420-2072 Moly Assay Liner ............................................................................7300-2004 Moly Assay Dipper..........................................................................7300-2005 EQUIP# CAL01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# CRB01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. The quietest, most energy-efficient, total exhaust biological safety cabinet with the industry’s simplest and safest filter exchange system. Meets NSFStandards UnderwriterLaboratories Listed UniPressure™ Preflow Plenum Class II, Type B2 Biosafety Cabinet(Meets UL 1805 Classification, Fume Hoods) EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. BioChemGARD e3 BCG401 BioChemGARD e3 BCG601 Introducing The Baker Company BioChemGARD e3 Biological Safety Cabinet Make the World a Better Place • Industry’s most durable and reliable cabinet means lower life- cycle costs and years of trouble-free operation • Most energy-efficient operation available. A 70% reduction in electrical power compared to traditional B2 cabinets • Increased motor blower reserve (at least 420%) extends filter life for less downtime • Continuously safe work environment with self-adjusting motor technology enhances productivity • ExchangeSAFE™ Sealed Access Filter Exchange System minimizes exposure to contaminants and allows faster, simpler maintenance • Quieter operation and ergonomic design with slanted viewscreen, cool-white lights for easier viewing and reduced heat generation • Optional fume hood package for versatile laboratory design EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. The BioChemGARD e3 from the Baker Company offers superior performance, versatility, energy savings, and simpler maintenance Based on six decades of research and innovation, the BioChemGARD e3 is the most advanced biological safety cabinet engineered specifically for laboratories that need containment and removal of vapors, mists, and particulates. With the optimum balance of performance and energy efficiency, the BioChemGARD e3 protects personnel, product, and the environment, all while increasing lab productivity and user comfort. Each cabinet is precisely engineered to deliver a lower life cycle cost, the latest ergonomic design, and a revolutionary airflow management system. PAGE 1 Exclusive Filter Exchange System Decreases Downtime and Increases Safety Our new ExchangeSAFE™ Sealed Access Filter Exchange System* permits filter bagging and exchanges within the work surface, providing improved access, a simpler process, and an overall reduction in maintenance time while still minimizing exposure to contaminants by running the exhaust during the filter change. *patent-pending Innovative Fume Hood Option Offers Greater Versatility in the Lab With our optional Fume Hood Package, the BioChemGARD e3 meets the UL requirements for Electrical/Mechanical Safety (UL 61010-1) and the UL require ments for Material Flammability and Effectiveness of Airflow Characteristics (UL 1805). The cabinet has been tested in accordance with ANSI/ASHRAE 110-1995. Usage should be determined by a professional industrial hygienist or safety officer. EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Precision engineering and our exclusive technologies work in concert to achieve an optimum balance of energy efficiency with high performance. The BioChemGARD e3 is the only total exhaust biosafety cabinet that offers your lab this level of high performance, user convenience and comfort, with such significant operational savings. Our exclusive technologies—StediFlow, ReadySAFE, UniPressure Preflow Plenum, and innovative motor/blower system— work seamlessly together to deliver unparalleled safety performance, less cabinet downtime for cleaning and maintenance, and increased productivity, all while reducing your equipment operating and conditioned air removal costs. StediFLOW™ VFD Motor Controller Automatically Achieves Optimum Performance Baker’s new StediFLOW VFD (variable frequency drive) motor controller uses less energy, reduces heat output, and operates more quietly. VFD is state-of-the art technology in HVAC systems for performance and energy savings. The BioChemGARD e3 cabinet can automatically handle an increase in pressure drop of more than 420% across the filter without reducing total air delivery more than 10%. There is no need for manual speed control. • Maintains precise airflow and motor draws only 0.6 Amps—a 90% reduction in the draw of traditional B2 cabinets. • Automatically compensates for normal power line variations, air disruptions, and filter loading. • Constant air volume reduces risk of performance degradation, which can compromise personnel and product protection. • Controls the ReadySAFE operating mode. PAGE 2 50 100 150 200 250 Traditional Motor Controller Filter Life Baker StediVOLT Filter Life Baker StediFLOW Filter Life Filter Pressure Drop Increase (%) 420 StediFLOW extends filter life Reduce your annual operating costs by 49%! The BioChemGARD e3 is engineered to operate with a reduced-exhaust airflow and resistance. This minimizes noise, cuts the electrical power and static pressure requirements, while significantly reducing the volume of conditioned air exhausted from the laboratory. Operating at only 664 CFM, the BioChemGARD e3 offers a 23% reduction in exhausted conditioned air compared to tradi- tional B2 cabinets. Together, Baker’s exclusive technologies deliver an average reduction of 49% in a lab’s annual operating costs. $2,000 $1,500 $1,000 $500 0 Baker BCG (B2), Normal Baker BCG (B2), Normal & ReadySAFE Market Avg (B2) $2,500 1 Market average for NSF listed B2 Cabinets 2 Assumes an average daily US industrial electrical operating cost of $.0673 per kWh 3 Assumes $4.00/CFM/Year, lowest customer sampled $4,000 $3,500 $3,000 $2,814 $1,777 $3,498 TOT A L O P E R A T I N G C O S T S Savings of 49% Savings of 20% Annual Costs Equipment operating costs Conditioned air removal costs EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ReadySAFE™ mode – A Versatile Low Flow Mode to Make Your Job Easier This versatile mode can be used during meetings, work breaks, and overnights to maintain safe conditions, create a quieter work environment, and significantly reduce energy usage, compared to leaving the cabinet in operating mode 24 hours per day. • The BioChemGARD e3 meets and exceeds NSF/ANSI Standard 49 Class II and ISO class 4 criteria in ReadySAFE mode. When the viewscreen is closed, which results in a 50% reduction in the electricity draw and a 55% reduction in exhaust airflow. • Reduces laboratory air-conditioning requirements with less heat generation. • Increases productivity by allowing user to have instantly safe working conditions upon opening the viewscreen and ongoing work can be left in the cabinet without fear of contamination. • Reduces cabinet noise levels in laboratory environment—measured at 43 decibels (excluding exhaust system). Innovative UniPressure™ Preflow Plenum The BioChemGARD e3 biological safety cabinet incorporates Baker’s exclusive UniPressure Preflow Plenum high-perfor mance airflow system that saves energy and extends filter. • Apportions and distributes air across, then through, the HEPA supply filter, improving downflow uniformity, reducing noise, and increasing reserve blower/motor capacity. • Filter mount provides direct seal of HEPA filters to plenum, and simplifies filter replacement. Motor/Blower System Extends Filter Life Baker’s optimum blower/motor design ensures performance and extends filter life at least additional 50% over our previous cabinets—the longest life in the industry—with a range of over 10 years. (High levels of background particulates may shorten HEPA filter life.) • Provides consistent volume of air despite increases in resistance due to filter loading, resulting in extremely long filter life. • Extended filter life minimizes filter replacement and decontamination costs, reduces use of toxic fumigants, and produces less waste in the environment. • Requires no manual adjustment over filter’s life. All filter reserve is automatic. LABORATORYPRODUCTS PAGE 3 The Baker exclusive UniPressure Preflow Plenum provides quieter, more efficient operation. ReadySAFE mode – Unique bypass armrest allows cabinet to continue operation with closed viewscreen EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Craftmanship and Innovative, Versatile Design Ensures Quality Performance Baker cabinet designs represent many years of experience in stainless steel fabrication and craftsmanship. The BioChemGARD e3, like all Baker cabinets, includes design features to improve safety, productivity, user-comfort, and performance throughout a range of repetitive tasks performed on a daily basis. Exclusive ExchangeSAFE™ Sealed Access Filter Exchange System Decreases Downtime and Increases Safety Many traditional bag-in/bag-out (BIBO) filter systems, which are typically located overhead the cabinet’s work surface, have complex and time-consuming procedures that can result in a higher risk of exposure to contaminants. Our new ExchangeSAFE™ Sealed Access Filter Exchange System* permits filter bagging and exchanges within the work surface, providing improved access, a simpler process, and an overall reduction in maintenance time while still minimizing exposure to contaminants by running the exhaust during the filter change. *patent-pending Innovative Fume Hood Option Offers Greater Versatility in the Lab With our optional Fume Hood Package, the BioChemGARD e3 meets the UL requirements for Electrical/Mechanical Safety (UL 61010-1) and the UL requirements for Material Flammability and Effectiveness of Airflow Characteristics (UL 1805). The cabinet has been tested in accordance with ANSI/ASHRAE 110-1995. Usage should be determined by a professional industrial hygienist or safety officer. Negative-Pressure Double-Wall Plenums with Cable Ports Enhance Safety Baker’s unique all metal, double-wall design of the BioChemGARD e3 cabinet creates base, side, and back wall plenums that capture and contain contaminated air under negative pressure. This prevents contaminated air from escaping into the laboratory environment in the event of damage to the cabinet walls. Our optional cable ports are an industry exclusive* and can be located in both the left and right side walls of the cabinet. They provide a safe and ergonomic way of introducing cables or siphoning tubes into the work area without interfering with the viewscreen opening. *patent pending and NSF-approved PAGE 4 Cable ports allow cables/tubing to exit side walls rather than the front work area. EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. LABORATORYPRODUCTS PAGE 5 Momentum Air Curtain and High-Velocity Return Air Slots Increase Protection The BioChemGARD e3 cabinet employs a unique momentum air curtain that offers an added measure of containment and protection exclusive to the Baker design. • Creates a strong air barrier, or momentum air curtain, at front of cabinet, increasing protective capabilities for both products and personnel. • Resulting air curtain combines with high-velocity return air slots, aerodynamically contoured front-opening surfaces, and optimum air intake velocity to minimize turbulence and prevent migration of airborne contaminants into or out of the work area. Supply and Exhaust Filters Perform Optimally Because filters remove micro organisms and airborne particulates (e.g., aerosols) from the air, the quality, performance, and useful life of downflow and exhaust HEPA/ULPA filters are critical biosafety considerations. • Leak-free performance is verified through scan tests conducted at the factory prior to shipping and is confirmed at the cabinet’s initial certification. • Closed-cell neoprene gasket provides an airtight seal between the filter assembly and the metal plenum. • VFD motor system and large-sized filters yield the longest filter life in the industry. • An audible/visual airflow alarm and automatic shut-off system called the Airflow Monitor (AFM) warns when the exhaust airflow decreases. Superior technologies and an industry-leading approach to ergonomics ensure a new level of productivity, and user comfort. The BioChemGARD e3, like all Baker cabinets, includes design features to improve safety, productivity, user-comfort, and performance throughout a range of tasks performed on a daily basis. Our cabinets are designed with the user in mind so that routine tasks can be done more comfortably, efficiently, and with less fatigue. Reduced noise levels: The unique airflow design inside the cabinet, combined with the lower exhaust requirements, result in quieter operating noise levels. In standard operating mode, the BioChemGARD e3 emits an average of 50dB*, a 30% decrease in noise on our previous B2 cabinet. This drops to 43dB when the cabinet is in ReadySAFE mode. Efficient lighting: The work area is illuminated by one external fluorescent lamp with an electronic ballast. The cool- white lights use less energy, produce less heat, and provide better color fidelity. *Average tested noise level. Noise level of cabinet is influenced by the building exhaust system. Decibels 10 20 30 40 50 60 70 80 Relative loudness 1/32 1/16 1/8 1/4 1/2 1 2 4 Rustle of Average Normal Traditional Power Leaves Library Office BioChemGARD e3 Conversation B2 Cabinet Mower Momentum Air Curtain High-velocity return air slots maximize protection. EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. PAGE 6 Slanted viewscreen: The slanted sliding viewscreen minimizes glare and makes the cabinet easier and more comfortable to use. A counterbalancing feature allows the user to open and close the laminated safety glass viewscreen effortlessly, which can also be fully closed for ReadySAFE mode, system shutdown, or UV light operation. • Maximum opening of up to 20" simplifies equipment and instrument loading and unloading and allows for placement of large items more easily. • Allows operator more comfortable head and elbow position, reducing fatigue. • Provides safe, highly visible, and easily accessible work area for a wide range of procedures. • Laminated safety glass with a stainless steel edge protector increases durability and safety. Highly productive work environment Design considerations such as wide radius corners, aerodynamically shaped surfaces, and non-glare satin finish interiors combine to improve comfort, simplify cleaning, and maintain proper containment. • Large unobstructed, usable work area can accommodate more lab equipment because of the rear grille being parallel to the straight back wall. • A reduced front grille depth moves the work surface area closer to front of the cabinet for better arm position and less back strain. • Consolidated electrical controls on panel behind hinged light canopy offer unique access outside containment area. • The fluorescent lights, UV light, and the electrical outlets can all be programmed in 15-minute or hour-long intervals to delay the time they power down. • Petcocks, valves, and plumbing connections are strategically placed for convenience and proper air management. • Work surface and walls are one-piece, corrosion-resistant, stainless steel with smooth radius corners for easy cleaning. White powder-coated finish protects cold-rolled steel cabinet exterior. Options and accessories: Most options, accessories, and modifications are factory-installed and should be specified when ordering. Common options are listed below. • Low exhaust static pressure kit • Fume Hood UL 1805 • VHP decon ports • Stainless steel IV bar • UV germicidal lamp • Floor/wall seismic restraints • Black iron pipe • Additional cable port Ordering For ordering information, terms, and conditions of sale, contact The Baker Company or visit the Baker website at bakerco.com for the name of your authorized Baker Company representative. • Reinforced work surface • Remote-controlled petcocks • Electric hydraulic lift • Auxiliary wiring package (for monitoring blower switch status) • ULPA filters • Plastic storage bins • Casters with brakes • Enhanced electrical system with touch pad control panel (GTO1, UL approved) • 220V, 50 Hz Electrical NSF/ANSI 49 & UL listed • Ergonomic adjustable footrest EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. PAGE 7 Detailed Specifications APPROVALS The cabinet shall have the following approvals, listings, and/or certifications: 1. UL 61010-1, Second Edition: Electrical Equipment for Measurement, Control, and Laboratory Use For Electrical, Fire, and Personal Safety 2. NSF/ANSI 49, Biosafety Cabinetry: Design, Construction, Performance, and Field Certification 3. UL 1805, First Edition: Standard for Laboratory Hoods and Cabinets For Material Flammability and Effectiveness of Airflow Characteristics 4. ANSI/ASHRAE 110-1995: Method of Testing Performance of Laboratory Fumehoods PERFORMANCE 1. The cabinet shall provide intake velocity through the front access opening of the cabinet at a minimum of 100 FPM. 2. The cabinet shall incorporate higher-velocity airflow behind the viewscreen (momentum air curtain) for added personnel and product protection. 3. The cabinet shall contain high-velocity return air slots in the sidewalls and top adjacent to the front access opening for enhanced containment and reduction of air turbulence at the sash opening. 4. The cabinet shall incorporate a high-performance airflow system (UniPressure Preflow Plenum™). This system apportions and distributes air across and then through the HEPA supply filter. 5. The bottom of the cabinet access opening shall be aerodynamically designed to direct airflow into the front grille to optimize containment. 6. The cabinet exhaust requirements (Concurrent Balance Value per NSF/ANSI 49) for 12"-diameter exhaust collar, measured directly above the exhaust filter before any restrictions, elbows, or reductions, are: a. BCG401 – 664 CFM at 1.5" water column suction b. BCB601 – 993 CFM at 1.5" water column suction 7. The cabinet sound level as measured per NSF/ANSI 49 shall be no more than: a. 50 dBa – (BCG401 and BCG601) cabinet without background noise b. 60 dBa – (BCG401 and BCG601) cabinet and exhaust system 8. The cabinet shall have a reduced airflow energy-saving mode (ReadySAFE™), which is active when the viewscreen is closed. This mode of operation shall reduce energy consumption by at least 50% and still meet the product and personnel protection testing requirements of NSF/ANSI 49. Particle testing while the cabinet is in this mode shall exceed the requirements for ISO Class 5 conditions for 0.3 micron particles. A connection shall be provided for indicating the ReadySAFE status to the facility building management system. 9. The cabinet shall use a variable frequency drive (VFD) and three-phase motor/blower system (StediFLOW™) that is capable of maintaining a constant air volume as filter resistance increases. The system shall: a. Be capable of automatically handling an increase in pressure drop across the filter of at least 420% (BCG401) without reducing total air volume by more than 10%. b. Operate under normal conditions at a typical current of • BCG401 – 1.0 amp • BCG601 – 1.4 amps c. Automatically compensate for normal power-line variations, air disruptions, and supply filter loading 10. The manufacturer can provide a representative copy of the personnel, product, and cross-contamination biological tests upon request. These tests are equivalent to, or more demanding than, the tests specified in NSF/ANSI 49. Detailed biological test reports can be provided at additional cost. CONSTRUCTION 1. The cabinet’s exterior construction is of seal panels and dress panels of 16-gauge cold-rolled steel, powder-coated finish, PermaWhite™. 2. Exterior dimensions (W x D x H) of the cabinets are: a. BCG401 – 537⁄8 " x 335⁄8" x (86" to 941⁄2") b. BCG601 – 777⁄8 " x 335⁄8" x (86" to 941⁄2") 3. Cabinet shall have permanent metal double-wall construction with negative-pressure airflow between the walls, from drain pan to top of the work area, surrounding all biologically contaminated areas. 4. The cabinet shall contain a vertical sliding viewscreen slanted at an angle of 10° for user comfort. 5. The cabinet shall have an adjustable stand. The available work surface elevations are: a. 295⁄8" to 321⁄8" b. 355⁄8" to 381⁄8" 6. The cabinet interior work area will be constructed as one piece. The material shall be16-gauge, Type-304 stainless steel. The interior shall have smooth coved-corners to facilitate cleaning. 7. The interior dimensions (W x D x H): a. BCG401 – 46" x 227⁄8" x 275⁄8" b. BCG601 – 70" x 227⁄8" x 275⁄8" Usable workspace (W x D x H): a. BCG401 – 445⁄8" x 18" x 275⁄8" b. BCG601 – 685⁄8" x 175⁄8" x 275⁄8" 8. The cabinet shall feature a straight back wall to maximize work area and more easily accommodate laboratory equipment. 9. The cabinet shall have a cable port to allow passage of tubes and/or cables through the negative-pressure double-wall plenum sidewalls of the cabinet. Design shall meet Class 100 (ISO Class 5) air cleanliness immediately inside the opening in the work area. The cabinet feature must be approved per NSF/ANSI 49. 10. The unit shall have standard HEPA filters for a protection effectiveness of 99.99% on 0.3 micron size particles. The cabinet supply filter, exhaust filter, and test ports shall be accessible from the front of the cabinet. 11. The viewscreen shall be constructed of 1⁄4" lami-nated safety plate glass, with a maximum opening of 20" to optimize access to the interior of the cabinet. 12. The cabinet shall feature a counterweighted pulley system to reduce the effort of opening and closing the viewscreen. 13. The cabinet shall be equipped with a stainless steel supply-air diffuser and exhaust-filter protector . 14. The cabinet contains exhaust filters located directly below the work surface. This location facilitates particle capture close to the site of generation. Exhaust filters shall be designed for safe bagging and removal in the work area and shall be sized to fit in a standard Department of Transportation (DOT) container for removal in a manner appropriate to their level of contamination. (ExchangeSAFE™) 15. A plenum assembly shall be provided to allow the supply filters to be directly clamped to the plenum against a closed-cell neoprene gasket. The plenum applies even force, rather than point force, to the full perimeter of the supply filters. 16. The cabinet shall have a unitized drain pan with smooth coved-corners and a fully removable work surface and work-surface supports to facilitate cleaning and prevent microbial growth. 17. The cabinet shall have a bypass armrest for user comfort and to allow intake airflow when the cabinet is in ReadySAFE mode. 18. The standard cabinet shall contain one petcock and one plugged penetration on the right side wall. The left sidewall shall be pre-punched for optional/additional plumbing connections. 19. The cabinet shall be equipped with a stainless steel ball drain valve to allow for safe and effective removal of spills. 20. The supply motor blower shall be located in a clean zone of the cabinet that does not require any decontamination should maintenance or replacement be required. ELECTRICAL 1. The cabinet shall have a microprocessor-based control system with an easy-to-clean membrane control panel mounted on the front of the cabinet. 2. The cabinet shall have adjustable timers for fluorescent lights, outlets, and optional UV lights. Timers shall be able to be set in 15-minute and one-hour increments. 3. The work area of the cabinet shall be provided with two GFCI-protected duplex outlets with drip-proof covers and shall be protected by a self-resetting circuit breaker. 4. A single 14' power cord with NEMA 5-20 plug shall be provided for electrical power connection. 5. The unit shall have an optional UV light. Operation of the UV light is only permitted when the viewscreen is in a closed/safe position. 6. The cabinet shall have electronic ballasts to provide more efficient operation for fluorescent lighting and optional UV lighting. 7. The cabinet shall have an externally mounted fluorescent light fixture capable of providing an average of more than 100 foot-candles of illumination at work surface. 8. The cabinet shall be provided with a low-exhaust-flow alarm. This alarm shall have audible and visual indicators of the alarm condition and be interlocked to shut down the cabinet supply blower, which minimizes pressurization of the work zone in the event of a low-exhaust-flow condition. An audible alarm mute function shall be provided. The alarm shall automatically reactivate after five minutes if the alarm condition persists. 9. The cabinet shall have an audible and visual alarm indicating that the sliding viewscreen is in an unsafe position. An alarm mute function shall be provided to allow the operator full access to the work area. The alarm shall automatically reactivate after five minutes if the viewscreen remains in an unsafe position. BioChemGARD e3, Class II, Type B2 Biological Safety Cabinet, Vertical Flow EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. P.O. Drawer E, Sanford, ME 04073 • (207) 324-8773 • (800) 992-2537 • Fax: (207) 324-3869 • www.bakerco.com © 2011 The Baker Company. All rights reserved. 134-019-11 6/11 Warranty 72 Months The Baker Company, Inc., expressly represents and warrants all goods (a) to be as specified (and described) in The Baker Company catalogs and literature, and (b) to be free under normal use, service, and testing (all as described in The Baker Company catalogs and literature) from defects in material and workmanship for a period of seventy-two months from the invoice date. The exclusive remedy for any breach or violation of this warranty is as follows: The Baker Company, Inc., will F.O.B. Sanford, Maine, furnish without charge repairs to or replacement of the parts or equipment that proved defective in material or workmanship. No claim may be made for any incidental or consequential damages. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE UNLESS OTHERWISE AGREED IN WRITING SIGNED BY THE BAKER COMPANY. (THE BAKER COMPANY SHALL NOT BE RESPONSIBLE FOR ANY IMPROPER USE, INSTALLATION, SERVICE, OR TESTING OF THE GOODS.) Caution A Class II, Type B2, 100% total exhaust biological safety cabinet is suitable for work with low to moderate risk (Biosafety Levels 2 and 3) biological agents. It may also be used with biological agents treated with volatile toxic chemicals and radionuclides required as an adjunct to microbiological studies (as stated by NSF International Standard, NSF/ANSI Standard #49). Note: The adequacy of this containment cabinet for the user’s personal safety, as with any containment cabinet, should be determined by an industrial hygienist or safety officer. Site preparation information, architectural drawings, detailed dimensions, and purchase specifications are available. PROUDLY MADE IN THE U.S.A. MODEL NUMBER BCG401 BCG601 Size 4' 6' Interior Dimensions (w x d x h) 46" x 227⁄8" x 275⁄8" 70" x 227⁄8" x 275⁄8" Usable Workspace (w x d x h) 445⁄8" x 18" x 275⁄8" 685⁄8" x 175⁄8" x 275⁄8" Exterior Dimensions (w x d x h [min to max]) 537⁄8" x 335⁄8" x (86" to 941⁄2") 777⁄8" x 335⁄8" x (86" to 941⁄2") Cabinet Weight (lbs) 720 850 Shipping Weight (lbs) 850 1020 Sash Height 8" 8" Opening Max. 20" 20" Operating Amperage (Normal/ReadySAFE)* (Amps) 1.0 Amps/.3 Amps 1.4 Amps/.3 Amps Power Consumption (Normal/ReadySAFE)* (W) 115 Watts/35 Watts 161 Watts/35 Watts Heat Generation (Normal/ReadySAFE)* (BTU/hr) 392/119 549/119 Note: 100% exhausted Electrical (Requires 20 AMP Outlet) 115V, AC 20A, 60 Hz 115V, AC 20A, 60 Hz Noise, exhaust & cabinet, NSF International (dBa) 59 60 Noise, cabinet (dBa) < 50 < 50 CONCURRENT BALANCE vALUE Exhaust Flow Rate (Total CFM) 664 993 Exhaust Static Press Adjusted Value (Per NSF 49) 12" Diameter Exhaust Collar -1.5" W.G. -1.5" W.G. 10" Diameter Exhaust Collar (Optional) -1.6" W.G. -1.6" W.G. 8" Diameter Exhaust Collar (Optional) -1.7" W.G. -1.7" W.G. Exhaust Flow Rate (Total CFM) (Normal/ReadySAFE) 664/300 993/300 *Values provided under normal, 24 -hour operation and under ReadySAFE mode Performance Data EQUIP# CBS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Applications •IV admixture preparation •Drug compounding •Plant cell culture •Media preparation •Pharmaceutical procedures •Electronic assembly •Limited experimental research Note: Protects product only; does not contain aerosols generated in the work area, and does not protect personnel or the environment. Features Each EdgeGARD®cabinet receives 13 separate performance tests prior to shipment, including complete filter leak tests. A test report accompanies each EdgeGARD®upon delivery. •High velocity return air slots maximize product protection and ensure ISO Class 5 (Class 100) cleanliness. •All models feature non-glare, all stainless steel work surfaces and side walls. •A high performance airflow system provides laminar airflow across the work surface. •HEPA supply filter with 99.99% minimum efficiency in capturing 0.3 micrometer particulates. CSA Listed Underwriter Laboratories Listed Available in Console, and Space-Saver Models. Exceeds ISO-14644 ISO Class 5 (Class 100) Requirements. Featuring Unique High Velocity Return Air Slots EdgeGARD®is a horizontal laminar flow clean bench which provides a HEPA-filtered airflow across the work area, and a particulate-free work surface. Because only HEPA-filtered air crosses the work surface, the cabinet is ideal for a range of life science and industrial laboratory and process applications where clean air and product protection are essential. EdgeGARD® EdgeGARD®Console Model EQUIP# CLF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. High Velocity Return Air Slots Capture Backwash Air Cleanliness and product protection are accomplished with precise control of airflow volumes and velocities. A unique feature in the Baker cabinet design, the high velocity return air slots, have been proven to maximize the clean bench protective capabili- ties. • High velocity return air slots are located along the front edge and side walls of the work area. • Location of the return air slots protects from backwash of dirty air into the work area created when instruments, labware or the user’s hands and arms are placed within the air stream on the work surface. • Air is drawn into these slots at high velocity, ensuring that no unfiltered air enters the work area. • Recovered air is HEPA-filtered before being passed through the work area. • Because recirculated air reduces the percentage of dirty air passed through the filter, overall filter life is extended. HEPA Supply Filter With Prefilter Because filters remove microorgan- isms and airborne particulates (generally called aerosols) from the air, the quality, performance and useful life of HEPA filters are critical considerations in the clean bench environment. • Each Baker clean bench filter is scan tested for leaks and tested for overall efficiency by the manufactur- er, then individually scan tested by Baker after installation to assure leak-free performance with increased trapping efficiency. High velocity return air slots maxi- mize protective capabilities. Fluorescent lighting for 200 foot- candle illumination on work surface. Externally mounted, independent ground-fault circuit interrupt (GFCI) outlets with self-resetting circuit breaker for user safety. Removable protective screen protects HEPA filter. Non-glare work surface. StediVOLT®voltage regulator auto- matically adjusts to typical low and high voltage situations to maintain proper airflow. Hinged panel for easy cleaning. Stainless steel IV bar (optional). Plastic storage bins (optional). 7 9 9 6 6 5 5 4 4 1 1 2 2 3 3 8 8 EdgeGARD®Clean Bench Airflow Characteristics EdgeGARD®employs a laminar air- flow across the work surface. • Clean air is drawn through a prefilter into the base of the console by a blower/motor. • The prefilter traps dust and larger particles. • The air is then pushed up the back wall plenum and through a HEPA filter at an average velocity of 100 FPM. • HEPA-filtered air is directed horizontally across the work surface toward the opening. 7 EdgeGARD® Console Model Page 2 800.992.2537 www.bakerco.com EQUIP# CLF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EdgeGARD° Page 3 • Minimum filter efficiency is 99.99% for particulates 0.3 micrometers, increased efficiency for particulates greater and smaller than 0.3 micrometers. • A removable protective screen is located in front of the HEPA filter. The screen protects the filter and is easily removed for cleaning or service. • The rigid angle steel filter frame is concealed to permit only the filter media to be exposed to the work area, eliminating turbulence created by the frame effect on the rear wall. • All air is passed through a washable, reusable Scottfoam®prefilter which keeps the HEPA filter free of dust and larger particles, and extends HEPA filter life. • The filter need not be changed until the blower/motor system cannot deliver adequate air volume to maintain the average velocity of 100 FPM. StediVOLT® Motor Speed Controller Maintains Optimum Performance The Baker exclusive StediVOLT® motor speed controller reduces the risk of performance degradation and possible product loss due to typical line voltage fluctuations. • StediVOLT®minimizes changes in cabinet performance due to routine voltage fluctuations. • StediVOLT®reads incoming voltage, automatically compensates for low and high voltage, and maintains proper blower speed to prevent periods of unbalanced airflow which may contribute to loss of cleanliness or product protection. Blower/Motor System Helps Extend Filter Life Baker has selected an optimum blower/motor combination to assure performance and to extend filter life. The Baker blower/motor provides a volume of air despite increases in resistance due to filter loading, resulting in extremely long filter life as verified by simulated filter loading tests. Extended filter life minimizes filter replacement costs. The more filter resistance the blower/motor system can overcome, the longer between filter changes. • As particulates fill the filter media, resistance to airflow increases. • The Baker blower/motor is a direct drive permanent split capacitor motor designed to deliver the maximum amount of filter life for each cabinet. • The blower/motor automatically compensates for loading until the filter is fully loaded and motor capacity is reached. Spacious Work Area With Comfortable Lighting • The 22" work area depth provides ample space for safe, efficient opera- tion; heights vary from 281⁄8" to 34 1⁄8", depending on model. • Each EdgeGARD®clean bench includes fluorescent lamps which provide up to 200 foot-candle lighting at the work surface. • The warm, natural illumination exhibits better color fidelity. • Adjustable leg risers (optional) permit work surface heights of 36" and 38". Electrical System Offers Safety and Convenience The EdgeGARD®electrical system is designed for safety and convenience. • An exterior GFCI duplex outlet is provided to accommodate most commonly used instruments and equipment. • The outlet is provided with a 5 amp self-resetting circuit breaker. • The outlets are on a separate circuit from the cabinet lights and blower/motor so that an overload caused by equipment will not affect cabinet function. • For safety reasons, the EdgeGARD® utilizes a single power cord and plug (or junction box) arrangement. This assures that a second power source is not left on if maintenance functions are necessary. • EdgeGARD®is UL and CSA Listed for electrical safety and integrity. StediVOLT® EQUIP# CLF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Cabinet Construction Enhances Performance, Minimizes Downtime Baker cabinet designs represent many years of experience in stainless steel fabrication and craftsmanship. • EdgeGARD®cabinets include a corrosion-resistant Type 304 stainless steel work surface and work area side walls. • A hinged panel located directly below the high velocity return air slots on the leading edge of the work surface provides easy access for cleaning. • A 1⁄2" lip at the rear of the stainless steel work surface prevents spills from entering the HEPA filter. • The satin finish work surface dimin- ishes harsh light reflection. • The 18-gauge cold-rolled steel exte- rior cabinet is protected with a white baked enamel finish. Caution A clean bench is not designed to protect personnel or the environment from potentially harmful agents. The adequacy of this product for the user’s personal safety, as with any clean bench, should be determined by an industrial hygienist or safety officer. Site preparation information, architectural drawings, detailed dimen- sions and purchase specifications are available. Options and Accessories For convenience, most options, accessories and modifications are factory installed and should be specified when ordering. Commonly requested options are listed below. For detailed information on accessories and modi- fications, contact The Baker Company. • Adjustable leg risers (for work surface height of 36" to 38") • Service petcocks (in right or left side wall) • Stainless steel IV bar (removable) • Plastic storage bins (below work surface) • Casters (optional)* • Additional duplex outlet • Isolated/Microbalanced blower/motor (for lowest vibration) • Germicidal UV light—(optional)* • Seismic restraints To Order For ordering information, terms and conditions of sale, contact The Baker Company or visit the Baker Web site at www.bakerco.com for the name of your authorized Baker Company representative. The EdgeGARD®Model EGBIV22 Space Saver is a two-foot clean bench for applications where space is at a premium. Only 28" wide overall,it is typically used for IV and nursing stations, satellite pharmacies, intensive care units and other small volume clinical or industrial situations. *Not UL Listed with this option. Page 4 EQUIP# CLF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Console Models Page 5 EdgeGARD Console C 30 3/8” D Motor/Blower 22” 10” B Prefilter DuplexOutlet Switches HEPA Filter A 34” EdgeGARD®Console Model EdgeGARD® Clean Bench Site Preparation Console Model Numbers: EG3252, EG4252, EG4320, EG5252, EG6252, EG6320, EG8252 Space Saver Model Number: EGBIV22 Cabinet Type: Laminar Flow Clean Bench Filtration System •Supply filter, zero-probed HEPA filter,99.99% efficient on all particles 0.3 micron by DOP test. •Prefilter,washable Scottfoam® •Dust count, leak test and particle count by single particle monitor or cold DOP photometer which conforms to requirements of FS290b and U.S.A.F.T.O. 00-25-203. Illumination •Console and bench models, 200 foot-candles at work surface. •Space-Saver model, 75 foot-candles at work surface. ABC D Model No.Electrical Amps Required Exterior Interior Interior Exterior Net Weight/ Filter Size Breaker Width Width Height Height* Ship Weight EG3252 115V,AC 11.8 15 amps 38" 341⁄2"281⁄8"64" 360/485 lbs 36"x 30"x 6" EG4252 115V,AC 14.2 20 amps 50" 461⁄2"281⁄8"64" 440/590 lbs 48"x 30"x 6" EG4320 115V,AC 14.2 20 amps 50" 46 1⁄2"341⁄8"70" 460/610 lbs 48"x 36"x 6" EG5252 115V,AC 15.5 20 amps 62" 581⁄2"281⁄8"64" 520/695 lbs 60"x 30"x 6" EG6252 115V,AC 18.5 jct box 74" 701⁄2"281⁄8"64" 680/880 lbs 72"x 30"x 6" EG6320 115V,AC 18.5 jct box 74" 701⁄2"341⁄8"70" 720/920 lbs 72"x 36"x 6" EG8252 115V,AC 23.4 jct box 981⁄2"95" 281⁄8"64" 800/1050 lbs 48"x 30"x 6" (2) Note: Models EG4252, EG4320 and EG5252 include 11-foot line cord with 3-prong plug (7-foot cord on Model EG3252). Models EG6252, EG6320 and EG8252 require a hard wire connection to junction box located in the lower inside right hand corner of the cabinet. *Exterior heights are listed as minimum dimensions,for maximum height add 2 inches. Duplex Outlet Blower/Motor HEPA Filter Switches Prefilter A B D C 34" 22" 10" 303⁄8" EdgeGARD° EQUIP# CLF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. OW8006 2/06 P.O. Drawer E, Sanford, Maine 04073 (207) 324-8773 1-800-992-2537 FAX (207) 324-3869 www.bakerco.com ©2006 The Baker Company EdgeGARD° Purchase Specification EdgeGARD®Horizontal Laminar Flow Clean Bench 1. High velocity return air slots to be located at the leading edges of work surface and side walls. Return air slots protect against backwash of dirty air entering the work area when items are placed within the air stream on the work surface. 2. Unit shall be all steel construction, 18- gauge, cold-rolled steel, with a white baked enamel finish and stainless steel work surface and stainless steel inner work area side walls. 3.Unit shall be provided with permanent split capacitor type motor and special blower which automatically compensates for increasing pressure drop across filter in excess of that which is required by existing standards. 4. Complete unit shall be listed as certified by Canadian Standards Association (CSA) and Underwriters Laboratory (UL) for electrical, fire and personal safety. 5. All joints and seams offering a possible path of contaminated air from outside to the inside of the work area shall be sealed. 6. Framing for the filter seal shall be of rigid angle steel construction and only the filter media shall be exposed to the work area opening, to eliminate picture frame effect. 7. Unit shall have washable reusable Scottfoam® prefilters. 8. Each unit, before shipping, shall have a complete test to assure hood meets all requirements of ISO-14644. A copy of this test will be provided with the unit. 9. The unit manufacturer must be able to provide evidence that this unit has been tested by an inde- pendent laboratory or research organization. 10. Speed controller shall automatically compensate for voltage change to maintain constant voltage to motor while allowing for manual adjustments dur- ing filter loading. 11. Unit work surface shall feature 1⁄2"lip at rear to prevent accidental spillage into HEPA filter area. 12. The unit shall have standard HEPA filters for a protection effectiveness of 99.99% when f iltering particles of 0.3 micron size. EdgeGARD Space Saver 22” 43” 22” PowerCord IV Bar(option) FluorescentLight Box DuplexOutlet Switches 27” Motor/BlowerPrefilter HEPA Filter EdgeGARD®Space Saver Model Space Saver Model Model No. Electrical Amps Required Net Weight/ Filter Size Breaker Ship Weight EGBIV22 115V,AC 11.2 15 amps 200/325 lbs 24"x 24"x 6" Note:This model includes a 9-foot line cord with 3-prong plug. Fluorescent Light Box Power Cord Duplex Outlet IV Bar (option) HEPA Filter Blower/MotorPrefilter22" 43" 22" 27" Switches 13. A removable HEPA filter protective screen shall be provided. 14. Work area shall be provided with externally mounted GFCI protected duplex outlet with circuit breaker. Warranty The Baker Company,Inc., expressly represents and warrants all goods (a) to be as specified (and described) in The Baker Company catalogs and literature, and (b) to be free under normal use, service and testing (all as described in The Baker Company catalogs and literature) from defects in material and workmanship for a period of thirty-six months from the invoice date. The exclusive remedy for any breach or violation of this war- ranty is as follows: The Baker Company, Inc., will F.O.B. Sanford, Maine, furnish without charge repairs to or replacement of the parts or equipment which proved defective in material or workmanship. No claim may be made for any incidental or consequential damages. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE UNLESS OTHERWISE AGREED IN WRITING SIGNED BY THE BAKER COMPANY. (THE BAKER COMPANY SHALL NOT BE RESPONSIBLE FOR ANY IMPROPER USE, INSTALLATION, SERVICE OR TESTING OF THE GOODS.) EQUIP# CLF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Ò Item#_______________________________________________ Job _________________________________________________Utility Carts Series MW200, MW300, MW400, MW700Ò InterMetro Industries Corporation North Washington Street Wilkes-Barre, PA 18705 www.metro.com Ò12.05SUPER ERECTA SHELF® MW UTILITY CARTS– THREE-SHELF MODELS •Attractive and thoroughly practical, these carts are offered as complete units, shipped knocked down, with all components packaged in a compact carton. •Super Erecta Shelf®Construction makes units easy to assemble with absolute rigidity, and makes relocation of shelves quick and simple. •Choice of 26 Three-Shelf Models: Four different shelf combinations, each in five to ten different variations. MW200 Series - Three stainless steel flat shelves. Six sizes. Stainless steel handles, except chrome handles on MW201. MW300 Series - Two stainless steel flat shelves and one chrome wire shelf. Five sizes. Chrome handles. Wire shelf can be located top, middle or bottom. MW400 Series - Two chrome wire shelves and one stainless steel flat shelf. Five sizes. Chrome handles. Solid shelf can be positioned top, middle or bottom. MW700 Series - Three wire shelves, choice of chrome or stainless steel. Five sizes; ten models. Handle material matches shelves. •Wire Shelves:Bright, modern, sanitary appearance. Open construction minimizes dust accumulation, maximizes visibility and air circulation. •Solid Shelves:Ideal for transporting materials that require an expanse of flat surface. Raised ship’s edge permits fast clean-up in case of liquid spills. Double thickness of 18-gauge steel at edges also gives rigidity and high strength. •Casters:Standard-duty. 4LD 4” (102mm) diameter casters on carts 18” (455mm) wide; 5LD 5” (127mm) diameter casters on carts 21” (530mm) and 24” (610mm) wide. See sheet #11.20 for additional information on casters. •Donut Bumpers •One-Piece Handle •Height:38” (965mm) floor to handle with 4” (102mm) casters; 39” (991mm) floor to handle with 5” (127mm) casters. •Replaceable Parts:If any part of any cart is damaged by use, replacement parts are readily available and easily installed. •Accessories:A wide variety is available to increase usefulness. See sheet #12.20. Copyright © 1979 Metropolitan Wire Corp MW700 Series MW200 Series MW300 Series MW400 Series EQUIP# CRT04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION Job____________________________________________ MW UTILITY CARTS THREE-SHELF MODELS Ò DIMENSIONS: Approx. Width Length Pkd. Wt.Casters Model (in.)(mm)(in.)(mm)(lbs.)(kg)Shelves Shelf Mat.Handles (in.)(mm) MW203 18 455 24 610 48 21.8 3-S SS SS 4 102 MW204 18 455 30 760 53 24.0 3-S SS SS 4 102 MW205 18 455 36 910 59 26.8 3-S SS SS 4 102 MW206 21 530 36 910 66 29.9 3-S SS SS 5 127 MW208 24 610 36 910 74*33.6 3-S SS SS 5 127 MW301 18 455 24 610 46 20.9 2-S SS Chrome 4 102 1-W Chrome MW302 18 455 30 760 52 23.6 2-S SS Chrome 4 102 1-W Chrome MW303 18 455 36 910 57 25.9 2-S SS Chrome 4 102 1-W Chrome MW304 21 530 36 910 62 28.1 2-S SS Chrome 5 127 1-W Chrome MW306 24 610 36 910 69 31.1 2-S SS Chrome 5 127 1-W Chrome MW401 18 455 24 610 43 19.5 1-S SS Chrome 4 102 2-W Chrome MW402 18 455 30 760 47 21.3 1-S SS Chrome 4 102 2-W Chrome MW403 18 455 36 910 52 23.6 1-S SS Chrome 4 102 2-W Chrome MW404 21 530 36 910 59 26.8 1-S SS Chrome 5 127 2-W Chrome MW406 24 610 36 910 65 29.5 1-S SS Chrome 5 127 2-W Chrome MW701 18 455 24 610 39 17.6 3-W Chrome Chrome 4 102 MW702 18 455 24 610 38 17.2 3-W SS SS 4 102 MW703 18 455 30 760 43 19.5 3-W Chrome Chrome 4 102 MW704 18 455 30 760 42 19.1 3-W SS SS 4 102 MW705 18 455 36 910 47 21.3 3-W Chrome Chrome 4 102 MW706 18 455 36 910 45 20.4 3-W SS SS 4 102 MW707 21 530 36 910 50 22.7 3-W Chrome Chrome 5 127 MW708 21 530 36 910 50 22.7 3-W SS SS 5 127 MW711 24 610 36 910 60 27.2 3-W Chrome Chrome 5 127 MW712 24 610 36 910 57 25.9 3-W SS SS 5 127 *Cannot be shipped UPS S-Solid Shelving W-Wire Shelving SS-Stainless Steel For utility cart accessories, refer to sections 10.05 and 10.06. Manufactured by: InterMetro Industries Corp. North Washington Street Wilkes-Barre, PA 18705 For Product Information, call 1-800-433-2232 Ò InterMetro Industries Corporation North Washington Street Wilkes-Barre, PA 18705 www.metro.com L02-055 Rev. 3/98 BJ Printed in U.S.A. Information and specifications are subject to change without notice. Please confirm at time of order.Utility Carts Series MW200, MW300, MW400, MW700Ò12.05EQUIP# CRT04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION GE Healthcare Trophon EPR Distributed exclusively by GE Healthcare, the Trophon® EPR is a complete ultrasound transducer High-Level Disinfection system that’s fast, easy to use, environmentally friendly and quality assured. It uses a unique platform technology to effectively disinfect the transducer, including the shaft and handle—in just seven minutes between patients. When used as directed the Trophon EPR meets guidelines set forth by the FDA and CDC for High-Level Disinfection. For sale in the U.S. and Canada only. Trophon EPR Catalog # E8350NA Trophon Mobile Cart Catalog # E8350NH 34.5'' H x 20'' W x 20.5'' D 45 lbs. 21 kg. Trophon Wall Mount Catalog # E8350NG 8.6'' H x 6.7'' W x 2.0'' D 3 lbs. 1.35 kg. Trophon Sonex-HL™ Catalog # E8350NJ 6 cartridges/box Approx. 240 cycles Trophon Chemical Indicators Catalog # E8350NC 300/pkg. 1" 26 mm Consumables We are your one-stop shop for Trophon EPR consumable supplies. Accessories The Trophon EPR can stand alone or for convenient point-of-care options, we offer both the Trophon Mobile Cart and Wall Mount solution. EQUIP# DIS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ACCD-0198-05.12-EN-US DOC0992431 ©2012 General Electric Company – All rights reserved. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. *GE and GE Monogram are trademarks of General Electric Company. Trophon EPR is a registered trademark of Nanasonics Limited. Sonex-HL is a trademark of Nanosonics Limited. GE Healthcare, a division of General Electric Company. System specifications GE Healthcare 3000 North Grandview Waukesha, WI 53188 U.S.A. www.gehealthcare.com imagination at work System Specifications Cycle Time 7 minutes Cycle Verification Via User Screen, Chemical Indicator and Electronic Log. Sonex-HL Minimum Concentration 31.5% Minimum Disinfectant Dose 1.0 g Volume – 80 ml, approx. 40 cycles/cartridge Shelf Life – 2 years Chemical Indicators The Chemical Indicators are used exclusively for monitoring the High-Level Disinfection process when placed within the Trophon EPR chamber. Refer to the Chemical Indicator Color Assessment Chart for cycle verification information. Probe Compatibility Please check with your transducer manufacturer regarding compatibility with the Trophon EPR. You can also find a validated transducer list at www.trophon.com Electrical Specifications Electrical Requirements Input Voltage: 120V AC Input Current: 5 Amp/50-60 Hz Agency Approvals UL61010-1:2004 R10.08, IEC61010-2-040:2005, CAN/CSA-C22.2 NO. 61010-1-04+GI1 (R2009), CAN/CSA-C22.2 NO. 61010-2-040-07 EMC Compliance EN61326-1:2006 FCC Rules Part 15 Subpart B Unintentional Radiators, Class B Digital Devices ANSI C63.4:2009 Mechanical Specifications Trophon EPR 19.3'' H x 13.6'' W x 13.6'' D / 38 lbs. 490 mm x 345 mm x 345 mm / 17 kg Ordering is simple. Order your Trophon EPR system, accessories, and consumable supplies with the method most convenient for you. Call: 800-558-5102, opt. 2, opt. 1 Fax: 877-279-6990 Email: gehcaccessorysales@ge.com Contact: Your local GE representative Visit www.gehealthcare.com/trophon EQUIP# DIS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 1-800-962-9888 Multi-Purpose Containers Horizontal-Drop Opening Lid Code Description Dimensions Ship Case 89651 2 Gallon, Red 12.75”H x 7.25”D x 10.5”W 20 89671 2 Gallon, Transparent Red 12.75”H x 7.25”D x 10.5”W 20 Muti-Purpose Sharps Containers with Sliding Lid Code Description Dimensions Ship Case 31143699 1 Gallon, Red 6.25”H x 7”D x 10.5”W 32 31142222 2 Gallon, Red 10.25”H x 7”D x 10.5”W 20 Monoject™ Sharps Containers Code Description Dimensions Ship Case Monoject™ Vertical Drop Containers 8881676236 4 Quart Red, Small 6.75”W x 10.56”L x 7.08”H 40 8881676285 8 Quart Red, Medium 6.75”W x 10.56”L x 10.89”H 20 8881676434 14 Quart Red, Large 6.75”W x 10.56”L x 17.77”H 10 89671 31143699 31142222 8881676236 EQUIP# DSS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 1-800-962-9888 SharpSafety™ Brackets, Holders and Accessories 8528C 8912SA 8881676285 8518X 8975 Brackets, Holders and Accessories • Locking wall brackets are unobtrusive and securely hold container in place. • All brackets are keyed alike for your convenience. • Adhesive-backed holders can be mounted in trays or countertops to help secure container and standardize sharps disposal locations. • OSHA Regulation 29 CFR 1910.1030(d)(4)(iii), “During use, containers for contaminated sharps shall be maintained upright throughout use...” • Covidien offers a complete line of brackets and holders to ensure your safety and compliance. Code Description Dimensions Ship Case 8518X Locking Bracket for 2 & 5 Quart 8.25”H x 6.5”D x 11.25”W 5 In-Room™ Containers 8519C Non-Locking Bracket for 2 & 5 8.25”H x 6.5”D x 11.25”W 5 Quart In-Room™ Containers 8524C Non-Locking Bracket for 3 Gallon 11.75”H x 6.5”D x 13.75”W 5 Multi-Purpose and 2 & 3 Gallon In-Room™ Containers 8528C Locking Bracket for 3 Gallon 11.75”H x 6.5”D x 13.75”W 5 Multi-Purpose and 2 & 3 Gallon In-Room Containers 8543C Locking Bracket for 11.75”H x 6.5”D x 13.75”W 5 SharpStar™ IV 3 & 4 Gallon In-Room™ Containers 8912SA Wall Bracket for 1 Quart 5”H x 4.25”D x 5”W 5 Phlebotomy Containers 8963 Locking Bracket for 2 Gallon 8.25”H x 7.5”D x 11.5”W 5 Multi-Purpose, RCRA, Pharmaceutical and Chemosafety™ Containers 8975 Wall Bracket for 2 Gallon 7.5”H x 6.5”D x 10”W 5 Multi-Purpose, RCRA, Pharmaceutical Chemosafety™ Containers 8984 Locking Wire Bracket for 8 5 Gallon Large Volume Containers 18”H x 9.75”D x 15.5”W 8984 EQUIP# DSS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 1-800-962-9888 Container CoDe Container Volume Container Waste Disposal HarDWare number HarDWare DesCription HarDWare Case QtyloCking braCket? 8934 12 Gallon Chemotherapy 8938FP Foot Pedal Cart 1 each 8934 12 Gallon Chemotherapy 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8934 12 Gallon Chemotherapy 8992H Floor Bracket w/Wheels 1 each 8934PG2 12 Gallon Chemotherapy 8938FP Foot Pedal Cart 1 each 8934PG2 12 Gallon Chemotherapy 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8934PG2 12 Gallon Chemotherapy 8992H Floor Bracket w/Wheels 1 each 8935 12 Gallon Biohazard 8938FP Foot Pedal Cart 1 each 8935 12 Gallon Biohazard 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8935 12 Gallon Biohazard 8992H Floor Bracket w/Wheels 1 each 8936PG2 12 Gallon Biohazard 8938FP Foot Pedal Cart 1 each 8936PG2 12 Gallon Biohazard 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8936PG2 12 Gallon Biohazard 8992H Floor Bracket w/Wheels 1 each 8936SA 12 Gallon Biohazard 8938FP Foot Pedal Cart 1 each 8936SA 12 Gallon Biohazard 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8936SA 12 Gallon Biohazard 8992H Floor Bracket w/Wheels 1 each 8938 18 Gallon Biohazard 8938FP Foot Pedal Cart 1 each 8938 18 Gallon Biohazard 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8938 18 Gallon Biohazard 8992H Floor Bracket w/Wheels 1 each 8939 18 Gallon Chemotherapy 8938FP Foot Pedal Cart 1 each 8939 18 Gallon Chemotherapy 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8939 18 Gallon Chemotherapy 8992H Floor Bracket w/Wheels 1 each 8939PG2 18 Gallon Chemotherapy 8938FP Foot Pedal Cart 1 each 8939PG2 18 Gallon Chemotherapy 8940FP Molded Plastic Foot Pedal Cart √ 1 each 8939PG2 18 Gallon Chemotherapy 8992H Floor Bracket w/Wheels 1 each 8950SA 5 Quart Biohazard N/A N/A N/A 8964 3 Gallon Biohazard Wire Bracket 5 each 8964 3 Gallon Biohazard 8528C Wire Bracket √ 5 each 8964 3 Gallon Biohazard 8529 Table Top Holder 5 each 89651 2 Gallon Biohazard 8963 Wire Bracket √ 5 each 89651 2 Gallon Biohazard 8974 Table Top Holder 5 each 89651 2 Gallon Biohazard 8975 Wire Bracket 5 each 89671 2 Gallon Biohazard 8963 Wire Bracket √ 5 each 89671 2 Gallon Biohazard 8974 Table Top Holder 5 each 89671 2 Gallon Biohazard 8975 Wire Bracket 5 each 8967MW 2 Gallon Biohazard 8963 Wire Bracket √ 5 each 8967MW 2 Gallon Biohazard 8974 Table Top Holder 5 each 8967MW 2 Gallon Biohazard 8975 Wire Bracket 5 each 8970 2 Gallon Biohazard 8963 Wire Bracket √ 5 each 8970 2 Gallon Biohazard 8974 Table Top Holder 5 each 8970 2 Gallon Biohazard 8975 Wire Bracket 5 each 8979C 2 Gallon Biohazard 8963 Wire Bracket √ 5 each 8979C 2 Gallon Biohazard 8974 Table Top Holder 5 each 8979C 2 Gallon Biohazard 8975 Wire Bracket 5 each 8979MW 2 Gallon Biohazard 8963 Wire Bracket √ 5 each Hardware and Container Cross Reference Guide EQUIP# DSS01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Rx Waste Compliance Service Keeping Pharmaceuticals Out of the Water Waste2Green4Healthcare® PRODUCT GUIDE PROTECTING PEOPLE. REDUCING RISK.TM EQUIP# DSS03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Rx waste 2 COntaineR OptiOnS 8 Gallon Container Code # C-08BLUENON-PH, C-08BLKHAZ-PH, C-08PURP-PH For increased capacity, the 8 gallon container is utilized in intensive care, pharmacies, and inpatient units. 2 Gallon Container Code # C-02BLUENON-PH, C-02BLKHAZ-PH, C-02PURP-PH Our 2 gallon containers are appropriate for patient rooms and medication areas where security and convenience are critical. 4 Gallon Container Code # C-04BLUENONVER-PH, C-04PURP-PH Our 4 gallon containers are appropriate for patient rooms and medication areas where security and convenience are critical. 17 Gallon Container Code # C-17BLUENON-PH The 17 gallon container is appropriate for high use areas. State-of-the-art Rx Waste color-coded containers.Non-Hazardous Hazardous, Incompatible, and Universal Dual EQUIP# DSS03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Lid OptiOnS Horizontal drop Lid This lid is perfect when space constraints do not allow sufficient room for a vertical drop. trap top Lid The trap top lid can be used with the wire step-on dolly. Hamper top Lid The hamper top lid has been designed for easy operation and can accommodate large amounts of Rx waste. When the lid is raised, it provides an opening of 12 inches by 8.5 inches. Used with the wire step-on dolly. Vertical drop Lid Vertical drop lid allows for simple, single-handed disposal of Rx waste. 3 EQUIP# DSS03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Rx waste 4 BRaCket, BaSe OR dOLLy OptiOnS 4 Gallon Locking Wire Wall Bracket Code # WB-04Blue The 4 gallon locking wire wall bracket is constructed of durable powder coated steel. Countertop Stability Base Code # 0203SB To free up valuable wall space, our durable resin countertop stability base affixes a 2 or 3 gallon container to any flat, stable surface. The base can be attached to the surface with semi-permanent adhesive strips or screws. Locking Wall Mount Code # 0203WMA The locking wall bracket mounts to any vertical surface and accommodates the 2 or 3 gallon containers. 8 Gallon Locking Wire Wall Bracket Code # WB-08Blue The locking wire wall bracket, constructed of a durable powder-coated steel, allows the 8 gallon container to be mounted to any vertical surface. EQUIP# DSS03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. PRODUCT CODES 8 product Code description approximate dimensions (Height x depth x Width) BLUE CONtAiNERS C-02BLUECOMP-PH 2 Gallon Blue Compatible w/ Vertical Lid 15.1” x 4.73” x 12.5” C-02BLUENON-PH 2 Gallon Blue Non-Hazardous w/ Vertical Lid 15.1” x 4.73” x 12.5” C-02BLUENONWA-PH 2 Gallon Blue Non-Hazardous w/ Vertical Lid (WA) 15.1” x 4.73” x 12.5” C-02BRX-0203 2 Gallon Blue California w/ Vertical Lid 15.1” x 4.73” x 12.5” C-03BRX-0203 3 Gallon Blue California w/ Vertical Lid 21.1” x 4.73” x 12.5” C-04BLUECOMPHOR-PH 4 Gallon Blue Compatible w/ Horizontal Lid 21.25” x 6.81” x 12.25” C-04BLUECOMPVER-PH 4 Gallon Blue Compatible w/ Vertical Lid 21.25” x 6.81” x 12.25” C-04BLUENONHOR-PH 4 Gallon Blue Non-Hazardous w/ Horizontal Lid 21.25” x 6.81” x 12.25” C-04BLUENONHORWA-PH 4 Gallon Blue Non-Hazardous w/ Horizontal Lid (WA) 21.25” x 6.81” x 12.25” C-04BLUENONVER-PH 4 Gallon Blue Non-Hazardous w/ Vertical Lid 21.25” x 6.81” x 12.25” C-04BLUENONVERWA-PH 4 Gallon Blue Non-Hazardous w/ Vertical Lid (WA) 21.25” x 6.81” x 12.25” C-04BRX-04H 4 Gallon Blue California w/ Horizontal Lid 21.25” x 6.81” x 12.25” C-04BRX 4 Gallon Blue California w/ Vertical Lid 21.25” x 6.81” x 12.25” C-08BLUECOMP-PH 8 Gallon Blue Compatible w/ Trap Top Lid 19.7” x 12.95” x 11.25” C-08BLUENON-PH 8 Gallon Blue Non-Hazardous w/ Trap Top Lid 19.7” x 12.95” x 11.25” C-08BLUENONWA-PH 8 Gallon Blue Non-Hazardous w/ Trap Top Lid (WA) 19.7” x 12.95” x 11.25” C-08BRX-2004 8 Gallon Blue California w/ Trap Top Lid 19.7” x 12.95” x 11.25” C-17BLUECOMP-PH 17 Gallon Blue Compatible (Hamper Top Lid Ordered Separately) 24.75” x 17.5” x 13.25” C-17BLUENON-PH 17 Gallon Blue Non-Hazardous (Hamper Top Lid Ordered Separately) 24.75” x 17.5” x 13.25” C-17BLUENONWA-PH 17 Gallon Blue Non-Hazardous (Hamper Top Lid Ordered Separately) (WA) 24.75” x 17.5” x 13.25” LH-17 Hamper Top Lid for 17 Gallon 17.25” x 12.62” BLACK CONtAiNERS C-02BLKCOR-PH 2 Gallon Black Corrosives w/ Vertical Lid 15.1” x 4.73” x 12.5” C-02BLKOXi-PH 2 Gallon Black Oxidizer w/ Vertical Lid 15.1” x 4.73” x 12.5” C-02BLKAER-PH 2 Gallon Black Aerosols w/ Vertical Lid 15.1” x 4.73” x 12.5” C-02BLKFLA-PH 2 Gallon Black Flammables/Toxic w/ Vertical Lid 15.1” x 4.73” x 12.5” C-02BLKHAZ-PH 2 Gallon Black Hazardous Waste w/ Vertical Lid 15.1” x 4.73” x 12.5” C-02BLKHAZMi-PH 2 Gallon Black Universal Waste w/ Vertical Lid (MI) 15.1” x 4.73” x 12.5” COntaineR, BRaCket, BaSe, and dOLLy COdeS EQUIP# DSS03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. product Code description approximate dimensions (Height x depth x Width) BLACK CONtAiNERS C-02BLKHAZFL-PH 2 Gallon Black Universal Waste w/ Vertical Lid (FL) 15.1” x 4.73” x 12.5” C-08BLKHAZMi-PH 8 Gallon Black Universal Waste w/ Trap Top Lid (MI) 19.7” x 12.95” x 11.25” C-08BLKHAZFL-PH 8 Gallon Black Universal Waste w/ Trap Top Lid (FL) 19.7” x 12.95” x 11.25” C-08BLKCOR-PH 8 Gallon Black Corrosives w/ Trap Top Lid 19.7” x 12.95” x 11.25” C-08BLKOXi-PH 8 Gallon Black Oxidizer w/ Trap Top Lid 19.7” x 12.95” x 11.25” C-08BLKAER-PH 8 Gallon Black Aerosols w/ Trap Top Lid 19.7” x 12.95” x 11.25” C-08BLKFLA-PH 8 Gallon Black Flammables/Toxic w/ Trap Top Lid 19.7” x 12.95” x 11.25” C-08BLKHAZ-PH 8 Gallon Black Hazardous Waste w/ Trap Top Lid 19.7” x 12.95” x 11.25” PURPLE CONtAiNERS C-02PURP-PH 2 Gallon Purple w/ Vertical Lid 15.1” x 4.73” x 12.5” C-04PURP-PH 4 Gallon Purple w/ Horizontal Lid 21.25” x 6.81” x 12.25” C-08PURP-PH 8 Gallon Purple w/ Trap Top Lid 19.7” x 12.95” x 11.25” BRACKEtS 0203WMA 2 & 3 Gallon Locking Wall Mount (Beige) (Key is Ordered Separately) 2.75” x 5.75” x 13” KOC-0203 Key For Locking Wall Mount 0203SB 2 & 3 Gallon Countertop Stability Base (Beige) 4.25” x 7.01” x 11.99” WB-04Blue 4 Gallon Locking Wire Wall Bracket (Blue) 7.12” x 7.75” x 13.62” WB-08Blue 8 Gallon Locking Wire Wall Bracket (Blue) 21.5” x 13.25” x 14” D-08Blue 8 Gallon Locking Wire Dolly (Blue) 23” x 13” x 13.5” DWS-08Blue 8 Gallon Locking Wire Step-On Dolly (Blue) 23” x 16.5” x 14.25” DWSH-17Blue 17 Gallon Locking Wire Step-On Dolly (Blue) for Hamper Top Lid 29.75” x 22.5” x 14.5” 10KA-L23 Lock and Key for Dollies and Wire Brackets D-17 17 Gallon Black Dolly (Black) 9.75” x 19” x 14.25” For questions about Rx Waste Products please call (866) 338-5120. 9 EQUIP# DSS03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ® ® Instruction Manual U.S. & International Patent Pending CactusLLC.net EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 20WAYS Summer 2011 iSSue i health SyStem • infuSion 11 improving patient care & pharmacy cost containment The SMART SINK™ system securely stores and acutely renders unused drugs unusable and unrecoverable, and can be installed in any location where drugs are typically administered. This new, innovative system accepts pills, patches and liquids and utilizes secured disposable cartridges for proper pharmaceutical waste disposal. SMART SINK™ A “Go Green” Alternative for Pharmaceutical Waste Disposal Company Background Cactus™, LLC and the SMART SINK™ concept was developed by its CEO and founder, Dave Maness to provide a simple and environmentally- friendly solution for pharmaceutical waste. Cactus™, LLC is located in Charleston, SC and will soon be providing secured pharmaceutical waste solutions to health care facilities in the US and Canada. Product Overview The Cactus™ Smart Sink™ is designed to safely and easily dispose of pharmaceutical waste that would otherwise be discarded in a sharps container, waste bin, toilet or sink. This innovative, “Go Green” system helps bring your medical facility into compliance by simplifying the pharmaceutical waste process. It also acutely renders drugs “unrecoverable” and unusable so discarded pharmaceutical waste doesn’t end up in the wrong hands, or negatively impact the environment. The Cactus™ Smart Sink™ allows for a careful balance of pharmaceutical waste control and environmental concern. The SMART SINK™ can be installed in any location, or where drugs are typically administered. This secured system renders unused drugs unrecoverable in the acute setting, protects the environment, and significantly reduces opportunities for drug diversion. Typical Hospital Locations Nursing Stations, Patient Rooms, Next to drug dispensing equipment, labs, OR, ER, Cath Labs, Procedure rooms, Surgery Centers, Radiology, Portable Patient Carts, Hospital Pharmacies, ICU, CCU, Oncology, Outpatient Centers Product Specifications • Counter Top or Wall Mounted • SMART SINK™ dimensions: 15½" wide x 12½" tall x 9½" deep • Current Capacity: Liquids Cartridge - 3. 8 liters* Solids Cartridge - 1.7 liters* *Capacity is approximate Testimonials “ We are excited about the upcoming release of the new Cactus Smart Sink™. After using the product in our nursing units, we anticipate not only more efficient use of our nurses’ time, but a more secure and environmentally friendly process to dispose of medication waste.” — Fred Bender, PharmD/Director, Pharmacy Services Greenville Hospital System University Medical Center, Greenville, SC “ I have had the opportunity to observe the Cactus Smart Sink™ from its concept to the innovative waste product it is today. The Smart Sink™ uses clean, convenient and green technology to address the regulatory compliance of small drug waste needs that were previously disposed of in the regular waste stream.” — Phil Creger, Pharm.D, MHA Director of Pharmacy Roper, Saint Francis Healthcare Charleston, SC CEO: Dave Maness Founded: January 2010 Employees: <50 Phone: (843) 856-7400 Fax: (843) 856-7408 Address: 1031 Le Grand Blvd. Charleston, SC 29492 Website: www.cactusLLC.net Going Green Cactus™, LLC is the first to offer a secured, “Go Green” concept for pharmaceutical waste to help protect our environment. Key Business Partners Canada Distributor: Manrex Limited Winnipeg, Manitoba Canada www.manrex.com Markets Served Hospitals, Surgery Centers, Hospice, Long Term Care Facilities, Clinics, Mental Health Facilities, Veterinary Clinics, Police Departments, Home Infusion, Retirement Homes, Drug Labs, Military DOD, Private Practice Trade Shows ASHP, AHE, NADDI, NASCSA, Clean Med, Health Connect Partners, SCSHP, NCPA GPO Affiliations Current GPO Partners: Amerinet, Main Street Vaccines, VA, US Government, Other GPO’s pending Ordering Information To order: Web site: www.cactusLLC.net Contact: Sales@cactusLLC.net Call: 843-856-7400 Fax: 843-856-7408 Nursing Suite SMART SINK™ application Greenville Memorial Hospital, Greenville, SC. Photo by: Randy Hadaway Cac usTM Responsible PharmaceuticalWasteDisposalSystems™ GO GREEN! WeProudlyUse EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ®LLC.net US & International Patent Pending Reference Diagrams Liquids Alert Light Security Lock & Key Liquids Funnel Patch Slot / Plunger Solids Funnel Solids Alert Light Power Light Low Battery Light Left Lid Catch Solids Cartridge Solids Locking Cap Cartridge Handle Storage Sound On / Off Switch Bracket Release Liquids Locking Cap Security Lock Patch Slot Pill Funnel Liquids Barrier Screen Liquids Cartridge Reset Button Fast Fill Button EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ®LLC.net Determining Location WALL MOUNT OR COUNTERTOP MOUNTForSMART SINK ®mounting locations,follow your facilityʼs recommended guidelines. NURSING STATIONS / PROCEDURE ROOMSThe Cactus®SMART SINK ®system should be located at the pointof use where pharmaceuticals are used or administered. Examples include:nursing stations, emergency rooms, procedure rooms, ICU, CCU, hospitalpharmacy, or any area where any volume of “wasting” is required.The Cactus ®SMART SINK ®should be located at the same level,on the wall, for example,next to or near a wall mounted sharps container.The need for electrical outlets is not necessary since the unit ispowered by batteries for approximately twelve months. The ideal mounting height is 32 to 40 inches from the floor to the bottom of the unit. Countertop mounting isoptional.(see mounting bracket installation instructions). Make sure that the Cactus ® SMART SINK ®system is adequately secured to a wall or counter top utilizing theenclosed hardware package.The bracket must be able to withstand over 25 pounds of force to stay secured.See installation instructions. - Page 10 - Universal Bracketwill allow forwall mountingor counter topmounting. EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ®LLC.net Installation and Set Up Unpack the Cactus®SMART SINK ®unit, one solids cartridgeand one liquids cartridge. The location must be best suited for visibilityand easy access, similar to sharps container guidelines. See quick set up guide attached to instruction manual.DO NOT INSTALL CARTRIDGES UNTIL STEPS 2 THROUGH 5 ARE COMPLETE!Install lock set. A lock set and two security keys are included with each Cactus® SMART SINK ®. If needed, keys can be the same for all Cactus ®SMART SINK ®units by facility. The lock set is included with each unit and must be installed for the SMART SINK®system to work correctly. The top cover will not lock into place unlessthe lock set is installed. See “LOCK SET INSTALLATION INSTRUCTIONS” on page 15.Install security bracket. See BRACKET INSTALLATION INSTRUCTIONS on page 13.Locate timer switch in battery compartment. Set the timer switch to the desiredexpiration time – “30,60, 90 or ∞(infinity) days. Timer is preset to the 60 day positionfrom the factory. Locate the sound on/off switch. Set the audible alarm switch to “on”or “off” position. Alarm sound switch is preset to “on” position from the factory.IMPORTANT: Remove plastic tabs before installing the battery.Install the battery included with the unit, and secure the battery cartridge withthe security screw that is attached. Replace the battery every twelve months orwhen the low battery indicator light is on.See “low battery” indicator on unit.After inserting battery, make sure red lights are flashing and alarm is sounding.Remove the two shipping screws and labels from the bottom of both cartridge slotsas shown below by turning them counter clockwise. Removal of the shippingscrews will allow for proper insertion of cartridges. Shipping screws can beremoved by hand without a screwdriver. (Screws are optional based on unit model #). - Page 11 - 1. 2. 3. 4. 5. 6. EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Labeling your Cactus®SMART SINK ®. Determine classification of waste to beintroduced into the Cactus ®SMART SINK ®system. Affix appropriate labels tothe Cactus®SMART SINK ®and to the cartridges.Remove the factory sealed safety cap on the solid and liquid cartridges. Onlyremove factory sealed safety cap when cartridges are ready for use. In order topreserve the media and contents, stored liquid and solids cartridges must havethe seal intact until ready for use. The blue permanent tethered lid(s) should notbe tightened until the cartridges are ready for final disposal.See page 23 for sample labeling.NOTE: Once the tethered cap is installed it cannot be removed. Measure cup: Using the provided measuring cup, fill cup with water whereindicated and pour into the solidʼs cartridge two times for a total of one liter. Gently swirl solids cartridge to activate packet contents.Wait 2 minutes, then insert solids cartridge into the Cactus ®SMART SINK ®. IMPORTANT!Once inserted, the cartridges will be self cancelling and cannotbe reused or reinserted. Do not remove a cartridge and attempt toreinsert the same cartridge since this may damage the unit.Insert one solid cartridge on the left side and one liquid cartridge on theright side of the Cactus®SMART SINK ®. The cartridges will onlyfit in the Cactus ®SMART SINK ®cabinet in one direction (facing forward).Each cartridge will only fit in its appropriate slot. The cartridge tethered lid will fitinto a lid storage compartment behind the cartridgeʼs housing. Be careful not topress down or pull up on the cartridges after you hear it click in place. Once it"clicks," the cartridge's cancellation feature is active, and if removed, the car-tridge cannot be replaced into the housing. This will result in wasting a cartridge.Align and fit lid on top of unit by pressing down firmly until it clicks in place onboth sides. Green lights will activate on both sides for twenty seconds.Attach the Cactus ®SMART SINK ®system onto the mounting bracket byaligning the bracket guides to the bottom of the unit and push unitforward until locked. Confirm it is secured by pulling the unit forward.It is important the Cactus ®SMART SINK ®be attached to the bolted mountingbracket in order to secure the unit from unauthorized removal. Once theCactus®SMART SINK ®cabinet is attached to the mounting bracket, onlyauthorized personnel can access the internal components, or remove the unit,with a security key.Review your facilityʼs drug disposal protocol with your pharmacy directorand safety personnel to provide clarity to the categories of waste that canbe disposed of in the Cactus ®SMART SINK ®. Utilize appropriate labeling for your system and cartridges. Train all related staff members byvisiting us online at www.CACTUSLLC.net and request an “inservice”, orby calling Cactus LLC.See “Company Contact Information” on back cover.The Cactus ®SMART SINK ®system is now ready for use. 7. 8. 9. 10. 11. EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ®LLC.net Bracket Installation The Cactus®SMART SINK ®security bracket isdesigned to lock the Cactus ®SMART SINK ®inplace and prevent the removal of the unit byunauthorized personnel. Once installed, there is noneed to remove the Cactus ®SMART SINK ®fromthe bracket unless you need to access the timerswitch or audible alarm settings or to replace the battery. WALL MOUNT INSTALLATION:Ensure there are no electrical, plumbing or gas lines located in thewall behind the wall where the unit will be mounted. Consult with your facilityengineering department to verify locations prior to mounting the bracket.CAUTION: Penetration of electrical, gas or plumbing lines can causesevere damage or personal injury.We recommend mounting the Cactus ®SMART SINK ®bracket to studs or fram-ing located behind the drywall; however, the Cactus ®SMART SINK ®can bemounted to drywall if the proper sheetrock screws are used (butterfly bolts orstrong drywall anchors). The bracket weight capacity is approximately 40 pounds. Identify the exact location for the wall mount, check the level of the bracket witha level device, and mark the hole locations with a marker using the providedtemplate. Drill pilot holes for the appropriate drywall anchors, screws, or butterflybolts. Attach the bracket to the wall with the appropriate bolts or screws. Regu-lar wood screws can be used for mounting into studs, solid walls, or countertops.Drywall anchors or butterfly bolts must be used for drywall installation. IMPORTANT!The Cactus ®SMART SINK ®bracket is designed to hold a maximum of 40pounds, but it must be securely and properly affixed to the wall with theappropriate mounting screws or anchors. Ideal height is 32 to 40 inches from the floor to the bottom of the bracket. • Included hardware: wood screws for mounting to solid walls or studs.• Drywall anchor fastener for mounting to raw drywall with no wall studs.• Self-tapping metal screws are included for walls with metal studs.• Bracket mounting template. - Page 13 - EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ®LLC.net FOR COUNTER TOP INSTALLATION:Use short wood screws (1") included for counter top mounting.To allow for adequate clearance for top removal and cartridge replacement,it is important to test the location by putting the Cactus®SMART SINK ®in place.Once you have verified there is adequate clearance, mark the location of the fourholes with a marker and drill small pilot holes for the screws.Place bracket in place over the holes and screw down with the one inchscrews provided.Once mounted on the bracket the Cactus ®SMART SINK ®can only be removedby depressing the “bracket release” button on the inside back of the unit(the button is located between the two locking cap storage compartments).The bracket release button can only be accessed with the security key andby removing the top of the unit. IMPORTANT!The alarm will sound when the top is unlocked and removed,and can be silenced only by replacing the top. - Page 14 - EQUIP# DSS04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 801 Church Lane • Easton, PA 18040, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com © Follett Corporation Form #3220 FZR Series -20 C (-4 F) undercounter freezers FZR5 – Freestanding or built-in below standard 36" (915mm) high counters. 4.2 cu ft (.12cu m) useable storage FZR4-ADA – Freestanding or built-in below 34" (864mm) high ADA-compatible counters, 3.5 cu ft (.10 cu m) useable storage New! Medical-grade -20 C (-4 F) undercounter freezers with external temperature display. Provide secure, stable-temperature storage for patient-fl oor, lab, pharmacy and mother’s milk applications. Stainless steel interior/exterior. ______________________________________________________ Delivers consistent temperatures and product security • Factory set to deliver -25 C (-13 F) to -23 C (-10 F) temperature range; set point adjustable -30 C (-22 F) to -15 C (5 F) • Factory set in °C (controller programming key included to change to °F) • Heavy-duty 1/3 HP compressor, forced-air cooling, digital microprocessor controller and thermal expansion valve (TXV) provide stable temperature, quick temperature pull down and rapid recovery following door openings and defrost cycles • Temperature-terminated automatic defrost ensures product remains below 20 C (-4 F) during defrost • Digital microprocessor controller incorporates defrost control, eliminating need for external, mechanical timer • Positive, locking door latch and magnetic gasket provides secure closure and product security • Supports JCAHO standards Saves staff time, provides exceptional fl exibility • External digital temperature display in user-selectable ˚C or ˚F provides easy logging without opening door • Automatic defrost cycle frees staff from manual defrost • Adjustable temperature range up to -15 C (5 F) accommodates nourishment applications • Field-reversible stainless door provides location fl exibility • Dished fl oor contains spills, allows easy clean-up • Two epoxy-coated shelves adjust for varied product • Compatible with automatic medication dispensing systems Easy installation and outstanding service access • Front-breathing design requires no top or side clearance • Inset door swing allows positioning next to other equipment without interference • Nylon-padded leveling feet protect fl oors • Automatic condensate evaporation eliminates drain • Front panel removes easily to access condenser, controller and condensate pan • Removable evaporator cover allows complete access to evaporator, TXV, fan, heater and heater safety switch • Rear slide-out condensing unit provides complete access Industry’s best warranty • 2 yr parts and labor on entire freezer • 5 yr parts on compressor • Toll free factory technical assistance Accessories • Temperature alarm with immersible probe and ˚C/˚F display (item #00112185) • Additional shelf (2 shelves standard) (item #00159699) • Pyxis* compatible door bracket (item #00114702) • Omnicell* compatible door bracket (item #00158014) EQUIP# FZU01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 19.50" (495mm) 23.75" (604mm) 27.50" (699mm) 19.00" (483mm) 24.16" (614mm) 25.50" (648mm) 34.00" (864mm) 23.75" (604mm) 23.75" (604mm) 10.25" (261mm) 21.44" (545mm) 18.88" (480mm) 25.50" (648mm) 17.75" (451mm) 3.00" (77mm)21.00" (534mm) Front View FZR5 Top View all models Handle Detail all models Plug Detail all models NEMA 5-15 (261mm) (77mm)(32mm)1.25"3.00" 10.25" Side View FZR5 19.75" (502mm)34.00" (864mm) 4.00" (102mm) Front View FZR4-ADA Side View FZR4-ADA 23.75" (604mm) 21.00" (534mm) 10.25" (261mm) 31.25" (794mm) 3.00" (77mm)21.00" (534mm) 4.00" (102mm) 18.88 (480mm) 25.50" (648mm) 17.75" (451mm) 18.69" (475mm) 17.00" (432mm)31.25" (794mm) Approximate Shipping Weight 175 lbs (79kg) Electrical 115V, 60Hz, 1 ph, 8.0 amps, maximum fuse – 15 amps. Hospital-grade cord and plug provided. -20 C (-4 F) undercounter freezers FZR Series 801 Church Lane • Easton, PA 18040, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com © Follett Corporation Form #3220 06/07 New! * Pyxis® is a registered trademark of Cardinal Health in the United States and other countries. * Omnicell® is a registered trademark of Omnicell, Inc. in the United States. Follett reserves the right to change specifi cations at any time without obligation. Certifi cations may vary depending on country of origin. Patent(s) pending EQUIP# FZU01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# ICG01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# ICG01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# ICG01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# ICG01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# ICG01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. -)3:0+)8- 92=7@?E)E :=6D F4<:?892>D9:C6+! HHH 86962=E942C6 4@> "%' "%'&C@5F4E2E2)966E1=@32= &286 @7 % #2C49 86,;+:-9+817:165 *96"%'N:D@FC=6256CD9:A F=EC2D@F?5:>28:?8DJDE6>56D:8?65 7@C235@>:?2=G2D4F=2C@3DE6EC:4 8J?64@=@8J?6@?2E2=A65:2EC:4 FC@=@8JEC2?D4C2?:2=42C5:242?5 D>2==A2CED2AA=:42E:@?D "?9:-48+01:-+:;8- /13-+6;9:1+8+01:-+:;8-–GE’s :??@G2E:G6A2E6?E65>@56= 32D65 E649?@=@8JAC@G:56DG2DE 4@>AFE2E:@?2=A@H6C62D6@7 :>28:?8H@C<7=@H7=6I:3:=:EJ2?5 AC@5F4EFA8C256 23:=:EJ *96"%' 6I46=D:?E967@==@H:?82C62D >+-7:165)34)/- ;)31:?:D4C62E65 E9C@F89E96FD6@7)( 4@565 E649?:BF6D2?525G2?465 )6C:6D EC2?D5F46CD !)=):)is GE’s innovative E649?@=@8JE92E2==@HD2G:CEF2= C6D42?@?2C49:G65:>286D3J 2AA=J:?8>2?J@7E96D2>6D42? 4@?EC@=D2G2:=23=65FC:?8E96@C:8:?2= 6I2> 86,;+:1<1:?762EFC6DE@6?23=6 "%'FD6CDE@>2I:>:K6E96:C D42?AC@5F4E:G:EJ–:?4=F5:?8)42? DD:DE2?E2?5FE@>2E:4 %AE:>:K2E:@? 8/65641+9H:E9A@H6C 2DD:DE65 4@?EC@=A2?6=2CE:4F=2E:?8"2C> 2?5=:89EH6:89EEC2?D5F46CD 4@>3:?:?8E@>2<6@?6@7E96>@DE 6C8@?@>:4F=EC2D@F?5DJDE6>D 2G2:=23=6 -5-8)3"7-+1.1+):1659 14-591659)5, &-1/0: :>6?D:@?D8:G6?H:E97=@2E:?8 <6J3@2C5DE@H657@CEC2?DA@CE x 6:89E >> :?496D x -:5E9>>:? x 6AE9>> :? x -6:89E <8=3D 3-+:81+)36=-8 x ,@=E286 ,24@C ,24 x C6BF6?4JK x &@H6C@?DF>AE:@?>2I:>F>@7 !,H:E9A6C:A96C2=D 65963--91/5 x 4E:G6&C@36&@CED x ?E68C2E652E=62DE x ?E68C2E65, (#F=E:C:G6 x %? 3@2C5DE@C286@7E96C>2=AC:?E6C x ?E68C2E65DA62<6CDH:E9DF3 H@@76C7@CAC6>:F>D@F?5 x ?E68C2E65=@4<:?8>6492?:D>E92E AC@G:56DC@==:?8=@4<2?542DE6C DH:G6==@4< x ?E68C2E65423=6>2?286>6?E x C@?E2?5C62C92?5=6D x 2D:=JC6>@G23=62:C7:=E6CD $9-85:-8.)+- 7-8):68-?*6)8, x =@2E:?8<6J3@2C525;FDE23=6:? E9C665:>6?D:@?D x 6:89E x (@E2E:@? x IE6?D:@? x F== D:K65324<=:E2=A92?F>6C:4 <6J3@2C5 x C8@?@>:492C5<6J=2J@FE x ?E6C24E:G6324< =:89E:?8 x ?E68C2E65C64@C5:?8<6JD7@C C6>@E64@?EC@=@7FAE@A6C:A96C2= @C%#56G:46D x ?E68C2E6586=H2C>6C #6;+0"+8--5 x :?:89(6D@=FE:@?@=@C *@F49"D4C66? x ?E6C24E:G65J?2>:4D@7EH2C6>6?F x C:89E?6DD25;FDE>6?E x +D6C 4@?7:8FC23=6=2J@FE 651:68 x cc:89 (6D@=FE:@?" x "EC2?D=2E:@?:?56A6?56?E@7 4@?D@=6 x >> :?9@C:K@?E2= x qDH:G6= x @=5 5@H?2?5=@4<>6492?:D>7@C EC2?DA@CE2E:@? x C:89E?6DD4@?EC2DE25;FDE>6?E x (6D@=FE:@? . x @C:K@?E2=,6CE:42=G:6H:?82?8=6@7 q RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % "?9:-4<-8<1-= 7731+):1659 x 35@>:?2= x %3DE6EC:42= x J?64@=@8:42= x C62DE x )>2==&2CED x ,2D4F=2C&6C:A96C2= x *C2?D4C2?:2= x &65:2EC:42?5$6@?2E2= x #FD4F=@D<6=6E2= x +C@=@8:42= x 2C5:24 7-8):15/6,-9 x #@56 x # #@56 x @=@C=@H#@56# x IE6?565:6=5@7,:6H"%',:6H @AE:@? x &@H6C@AA=6C>28:?8& x &-@AA=6C x -@AA=6C x ,@=F>6#@56D x )E2E:4 x (62=*:>6@AE:@? x ?2E@>:42=# #@56 x @565@?EC2DE>28:?8@AE:@? x =2DE@8C2A9J@AE:@? "+)5515/-:06,9 x =64EC@?:4)64E@C x =64EC@?:4@?G6I x =64EC@?:4":?62C x #6492?:42=,@=F>6)H66A #8)59,;+-8#?7-9 x )64E@C&92D65CC2J x @?G6ICC2J x #:4C@4@?G6ICC2J x ":?62CCC2J x #2EC:ICC2J x ,@=F>6&C@36D x @?G6ICC2J x #:4C@4@?G6ICC2J x ":?62CCC2J x )A=:ECJDE2= "?9:-4":)5,)8, -):;8-9 x 5G2?465FD6C:?E6C7246H:E99:89 C6D@=FE:@? :?49"E@F49A2?6= x FE@>2E:4%AE:>:K2E:@? x C@DD.62> x )A64<=6(65F4E:@?>28:?8)( x :?6?8=6)E66C x @5652C>@?:4>28:?8 x ,:CEF2=@?G6I x &2E:6?E:?7@C>2E:@?52E232D6 x >286C49:G6@?:?E68C2E65 ,2?592C55C:G6 x 5G2?465 x (2H2E2?2=JD:D x (62= E:>62FE@>2E:4@AA=6C42=4D x %2=4D x 6E2=*C6?5:?8 x #F=E:86DE2E:@?2=2=4D x :AJDA=2D:22=4D x J?64@=@8:42=2=4D x ,2D4F=2C2=4D x +C@=@8:42=2=4D x (6?2=2=4D x 2C5:242=4D x ?):E6I42A23:=:EJ x %? 3@2C56=64EC@?:45@4F>6?E2E:@? -8170-8)37:1659 x ?E68C2E65@AE:@?D7@C x :8:E2=-E96C>2=AC:?E6C x ,G:56@C64@C56C x :8:E2=4@=@CE96C>2=AC:?E6C x :8:E2=4@=@CE96C>2=AC:?E6C x IE6C?2=+)AC:?E6C4@??64E:@? x , @FEAFE2G2:=23=67@C 4@>A2E:3=656G:46D x @@E)H:E49H:E9AC@8C2>>23=6 7F?4E:@?2=:EJ x @?D@=6&C@E64E:G6@G6C 1973)?6,-9 x ":G62?5)E@C65:DA=2J@C>2EF== D:K62?5DA=:ED4C66? 3@E9H E9F>3?2:=D @CDE:==2?5$ x (6G:6H>286@C>2EI2?5 E9F>3?2:=D @C)E:==2?5$ x ):>F=E2?6@FD2A23:=:EJ x @CC@DD.62>&- x @CC@DD.62>#@C& x # x C@DD.62> x (62= E:>6*C:A=6I#@56 @CC@DD.62>#@C &&- x )6=64E23=62=E6C?2E:?8#@56D x @CC@DD.62>&- x @CC@DD.62>#&&- x -@AE:@? x #F=E: :>286DA=:EBF25D4C66? x ":G62?5@C7C@K6? x @CC@DD.62>@C C@DD.62>#@C& x &-# x ?56A6?56?E:?6A=2J324< x *:>6=:?65:DA=2J x ?56A6?56?EF2=@C C@DD.62>&-:DA=2J x - x :DA=2J@C>2ED *@A@EE@>D6=64E23=67@C>2E ):56):56D6=64E23=67@C>2E x ,:CEF2=@?G6I 1973)?556:):165 x &2E:6?E$2>6:CDE"2DE2?5#:55=6 x &2E:6?E x =E6C?2E6&2E:6?E x 86)6I2?5:CE92E6 x @DA:E2=$2>6 2E67@C>2ED6=64E23=6 ##//##////## x *:>67@C>2ED6=64E23=6 9@FCD 9@FCD x 6DE2E:@?2=867C@> "#&* x &C@36$2>6 x #2A?2>6D x &C@36%C:6?E2E:@? x 6AE9)42=6#2C<6C x "2E6C2=)42=6#2C<6C x @42=0@?6#2C<6CD x >2866AE9 x 0@@>6AE9 x #@56 x 2:? x J?2>:4(2?86 x >28:?8C6BF6?4J x C2>6G6C28:?8 x C2J#2A x )( x # #@56 x 2:? x J?2>:4(2?86 x *:>6)42=6 x @AA=6C#@56 x 2:? x ?8=6 x )2>A=6,@=F>66AE92?5-:5E9 x -2==:=E6C x ,6=@4:EJ2?5@CC6BF6?4J)42=6 x )A64ECF>?G6CD:@? x *:>6)42=6 x &( x @AA=6CC6BF6?4J x @=@C=@H@AA=6C#@56 x ":?66?D:EJ x C2>6G6C28:?8 x &24<6E):K6 x @=@C)42=6EJA6D &@H6C:C64E:@?2=&2?5 )J>>6EC:42=,6=@4:EJ>28:?8 x @=@C,6=@4:EJ(2?862?5 2D6=:?6 x @=@C*9C6D9@=5#2C<6C RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % x @=@C2:? x & x )A64ECF>?G6CD:@? x @AA=6CC6BF6?4J x *FCG6 x 4@FDE:4C2>6(2E6 x $286>286$F>36CC2>6 $F>36C x @5J&2EE6C?#F=E:A=69F>2?2?5 2?:>2=EJA6D x AA=:42E:@?$2>6 x #62DFC6>6?E(6DF=ED x %A6C2E@C#6DD286 x :DA=2J654@FDE:4%FEAFE x *)*96C>2=?56I)@7E*:DDF6 x **96C>2=?56IC2?:2=@?6 x **96C>2=?56I@?6 x ##6492?:42=?56I x @7#2I:>F>&@H6C@FEAFE x :@ADJF:56":?62?50@?6 x 62CE(2E6 -5-8)3"?9:-4 )8)4-:-89 "?9:-4"-:;7 x &C6 AC@8C2>>23=62E68@C:6D x +D6C&C@8C2>>23=6&C6D6E 2A23:=:EJ x 24E@CJ672F=E&C6D6E2E2 x "2?8F286D?8=:D9C6?49 6C>2?)A2?:D9E2=:2?&@CEF8F6D6 (FDD:2?C66<)H65:D92?:D9 FE49:??:D9$@CH68:2? x %(6A@CE@C>2ED:?4=F5:?8*@<J@ +?:G %D2<2+?:G +)FC@A62?5 )+# x +D6C67:?65??@E2E:@?D x @5J&2EE6C?D x FDE@>:K65@>>6?E@>6 &@D:E:@? 6473-:-$9-8)5;)3 )<)13)*3-65*6)8, :086;/0-37 +D6C#2?F2=2?5)6CG:46#2?F2=2C6 :?4=F565@?H:E96249DJDE6> AC:?E65>2?F2=:D2G2:=23=6FA@? C6BF6DE -468?4)/- -468? x #@7$#6>@CJ x )6=64E23=6$)6BF6?467@C$ (6G:6H x &C@DA64E:G6$#2C< x #62DFC6>6?ED2=4F=2E:@?D ??@E2E:@?D@?$&=2J324< x )4C@==:?8E:>6=:?6>6>@CJ x F2=>286$:DA=2J x 'F25>286$:DA=2J x $2F862?5$>286 $F>36C:DA=2J x $(6G:6H"@@A x $(6G:6H)A665 4)/-":68)/- x %? 3@2C552E232D6@7A2E:6?E :?7@C>2E:@?7C@>A2DE6I2>D x )E@C286@C>2ED x %#–4@>AC6DD65 F?4@>AC6DD65D:?8=6 >F=E:7C2>6H:E9H:E9@FE(2H 2E2 x IA@CE &-#,#&2?5 ,7@C>2ED x )E@C2866G:46D x +)#6>@CJ)E:4<#E@ 7@C6IA@CE:?8:?5:G:5F2= :>286D4=:AD x (DE@C286# x ,DE@C286 ( x 2C5C:G6>286)E@C286 L x @>A2C6@=5:>286DH:E94FCC6?E 6I2> x (6=@25@72C49:G6552E2D6ED 655-+:1<1:? x E96C?6E?6EH@C<4@??64E:@? x -:C6=6DD"$@AE:@?2= x %# @AE:@?2= x ,6C:7J x &C:?E x )E@C6 x #@52=:EJ-@C<=:DE x )E@C286@>>:E>6?E x #@52=:EJ&6C7@C>65&C@465FC6 )E6A#&&) x #65:2I492?86 x %77?6EH@C<>@3:=6DE@C286 BF6F6 x 'F6CJ(6EC:6G6 x &F3=:4)(*6>A=2E6 x )ECF4EFC65(6A@CE:?8–4@>A2E:3=6 H:E9G2D4F=2C2?5%DE2?52C5 x ?):E6I42A23:=:EJ 0?91636/1+)357;: )5-37:165 x &9JD:@=@8:42=?AFE x 492??6= x & 492??6= x +. 492??6= x F2=( *C:886C x &C6 D6EE23=6(6=2J*:>6 x &C6 D6EE23=6&@D:E:@? x 5;FDE23=62:?@?EC@= x &C6 D6EE23=6&&@D:E:@? x 5;FDE23=6&2:?@?EC@= x &C6 D6EE23=6+.&@D:E:@? x 5;FDE23=6+.2:?@?EC@= x FE@>2E:462CE(2E6:DA=2J !-768:&81:-87:165 x %? 3@2C5C6A@CE:?8A24<286 2FE@>2E6DC6A@CEHC:E:?8 x @C>2EDG2C:@FD6I2>C6DF=ED:?E@2 C6A@CEDF:E23=67@CAC:?E:?8@C C6G:6H:?8@?2DE2?52C5& x I2>C6DF=ED:?4=F56A2E:6?E:?7@ 6I2>:?7@>62DFC6>6?ED 42=4F=2E:@?D:>286D2?54@>>6?ED )E2?52C5E6>A=2E6DAC@G:565 x FDE@>:K23=6E6>A=2E6D "+)5515/)8)4-:-89 x :DA=2J65>28:?86AE9–4> x #:?:>F>6AE9@7:6=5–4> 0@@>AC@3656A6?56?E x #2I:>F>6AE9@7:6=5– 4>AC@3656A6?56?E x @?E:?F@FDJ?2>:4(646:G6@4FD @?E:?F@FDJ?2>:4(646:G6 A6CEFC6 x 5;FDE23=6J?2>:4(2?86 x 5;FDE23=6:6=5@7,:6H%, x >286(6G6CD6(:89E"67E x >286(@E2E:@?@7M M 1/1:)36,- x 5;FDE23=6 x 4@FDE:4&@H6C x 2:? x J?2>:4(2?86 x C2>6G6C28:?8 x C2J)42=6#2A x C6BF6?4J x ":?66?D:EJ x )42??:?8):K6%,@C?8=6 56A6?5:?8@?E96AC@36D66AC@36 DA64:7:42E:@?D x @=@C:K2E:@? x (6;64E x )FAAC6DD:@? x )( 1/1:)36,- x 5;FDE23=6 x 4@FDE:4&@H6C x 2:? RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % x J?2>:4(2?86 x C2J)42=6#2A x C6BF6?4J x )H66A)A665 x #@=@C:K2E:@? x #:DA=2J@C>2E x (6;64E:@? 5):641+)36,- x # >@564FCD@C25;FDE23=62E2?J A=2?6 x 2?3624E:G2E657C@>2$=@@A 7C@>2=:G6@CDE@C65:>286 x #42A23:=:EJ x G2:=23=6H:E9@=@C=@H#@56 1/1:)3"7-+:8)3 6773-86,- x 5;FDE23=6 x 4@FDE:4&@H6C x 2:? x J?2>:4(2?86 x C2J)42=6#2A x *C2?D>:EC6BF6?4J x -2==:=E6C x &-@=@C:K2E:@? x ,6=@4:EJ)42=6(2?86 x )H66A)A665 x )2>A=6,@=F>6"6?8E9 x ?8=6@CC64E:@? x )E66C65":?62C x )A64ECF>?G6CD:@? x *C246#6E9@5 x 2D6=:?6)9:7E x @AA=6CFE@*C246 x *:>6(6D@=FE:@? x @>AC6DD:@? x *C246:C64E:@? x *C246)6?D:E:G:EJ 1/1:)3636836= 6,- x 5;FDE23=6 x 4@FDE:4&@H6C x @=@C#2AD:?4=F5:?8G6=@4:EJ G2C:2?46>2AD x 2:? x ,6=@4:EJ)42=6(2?86 x -2==:=E6C x &24<6E):K6 x ":?66?D:EJ x )A2E:2=:=E6C x )E66C:?8?8=6 x 2D6=:?6)9:7E x C2>6G6C286 x *9C6D9@=5 x 44F>F=2E:@?>@56 x )2>A=6,@=F>6@?EC@= x =2D9)FAAC6DD:@? 1/1:)36=-86773-8 4)/15/ x 5;FDE23=6 x 4@FDE:4&@H6C x @=@C#2AD:?4=F5:?8G6=@4:EJ G2C:2?46>2AD x 2:? x ,6=@4:EJ)42=6(2?86 x -2==:=E6C x &24<6E):K6 x ":?66?D:EJ x )A2E:2=:=E6C x )E66C:?8?8=6 x C2>6G6C286 x *9C6D9@=5 x 44F>F=2E:@?>@56 x )2>A=6,@=F>6@?EC@= x =2D9)FAAC6DD:@? 65:15;6;9&)<- 6773-87:165 x G2:=23=6@?#) ) &2?5 &AC@36D x )E66C23=6->@56:?4=F56D 5;FDE23=6 x 4@FDE:4&@H6C x 2:? x J?2>:4(2?86 x C2J)42=6#2A x *C2?D>:EC6BF6?4J x -2==:=E6C x -@=@C:K2E:@? x ,6=@4:EJ)42=6(2?86 x )H66A)A665 x ?8=6@CC64E:@? x )A64ECF>?G6CD:@? x *C246#6E9@5 x 2D6=:?6)9:7E x @AA=6CFE@*C246 x @>AC6DD:@? x *C246:C64E:@? x *C246)6?D:E:G:EJ ;:64):1+ 7:141@):165 x %AE:>:K6 #@56:>286E@:>AC@G6 4@?EC2DEC6D@=FE:@? x )6=64E23=62>@F?E@74@?EC2DE C6D@=FE:@?:>AC@G6>6?E=@H >65:F>9:89 x FE@ )A64EC2=%AE:>:K6–25;FDED 32D6=:?6:?G6CE&(@?=:G6:>286 2?52?8=64@CC64E:@? 6,-,)84651+ 4)/15/ x G2:=23=6@?2==2?5AC@36D 6I46AE#) 6,-,65:8)9: 4)/15/7:165 x G2:=23=6@?() " #" ( ()& ( #) x @?EC2DE*:>6CD x *:>65+A52E6D – D64@?5D x 44F>F=2E:@?>@56D6G6?=6G6=D x #2I:>F>?92?46#@56 x =2D9 x *:>6?E6?D:EJFCG6*?2=JD:D x *96"%':D56D:8?657@C 4@>A2E:3:=:EJH:E9>@DE4@>>6C4:2==J 2G2:=23=6F=EC2D@F?54@?EC2DE286?ED 642FD6E962G2:=23:=:EJ@7E96D6 286?ED:DDF3;64EE@8@G6C?>6?E C68F=2E:@?2?52AAC@G2=AC@5F4E 762EFC6D:?E6?5657@CFD6H:E9E96D6 286?ED>2J?@E364@>>6C4:2==J >2C<6E65?@C>2562G2:=23=6367@C6 E964@?EC2DE286?E:D4=62C657@CFD6 @?EC2DEC6=2E65AC@5F4E762EFC6D2C6 6?23=65@?=J@?DJDE6>D7@C56=:G6CJ E@2?2FE9@C:K654@F?ECJ@CC68:@?@7 FD6 %1-=7:165 x IE6?565:6=5@7,:6H>28:?8 x G2:=23=6@?E967@==@H:?8AC@36D " " #" " : ( # ( ( ( ($ ()& #) #) ) ) ) x @CFD6:? #@56 x C@DD.62>:D2G2:=23=6@?=:?62C AC@36D x FE@56E64E:@?@7D42?5:C64E:@? x &C6@CA@DE AC@46DDK@@> x (@E2E:@? x FE@36DE7:E@?>@?:E@C x #62DFC6>6?ED:? #@56 x ==@HDF?=:>:E65C@E2E:@?2?5 A=2?2CEC2?D=2E:@?D x C64@?DECF4E:@?7C@>$DH66A ,<)5+-, x 4BF:D:E:@?@7@=@C52E2 RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % x FE@>2E:4C6?56C:?8 x "2?5D42A6E649?@=@8J x #@G:6 !-)3#14-7:165 x 4BF:D:E:@?#@56D x (62=*:>6 x )E2E:4 x ,:DF2=:K2E:@?#@56D x (6?56C:?85:G6CD6DFC7246 2?5:?E6?D:EJAC@;64E:@?>@56D x )64E:@?2=&=2?6D)64E:@? A=2?6DA6CA6?5:4F=2CE@6249 @E96C x ,@=F>6@?EC2DE>28:?8 )E2E:4 @AE:@?2= x *@>@8C2A9:4+=EC2D@F?5 >28:?8@AE:@?2= x (6?56C#@56 x )FC7246*6IEFC6)FC7246 )>@@E9>2I >:? 2?5. C2J 2G6C286:?E6?D:EJAC@;64E:@?>:I >@56@7EH@C6?56C>@56D x FCG65A@:?E(6?56CDE2CE x #@G:6 x )42=A6=FEE@@= x :DA=2J@C>2E x 'F25 &=2?6 x F2= &=2?6 x ):?8=6@C @C @C &=2?6 x FE@>2E65,@=F>62=4F=2E:@? ,%"@AE:@?2= x 6E2G:6H %63;4-)<1/):165 7:165 x G2:=23=6@?E96 ) " #" ( ) 2?5" : #)AC@36D x )6?D@C 32D6524BF:D:E:@? x &@D:E:@?#2C<6CD x $665=6E:AEC24<:?8 x ,:CEF2=EC24<:?8 x *CF762EFC6:?4=F56D x :DA=2J@752E2:?#2:? &2C2==6= ?8F=2C #@56 x (6?56C#@56DC2J)FC7246 *6IEFC6#:? #2I G6C286 ?E6?D:EJ x #62DFC6>6?ED5:DE2?462?8=6 2C62G@=F>6 x #@G:6 "+)59919:)5:7:165 x 24E@CJ&C@8C2>D x +D6C–567:?65AC@8C2>D x )E6AD:?4=F56:>2862??@E2E:@?D >@56EC2?D:E:@?D32D:4:>28:?8 4@?EC@=D2?5>62DFC6>6?E:?:E:2E:@? 3)9:6/8)70?7:165 x G2:=23=6@?#" " 2?5 AC@36D 3)9:6/8)70? ;)5:1.1+):1657:165 –56:)<)13)*3-15:0- $51:-,":):-9 x (6=2E:G6BF2?E:7:42E:@?E@@= x G2:=23=6@?#" " EC2?D5F46CD ;)5:1:):1<-36= 5)3?9197:165 x G2:=23=6:?@=@C2?5&@H6C @AA=6C #%7:165 x #J@42C5:2=@AA=6C>28:?8H:E9 4@=@C@G6C=2J@?E:DDF6:>286 x G2:=23=6@?E96D64E@CAC@36D x *:DDF64@=@C@G6C=2J42?36 C6>@G65E@D9@H;FDEE96:>286 DE:==C6E2:?:?8E96E:DDF6G6=@4:EJ :?7@C>2E:@? x FCG65?2E@>:42=# >@567C66 4FCG655C2H:?8@7# >@56 86?6C2E657C@>E964FCD@C :?56A6?56?E7C@>E962I:2=A=2?6 x ' ?2=JD:D#F=E:A=6*:>6 #@E:@? EC2465:DA=2J7C@>D6=64E65A@:?ED:? E96>J@42C5:F> ":8-99+067:165 x 5G2?4652?57=6I:3=6DEC6DD649@ 6I2>:?2E:@?42A23:=:E:6D x &C@G:56D6I6C4:D62?5 A92C>24@=@8:42=AC@E@4@=E6>A=2E6D x 5672F=EE6>A=2E6D x *6>A=2E665:E@C7@CFD6C 4@?7:8FC2E:@?@76I:DE:?8E6>A=2E6D@C 4C62E:@?@7?6HE6>A=2E6D x (676C6?46D42?5:DA=2J5FC:?8 24BF:D:E:@?7@CDEC6DD=6G6= 4@>A2C:D@?5F2=D4C66? x 2D6=:?6=6G6=&C6G:@FD=6G6= D6=64E23=6 x (2H52E24@?E:?F@FD42AEFC6 x %G6C D642G2:=23=6 x -2==>@E:@?D4@C:?83F==D 6J62?5 D68>6?E2= x )>2CEDEC6DDFE@>2E:42==JD6EFA G2C:@FDD42??:?8A2C2>6E6CD6 8 86@>6ECJ7C6BF6?4J82:?244@C5:?8 E@D2>6AC@;64E:@?@?AC6G:@FD=6G6= %18:;)365<-> x &C@G:56D24@?G6I7:6=5@7G:6H x @>A2E:3=6H:E9C@DD.62> x G2:=23=6@?2===:?62C2?5D64E@C EC2?D5F46CD" " #" " : ()& #) #) ) ) ) *4 "! x )A64<=6(65F4E:@?>28:?8 x &C@G:56D>F=E:A=6=6G6=D@7DA64<=6 C65F4E:@? x @>A2E:3=6H:E9):563J):56 F2=,:6H:DA=2J x @>A2E:3=6H:E9""=:?62C4@?G6I 2?5D64E@CEC2?D5F46CD x @>A2E:3=6H #@56@=@C @?EC2DE86?E2?5:>28:?8 8699'-)4 x &C@G:56D@C2?8=6D@7DA2E:2= 4@>A@F?5:?8 x ":G6):563J):56F2=,:6H:DA=2J x @>A2E:3=6H:E9 x @=@C#@56 x &- x )( x @5652C>@?:4>28:?8 x ,:CEF2=@?G6I x G2:=23=6@?E967@==@H:?8AC@36D " " #" " : ( # ( ( ( ($ ()& 65:8639<)13)*3- While “Live” x -C:E60@@> x #C@DD.62> #@56 x 2:? x * x J?2>:4(2?86 x 4@FDE:4%FEAFE x *C2?D>:DD:@?@4FD&@D:E:@? x *C2?D>:DD:@?@4FD$F>36C x ":?66?D:EJ@?EC@= x )H66A)A6657@C# #@56 RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % x $F>36C@7?8=6D7@C C@DD.62> x &- #@56 x 2:? x J?2>:4(2?86 x 4@FDE:4%FEAFE x *C2?D>:DD:@?C6BF6?4J x &( x -2==:=E6C x )A64EC2=G6C28:?8 x )2>A=6,@=F>62E6 x "6?8E9 x 6AE9 x ,6=@4:EJ)42=6 x @=@C=@H#@56 x #2:? x #,6=@4:EJ(2?86 x 4@FDE:4%FEAFE x -2==49@:=E6C x &24<6E):K6 x C2>6(2E6@?EC@= x #)A2E:2=:=E6C x #C2>6G6C28:?8 x #":?6(6D@=FE:@? x C6BF6?4J,6=@4:EJ2D6":?6 )9:7E 65:8639<)13)*3-65 “Freeze” or Recall x FE@>2E:4%AE:>:K2E:@? x )( x C@DD.62>–:DA=2J?@? 4@>A@F?5652?54@>A@F?565 :>286D:>F=E2?6@FD=J:?DA=:ED4C66? x C64@?DECF4E:@?7C@>2DE@C65 $=@@A x #C@DD.62>#@56 x C2J#2A%AE:>:K2E:@? x * x @=@C:K652?5# x C2>6G6C286=@@AD@?=J x J?2>:4(2?86 x ?2E@>:42=##@56 x #2I(6250@@>E@I x 2D6":?6)9:7E x )H66A)A665 x &-#@56 x C2J#2A x &@DE2:? x 2D6=:?6D9:7E x )H66A)A665 x ?G6CE)A64EC2=H2G67@C> x @>AC6DD:@? x (6;64E:@? x @=@C:K65)A64ECF> x :DA=2J@C>2E x @AA=6CF5:@ x ?8=6@CC64E x 'F:4<?8=6@CC64E x FE@?8=6@CC64E x @=@C=@H x %G6C2==2:?=@@AD2?5DE:==D x @=@C#2A x *C2?DA2C6?4J#2A x C2>6G6C28:?8=@@AD@?=J x =2D9)FAAC6DD:@? x #:DA=2J*9C6D9@=5 x )A64EC2=?G6CE7@C@=@C@AA=6C x ?2E@>:42=# #@56@?4:?6=@@A x x C2J#2A@=@C:K6 x &@DE2:? x 92?865:DA=2J–D:?8=65F2= BF25D64E:@?2=@CC6?56C65 -)9;8-4-5:9 )3+;3):1659 -5-8)36,- x 6AE9:DE2?46 x :C4F>76C6?46==:AD6*C246 x C62==:AD6*C246 x ,@=F>6==:AD@:5 x )E6?@D:DC62@C:2>6E6C x ?8=636EH66?EH@=:?6D x F2= >@5642A23:=:EJ -5-8)36,- x # 6AE9 x :DE2?46 x *:>6 x )=@A6 x 62CE(2E6 -5-8)36773-8 -)9;8-4-5:9 )3+;3):1659 x ,6=@4:EJ x *:>6 x (2E:@,6=@4:E:6DC6BF6?4J (2E:@ x &)&62<)JDE@=6 x ?5:2DE@=6 x &)&)(2E:@ x &)&)(2E:@ x *446=6C2E:@?*:>6 x "446=6C2E:@? x *#.*:>6G6C2865#2I:>F> ,6=@4:EJ x ,@=F>6=@H*#$2?5,6DD6= C62 x 62CE(2E6 x &&F=D2E:=:EJ?56I x ((6D:DE:G:EJ?56I !-)3:14-6773-8;:6 -)9;8-4-5:9 )3+;3):1659 x &)&62<)JDE@=6 x ?5:2DE@=6 x ##:?:>F>:2DE@=6 x &&F=D2E:=:EJ?56I x ((6D:DE:G:EJ?56I x *446=6C2E:@?*:>6 x 446=6C2E:@? x &)&)(2E:@ x &)&)(2E:@ x (62CE(2E6 x *#.*:>6G6C2865#2I:>F> ,6=@4:EJ x &,"&62<,6=@4:EJ,2=F6 x ,@=F>6=@H*#$2?5,6DD6= C62 -)9;8-4-5:9 )3+;3):1659 x 6DE2E:@?2=863J )6DE2E:@?2=)24 ("C@H?(F>A"6?8E9 "6>FC"6?8E9 &:A2C:6E2=:2>6E6C 35@>:?2=:C4F>76C6?46 625:C4F>76C6?46 &*I**?E6C:@C&@DE6C:@C *CF?<:2>6E6C3J*C2?DG6CD6 *CF?<:2>6E6C *6E2=*CF?<C@DD D64E:@?2= C62 "F>6CFD"6?8E9 :?@4F=2C:DE2?46 *@@E"6?8E9 %%44:A:E2=C@?E2=:2>6E6C **C2?DG6CD635@>:?2= :2>6E6C **C2?DG6CD66C636==F> :2>6E6C **9@C2I*C2?DG6CD6 :2>6E6C **:3:2"6?8E9 +"$+=?2"6?8E9 x DE:>2E656E2=-6:89E-3J & &" &" " " &&***" &&***)" x 2=4F=2E:@?D2?5(2E:@D "& " RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % " 6A92=:4?56I >?:@E:4=F:5?56I *(2C5:@ *9@C24:4C62(2E:@ x #62DFC6>6?ED2=4F=2E:@?D3J )+#)+# 6C<@H:EK 6CE28?@=:C6??6C2>A36== 9:EEJ:< $6DC:4<D6?@=5DE6:? 25=@4<2?D>2??6==>2?:== @9=6C 62?EJ )+#!FCEK#2J56? #6C46C#6CK#@@C6$6=D@?%D2<2 +?:G6CD:EJ&2C:D(6>A6?(@3:?D@? )96A2C5)96A2C5-2CD@77*@<J@ +?:G6CD:EJ*@<J@)9:?@KF<2/2C<@?: x 6E2=C2A9:42=*C6?5:?8 x C@HE9&6C46?E:=6D x #F=E: 6DE2E:@?2=2=4F=2E:@?D x 6E2='F2=:E2E:G66D4C:AE:@? ?2E@>:42=DFCG6J x 6E2=?G:C@?>6?E2=6D4C:AE:@? :@A9JD:42=AC@7:=6 x &C@8C2>>23=6%*23=6D x %G6CD6=64E23=6%2=4D x IA2?565-@C<D966ED (-)9;8-4-5:9 )3+;3):1659 x (:89E%G2CJ"6?8E9-:5E96:89E x "67E%G2CJ"6?8E9-:5E96:89E x +E6CFD"6?8E9-:5E96:89E x 6CG:I"6?8E9*C246 x %G2C:2?,@=F>6 x $%?5@>6EC:2=E9:4<?6DD x %G2C:2?( x +E6C:?6( x @==:4F=2C>62DFC6>6?ED x )F>>2CJ(6A@CED %)9+;3)8 -)9;8-4-5:9 )3+;3):1659 x )/))JDE@=:4:DE2=@>>@? 2C@E:5CE6CJ x ):2DE@=:4:DE2= @>>@?2C@E:5CE6CJ x )/)#)JDE@=:4#:5@>>@? 2C@E:5CE6CJ x )#:2DE@=:4#:5@>>@? 2C@E:5CE6CJ x )/)&)JDE@=:4&C@I:>2= @>>@?2C@E:5CE6CJ x )&:2DE@=:4&C@I:>2= @>>@?2C@E:5CE6CJ x )/))JDE@=:4:DE2=?E6C?2= 2C@E:5CE6CJ x ))JDE@=:4:DE2=?E6C?2= 2C@E:5CE6CJ x )/)#)JDE@=:4#:5?E6C?2= 2C@E:5CE6CJ x )#:2DE@=:4#:5?E6C?2= 2C@E:5CE6CJ x )/)&)JDE@=:4&C@I:>2=?E6C?2= 2C@E:5CE6CJ x )&:2DE@=:4&C@I:>2= ?E6C?2=2C@E:5CE6CJ x )/))JDE@=:4:DE2=IE6C?2= 2C@E:5CE6CJ x ):2DE@=:4:DE2=IE6C?2= 2C@E:5CE6CJ x )/)&)JDE@=:4&C@I:>2=IE6C?2= 2C@E:5CE6CJ x )&:2DE@=:4&C@I:>2= IE6C?2=2C@E:5CE6CJ x ,(*)JDE@=:4,6CE63C2=,6=@4:EJ x )+",)JDE@=:4)F34=2G:2? ,6=@4:EJ x FE@>2E:4#* x )F>>2CJ(6A@CED $8636/1+)3)3+9 x =2556C,@=F>6 x &C@DE2E6,@=F>6 x "E(E(6?2=,@=F>6 x 6?6C:4,@=F>6 x &@DE ,@:5=2556C,@=F>6 &C@36D==%AE:@?2= !#:4C@ 4@?G6I:@ADJ&C@36 x AA=:42E:@?D35@>6? x :@ADJF:56):?8=6 ?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E"( @?G6I&C@36 x AA=:42E:@?D35@>6?%/$ +C@=@8J x :@ADJF:56#F=E: ?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E" #2EC:ICC2J@?G6I&C@36 x AA=:42E:@?D35@>6?%/$ &65:2EC:4D x :@ADJF:56#F=E: 2?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E( #:4C@ 4@?G6I&C@36 x AA=:42E:@?D%/$+C@=@8:42= x :@ADJF:56):?8=6?8=6 :DA@D23=6H:E925:DA@D23=6 3C24<6E# @CC6FD23=6 3C24<6E "$ ")64E@C&C@36 x AA=:42E:@?D35@>6?%/$ x :@ADJF:56#F=E: 2?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E) ")64E@C&C@36 x AA=:42E:@?D&65:2EC:4D$6@?2E2= ")64E@C&C@36 x AA=:42E:@?D* ")64E@C&C@36 x AA=:42E:@?D2C5:24* ")64E@C&C@36 x AA=:42E:@?D&65:2EC:42C5:24 &65:2EC:435@>6? ":?62C&C@36 x AA=:42E:@?D,2D4F=2C)>2== &2CED&65:2EC:435@>6? x :@ADJF:56#F=E: 2?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E! ":?62C&C@36 x AA=:42E:@?D,2D4F=2C)>2== &2CED35@>6? x :@ADJF:56G2:=23=6#F=E: ?8=65:DA@D23=6H:E92C6FD23=6 3C24<6E" #2EC:ICC2J":?62C&C@36 x AA=:42E:@?D)>2==&2CED ,2D4F=2C$6@?2E2=&65:2EC:4D x :@ADJF:56G2:=23=6#F=E: ?8=65:DA@D23=6H:E92C6FD23=6 3C24<6E"! 1":?62C&C@36 x AA=:42E:@?D)>2==&2CED ,2D4F=2C?EC2@A6C2E:G6 ! @?G6I,@=F>6&C@36 x AA=:42E:@?D35@>6?%/$ x :@ADJF:56):?8=6?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E D:?8=62?8=6 C6FD23=6 / !@?G6I,@=F>6&C@36 x AA=:42E:@?D35@>6?%/$ &65:2EC:4D x :@ADJF:56):?8=6?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E D:?8=62?8=6 C6FD23=6 / RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % !@?G6I,@=F>6&C@36 x AA=:42E:@?D%/$+C@=@8J x :@ADJF:56):?8=6?8=6 (6FD23=6 ( !@?G6I,@=F>6&C@36 x AA=:42E:@?D$6@?2E2=&65:2EC:4D x :@ADJF:56):?8=6?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E D:?8=62?8=6 C6FD23=6 !" ":?62C,@=F>6&C@36 x AA=:42E:@?D)>2==&2CED ,2D4F=2C&65:2EC:4D x :@ADJF:56):?8=6?8=6 5:DA@D23=6H:E92C6FD23=6 3C24<6E D:?8=62?8=6 C6FD23=6 - -)A=:ECJDE2=&C@36 AA=:42E:@?D2C5:24,2D4F=2C -)A=:ECJDE2=&C@36 AA=:42E:@?D2C5:24,2D4F=2C #+*C2?D 6D@A92862=&C@36 AA=:42E:@?D2C5:24 >:-85)357;:9)5, ;:7;:956:15+3;,15/65 *6)8,7-8170-8)39 x , x F5:@)E6C6@%FE x E96C?6E x #F=E:A=6+) A@CED )276EJ@?7@C>2?46 #0- 19 • Classified to UL 60601 3J2 $2E:@?2==J(64@8?:K65*6DE"23 • Certified to CAN/CSA $@ #3J2?)244C65:E65*6DE "23 x #2C<65E@@F?4:=:C64E:G6 @?#65:42=6G:46D x @?7@C>DE@E967@==@H:?8 DE2?52C5D7@CD276EJ x $ #65:42=6=64EC:42= 6BF:A>6?E–&2CE 6?6C2= C6BF:C6>6?ED7@CD276EJ x $ #65:42=6=64EC:42= 6BF:A>6?E–&2CE 6?6C2= C6BF:C6>6?ED7@CD276EJ– @==2E6C2=)E2?52C5)276EJ C6BF:C6>6?ED7@C>65:42= 6=64EC:42=DJDE6>D x $ #65:2=6=64EC:42= 6BF:A>6?E–&2CE 6?6C2= C6BF:C6>6?ED7@CD276EJ– @==2E6C2=)E2?52C5 =64EC@>28?6E:44@>A2E:3:=:EJ– C6BF:C6>6?ED2?5E6DED x $ #65:42=6=64EC:42= 6BF:A>6?E&2CE 6?6C2= C6BF:C6>6?ED7@CD276EJ– @==2E6C2=)E2?52C5 AC@8C2>>23=66=64EC:42=>65:42= DJDE6>D x $#65:42=6G:46D– AA=:42E:@?@7+D23:=:EJ ?8:?66C:?8E@#65:42=6G:46D x $ #65:42=6=64EC:42= 6BF:A>6?E–&2CE &2CE:4F=2C C6BF:C6>6?ED7@CE96D276EJ@7 F=EC2D@?:4>65:42=5:28?@DE:42?5 >@?:E@C:?86BF:A>6?E x )% :@=@8:42=6G2=F2E:@? @7>65:42=56G:46D–&2CE G2=F2E:@?2?5E6DE:?8 x $#+4@FDE:4@FEAFE >62DFC6>6?EDE2?52C57@C 5:28?@DE:4F=EC2D@F?56BF:A>6?E x $#+)E2?52C57@CC62=E:>6 5:DA=2J@7E96C>2=2?5 >6492?:42=24@FDE:4@FEAFE :?5:46D@?5:28?@DE:4F=EC2D@F?5 6BF:A>6?E#*)** x #>:DD:@?DC@FA =2DD 56G:46C6BF:C6>6?ED2DA6C)F3 4=2FD6 @7)&( RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286@7 % ";773-4-5: )8,1)+ -)9;8-4-5:9)3+;3):1659 6,--)9;8-4-5:9 • @CE2 - @CE:4(@@E:2>6E6C@(@@E :2> - @CE:4C49:2>6E6C@C49 :2> - D46?5:?8@CE:4:2>6E6C@D4 - 6D46?5:?8@CE:4:2>6E6C@ 6D4:2> - @CE2DE9>FD@DE9>FD - @CE2@DE;F?4E • @CE:4,2=G6 - @CE:4,2=G6FDA)6A2C2E:@?, FDA - @CE:4,2=G6C62&=2?:>6ECJ, &=2?:>6ECJ - *C2?D, • "67EEC:F> - "67EEC:F>:2>6E6C":2> - ""6?8E9"#2;@C - "-:5E9"#:?@C - "67EEC:F>:2>6E6CE@@(@@E :2>6E6C(2E:@"@(2E:@ - "67EEC:F>C62"5"D - "67EEC:F>,@=F>6):?8=6&=2?6 #6E9@5@7:D<","), ","), • "67E,6?EC:4=6 - "67E,6?EC:4=6#2DD",&-5 ",&-D - "67E,6?EC:4=6,@=F>6 *6:499@=KF3:4",5",D - "67E,6?EC:4=6?E6C?2=:2>6E6C ",5",D - "67E,6?EC:4=6"6?8E9","5","D - "67E,6?EC:4=6%FE7=@H*C24E :2>6E6C",%*:2> - "67E,6?EC:4=6&@DE6C:@C-2== *9:4<?6DD",&-5",&-D - "67E,6?EC:4=6"6?8E9",#2;@C - "67E,6?EC:4=6-:5E9",#:?@C - "67E,6?EC:4=6%FE7=@H*C24EC62 ",%* - "67E,6?EC:4=6C62*H@ 92>36C@FC92>36C)9@CE I:D",5",D - "67E,6?EC:4=6?5@42C5:2=C62 -:5E9",5",D - "67E,6?EC:4=6A:42C5:2=C62 "6?8E9",6A:5",6A:D - "67E,6?EC:4=6#2DD?56I",&-5 ",&-D - ;64E:@?C24E:@?*6:499@=KF36 ",5",D - "67E,6?EC:4=6&@DE6C:@C-2== C24E:@?2=)9@CE6?:?8",&-5 ",&-D - "67E,6?EC:4=6)EC@<6?56I *6:499@=KF36",5",D2?5 @5J)FC7246C62 - "67E,6?EC:4=6C24E:@?2= )9@CE6?:?8",5",D - "67E,6?EC:4=6)EC@<6,@=F>6 *6:499@=KF3:4",5",D - "67E,6?EC:4=6)EC@<6?56I):?8=6 &=2?6*H@92>36C#6E9@5@7 :D<",5",D",)5",)D - "67E,6?EC:4=6)EC@<6?56I):?8=6 &=2?6@FC92>36C#6E9@5@7 :D<",5",D",)5",)D - "67E,6?EC:4=6)EC@<6?56I: &=2?6F==6E#6E9@5@7:D<",5 ",D - ?E6CG6?EC:4F=2C)6AEF>,) - "67E,6?EC:4=6?E6C?2=:2>6E6C ", - "67E,6?EC:4=6&@DE6C:@C-2== *9:4<?6DD",&- • #:EC2=,2=G6 - #:EC2=,2=G6??F=FD:2>6E6C#, ??:2> - &@:?E E@ )6AEF>)6A2C2E:@? &)) - #:EC2=,2=G6C62&=2?:>6ECJ#, &=2?:>6ECJ • &F=>@?:4,2=G6 - &F=>@?:4,2=G6C62&, &=2?:>6ECJ - &F=>@?:4,2=G6??F=FD:2>6E6C &,??F=FD:2> - &F=>@?:4:2>6E6C&F=>@?:4 :2> • (:89EEC:F> - (:89EEC:F>:2>6E6C"6?8E9 (#2 - (:89EEC:F>:2>6E6C-:5E9( #: - (:89EEC:F>C62( - (:89EEC:F>,@=F>6):?8=6&=2?6 #6E9@5@7:D<(5 - (:89EEC:F>,@=F>6)JDE@=:4 ):?8=6&=2?6#6E9@5@7:D<(D • (:89E,6?EC:4=6 - (:89E,6?EC:4=6%FE7=@H*C24EC62 (,%*&=2?:>6ECJ - "67E&F=>@?2CJCE6CJC62"& C62 - (:89E&F=>@?2CJCE6CJC62(& C62 - (:89E,6?EC:4=6?E6C?2=:2>6E6C (,5(,D - (:89E,6?EC:4=6:2>6E6C"6?8E9 (,#2 - (:89E,6?EC:4=6:2>6E6C-:5E9 (,#: - (:89E,6?EC:4=6-2==*9:4<?6DD (,-5(,-D - (:89E,6?EC:4=6%FE7=@H*C24E :2>6E6C(,%*:2> - "67E&F=>@?2CJCE6CJ"& - #2:?&F=>@?2CJCE6CJ#& - (:89E&F=>@?2CJCE6CJ(& • )JDE6> - ?76C:@C,6?22G2 - )JDE6>:4,6:?:2>6E6C)JDE6>:4 :2> - &2E6?EF4EFDCE6C@D:D:2>6E6C &:2> - &6C:42C577FD:@?&D - &2E6?E@C2>6?%G2=6:2>6E6C &%:2> - ,6?EC:4F=2C)6AE2=6764E:2>6E6C ,):2> - ?E6CG6?EC:4F=2C)6AEF>,) C24E:@?2=)9@CE6?:?8,)5,)D • *C:4FDA:5,2=G6 - *C:4FDA:5,2=G6C62*, &2?:>6ECJ - *C:4FDA:5,2=G6??F=FD:2>6E6C *, - ??F=FD:2> 6,--)9;8-4-5:9 • @CE2 - @CE:4(@@E:2>6E6C@(@@E :2> • @CE:4,2=G6 - @CE:4,2=G6:2>6E6C,:2> - @CE:4,2=G6FDA)6A2C2E:@?, FDA - @CE:4,2=G6;64E:@?*:>6",* • "67EEC:F> - "67EEC:F>:2>6E6CE@@(@@E :2>6E6C(2E:@"@(2E:@ - "67EEC:F>:2>6E6C":2> • "67E,6?EC:4=6 - "67E,6?EC:4=6,@=F>6 *6:499@=KF3:4",5",D - "67E,6?EC:4=6?E6C?2=:2>6E6C ",5",D - "67E,6?EC:4=6&@DE6C:@C-2== *9:4<?6DD",&-5",&-D - "67E,6?EC:4=6;64E:@?*:>6",* - "67E,6?EC:4=6&C6 ;64E:@?&6C:@5 ",&& - ?E6CG6?EC:4F=2C)6AEF>,) - "67E,6?EC:4=6?E6C?2=:2>6E6C ", - "67E,6?EC:4=6&@DE6C:@C-2== *9:4<?6DD",&- • #:EC2=,2=G6 - &@:?E E@ )6AEF>)6A2C2E:@? &)) - #:EC2=,2=G6"627=6E)6A2C2E:@? I4FCD:@? - #:EC2=,2=G6?E6C:@C"627=6E I4FCD:@? I4FCD:@? RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286 @7 % - #:EC2=,2=G6 )=@A6 )=@A6 - #:EC2=,2=G6 )=@A6 )=@A6 • &F=>@?:4,2=G6 - '()4@>A=6IE@6?5@76?G6=@A6 ' E@ &,4=@D6 • (:89E,6?EC:4=6 - (:89E,6?EC:4=6?E6C?2=:2>6E6C (,5(,D - (:89E,6?EC:4=6-2==*9:4<?6DD (,-5(,-D - (:89E,6?EC:4=6%FE7=@H*C24E :2>6E6C(,%*:2> - (:89E,6?EC:4=6;64E:@?*:>6(,* - (:89E,6?EC:4=6&C6 ;64E:@?&6C:@5 (,&& )JDE6> - &6C:42C577FD:@?&5 • *C:4FDA:5,2=G6 - '()4@>A=6IE@6?5@76?G6=@A6 ' E@ *,4=@D6 6773-86,--)9;8-4-5:9 • @CE:4,2=G6 - @CE:4?DF77:4:6?4J#62?&C6DDFC6 C25:6?E(*C246 - @CE:4?DF77:4:6?4J&62<&C6DDFC6 C25:6?E(,>2I - @CE:4?DF77:4:6?4J?5:2DE@=6 &C6DDFC6C25:6?E(*C246 - @CE:4?DF77:4:6?4J#62?,6=@4:EJ (*C246 - @CE:4?DF77:4:6?4J,6=@4:EJ*:>6 ?E68C2=(*C246 - @CE:4,2=G6#62?,6=@4:EJ, *C246 - @CE:4,2=G6,6=@4:EJ*:>6?E68C2= ,*C246 - @CE:4,2=G6#62?&C6DDFC6 C25:6?E,*C246 - @CE:4,2=G6&62<&C6DDFC6 C25:6?E(,>2I - @CE:4?DF77:4:6?4J&62<,6=@4:EJ (,>2I - @CE:4?DF77:4:6?4J?5 :2DE@=:4 ,6=@4:EJ(*C246 - @CE:4,2=G6&62<,6=@4:EJ, ,>2I - @CE:4,2=G6&62<,6=@4:EJ2E&@:?E ,,>2I - @CE2&C@I:>2=@2C4E2E:@?@2C4 &C6 F4E - @CE2:DE2=@2C4E2E:@?@2C4 &@DE F4E - @CE:4,2=G6?DF77:4:6?4J&C6DDFC6 2=7*:>6(&* - @CE:4,2=G6=@H446=6C2E:@?, *C246 - @CE:4,2=G6&C6DDFC62=7*:>6, *C246 - @CE:4,2=G6446=6C2E:@?*:>6, 44*:>6 - @CE:4,2=G6646=6C2E:@?*>6, *C246 - @CE:4,2=G6;64E:@?*:>6,* - @CE:4,2=G6446=6C2E:@?E@ ;64E:@?*:>6(2E:@,44*:>6 ,* - @CE:4,2=G6C62244@C5:?8E@&* • "67E,6?EC:4=6 - "67E,6?EC:4=6%FE7=@H*C24E&62< &C6DDFC6C25:6?E,"%*,>2I - "67E,6?EC:4=6%FE7=@H*C24E&62< ,6=@4:EJ",%*,>2I - "67E,6?EC:4=6%FE7=@H*C24E#62? &C6DDFC6C25:6?E",%**C246 - "67E,6?EC:4=6%FE7=@H*C24E#62? ,6=@4:EJ",%**C246 - "67E,6?EC:4=6%FE7=@H*C24E ,6=@4:EJ*:>6?E68C2=",%**C246 - "67E,6?EC:4=6;64E:@?*:>6",* #:EC2=,2=G6 - #:EC2=,2=G6(68FC8:E2?E=@H 446=6C2E:@?#(*C246 - #:EC2=,2=G6(68FC8:E2?E#62? ,6=@4:EJ#(*C246 - #:EC2=(68FC8:E2?E#62?&C6DDFC6 C25:6?E#(*C246 - #:EC2=(68FC8:E2?E,6=@4:EJ*:>6 ?E68C2=#(*C246 - #:EC2=,2=G6#62?,6=@4:EJ#( *C246 - #:EC2=,2=G6,6=@4:EJ*:>6?E68C2= #(*C246 - #:EC2=,2=G6#62?&C6DDFC6 C25:6?E#(*C246 - #:EC2=(68FC8:E2?E&62<&C6DDFC6 C25:6?E#(,>2I - #:EC2=,2=G6&62<&C6DDFC6 C25:6?E#(,>2I - #:EC2=(68FC8:E2?E&62<,6=@4:EJ #(,>2I - #:EC2=,2=G6&62<,6=@4:EJ#( ,>2I - #:EC2=,2=G6,6=@4:EJ&62<#, ,6=@4:EJ - #:EC2=,2=G6,6=@4:EJ&62<#, ,6=@4:EJ - #:EC2=,2=G6C62244@C5:?8E@&* #,&* - #:EC2=,2=G6=@H646=6C2E:@?#, *C246 - #:EC2=,2=G6&C6DDFC62=7*:>6&, &* - #:EC2=,2=G6=@H446=6C2E:@?#, *C246 - #:EC2=,2=G6 &62<E@ &62< (2E:@ 2?5 #,(2E:@ - #:EC2=,2=G6446=6C2E:@?*:>6#, 44*:>6 - #:EC2=,2=G6646=6C2E:@?*:>6#, 64*:>6 - #:EC2=,2=G6;64E:@?*:>6#, *C246 - #:EC2=,2=G6 -2G6FC2E:@?#, FC - #:EC2=,2=G6*:>6E@&62<#, *C246 - #:EC2=,2=G6446=6C2E:@? *:>6646=6C2E:@?*:>6(2E:@ #,4464*:>6 - )EC@<6,@=F>6?56I3J#:EC2= =@H#,&=2?:>6ECJ#,*C246 &F=>@?:4,2=G6 - &F=>@?:4?DF77:4:6?4J&62< &C6DDFC6C25:6?E&(,>2I - &F=>@?:4?DF77:4:6?4J?5 :2DE@=:4&C6DDFC6C25:6?E &(*C246 - &F=>@?:4,2=G6&62<&C6DDFC6 C25:6?E&,,>2I - &F=>@?:4?DF77:4:6?4J&62< ,6=@4:EJ&(,>2I - &F=>@?:4?DF77:4:6?4J?5 :2DE@=:4,6=@4:EJ&C6?5,>2I - &F=>@?:4,2=G6&62<,6=@4:EJ&, ,>2I - &F=>@?2CJCE6CJ:2DE@=:4 &C6DDFC6&,*C246 - &F=>@?:4?DF77:4:6?4J#62? &C6DDFC6C25:6?E&(*C246 - &F=>@?:4,2=G6#62?&C6DDFC6 C25:6?E&,*C246 - &F=>@?:4?DF77:4:6?4J#62? )BF2C6(@@E,6=@4:EJ&(*C246 - &F=>@?:4?DF77:4:6?4J,6=@4:EJ *:>6?E68C2=&(*C246 - &F=>@?:4,2=G6#62?,6=@4:EJ&, *C246 - &F=>@?:4,2=G6,6=@4:EJ*:>6 ?E68C2=&,*C246 - &F=>@?:4?DF77:4:6?4J&C6DDFC6 2=7*:>6&(&* - &F=>@?:4,2=G6=@H446=6C2E:@? &,44*:>6 - &F=>@?:4,2=G6446=6C2E:@?*:>6 &,44*:>6 - &F=>@?:4,2=G6;64E:@?*:>6 &,* - '()4@>A=6IE@6?5@76?G6=@A6 ' E@ &,4=@D6 - &F=>@?:4,2=G6446=6C2E:@?E@ ;64E:@?*>6(2E:@&,44*:>6 &,* (:89E,6?EC:4=6 - (:89E,6?EC:4=6%FE7=@H*C24E&62< &C6DDFC6C25:6?E(,%*,>2I - (:89E,6?EC:4=6%FE7=@H*C24E&62< ,6=@4:EJ(,%*,>2I - (:89E,6?EC:4=6%FE7=@H*C24E ,6=@4:EJ*:>6?E68C2=(,%**C246 - (:89E,6?EC:4=6;64E:@?*:>6(, *C246 - )EC@<6,@=F>63J&F=>@?:4=@H (,%*&=2?:>6ECJ(,%**C246 RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286 @7 % - (:89E,6?EC:4=6)EC@<6,@=F>6 ?56I3J&F=>@?:4=@H(,%* &=2?:>6ECJ(,%**C246 • )JDE6> - &F=>@?2CJCE6CJ&62<,6=@4:EJ&, ,>2I - &F=>@?2CJ,6:?,6=@4:EJ&62< C6G6CD6&,6:? - &F=>@?2CJ,6:?&62<,6=@4:EJ& ,6:?&,6:?) - )JDE6>:4,6:?&62<,6=@4:EJ& :2DE@=:4&)JDE@=:4 - ,6?EC:4F=2C)6AE2=6764E&62< ,6=@4:EJ,),>2I - EC:2=)6AE2=6764E):2DE@=:4 ))JDE@=:4 - &F=>@?2CJ,6:? -2G6FC2E:@? &,6:?FC - D@,@=F>6EC:4(6=2I2E:@?*:>6 ,(* - D@,@=F>6EC:4@?EC24E:@?*:>6 ,* - &F=>@?2CJ,6:?)(2E:@&,6:? &,6:?) - ,6?EC:4F=2C)6AE2=6764E&62< &C6DDFC6C25:6?E,),>2I - &F=>@?:4 E@ )JDE6>:4=@H(2E:@ 'A'D • *C:4FDA:5,2=G6 - *C:4FDA:5(68FC8:E2?E&62< &C6DDFC6C25:6?E*(,>2I - *C:4FDA:5,2=G6&62<&C6DDFC6 C25:6?E*,,>2I - *C:4FDA:5(68FC8:E2?E&62< ,6=@4:EJ*(,>2I - *C:4FDA:5,2=G6&62<,6=@4:EJ*, ,>2I - *C:4FDA:5,2=G6,6=@4:EJ&62<*, ,6=@4:EJ - *C:4FDA:5,2=G6,6=@4:EJ&62<*, ,6=@4:EJ - *C:4FDA:5(68FC8:E2?E#62? &C6DDFC6C25:6?E*(*C246 - *C:4FDA:5,2=G6#62?&C6DDFC6 C25:6?E*,*C246 - *C:4FDA:5(68FC8:E2?E#62? ,6=@4:EJ*(*C246 - *C:4FDA:5(68FC8:E2?E,6=@4:EJ *:>6?E68C2=*(*C246 - *C:4FDA:5,2=G6#62?,6=@4:EJ*, *C246 - *C:4FDA:5,2=G6,6=@4:EJ*:>6 ?E68C2=*,*C246 - *C:4FDA:5,2=G6*:>6E@&62<*, 4464*:>6 - *C:4FDA:5,2=G6;64E:@?*:>6*, 4464*:>6 - *C:4FDA:5,2=G6 -2G6FC2E:@? *,FC - '()4@>A=6IE@6?5@76?G6=@A6 ' E@ *,4=@D6 - *C:4FDA:5,2=G6&C6DDFC62=7*:>6 *,&* - )EC@<6,@=F>63J*C:4FDA:5=@H *,&=2?:>6ECJ*,*C246 - *C:4FDA:5,2=G6 &62<E@ &62< (2E:@*,,6=@4:EJ 636836=6,--)9;8-4-5:9 • @CE:4,2=G6 - &C@I:>2=D@G6=@4:EJ)FC7246C62 (68FC8:E2?E%C:7:46C62( (25:FD - &C@I:>2=D@G6=@4:EJ)FC7246C62 (25:FD@7=:2D65&@:?E((25:FD - &C@I:>2=D@G6=@4:EJ)FC7246C62 (68FC8:E2?E=@H(*C246 - &C@I:>2=D@G6=@4:EJ)FC7246C62 (68FC8:E2?E,@=F>6=@H( *C246 - &C@I:>2=D@G6=@4:EJ)FC7246C62 =:2D65,6=@4:EJ(,>2I • #:EC2=,2=G6 - &C@I:>2=D@G6=@4:EJ)FC7246C62 (68FC8:E2?E%C:7:46C62#( (25:FD - &C@I:>2=D@G6=@4:EJ)FC7246C62 (25:FD@7=:2D65&@:?E#((25:FD - &C@I:>2=D@G6=@4:EJ)FC7246C62 (68FC8:E2?E=@H#(*C246 - &C@I:>2=D@G6=@4:EJ)FC7246C62 (68FC8:E2?E,@=F>6=@H#( *C246 - &C@I:>2=D@G6=@4:EJ)FC7246C62 =:2D65,6=@4:EJ#(,>2I 64*15):1656,- -)9;8-4-5:9 • @CE:4,2=G6 - @CE:4,2=G6C62@(@@E:2> ",%*,>2I,,>2I - @CE:4,2=G6C623J@?E:?F:EJ BF2E:@?3J&62<,6=@4:EJ@(@@E :2>",%*,>2I,,>2I - )EC@<6,@=F>63J@CE:4=@H, &=2?:>6ECJ,*C246 - 2C5:24%FEAFE3J@CE:4=@H, &=2?:>6ECJ,*C246( - @CE:4,2=G6C623J@?E:?F:EJ BF2E:@?,*@(@@E:2>",%* ,>2I,*C246 • "67E,6?EC:4=6 - 2C5:24%FEAFE*6:499@=KF3:4 ",5",D( - 2C5:24%FEAFE*H@92>36C ):?8=6&=2?6C62 "6?8E9#6E9@5 @7:D<):>AD@?",5",D( - 2C5:24%FEAFE@FC92>36C ):?8=6&=2?6C62 "6?8E9#6E9@5 @7:D<):>AD@?",5",D( - ;64E:@?C24E:@?*H@92>36C ):?8=6&=2?6C62 "6?8E9#6E9@5 @7:D<):>AD@?",5",D - ;64E:@?C24E:@?@FC92>36C ):?8=6&=2?6C62 "6?8E9#6E9@5 @7:D<):>AD@?",5",D - "67E,6?EC:4=6)EC@<6,@=F>6 ):?8=6&=2?6*H@92>36C@FC 92>36CC62 "6?8E9",5 ",D - "67E,6?EC:4=6)EC@<6,@=F>6 ):?8=6&=2?6*H@92>36C@FC 92>36C#6E9@5@7:D< ):>AD@?",5",D",5 ",D - "67E,6?EC:4=6,@=F>6*H@ 92>36C@FC92>36CC62 "6?8E9",5",D - ;64E:@?C24E:@?: &=2?6#6E9@5 @7:D<",5",D - "67E,6?EC:4=6)EC@<6,@=F>6: &=2?6#6E9@5@7:D<",5",D - "67E,6?EC:4=6,@=F>6: &=2?6 #6E9@5@7:D<",5",D - "67E,6?EC:4=6)EC@<6?56I):?8=6 &=2?6*H@92>36C@FC 92>36CC62 "6?8E9",)5",)D 2?5) - "67E,6?EC:4=6,@=F>6):?8=6&=2?6 *H@92>36C@FC92>36C #6E9@5@7:D<",5",D - "67E,6?EC:4=6,@=F>6A:42=,:6H "@?8I:D#6E9@5@7:D<",5 ",D #:EC2=,2=G6 - )EC@<6,@=F>63J#:EC2==@H#, &=2?:>6ECJ#,*C246 - 2C5:24%FEAFE3J#:EC2==@H #,&=2?:>6ECJ#,*C246( • &F=>@?:4,2=G6 - )EC@<6,@=F>63J&F=>@?:4=@H &,&=2?:>6ECJ&,*C246 - 2C5:24%FEAFE3J&F=>@?:4=@H &,&=2?:>6ECJ&,*C246( • *C:4FDA:5,2=G6 - 2C5:24%FEAFE3J*C:4FDA:5=@H *,&=2?:>6ECJ*,*C246( )8,1)+&68290--: • &2C2>6E6C=:DEDE96>@56E96 >62DFC6>6?E7@=56C2?5E96 DA64:7:4>62DFC6>6?E • #62DFC65,2=F6+AE@D:I >62DFC6>6?EG2=F6D7@C6249:E6> G6C286>2I:>F>>:?:>F>@C =2DE RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. "%'&C@5F4E2E2)966E1=@32= &286 @7 % -5-81+":;,?15)8,1636/? • )EC@<6,@=F>6), • 2C5:24%FEAFE% RI EQUIP# IUS02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. TRUMPF Medical Systems Inc. · 1046 LeGrand Blvd. · Charleston, SC 29492 Phone: 1-888-474-9359 · Email: info@us.trumpf.com · Website: www.us.trumpf.com/med TruLight 1000 Examination Light The light: State of the art. With its LED technology, TruLight 1000 offers not only higher intensity, but better light quality than conventional halogen lights. The emitted light is optimally distributed by a special optical lighting system which provides a homogenous area of light for best possible visualization during examinations and treatment. Handling: simple, flexible, convenient. Specially balanced support arms, and low weight light head, make TruLight 1000 easy to position. Plus, with the sterilizable handle, it is suitable for hygienically critical applications. Everything you could want in comfort and flexibility. The place: everywhere. TruLight 1000 is available in ceiling-mounted, boom-mounted and mobile models. With its high flexibility and space-saving compact design, it is a necessity for hospital exam/treatment, critical care, delivery, as well as prep and recovery rooms. Think of it as the “one for all” light. 9” (230 mm)Diameter of light head ≈35 W Power consumption 150 W/m²Irradiance Ra 93Color rendering index (CRI) 50 – 100%, 3 stepsDimming 4,600 KColor Temperature 7” (18 cm)Light field diameter 50,000 LuxLight intensity Specifications* *subject to change EQUIP# LET01 32 TruLight 1000: Value and fl exibility. Now you can have all the benefi ts of LED technology in your examination light: greater light intensity, longer service life, lower heat generation and minimal power consumption. Couple this with impressive mobility and sound ergonomics, and you have an examination lamp for multiple applications. The light: state of the art. With its LED technology, TruLight 1000 offers not only higher light intensity, but superior light quality when compared to conventional halogen lights. Light is optimally distributed by the unique TRUMPF multi-lens matrix and Fresnel lens, which provides a homogenous area of light for the best possible visualization during examination and minor procedures. Handling: simple, fl exible, convenient. With specially balanced support arms and a very light weight, the TruLight 1000 is easy to position. Plus, with the sterilizable handle, it is suitable for hygienically critical applications. Everything you could want in comfort and fl exibility. The place: everywhere. TruLight 1000 is available in ceiling-mounted, wall-mounted and mobile versions. With its high fl exibility and space-saving compact design, it is a necessity for medical practices, outpatient clinics, and hospital examination and delivery rooms, as well as preparation and recovery areas. Think of it as the “one for all” light. Energy effi ciency: power meets economy. The advantages over halogen are compelling: signifi cantly longer service life, less heat generated, built in fail-safe and lower power consumption. It’s true effi ciency made by TRUMPF, naturally. Technical data TruLight 1000 Central illuminance in 1 m distance 50,000 lux Colour temperature 4,500 K Field size d10 in 1 m distance 7.2" Colour rendering index max. Ra 94 Life expectancy of the light source 20,000 hrs EQUIP# LET01 Part No. 2718-55-16 OPERATION MANUAL © 2010 IVY Biomedical Systems Inc. All Rights Reserved. Part No. 2718-04-16 Cardiac Trigger Monitor Model 3000 Series EQUIP# MTR01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. SPECIFICATIONS 32 Model 3000 Operation Manual Specifications ECG Lead Selection: LI, LII, LIII menu selectable. Patient Cable: 6-Pin AAMI Standard connector Isolation: Isolated from ground related circuits by >4 kV rms, 5.5 kV peak CMRR: ≥90 dB with patient cable and 51 kΩ/47 nF imbalance Input Impedance: ≥20 MΩ at 10 Hz with patient cable Frequency Response LCD: Filtered: 0.5 to 25 Hz Unfiltered: 0.5 to 45 Hz Frequency Response X1000 output: Filtered: 0.5 to 25 Hz Unfiltered: 0.2 to 100 Hz Input Bias Current: Any lead configuration <200 nA dc maximum Electrode Offset Potential: ±0.5 V DC Lead Off sensing current: 56nA Noise: <20 µV peak-to-peak, referred to the input with all leads connected through 51 kΩ/47 nF to ground Defibrillator Protection: Protected against 360 J discharge and electrosurgery potentials Recovery time <6s Leakage Current: <10 µA at normal condition Electrosurgical Interference Protection: Standard. Recovery time: <6 seconds. Notch Filter: 50/60 Hz (automatic). Cardiotach Range: 15 to 300 bpm Accuracy: ±1% Resolution: 1 bpm Sensitivity: 300 µV peak Heart Rate Averaging: Exponential averaging calculated once a second with a maximum response time of 8 seconds. Response Time: ≤ 8 seconds Tall T Wave Rejection: Rejects T waves ≤R wave EQUIP# MTR01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. SPECIFICATIONS Model 3000 Operation Manual 33 Pacer Pulse Rejection Width: 0.1 to 2 ms at ±2 to ±700 mV Overshoot: Between 4 to 100ms and not greater than 2mV. Fast ECG signals: 2mV/100µs. Detector disabling: None. NOTE: Pacemaker pulses are not present in any rear panel outputs. Alarms High Rate: 15 to 250 bpm in 5 bpm increments Low Rate: 10 to 245 bpm in 5 bpm increments Asystole: R to R interval >6 seconds Lead Off: Detached lead or offset potential >0.5 V Test Mode ECG: 1 mV/100 ms @ 70 bpm Display Type: Active Matrix TFT Color LCD (640x480) Trace: Single ECG trace with “freeze” function. Screen Size: 13.25cm x 9.94cm, 16.5cm (6.5in)diagonal Sweep Speed: 25, 50 mm/s Aspect ratio: 0.4 (standard). User selectable. Mechanical Size: Height: 6.70in. (17.2cm) Width: 9.25in. (33.5cm) Depth: 9.21in. (23.4cm) Weight: 6.5lbs (2.9kg) Recorder (optional) Writing Method: Direct Thermal Number of Traces: 1 Modes: Direct - Manual Recording Timed - Print button initiates a 30 second recording Delay - Recorder is activated by an alarm Paper Speeds: 25 and 50 mm/s Resolution: Vertical - 200 dots/in. Horizontal - 600 dots/in. at ≤25 mm/s 400 dots/in. at >25 mm/s Frequency Response: >100 Hz at 50 mm/s Data Rate: 400 samples/s/trace EQUIP# MTR01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. SPECIFICATIONS 34 Model 3000 Operation Manual Synchronized Output (Trigger) Phase Delay from Electrode Leads to Trigger Output: < 3 ms R to R Trigger Accuracy: ±50µs typical @ 1 mV input Pulse width: 1 to 150ms (standard 150ms) Pulse amplitude: 0 to 5V, 5 to 0V, -11 to 11V Output Impedance: <100 Ω Sensitivity and Threshold Adjustment: Fully Automatic Polarity control: Positive edge or Negative edge. Output connectors: ECG X1000 (ECG X500 for GEMS) – Ring BNC connector RS232 Real Time Clock Resolution: 1 minute Display: 24 hours Power Requirement: The real time clock keeps time if the monitor has power or not. The clock is powered by a dedicated battery whose life is minimum 4 years at a temperature of 25oC Environmental Operating Temperature Range: 5°C to 35°C Storage Temperature Range: -20°C to 49°C Relative Humidity: 0-90% non-condensing Atmospheric Pressure: 500-1060 mbar Power Requirements Voltage Input: 100 to 230V~ Line Frequency: 47 to 63 Hz Fuses Type and Rating: T.5A, 250V (Metric 5x20mm) Maximum ac Power Consumption: 35 VA Regulatory Unit meets or exceeds the specifications for the AAMI Cardiac Monitor Standard EC-13, UL2601-1, CAN/CSA C22.2 No 601.1-M90, CDN MDR (CMDCAS), IEC 60601-2-25, IEC 60601-2-27, MDD.93/42/EEC, CE 0143, ISO 13485:1996, and FDA/CGMP. EQUIP# MTR01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 1000W/R-21LC R-21LCF Medium-Duty Commercial Microwave Oven This medium-duty commercial microwave features the durable quality and easy maintenance of a stainless steel interior. The cost-efficient R-21LCF also has a super-rugged grab handle. Features: Stainless Steel Interior and Door are designed with a high-grade stainless steel that is featured in every oven in Sharp’s commercial line. They’re easy to clean and resists pitting, chipping, scratching and erosion, even with a tough schedule of everyday use. Cool Gray Cabinet and Stainless Door provide a streamlined, style-setting look that suits any situation — from snack bars to offices. Dependable 6-Minute Light Up Dial Timer is clearly marked in 10,15 and 30 second increments for easy-to- set, easy-to-read convenience. When the door is opened during cooking,the remaining time is canceled eliminating the oven being on without a food load. Increments are lettered for use with coded foods. 1,000 Watts of Power built for fast,efficient heating. Heating Time Guide charts proper times needed to heat a variety of popular foods. It’s a handy “on-the- spot”reference for timesaving convenience. Sturdy Grab Handle designed to stand up to the daily demands of the medium-duty user, providing easy access. End of Heating Signal lets user know when food is ready. Interior Oven Light lets you view food as it cooks to monitor progress. See-through door and oven light promote maximum visibility. Ease of Cleaning of the rubber-sealed ceramic shelf makes it easy to keep oven in “ready-for-inspection” order. EQUIP# OVN01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. R-21LCF Medium-Duty Commercial Microwave Oven SHARP ELECTRONICS CORPORATION Sharp Plaza,Mahwah,NJ 07495-1163 For more information call:201-529-8619 or 1-800-BE-SHARP www.sharpusa.com © 2008 Sharp Electronics Corporation. All rights reserved. Printed in U.S.A. 05-05-08 CM-02-037 Specifications Model R-21LCF Output Wattage (IEC Procedure)1000 watts Stainless Steel Interior Yes Cool Gray Cabinet & Door Yes Power Requirements 1.6 kW,14.0 A Receptacle Required 15 Amp.,NEMA -15 R Cord Length (in inches)63 Warranty*1 Sharp commercial microwave ovens have a reputation for unsurpassed quality in the foodservice industry.This Sharp commercial microwave oven is backed by a three-year limited warranty on the magnetron tube and one-year warranty on parts and labor with service provided in the end-user’s place of business. See Operation Manual for complete details. Outside Unit Dimensions (w x h x d,in inches)20-1/2 x 12-1/8 x 16 Outside Unit Dimensions with Door Open (in inches)31-1/4 Cavity Dimensions (w x h x d,in inches)13-7/8 x 8-1/8 x 14-5/8 Net Weight / Shipping Weight 37 / 44 (in pounds) UPC 074000616493 *1 See warranty statement included in the product operation manual available as a PDF download at www.sharpusa.com. Sharp and all related trademarks are trademarks or registered trademarks of Sharp Corporation and/or its affiliated companies. All other trademarks are property of their respective owners. Design and specifications subject to change without notice. See operation manual for complete details. To Specify a Sharp R-21LCF Medium-Duty Commercial Microwave Oven - Oven shall comply with standards set by the U.S.Department of Health and Human Services, FCC,NSF-4 and UL and shall display such labels.Oven shall be equipped with 6-minute Light Up Dial timer marked in 10,15 and 30 second increments.Remaining time will be canceled if the door is opened during cooking.Heating Time Guide and instructions shall be visible on oven control panel.Output wattage shall be 1000 watts. Bottom feed distribution system shall provide uniform heating pattern.Oven cavity shall be of stainless steel construction with see-through stainless oven door.Cavity shall be illuminated.Bottom of cavity shall consist of rubber-sealed ceramic shelf.Oven shall have three-year limited warranty on the magnetron tube; one-year parts and labor with service provided in the end-user’s place of business.HA-08F-007Built to meet rugged commercial standards. Complies with DHHS & FCC. EQUIP# OVN01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. R-520LW Configuration Countertop Capacity (cu. ft.) 2.0 Microwave Output Power Watts 1200 Carousel Diameter (inches) 16 Display 7 digit/2 color Pre-programmed Settings Cooking Options Easy Access - 19 Sensor Cook® Settings 9 Popcorn Key Yes, Sensor Reheating Options sensor Defrosting Options 4 Other Conveniences Hot Water Yes KeepWarmPlus Yes Clock Yes Minute Timer Yes Minute Plus™ Key Yes Power Levels 11 Programmable Stages 4 Safety Lock Yes Demonstration Mode Yes Audible Signal Elimination Yes Additional Specifications AC Power Required (Amps) 14.3 Built-in Kit Available (Optional) Yes EQUIP# OVN03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 120V;60HZ;14.3A Additional Specifications Color Smooth White Limited Warranty 1 year Parts/Labor. 4 Additional years for Magnetron tube, part only Weight & Dimensions Weight (lbs) 41 Approx Ship Weight (lbs) 46 Cavity Dimensions (inches) Depth 18_5_8 Height 10 1/2 Width 17 3/8 Outside Dimensions (inches) Depth 19 1/8 Height 13 3/8 Width 24 EQUIP# OVN03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# RCK03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. laboratory pharmacy refrigerators LABORATORY REFRIGERATORS • i.Series® • Horizon Series™ PHARMACY REFRIGERATORS EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. introduction HPR125 helmer laboratory & pharmacy refrigerators provide the following benefits: The Added Safety of Bacteria-Resistant Powder Coating Our exclusive bacteria-resistant powder coating process is used on each refrigerator’s exterior, interior, and door handle(s). Sure Seal Door Closure The pioneering design of Helmer Sure-Seal self-closing doors with magnetic closure eliminates the problem of broken door latches. Superior Chamber Temperature Uniformity Industrial grade fan(s) provide excellent air circulation in the chamber for maximum temperature uniformity and quick recovery. No Defrost Cycle Needed Helmer’s balance flow refrigeration system eliminates the need for a defrost cycle. With no defrost timers to fail and no temperature fluctuations during defrost cycles, your valuable products are ensured a constant temperature throughout the storage period. Conserves Your Valuable Floor Space When a Helmer refrigerator door is opened, it is contained within the cabinet’s width dimension. The refrigerator can be positioned next to a countertop, cabinet, or another unit with no additional clearance space required. A Size and Configuration to Fit Your Needs Single and double door configurations in both 30” (76cm) and 36” (92cm) depths mean there is a size just right for your space and application. Easy Installation Helmer’s Pass-Thru cabinet heights allow passage through 80” (203.2cm) high doorways. Installation and cleaning are made easier as all Helmer refrigerators come complete with swivel locking casters. LABORATORY & PHARMACY REFRIGERATORS Helmer is proud to offer our laboratory and pharmacy refrigerators to the life science market. These refrigerators are available in both the i.Series and Horizon Series lines and offer outstanding benefits to provide the most secure environment for your valuable products. The feature-rich i.Series line provides the most advanced security and monitoring capabilities with the i.Center® Integrated Monitoring System. The Horizon Series offers all essential features along with solid performance and quality. Both series were designed and manufactured specifically for life science storage applications and feature superior cabinet construction, foamed-in-place urethane insulation, and uniform temperature. For the most secure temperature control environment, select the Helmer laboratory or pharmacy refrigerator that fits your specific needs. iLR256 EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. standard features shelves • Standard on laboratory refrigerators • Zinc-plated, powder coated wire shelves • Height is adjustable on 1” (2.5cm) centers • Maximum load 100 lb (46 kg) per shelf • Stainless steel shelf standards • Side and rear guards prevent items from falling off the shelf • Available in full and half-size • Standard on pharmacy refrigerators • Solid stainless steel pull out drawers • Drawers are 4” (10cm) high • Height is adjustable on 1” (2.5cm) centers • Maximum load 100 lb (46 kg) per drawer • Durable, liquid-tight construction • Easy access to inventory with fully extendable drawer slides • Scratch-Guard edge protectors keep glass doors from being scratched i.Series drawer shown with labeland Scratch-Guard edge protection Horizon Series drawer with Scratch-Guard edge protection Dual, swivel locking caster cabinet construction • Ergonomic Sure-Grip door handle(s) are bacteria-resistant powder-coated and padded for comfort • Interior, exterior, and door handle(s) are galvannealed steel with bacteria resistant powder coating • Superior engineered frame for maximum rigidity • Dual pane glass door(s) (heated glass doors optional) • Standard key lock • Innovative self-closing Sure-Seal door system • Minimum of 2” (5cm) non-CFC foamed urethane insulation • Dual, swivel locking casters • One side wall access port with interior and exterior plugs. Port diameter is 1.75” (4.5cm) • Recessed floor contains spills for easy clean-up • Interior fluorescent light with control panel mounted switch temperature control and monitoring • All Helmer i.Series Refrigerators incorporate the exclusive i.Center® Integrated Monitoring System, described on page 4. • Dual, stainless steel monitoring probes mounted in product simulation bottles horizon series • All Horizon Series Refrigerators feature a microprocessor temperature controller with built-in alarm/monitor, described on page 5. • Single, stainless steel monitoring probe mounted in product simulation bottle • Digital microprocessor temperature controller factory set to +4ºC -Controller is equipped with a temperature probe mounted in the chamber -Digital offset adjustment for controller calibration refrigeration system • Heavy-duty, air-cooled, forced-air refrigeration system • Non-CFC, commercially available refrigerant • Automatic condensate evaporator is standard • Internal evaporator fan(s) shut off during door openings • Balance flow refrigeration system eliminates defrost cycle and maintains constant temperatures only and horizon series drawers • Sure-Grip coordinated drawer handles have built-in ledge for labels and horizon series and horizon series EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. i.series monitoring features • Microprocessor-based alarm/monitoring system is independent from the temperature controller• Digital display of upper and lower chamber temperatures• Dual, stainless steel RTD temperature probes located in product simulation bottles• Automatic high/low alarm testing that works at the touch of a button (Peltier based)• Event log records alarm conditions with date and time• “Soft” programmable buttons• System status with visual and audible alarms• Exclusive i.Help provides on-board help for system training and service• Both temperature alarm probes are easily accessible for manual alarm checks• Dry contact connection to remote alarm systems• Digital calibration• Continuous “automatic battery check” system• Door open counter resets itself daily• Date and time display• Battery backup• Password protected configuration• Monitors condenser temperature for efficiency and alarm conditions• LCD continuous 24-hour temperature graph operates as a screen saver• Flash memory upgradable• Optional RS232 port audible and visual system alarms and alerts • High and low temperature alarms• Door ajar alarm• Power failure alarm• Condenser efficiency alarm• No battery alarm• Low battery alert* * Visual only user defined settings • Date and time format• Alarm temperature setpoints• Time delays on door ajar and power failure alarms• Mute and ring-back intervals• Viewscreen contrast• Alarm volume• Four alarm options: single beep, double beep, triple beep, continuous• Optional alarm function for lower temperature probe• Password protection• 24-hour temperature graph display i.Center technology is exclusive to the i.Series line from Helmer. It constantly monitors the chamber temperature and critical refrigerator functions, safeguarding the products inside and providing valuable information to the user. At the heart of the system is the large, easy-to-read digital viewscreen, which is your window into a powerful array of features. i.Center with 24-hour temperature graph i.Center Main Screen i.Center Alarm Set Point Screen EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. main features • LED digital display of chamber temperature during “Run Mode” • Power failure alarm • Battery backup temperature controller features • Programmable operating temperature range • Stainless steel RTD temperature probe mounted in the chamber • Digital offset adjustment for system calibration • LED display of temperature set point in “Program Mode” alarm/monitor features • Programmable high and low temperature alarms with visual and audible indicators • LED display of high and low temperature alarm set points in “Program Mode” • Alarm mute with 5 minute ring-back interval • Alarm silence with key switch • Stainless steel RTD probe located in simulation bottle • Alarm temperature probe is accessible for manual alarm checks • Dry contact connection to remote alarm systems • Digital offset adjustment for system calibration • Door ajar alarm The Horizon Series microprocessor temperature controller with alarm/monitor provides a controlled, stable temperature environment for products stored in your refrigerator. Audible and visual high/low temperature alarms add the security of constant monitoring. The LED display is easy to read and settings are adjustable. horizon seriesmonitoring CONTROLLER / ALARM MONITOR Horizon Series Control Panel EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. laboratory refrigerators HLR120iLR245iLR125 laboratory refrigerator specifications • Dual pane glass door(s). • Four full shelves in single door models. Eight full shelves in double door models. • One access port with interior and exterior plugs. • Refrigerator can be configured with a combination of half and full size shelves, roll-out baskets, or solid stainless steel drawers. (See Storage Options on page 9) Model iLR120 / HLR120 iLR125 / HLR125 iLR245 / HLR245 iLR256 / HLR256 Doors Single Dual-Pane Glass Door (Heated Glass Optional) Double Dual-Pane Glass Doors (Heated Glass Optional) Interior Material Bacteria-Resistant Powder Coated Galvannealed Steel Interior Volume 20.2 cu ft / 572 liter 25.2 cu ft / 714 liter 44.9 cu ft / 1271 liter 56 cu ft / 1586 liter Casters 4 Dual, Swivel Locking 6 Dual, Swivel Locking Shelves 4 Full Size, Adjustable 8 Full Size, Adjustable Insulation 2” (5cm) Minimum Non-CFC Foamed Urethane Lights Dual bulb, fluorescent Refrigeration 1/3 HP Air-Cooled, R134A Non-CFC 1/2 HP Air-Cooled, R134A Non-CFC Electrical*115 Volt 60Hz 7.5 FLA 230 Volt 50Hz 4 FLA 230 Volt 60Hz 4 FLA 115 Volt 60Hz 11.5 FLA 230 Volt 50Hz 6 FLA 230 Volt 60Hz 6 FLA i.Series iLR120 iLR125 iLR245 iLR256 Interior Dimensions (w x h x d) 24.75” x 58.25” x 24.25” 63cm x 148cm x 62cm 24.75” x 58.25” x 30.25” 63cm x 148cm x 77cm 55.0” x 58.25” x 24.25” 140cm x 148cm x 62cm 55.0” x 58.25” x 30.25” 140cm x 148cm x 77cm Exterior Dimensions (w x h x d) 29.5” x 79.75” x 29.5” 75cm x 203cm x 75cm 29.5” x 79.75” x 35.5” 75cm x 203cm x 91cm 59.25” x 79.75” x 29.5” 151cm x 203cm x 75cm 59.25” x 79.75” x 35.5” 151cm x 203cm x 91cm Overall Exterior Dimensions¹ (w x h x d) 29.5” x 79.75” x 32.5” 75cm x 203cm x 83cm 29.5” x 79.75” x 38.5” 75cm x 203cm x 98cm 59.25” x 79.75” x 32.5” 151cm x 203cm x 83cm 59.25” x 79.75” x 38.5” 151cm x 203cm x 98cm Net Weight 465 lb / 211 kg 476 lb / 216 kg 692 lb / 314 kg 754 lb / 342 kg Horizon Series HLR120 HLR125 HLR245 HLR256 Interior Dimensions (w x h x d) 24.75” x 58.25” x 24.25”63cm x 148cm x 62cm 24.75” x 58.25” x 30.25”63cm x 148cm x 77cm 55.0” x 58.25” x 24.25”140cm x 148cm x 62cm 55.0” x 58.25” x 30.25”140cm x 148cm x 77cm Exterior Dimensions (w x h x d) 29.5” x 78.75” x 29.5” 75cm x 201cm x 75cm 29.5” x 78.75” x 35.5” 75cm x 201cm x 91cm 59.25” x 78.75” x 29.5” 151cm x 201cm x 75cm 59.25” x 78.75” x 35.5” 151cm x 201cm x 91cm Overall Exterior Dimensions¹ (w x h x d) 29.5” x 78.75” x 32.5” 75cm x 201cm x 83cm 29.5” x 78.75” x 38.5” 75cm x 201cm x 98cm 59.25” x 78.75” x 32.5” 151cm x 201cm x 83cm 59.25” x 78.75” x 38.5” 151cm x 201cm x 98cm Net Weight 465 lb / 211 kg 476 lb / 216 kg 692 lb / 314 kg 754 lb / 342 kg laboratory refrigerator dimensions Specifications subject to change Certified to UL and CSA standards by Entela Meets IEC 61010 Standard *External transformers are not utilized¹ Includes door handle, electrical panel, and evaporation tray EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. pharmacyrefrigerators HPR120 iPR256iPR125 • Dual pane glass door(s). • Six stainless steel drawers in single door models. Twelve stainless steel drawers in double door models. • One access port with interior and exterior plugs. • Refrigerator can be configured with a combination of half and full size shelves, roll-out baskets, or solid stainless steel drawers. (See Storage Options on page 9) pharmacy refrigerator specifications Model iPR120 / HPR120 iPR125 / HPR125 iPR245 / HPR245 iPR256 / HPR256 Doors Single Dual-Pane Glass Door (Heated Glass Optional) Double Dual-Pane Glass Doors (Heated Glass Optional) Interior Material Bacteria-Resistant Powder Coated Galvannealed Steel Interior Volume 20.2 cu ft / 572 liter 25.2 cu ft / 714 liter 44.9 cu ft / 1271 liter 56 cu ft / 1586 liter Casters 4 Dual, Swivel Locking 6 Dual, Swivel Locking Drawers 6 Solid Stainless Steel, Adjustable 12 Solid Stainless Steel, Adjustable Insulation 2” (5cm) Minimum Non-CFC Foamed Urethane Lights Dual bulb, fluorescent Refrigeration 1/3 HP Air-Cooled, R134A Non-CFC 1/2 HP Air-Cooled, R134A Non-CFC Electrical*115 Volt 60Hz 7.5 FLA 230 Volt 50Hz 4 FLA 230 Volt 60Hz 4 FLA 115 Volt 60Hz 11.5 FLA 230 Volt 50Hz 6 FLA 230 Volt 60Hz 6 FLA i.Series iPR120 iPR125 iPR245 iPR256 Interior Dimensions (w x h x d) 24.75” x 58.25” x 24.25” 63cm x 148cm x 62cm 24.75” x 58.25” x 30.25” 63cm x 148cm x 77cm 55.0” x 58.25” x 24.25” 140cm x 148cm x 62cm 55.0” x 58.25” x 30.25” 140cm x 148cm x 77cm Exterior Dimensions (w x h x d) 29.5” x 79.75” x 29.5” 75cm x 203cm x 75cm 29.5” x 79.75” x 35.5” 75cm x 203cm x 91cm 59.25” x 79.75” x 29.5” 151cm x 203cm x 75cm 59.25” x 79.75” x 35.5” 151cm x 203cm x 91cm Overall Exterior Dimensions¹ (w x h x d) 29.5” x 79.75” x 32.5”75cm x 203cm x 83cm 29.5” x 79.75” x 38.5”75cm x 203cm x 98cm 59.25” x 79.75” x 32.5”151cm x 203cm x 83cm 59.25” x 79.75” x 38.5”151cm x 203cm x 98cm Net Weight 510 lb / 231 kg 535 lb / 243 kg 800 lb / 363 kg 880 lb / 400 kg Horizon Series HPR120 HPR125 HPR245 HPR256 Interior Dimensions (w x h x d) 24.75” x 58.25” x 24.25”63cm x 148cm x 62cm 24.75” x 58.25” x 30.25”63cm x 148cm x 77cm 55.0” x 58.25” x 24.25”140cm x 148cm x 62cm 55.0” x 58.25” x 30.25”140cm x 148cm x 77cm Exterior Dimensions (w x h x d) 29.5” x 78.75” x 29.5”75cm x 201cm x 75cm 29.5” x 78.75” x 35.5”75cm x 201cm x 91cm 59.25” x 78.75” x 29.5”151cm x 201cm x 75cm 59.25” x 78.75” x 35.5”151cm x 201cm x 91cm Overall Exterior Dimensions¹ (w x h x d) 29.5” x 78.75” x 32.5”75cm x 201cm x 83cm 29.5” x 78.75” x 38.5”75cm x 201cm x 98cm 59.25” x 78.75” x 32.5”151cm x 201cm x 83cm 59.25” x 78.75” x 38.5”151cm x 201cm x 98cm Net Weight 510 lb / 231 kg 535 lb / 243 kg 800 lb / 363 kg 880 lb / 400 kg pharmacy refrigerator dimensions *External transformers are not utilized¹ Includes door handle, electrical panel, and evaporation tray Specifications subject to change Certified to UL and CSA standards by EntelaMeets IEC 61010 Standard *External transformers are not utilized ¹ Includes door handle, electrical panel, and evaporation tray EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Depth - 32.5” (83cm) including door handle, electrical panel & evaporation tray Depth - 38.5” (98cm) including door handle, electrical panel & evaporation tray Depth - 38.5” (98cm) including door handle, electrical panel & evaporation tray specifications iLR120 HLR120 iPR120 HPR120 29.5”(75cm) Depth - 32.5” (83cm) including door handle, electrical panel & evaporation tray29.5”(75cm) 29.5”(75cm) 59.25”(151cm) 35.5”(91cm) 29.5”(75cm) iLR125 HLR125 iPR125 HPR125 59.25”(151cm) 35.5”(91cm) iLR245HLR245 iPR245 HPR245 iLR256 HLR256 iPR256 HPR256 horizon series unit height i.series unit height 79.75”(203cm)78.75”(201cm) footprint EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. storage options customizable to meet your inventory storage needs For maximum versatility, Helmer refrigerators can be customized with any combination of optional half or full size shelves, stainless steel drawers, or roll out baskets (sold separately from the standard storage items included with the refrigerator). If you wish to reconfigure your refrigerator, optional storage items may be customer installed. For factory installation, please request when ordering refrigerator.optional storage items Half Size Shelf with Hardware Zinc-plated, powder coated wire shelves are adjustable on 1” (2.5cm) centers. Designed with side and rear guards to prevent items from falling. Maximum load 30 lb (14 kg) per shelf. Description Part No. Half Shelf with Hardware (for all models) 400413-1 Full Size Shelf with Hardware Zinc-plated, powder coated wire shelves are adjustable on 1” (2.5cm) centers. Designed with side and rear guards to prevent items from falling. Maximum load 100 lb (46 kg) per shelf. Description Part No. Full Shelf with Hardware (for 20 or 45 cu ft models) 400414-1 Full Shelf with Hardware (for 25 or 56 cu ft models) 400414-2 Roll Out Basket with Hardware Zinc-plated, powder coated wire baskets are adjustable on 1” (2.5cm) centers. Scratch-Guard edge protectors keep glass refrigerator doors from being scratched. Maximum load 100 lb (46 kg) per basket. Description Part No. Roll Out Basket with Hardware (for 20 or 45 cu ft models) 400415-1 Roll Out Basket with Hardware (for 25 or 56 cu ft models) 400415-2 Solid Stainless Steel Drawer with Hardware Pull out drawers are 4” (10cm) high and adjustable on 1” (2.5cm) centers. Durable, liquid-tight drawer bottoms contain spills. Easy access to inventory with fully extendable drawer slides. Scratch-Guard edge protectors keep glass from being scratched. i.Series drawers feature Sure-Grip coordinated drawer handles with a built in ledge for labels. Maximum load 100 lb (46 kg) per drawer. Description Part No. i.Series Solid Stainless Steel Drawer (for 20 or 45 cu ft models) 400370-1 i.Series Solid Stainless Steel Drawer (for 25 or 56 cu ft models) 400370-2 Horizon Series Stainless Steel Drawers (for 20 or 45 cu ft models) 400370-3 Horizon Series Stainless Steel Drawers (for 25 or 56 cu ft models) 400370-4 Zinc-plated, powder coated wire shelves (half-size shelves available) i.Series stainless steel drawer with Sure-Grip handle and Scratch-Guard Horizon Series stainless steel drawer with Scratch-Guard Zinc-plated, powder coated wire roll out baskets EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. options &accessories door options Heated Glass Door UpgradeDescription Part No.Upgrade from Dual Pane Glass Door to Heated Glass Door (single) Z0112Upgrade from Dual Pane Glass Door to Heated Glass Door (double) Z0113 Solid Door DeductionDescription Part No.Glass Door to Solid Door deduction (single) Z0127Glass Door to Solid Door deduction (double) Z0128 Left-Hinged Single Door (Part No. 400394-1)Single door Laboratory and Pharmacy refrigerators come standard with a right hinged door. A left hinged single door is available. (Factory installed, add “LEFT” to the end of refrigerator model number.) options & accessories Stainless Steel InteriorOptional stainless steel interior is available. Specify when ordering. Temperature Validation (Part No. Q1F001)Helmer offers a temperature validation package that will certify the temperature performance of the refrigerator. A multiple point temperature recorder will map the temperature inside the refrigerator chamber and a document with the data will be provided. This option must be ordered at the time the refrigerator is purchased. Contact Helmer’s customer service department for additional details. Includes: • Documentation of the chamber temperature • Certification of calibration for the test instrument • Location of all probes used to develop the temperature map • Documentation of all test procedures Certificate of Calibration (Part No. QSF012) Helmer ensures the performance and accuracy of your refrigerator from the factory. A Certificate of Calibration for all instrumentation used to test and calibrate the refrigerator is available. This certificate validates that all instrumentation used in the testing protocol is calibrated to an NIST* traceable instrument. Remote Alarms RA1 (Part No. 500607-1)RA4 (Part No. 500608-1)Helmer alarms extend your existing system to remote locations in your facility. Two models are available. The RA1 offers monitoring of one device or zone and the RA4 provides monitoring of up to 4 devices or zones. Remote alarms are operational up to 3000 ft. away (wiring not included). Audible and visual signals indicate an alarm condition. The alarms are countertop, wall, or cabinet mountable and are compatible with devices featuring dry contact connections. They are AC powered with battery backup for full function during power failure. Available in 100-240V, 50-60Hz. * National Institute of Standards and Technology 10 Horizon Series unit shown with solid door. Ideal for storage of light-sensitive products. Remote Alarms EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. options & accessories options & accessories Temperature Chart Recorder i.Series (Part No. 400451-1) Horizon Series (Part No. 400452-1) 7-Day, 4” (10cm) inkless temperature chart recorder is factory installed. Includes battery backup and a supply of 52 charts. Chart Recorder Paper (Part No. 220366) 4” (10cm) diameter, -5 to +20º, package of 52 Access Ports Laboratory and Pharmacy refrigerators have one 1.75” (4.5cm) diameter access port with interior and exterior plugs provided standard. Port is centered on the left-hand side wall (when facing the unit). Additional Access Port with Plug (Part No. 400631-2) A second access port on the right-hand side wall can be added (factory installed, please specify when ordering refrigerator). Access ports are 1.75” (4.5cm) diameter with interior and exterior plugs. Custom Access Port with Plug (Part No. 400631-1) Specify location in the chamber at time of order. Access ports are 1.75” (4.5cm) diameter with interior and exterior plugs. Duplex Outlet (Part No. 400476-1) Duplex outlet is provided with vapor proof cover and 8 foot line cord. Duplex outlet power is independent from refrigerator power cord. Outlet is located on the interior back wall of the refrigerator. Limit 1 per refrigerator. (115V only) Floor and Wall Bracket Kit (Part No. 400472-1) Designed to secure your refrigerator to the building floor and/or wall. Refrigerator has factory threaded mounting holes. Heavy gauge, powder coated steel floor mounting brackets and cabinet anchor hardware are provided. Customer to provide floor and/or wall anchor hardware and onsite assembly. Chromatography Kit (Part No. 400706-1) For Chromatography applications. Factory installed on single and double door Laboratory Refrigerator models. Kit includes pole mast, vapor-proof duplex outlet, four half-sized shelves, and a second sidewall access port. Additional Pole Mast Available (Part No. 400478-1) Optional 0.5” (1.3cm) diameter pole mast can be easily repositioned in the chamber. 11 Temperature Chart Recorder Vapor Proof Duplex Outlet (115V only)Access Port (shown with line cord) Chart Paper Laboratory Refrigerator with Chromatography Kit EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. warranty 15425 Herriman Boulevard • Noblesville, IN 46060 USA Toll Free (U.S. and Canada): 800.743.5637 Phone: 1.317.773.9073 • Fax: 1.317.773.9082 Email: sales@helmerinc.com • www.helmerinc.com about helmer Established in 1977 to serve the life science market, Helmer is a manufacturer and worldwide distributor of high quality laboratory equipment and refrigerated products. We have combined our experience and innovation to bring you the most advanced line of laboratory and pharmacy refrigerators available today. Helmer refrigerators are exclusively manufactured at our headquarters in Noblesville, Indiana. Our products are available in the U.S. and Canada as well as through international distributors worldwide. For more information, please visit our website at www.helmerinc.com. We look forward to the opportunity to serve you. .series / rel. ™ plus Helmer backs all i.Series Laboratory and Pharmacy Refrigerators with the Rel.i PLUS warranty and i.Care™ support. Rel.i PLUS includes the following warranty for the U.S. and Canada: 7 Years Compressor 2 Years Parts 1 Year Labor horizon series / rel. ™ Helmer backs all Horizon Series Laboratory and Pharmacy Refrigerators with the Rel.i warranty and i.Care support: 5 Years Compressor 2 Years Parts 1 Year Labor With Helmer’s unique i.Care support, our professional service staff moves fast to assure you the best care you can receive. For more information on international warranties, please contact your local distributor. Blood Bank and Laboratory Refrigerators • Plasma Storage and Laboratory Freezers (-30ºC) Platelet Storage Systems • Plasma Thawing Systems • Cell Washing System • Hettich Centrifuges (U.S. only) i.Series® and i.Center® are registered trademarks of Helmer, Inc. in the United States of America Horizon Series™, i.Help™, Rel.i™, and i.Care™ are trademarks of Helmer, Inc. © 2007 Helmer Inc.380032-1 3/07 EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. HPR120 Pharmacy Refrigerator The HPR120 is a single door Horizon Series™ Pharmacy Refrigerator. It offers a microprocessor temperature controller with an alarm/monitor, superior cabinet construction, and maximum temperature uniformity with a heavy-duty, forced-air refrigeration system. The HPR120 comes standard with 6 solid, stainless steel drawers. The drawers have fully extendable slides, Scratch-Guard edge protectors, and liquid-tight construction. For maximum versatility, the HPR120 can be customized with a combination of optional half or full size shelves, stainless steel drawers, or roll out baskets. Features • Temperature Controller with Alarm/Monitor - LED digital display of chamber temperature - Programmable operating temperature range - Single temperature probe - Adjustable alarm volume and tone - Programmable high / low temperature alarms with visual and audible indicators - Manual alarm checks • Bacteria-resistant powder coated interior, exterior and door handle • Dual-pane glass door • Innovative Sure-Seal door system with magnetic closure • Access port with interior and exterior plugs • Dual, swivel locking casters • Key lock Warranty Interior Dimensions (w x hx d) 63cm x 148cm x 62cm Exterior Dimensions (w x h x d) 75cm x 201cm x 75cm Overall Exterior Dimensions (w x h x d) Includes door handle, electrical panel, & evaporation tray 75cm x 201cm x 83cm Interior Volume 572 liters / 20.2 cu ft Drawers 6 Solid Stainless Steel, Adjustable Electrical 115V 60Hz 7.5 FLA 230V 50Hz 4 FLA 230V 60Hz 4 FLA Net Weight 231 kg Certified to applicable UL and CSA standards by a NRTL EQUIP# REF03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. ,Use & Care Guide Manual de uso y cuidado Guide d’utilisation et d’entretien English / Español / Français Model/Modelo/Modèle: 106.6021*, 106.7021* Kenmore® Top Mount Refrigerator Refrigerador con congelador en la parte superior Réfrigérateur superposé * = color number, número de color, le numéro de la couleur P/N W10679320B Sears Brands Management Corporation Hoffman Estates, IL, U.S.A. 60179 www.kenmore.comwww.sears.com Sears Canada Inc.Toronto, Ontario, Canada M5B 2C3www.sears.ca EQUIP# REF05 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. EQUIP# REF05 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 6 Location Requirements IMPORTANT: This refrigerator is designed for indoor household use only. To ensure proper ventilation for your refrigerator, allow for ½" (1.25 cm) of space on each side and at the top. Allow for 1" (2.54 cm) of space behind the refrigerator. If your refrigerator has an ice maker, allow extra space at the back for the water line connections. When installing your refrigerator next to a fixed wall, leave a 2" (5.08 cm) minimum space on the hinge side (some models require more) to allow the door to swing open. NOTE: This refrigerator is intended for use in a location where the temperature ranges from a minimum of 55°F (13°C) to a maximum of 110°F (43°C). The preferred room temperature range for optimum performance, which reduces electricity usage and provides superior cooling, is between 60°F (15°C) and 90°F (32°C). It is recommended that you do not install the refrigerator near a heat source, such as an oven or radiator. Electrical Requirements Before you move your refrigerator into its final location, it is important to make sure you have the proper electrical connection. Recommended Grounding Method A 115 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord. NOTE: Before performing any type of installation or cleaning, or removing a light bulb, turn cooling off or turn the control (Thermostat, Refrigerator or Freezer Control depending on the model) to OFF, and then disconnect the refrigerator from the electrical source. When you are finished, reconnect the refrigerator to the electrical source and turn cooling on or reset the control (Thermostat, Refrigerator or Freezer Control depending on the model) to the desired setting. See “Using the Controls” in the User Instructions, User Guide, or Use & Care Guide. WARNING Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from refrigerator. Failure to do so can result in death, explosion, or fire. 1/2" (1.25 cm) 2" (5.08 cm) Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. WARNING EQUIP# REF05 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 7 Water Supply Requirements Read all directions before you begin. Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. TOOLS NEEDED: Flat-blade screwdriver, ⁷⁄₁₆" and ¹⁄₂" open-end wrenches or 2 adjustable wrenches, ¹⁄₄" nut driver and drill bit, cordless drill. IMPORTANT: ■If you turn the refrigerator on before the water line is connected, turn the ice maker OFF. ■All installations must meet local plumbing code requirements. ■Use copper tubing and check for leaks. Install copper tubing only in areas where the household temperatures will remain above freezing. NOTE: Your refrigerator dealer has a kit available with a ¹⁄₄" (6.35 mm) saddle-type shutoff valve, a union, and copper tubing. Before purchasing, make sure a saddle-type valve complies with your local plumbing codes. Do not use a piercing- type or ³⁄₁₆" (4.76 mm) saddle valve which reduces water flow and clogs more easily. Water Pressure IMPORTANT: A cold water supply with water pressure between 30 and 120 psi (207 and 827 kPa) is required to operate the ice maker. NOTE: If the water pressure is less than what is required, ice cubes could be hollow or irregular shaped. If you have questions about your water pressure, call a licensed, qualified plumber. Reverse Osmosis Water Supply If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis system needs to be a minimum of 40 to 60 psi (276 to 414 kPa). If the ice maker is still not operating properly: ■Check to see whether the sediment filter in the reverse osmosis system is blocked. Replace the filter if necessary. ■Allow the storage tank on the reverse osmosis system to refill after heavy usage. Connect the Water Supply Read all directions before you begin. IMPORTANT: If you turn the refrigerator on before the water line is connected, turn the ice maker OFF. Connect to Water Line 1.Unplug refrigerator or disconnect power. 2.Turn OFF main water supply. Turn ON nearest faucet long enough to clear line of water. 3.Locate a ½" to 1¹⁄₄" (1.25 cm to 3.18 cm) vertical cold water pipe near the refrigerator. IMPORTANT: ■Make sure it is a cold water pipe. ■Horizontal pipe will work, but drill on the top side of the pipe, not the bottom. This will help keep water away from the drill and normal sediment from collecting in the valve. 4.Determine the length of copper tubing you need. Measure from the connection on the lower left rear of refrigerator to the water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use ¹⁄₄" (6.35 mm) O.D. (outside diameter) copper tubing. Be sure both ends of copper tubing are cut square. 5.Using a cordless drill, drill a ¹⁄₄" hole in the cold water pipe you have selected. 6.Fasten the shutoff valve to the cold water pipe with the pipe clamp. Be sure the outlet end is solidly in the ¹⁄₄" drilled hole in the water pipe and that the washer is under the pipe clamp. Tighten the packing nut. Tighten the pipe clamp screws slowly and evenly so washer makes a watertight seal. Do not overtighten or you may crush the copper tubing. 7.Slip the compression sleeve and compression nut on the copper tubing as shown. Insert the end of the tubing into the outlet end squarely as far as it will go. Screw compression nut onto outlet end with adjustable wrench. Do not overtighten. 8.Place the free end of the tubing in a container or sink, and turn ON the main water supply. Flush the tubing until water is clear. Turn OFF the shutoff valve on the water pipe. Coil the copper tubing. A.Cold water pipe B.Pipe clamp C.Copper tubing D.Compression nut E.Compression sleeve F. Shutoff valve G. Packing nut A B C DEF G EQUIP# REF05 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 8 Connect to Refrigerator 1.Unplug refrigerator or disconnect power. 2.Attach the copper tubing to the valve inlet using a compression nut and sleeve as shown. Tighten the compression nut. Do not overtighten. 3.Use the tube clamp on the back of the refrigerator to secure the tubing to the refrigerator as shown. This will help avoid damage to the tubing when the refrigerator is pushed back against the wall. 4.Turn shutoff valve ON. 5.Check for leaks. Tighten any connections (including connections at the valve) or nuts that leak. 6.The ice maker is equipped with a built-in water strainer. If your water conditions require a second water strainer, install it in the ¹⁄₄" (6.35 mm) water line at either tube connection. Obtain a water strainer from your nearest appliance dealer. Complete the Installation 1.Plug into a grounded 3 prong outlet. NOTE: Allow 24 hours to produce the first batch of ice. Discard the first three batches of ice produced. Allow 3 days to completely fill ice container. Refrigerator Doors Tools Needed: IMPORTANT: ■Before you begin, turn the refrigerator control OFF. Unplug refrigerator or disconnect power. ■Remove food and adjustable door or utility bins from doors. ■If you are only removing and replacing the doors, see the “Remove Doors and Hinges” and “Replace Doors and Hinges” sections. ■A Reversibility Kit, which includes a new Brand Badge and hole covers, is available, if you wish to reverse the door swing. ■All graphics referenced in the following instructions are included later in this section after “Final Steps.” Remove Doors and Hinges ⁵⁄₁₆" Hex-head Hinge Screw 1.Unplug refrigerator or disconnect power. 2.Close the refrigerator door and keep both doors closed until you are ready to lift them free from the cabinet. NOTE: Provide additional support for the doors while the hinges are being moved. Do not depend on the door magnets to hold the doors in place while you are working. 3.Remove the parts for the top hinge as shown in Top Hinge graphic. Lift the freezer door free from the cabinet. 4.Remove the parts for the center hinge as shown in the Center Hinge graphic. Lift the refrigerator door free from the cabinet. 5.Remove base grille from the bottom front of the refrigerator. 6.Remove the parts for the bottom hinge as shown in the Bottom Hinge graphic. A.Tube clamp B.Tube clamp screw C.Copper tubing D.Compression nut E.Valve inlet A C B D E Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. WARNING ■⁵⁄₁₆" Hex-head socket wrench ■⁵⁄₁₆" Open-end wrench ■#2 Phillips screwdriver ■Flat 2" putty knife ■Flat-blade screwdriver EQUIP# REF05 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. REF4P ADA-Compatible Precision™ series medical-grade undercounter refrigerator Features Superior temperature performance - custom-designed microprocessor temperature controller - air-cooled refrigeration system with heavy duty 1/5 horsepower compressor - environmentally friendly, non-CFC R134a refrigerant - programmed automatic defrost every 8 hours - cabinet-wide temperature remains within +/- 1 C (1.8 F), even with frequent door openings Convenience and security - fits below 34.00" (86.4 cm) ADA countertops without casters - refrigeration system settings accessed through door-mounted controls - exterior LED digital temperature display available in user-programmable C or F with choice of product or air temperature - user-programmable audible and visual high/low alarms - lockable controller so set points cannot be inadvertently changed - dry (NO and NC) contacts for connection to remote alarm systems - flexible internal storage configuration (drawers and shelves interchangeable) - Agion® antimicrobial and UV product protection added to molded plastic façade1 Durability and serviceability - stainless steel construction on exterior and interior - two epoxy-coated wire shelves standard - back wall evaporator and front ventilation (no top, back or side clearance required) - heavy-duty edge-mount self-closing hinges - field-reversible door - integral handle and magnetic gasket door closure Warranty - 2 year parts and labor on refrigeration system - 5 year parts on compressor Job Item Undercounter refrigerators Controls Keypad Door configuration V/Hz/Ph Item number LED No stainless 115/60/1 REF4P-00-00 glass 115/60/1 REF4P-00-GD Yes stainless 115/60/1 REF4P-KP-00 glass 115/60/1 REF4P-KP-GD Options and accessories Glass door Keypad and electronic lock Extra shelf (item# 01059484) Drawer (item# 01053644) External digital data logger (item# 01057561) Replacement probe for digital data logger (item# 01057595) Temperature surveillance module (chart recorder) (item# 00168674) Replacement charts for temperature surveillance module (item# 00162099) Replacement pens for temperature surveillance module (item# 00162081) Universal automated medication dispensing system bracket (item# 01059096) Glycerine (16 oz) (item# 00959296) Stacking kit (item# 01054006) Temperature alarm (item# 00112185) 17.00" (43.18 cm) pedestal kit (item# 01059120) Extra key (item# 01059112) Casters (set of 4) (item# 01053636) Seismic bracket kit (item# 01059104) 801 Church Lane | Easton, PA 18040, USA 1.800.523.9361 | 1.610.252.7301 | follettice.com EQUIP# RFU05 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION REF4P undercounter refrigerator Form #6455 04/14 © 2014 Follett Corporation Specification Nominal capacity 3.9 cu ft (110 L) W1 Width exterior 23.75" (60.3 cm) D1 Depth cabinet 25.62" (65.1 cm) Depth with façade 27.00" (68.6 cm) H1 Height exterior 31.38" (79.7 cm) Height with casters 33.88" (86.1 cm) Width interior 19.75" (50.2 cm) Depth interior 18.32" (46.5 cm) Height interior 18.94" (48.1 cm) Ventilation clearance 0.0" for top, side and back clearance C1 115 V/60/1 electrical 4.1 run load amps, NEMA 5-15P 90º hospital-grade plug PVC, SJT, 16GA, 7' (2.1 m) cord Door solid, foamed stainless 21.50" x 22.51"x 1.63" (54.6 cm x 57.2 cm 4.0 cm) Optional glass door triple pane, low E glass window dimensions16.30" x 10.90" (41.4 cm x 27.7 cm) Door lock cylinder lock Door handle molded into front façade Door hinges edge-mount, self-closing Door swing field-reversible Storage system (2) 18.10" x 19.10" (46.0 cm x 48.5 cm) epoxy-coated steel shelves Gasket magnetic Temperature display standard 7 segment LED C2 3rd party probe access rear access port High and low product temperature alarm audible and visual, user programmable set points in C or F Factory set point and operating range preset at 4 C (40 F) with an adjustable range from 2 C to 10 C (36 F to 50 F) Probe error alarm audible and visual — product temperature probes, refrigeration and defrost Alarm mute user selectable Alarm volume 0 -10 adjustable Min/max temperature log shows highest and lowest product temperature since last reset occurred Product simulation bottle (1) 60 ml Remote contacts NO/NC standard, located on back Refrigerant and charge R134a refrigerant, 9 oz Energy consumption 1.8 kWh/day Max heat rejection 2185 BTU/hr Approximate ship weight 205 lb (93 kg) NOTE: For indoor use only 801 Church Lane | Easton, PA 18040, USA 1.800.523.9361 | 1.610.252.7301 | follettice.com Dimensional drawing 3.06 in (7.77 cm) 28.96 in (73.5 cm) 0.75 in (1.90 cm)5.81 in (14.757 cm) H1 C1 C2 W1 D1 SHORT FORM SPECIFICATION: Precision series undercounter refrigerator with choice of solid stainless steel or glass door fits under 34.00" (86.4 cm) ADA-height counter with 3.9 cubic feet (110 L) of nominal capacity. Includes (2) epoxy-coated wire shelves, adjustable in 1/2" increments. Environmentally responsible R134a forced-air cooled refrigeration system. Top-mounted controls display product or air temperature in user-selectable C or F. Integral high and low temperature alarming. Storage area to be insulated with CFC-free, high-density polyurethane foam. 7' (2.1 m) power cord with NEMA 5-15P 90º hospital-grade plug. NSF, UL and CUL listed. 1 Disclaimer: Antimicrobial protection is limited to the plastic façade. Agion is a registered trademark of Sciessent LLC. Precision is a trademark of Follett Corporation. Follett is a registered trademark of Follett Corporation, registered in the US. Follett reserves the right to change specifications at any time without obligation. Certifications may vary depending on country of origin. EQUIP# RFU05 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION Magic Chef 4.4 cu ft Refrigerator MCBR445W2 Brand: Magic Chef Model: MCBR445W2 Features: Push Button Defrost Feature Adjustable / Removable Glass Shelves Adjustable Leveling Legs Reversible Door Can Dispenser in Door & Clean Back Design Product Description Magic Chef 4.4 cu ft Refrigerator MCBR445W2 4.4 CuFt Push-button defrost Glass shelves Can dispenser Reversible door Extra door storage Vegetable crisper Full range temperature control Clear back Full width freezer compartment Dimensions - 18.9Wx33.8Hx20D - 68.3lbs- Power 120v, 50hz, 1 Phase EQUIP# RFU06 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Pyxis® Controlled substance management system Pyxis CIISafe™ system Single integrated main Single column auxiliary Double column auxiliaryDouble integrated main PC desktop solution Continued on next page External dimensions Equipment Doors/drawers Dimensions Notes Main Double integrated main 7 doors, 1 rapid access drawer 52” W x 28” D x 79.5” H 132.1 cm W x 71 cm D x 201.9 cm H Includes removable printer shelf; adds 18” to width if using shelf Single integrated main 3 doors, 1 rapid access drawer 31” W x 28” D x 79.5” H 78.7 cm W x 71.0 cm D x 201.9 cm H Includes removable printer shelf; adds 18” to width if using shelf PC desktop solution not applicable PC tower: 5” W x 12” D x 13” H 12.7 cm W x 30.48 cm D x 33.02 cm H Requires counter space for PC tower, monitor and printer Monitor: 16.1” W x 8.4” D x 19.5” H 40.89 cm W x 21.33 cm D x 49.53 cm H EQUIP# SAF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. © 2011 CareFusion Corporation or one of its subsidiaries. All rights reserved. CIISafe and Pyxis are trademarks or registered trademarks of CareFusion Corporation or one of its subsidiaries. DI2525-01 (0711/2000) CareFusion San Diego, CA carefusion.com Please refer to federal, state and local laws and regulations applicable to your hospital or pharmacy location in order to comply with specific requirements for the storage of controlled substances. Component specifications Equipment Description Touch screen Integral with graphics display, high-resolution resistive technology Display 10.4” (diagonal) TFT liquid crystal display (LCD), full color graphics capable (PC desktop has a 19” LCD monitor) Keyboard Standard PC keyboard, full-travel, reduced footprint; complete alphabet with numeric and control keys plus user-selectable 10-key function Eyebolt For security and locking cable Casters Two fixed and two pivoting Power and PC tower specifications Equipment AC power (line voltage)Peak power (watts)Heat evolved Single integrated main 100-240 V, 50-60 Hz 151 W 515 BTU Double integrated main 100-240 V, 50-60 Hz 172 W 587 BTU PC desktop solution 100-240 V, 50-60 Hz 68 W 215 BTU Auxiliaries Single column auxiliary 100-240 V, 50-60 Hz 53 W 181 BTU Double column auxiliary 100-240 V, 50-60 Hz 63 W 215 BTU Weight and construction specifications Equipment Weight Construction Single integrated main 369 lbs* 167.3 kg Doors, rear, side and interior panels constructed of 16-gauge sheet metal; support columns constructed of 14-gauge sheet metal Double integrated main 525.5 lbs* 238.1 kg Doors, rear, side and interior panels constructed of 16-gauge sheet metal; support columns constructed of 14-gauge sheet metal PC desktop solution 48 lbs, 21.7 kg Auxiliary Single column auxiliary 314 lbs* 142.4 kg Doors, rear, side and interior panels constructed of 16-gauge sheet metal; support columns constructed of 14-gauge sheet metal Double column auxiliary 470.5 lbs* 213.4 kg Doors, rear, side and interior panels constructed of 16-gauge sheet metal; support columns constructed of 14-gauge sheet metal Drawers/shelves Wire rack shelf 6.5 lbs, 2.9 kg Security shelf 7 lbs, 3.1 kg Drawer with slides 36 lbs, 16.3 kg Accessories Laser printer 22 lbs, 9.9 kg * Weight of shelving not included in the main and auxiliary weight. External dimensions (continued) Equipment Doors/drawers Dimensions Notes Auxiliaries Single column auxiliary 4 doors 31” W x 28” D x 79.5” H 78.7 cm W x 71.0 cm D x 201.9 cm H Double column auxiliary 8 doors 52” W x 28” D x 79.5” H 132.1 cm W x 71 cm D x 201.9 cm H Accessories Laser printer not applicable 16.6” W x 18.3” D x 15.9” H 42.16 cm W x 46.48 cm D x 40.38 cm H EQUIP# SAF01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Ò Item#_______________________________________________ Job _________________________________________________Wire ShelvingÒ InterMetro Industries Corporation North Washington Street Wilkes-Barre, PA 18705 www.metro.com Ò10.01SUPER ERECTA SHELF® WIRE SHELVING •Unique Design: The open wire design of these heavy-gauge carbon-steel or stainless steel shelves minimizes dust accumulation and allows a free circulation of air, greater visibility of stored items and greater light penetration. •Versatile Construction: Super Erecta Shelf®wire shelving can change as quickly as your needs change. By using various accessories, hundreds of shelving configurations become possible. •Fast, Secure Assembly: SiteSelect™Posts with the triple-groove visual guide feature, have circular grooves at 1" (25mm) intervals and are numbered at 2" (50mm) intervals. A patented, tapered split sleeve (plastic or aluminum) snaps together around each post. Tapered openings in the shelf corners slide over the tapered split sleeves providing a positive lock. Shelf is assembled in minutes without the use of any special tools. •Shelf Ribs: Run front to back, allowing you to slide items on and off shelves smoothly. •Shelf Accessibility: Shelves can be loaded/unloaded easily from all sides. This open construction allows use of maximum storage space of cube. •Adjustability: Shelves can be adjusted at 1” (25mm) intervals along the entire length of the post. •Durable: Super Erecta Shelf®wire shelving is available in four options: Super Erecta Brite™, chrome-plated, stainless steel and Metroseal™. •Adjustable Feet: Bolt levelers compensate for surface irregularities. Copyright © 1997 Metropolitan Wire Corp. FOR DESIGN PURPOSES ONLY NOT FOR CONSTRUCTION EQUIP# SHW02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Job____________________________________________ SUPER ERECTA SHELF® WIRE SHELVING Ò Manufactured by:Phone 717-825-2741 InterMetro Industries Corp.FAX 717-825-2852 North Washington Street For Product Information, call 1-800-433-2232 Wilkes-Barre, PA 18705 For Customer Service, call 1-800-992-1776 Ò InterMetro Industries Corporation North Washington Street Wilkes-Barre, PA 18705 www.metro.com L02-006 Rev. 3/98 BJ Printed in U.S.A. Information and specifications are subject to change without notice. Please confirm at time of order.Wire ShelvingÒ10.01WIRE SHELVES Split Sleeves SUPER ERECTA SHELF meets U.S. Government Specifications MIL-S- 40144E. PLATED SHELVING has clear protective coating. For load capacity guidelines, ask your InterMetro representative for a copy of “Helpful Hints.” Approx. Width Length Pkd. Wt. Cat. No. Cat. No. Cat. No. (in.) (mm) (in.) (mm) (lbs.) (kg) Super Erecta Brite Chrome Stainless________________________________________________________________________ 14 355 24 610 6 2.7 1424BR 1424NC 1424NS________________________________________________________________________ 14 355 30 760 7 3.2 1430BR 1430NC 1430NS________________________________________________________________________ 14 355 36 910 8 3.6 1436BR 1436NC 1436NS________________________________________________________________________ 14 355 42 1060 9 1/2 4.3 1442BR 1442NC 1442NS________________________________________________________________________ 14 355 48 1220 10 1/2 4.7 1448BR 1448NC 1448NS________________________________________________________________________ 14 355 60 1525 14 6.3 1460BR 1460NC 1460NS________________________________________________________________________ 14 355 72 1825 17 7.7 1472BR 1472NC 1472NS________________________________________________________________________ 18 455 24 610 7 3.2 1824BR 1824NC 1824NS________________________________________________________________________ 18 455 30 760 8 3.6 1830BR 1830NC 1830NS________________________________________________________________________ 18 455 36 910 9 1/2 4.3 1836BR 1836NC 1836NS______________________________________________________ ___________ 18 455 42 1060 11 5.0 1842BR 1842NC 1842NS________________________________________________________________________ 18 455 48 1220 12 5.4 1848BR 1848NC 1848NS________________________________________________________________________ 18 455 54 1370 14 1/2 6.6 1854BR 1854NC 1854NS________________________________________________________________________ 18 455 60 1525 17 7.7 1860BR 1860NC 1860NS________________________________________________________________________ 18 455 72 1825 20 9.1 1872BR 1872NC 1872NS________________________________________________________________________ 21 530 24 610 8 3.6 2124BR 2124NC 2124NS________________________________________________________________________ 21 530 30 760 9 4.1 2130BR 2130NC 2130NS________________________________________________________________________ 21 530 36 910 11 5.0 2136BR 2136NC 2136NS________________________________________________________________________ 21 530 42 1060 12 5.4 2142BR 2142NC 2142NS________________________________________________________________________ 21 530 48 1220 14 6.4 2148BR 2148NC 2148NS________________________________________________________________________ 21 530 54 1370 16 7.6 2154BR 2154NC 2154NS________________________________________________________________________ 21 530 60 1525 18 8.2 2160BR 2160NC 2160NS________________________________________________________________________ 21 530 72 1825 24 10.9 2172BR 2172NC 2172NS________________________________________________________________________ 24 610 24 610 9 4.1 2424BR 2424NC 2424NS________________________________________________________________________ 24 610 30 760 11 5.0 2430BR 2430NC 2430NS________________________________________________________________________ 24 610 36 910 13 5.9 2436BR 2436NC 2436NS________________________________________________________________________ 24 610 42 1060 15 6.8 2442BR 2442NC 2442NS________________________________________________________________________ 24 610 48 1220 16 7.3 2448BR 2448NC 2448NS________________________________________________________________________ 24 610 54 1370 18 8.6 2454BR 2454NC 2454NS________________________________________________________________________ 24 610 60 1525 21 9.5 2460BR 2460NC 2460NS________________________________________________________________________ 24 610 72 1825 26 11.8 2472BR 2472NC 2472NS________________________________________________________________________ NOTE For Metroseal shelving information see sheet No. 10.10. “S” Hooks Used to “add-on” shelving units with only two posts required. Cat. No. 9995Z SiteSelect™Posts Approx. Height* Pkd. Wt. Cat. No. Cat. No. (in.) (mm) (lbs.) (kg) Plated Stainless___________________________________________ 75/8 190 1/2 0.2 7P___________________________________________ 141/2 368 1 0.5 13P 13PS___________________________________________ 281/2 724 1 3/4 0.75 27P 27PS___________________________________________ 341/2 876 2 0.9 33P 33PS___________________________________________ 549/16 1386 3 1.4 54P 54PS___________________________________________ 629/16 1589 3 1/2 1.6 63P 63PS___________________________________________ 745/8 1895 4 1.8 74P 74PS___________________________________________ 865/8 2200 5 2.3 86P 86PS___________________________________________ *Height includes leveling bolt and cap. Important: When ordering by components remember that stability decreases as the ratio of height to width increases. Units should be kept as wide and low as poss ble. With 14” shelving, foot plates should be used and secured to the floor on free-standing units; on mobile units, maximum post height is 54”. SiteSelect™ Posts are grooved at 1" (25mm) increments and numbered at 2" (50mm) increments. Posts are triple- grooved every 8" (203mm) for easy identification. FOR DESIGN PURPOSES ONLY NOT FOR CONSTRUCTION EQUIP# SHW02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Mobile Stem Caster Cart Mobile Dolly Truck InterMetro Industries Corporation North Washington Street Wilkes-Barre, PA 18705 www.metro.com SUPER ADJUSTABLE 2™ SUPER ERECTA ShELf®Adjustable Wire ShelvingItem # ______________________________________________ Job ________________________________________________®® SUPER ADJUSTABLE 2™ SUPER ERECTA ShELf® WIRE ShELVING Super Adjustable 2™ Super Erecta Wire Shelving is the most advanced and innovative wire storage system available. The unique Corner Release System, which allows shelves to be adjusted quickly and easily without tools, has been re-engineered to provide increased rigidity. And Super Adjustable 2™ Shelving works in conjunction with the entire Super Erecta System of shelves and accessories. • Maximum Space Utilization: The Corner Release System encourages repositioning of shelves during initial assembly to reclaim wasted vertical space. In some cases, reclaimed vertical space will allow an extra shelving tier to be added to the storage unit resulting in a 25% increase in storage capacity! • Easily Assembled: The unique Corner Release System enables quick and easy repositioning of shelves during the initial set up to accommodate different package or container sizes. “Total Assembly” is complete only after the shelves are properly spaced to maximize storage. SiteSelect™ Posts, with the double-groove visual guide feature, have circular grooves at 1" (25mm) increments and are numbered at 2" (51mm) intervals to easily identify proper shelf locations. • Easily Adjustable: The unique shelf design and SiteSelect™ Posts enable “tool-free”, quick adjustment at 1" (25mm) increments along the entire height of the post. • Improved Rigidity: An enhanced Corner Release System has made Super Adjustable 2™ the most rigid, easily adjustable shelving system ever.• Strong: Super Adjustable 2™ shelves hold as much weight as traditional Super Erecta wire shelving. Stationary units hold a maximum of 2,000 lb. (910kg). Maximum weight capacity per shelf (48" [1219mm] or shorter = 800 lb. [364kg]; longer than 48" [1219mm] = 600 lb. [273kg])• Choice of Finishes: Super Adjustable 2™ Super Erecta shelving is available in a variety of finishes: Super Erecta Brite and chrome-plated for dry storage; Metroseal 3™ with antimicrobial product protection and stainless steel for corrosive environments; and attractive black epoxy for merchandising applications. Super Adjustable 2™ Advantage . . . Easily reposition Super Adjustable 2™ shelves during initial assembly to increase storage capacity by as much as 25%.10.01ADry Storage — Chrome or Super Erecta Brite™ *Microban® and he Microban® symbol are registered trademarks of the Microban Products company, Huntersville, nc. Corner Release System ® All Environments — Metroseal 3™ with *Microban® Antimicrobial Product Protection EQUIP# SHW03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION Job ________________________________________________ SUPER ADJUSTABLE 2™ SUPER ERECTA ShELf® WIRE ShELVING SUPER ADJUSTABLE 2™ SUPER ERECTA ShELf®Adjustable Wire Shelving®® Dimensions Super Adjustable 2™ Super Erecta Wire Shelving Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Shelf Width/Length Approx. Pkd. Wt. Super Erecta Brite Chrome Metroseal 3 Stainless Black (in.) (mm) (lbs.) (kg) A1424BR A1424NC A1424NK3 A1424NS A1424NBL 14x24 355x610 6 2.7 A1430BR A1430NC A1430NK3 A1430NS A1430NBL 14x30 355x760 7 3.2 A1436BR A1436NC A1436NK3 A1436NS A1436NBL 14x36 355x914 8 3.6 A1442BR A1442NC A1442NK3 A1442NS A1442NBL 14x42 355x1066 91/2 4.3 A1448BR A1448NC A1448NK3 A1448NS A1448NBL 14x48 355x1219 101/2 4.7 A1460BR A1460NC A1460NK3 A1460NS A1460NBL 14x60 355x1524 14 6.3 A1472BR A1472NC A1472NK3 A1472NS A1472NBL 14x72 355x1825 17 7.7 A1824BR A1824NC A1824NK3 A1824NS A1824NBL 18x24 457x610 7 3.2 A1830BR A1830NC A1830NK3 A1830NS A1830NBL 18x30 457x760 8 3.6 A1836BR A1836NC A1836NK3 A1836NS A1836NBL 18x36 457x914 91/2 4.3 A1842BR A1842NC A1842NK3 A1842NS A1842NBL 18x42 457x1066 11 5.0 A1848BR A1848NC A1848NK3 A1848NS A1848NBL 18x48 457x1219 12 5.4 A1854BR A1854NC A1854NK3 A1854NS A1854NBL 18x54 457x1370 141/2 6.6 A1860BR A1860NC A1860NK3 A1860NS A1860NBL 18x60 457x1524 17 7.7 A1872BR A1872NC A1872NK3 A1872NS A1872NBL 18x72 457x1825 20 9.1 A2124BR A2124NC A2124NK3 A2124NS A2124NBL 21x24 530x610 8 3.6 A2130BR A2130NC A2130NK3 A2130NS A2130NBL 21x30 530x760 9 4.1 A2136BR A2136NC A2136NK3 A2136NS A2136NBL 21x36 530x914 11 5.0 A2142BR A2142NC A2142NK3 A2142NS A2142NBL 21x42 530x1066 12 5.4 A2148BR A2148NC A2148NK3 A2148NS A2148NBL 21x48 530x1219 14 6.4 A2154BR A2154NC A2154NK3 A2154NS A2154NBL 21x54 530x1370 16 7.3 A2160BR A2160NC A2160NK3 A2160NS A2160NBL 21x60 530x1524 18 8.2 A2172BR A2172NC A2172NK3 A2172NS A2172NBL 21x72 530x1825 24 10.9 A2424BR A2424NC A2424NK3 A2424NS A2424NBL 24x24 610x610 9 4.1 A2430BR A2430NC A2430NK3 A2430NS A2430NBL 24x30 610x760 11 5.0 A2436BR A2436NC A2436NK3 A2436NS A2436NBL 24x36 610x914 13 5.9 A2442BR A2442NC A2442NK3 A2442NS A2442NBL 24x42 610x1066 15 6.8 A2448BR A2448NC A2448NK3 A2448NS A2448NBL 24x48 610x1219 16 7.3 A2454BR A2454NC A2454NK3 A2454NS A2454NBL 24x54 610x1370 18 8.6 A2460BR A2460NC A2460NK3 A2460NS A2460NBL 24x60 610x1524 21 9.5 A2472BR A2472NC A2472NK3 A2472NS A2472NBL 24x72 610x1825 26 11.8 A3036NC A3036NK3 A3036NS 30x36 760x914 15 6.8 A3048NC A3048NK3 A3048NS 30x48 760x1219 21 9.5 A3060NC A3060NK3 A3060NS 30x60 760x1524 261/2 11.8 A3072NC A3072NK3 A3072NS 30x72 760x1829 31 14.0 A3636NC A3636NK3 A3636NS 36x36 910x914 18 8.2 A3648NC A3648NK3 A3648NS 36x48 910x1219 23 10.4 A3660NC A3660NK3 A3660NS 36x60 910x1524 29 13.1 A3672NC A3672NK3 A3672NS 36x72 910x1829 341/2 15.4 NOTE Microban® protects the Metroseal 3 coating from bacteria, mold, mildew and fungi that cause odors, stains and product degradation. For Metroseal 3 shelving information see sheet #10.10a.10.01AL02-006A Printed in U.S.A. Rev. 1/06 Information and specifications are subject to change without notice. Please confirm at time of order. Copyright © 2006 InterMetro Industries Corp. ®InterMetro Industries Corporation North Washington Street, Wilkes-Barre, PA 18705 Phone: 570-825-2741 • fax: 570-825-2852 for Product Information Call: 1-800-433-2232 All Metro Catalog Sheets are available on our Web Site: www.metro.com SiteSelect™ Posts STATIoNARy MoBILE† Approx. height* Cat. No. Cat. No. Cat. No. Cat. No. height* Cat. No. Cat. No. Cat. No. Cat. No. Pkd. Wt. (in.) (mm) Plated Metroseal 3 Stainless Black (in.) (mm) Plated Metroseal 3 Stainless Black (lbs.) (kg) 71/2 191 7P 7PBL 1/2 0.3 141/2 370 13P 13PK3 13PS 13PBL 1 0.5 271/2 700 27P 27PS 27PBL 271/2 699 27UP 27UPS 13/4 0.75 341/2 875 33P 33PK3 33PS 33PBL 337/8 861 33UP 33UPK3 33UPS 33UPBL 2 0.9 549/16 1385 54P 54PK3 54PS 54PBL 54 1370 54UP 54UPK3 54UPS 54UPBL 3 1.4 629/16 1590 63P 63PK3 63PS 63PBL 62 1575 63UP 63UPK3 63UPS 63UPBL 31/2 1.6 70 1778 70UPK3 33/4 1.7 745/8 1895 74P 74PK3 74PS 74PBL 74 1880 74UP 74UPK3 74UPS 74UPBL 4 1.8 865/8 2200 86P 86PK3 86PS 86PBL 86 2185 86UP 86UPK3 86UPS 86UPBL 4.5 2.0 965/8 2454 **96P 1/2 2.5 * height includes leveling bolt and cap. ** 96P should not be used in units less than 24" (610mm) deep. Consult Metro Engineering for alternate recommendations. Post lengths to be specified as cut to a round number, ie: 74P cut to 69"...This will result in an overall post height with adjustment of 693/8 to 697/8. † Mobile posts come without leveling bolt assembly to accommodate stem casters. Important: When ordering by components remember that for maximum stability, units should be kept as wide and low as possible. Replacement Parts Each kit includes components for one original Super Adjustable or Super Adjustable 2 shelf; (4) wedges, (4) sleeves, (4) shelf releases. Cat. No. SAKITA2 EQUIP# SHW03 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION Standard Features • 4" (10 cm) Ultra Comfort Mattress with sealed seams • 8" (20 cm) Omni Surface™ casters with wheel covers • 26" (66 cm) wide patient surface • Dual cylinder pneumatic backrest • Dual pedestal hydraulics with constant rate descent • Dual side-mounted foot control hydraulics • Retractable fifth-wheel steering • Four-wheel,steel-ring brakes with dual side and head activators • Glideaway™ siderails • Integrated storage tray with oxygen bottle holder • Permanently-attached folding foot section • Permanently-attached foot supports • Pop-up push handles • Roller bumpers • Three IV receptacles • Unique one-handed foot section release lever Gynnie® OB/GYN Stretcher Medical Specifications • Model Number 1061 • Overall Length 81.5" (207 cm) • Overall Width Siderails Up 31.5" (80 cm) Siderails Down 26.75" (68 cm) • Weight Capacity 500 lbs (228 kg) • Height Range (to litter top) High 36" (91 cm) Low 22.5" (57 cm) • Litter Positioning Backrest 0° - 90° Foot Section 0° - 90° Trend./Reverse Trend. ±18° • Patient Surface 26" x 77" (66 x 196 cm) • Siderails 13" x 39" (34 x 99 cm) • Caster Diameter 8" (20 cm) Stryker reserves the right to change specifications without notice. Warranty • One year parts,labor and travel or two years parts 3800 E. Centre Ave. Portage, MI 49002 t: 269 329 2100 f: 269 329 2311 toll free: 800 787 9537 www.stryker.com • C-spine cassette film holder • Calf supports and brackets • Defibrillator tray/footboard/extender • Backrest X-ray cassette holder • Hoop for drainage basin • IV caddy • IV poles • Permanent folding two- or three-stage • Tethered • Standard removable • Patient restraints • Serving/instrument tray • Siderail pads • Upright oxygen bottle holder • Extended warranty available Copyright © 2005 Stryker LSS-455-10D PC/SCG-7.5M-0306 Mkt Lit-70-01262005 Rev D Optional Features EQUIP# STR04 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. 222 High-Low Power Examination Table EQUIP# TBL01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. Ritter 222 SPECIFICATIONS Ritter 222 High-Low Power Exam Table Specifications Dimensions (top): 26.5" W x 57.5" L (67.3 x 146.1 cm) Length with footrest extended: 74.5" (189.2 cm) Height: Minimum 18" (45.7 cm) Maximum 37" (94.0 cm) Patient Load Rating 400# (181 kg) Paper roll holder (hidden): Holds 21" x 3.5" paper roll (45.7 x 8.9 cm) Options Seamless upholstery top 26.5" W x 57.5" L (67.3 x 146.1 cm) Cut and sewn, economy upholstery top 26.5" W x 57.5" L (67.3 x 146.1 cm) Pelvic tilt (5 degrees) Drawer heater (40 watt) Electrical receptacle (115 VAC 5 AMPS Max.) Duplex, hospital grade, electrical receptacle on left side Accessories Rear storage pod (includes removable divider) 17.8" x 7.0" x 9.8" high (45.2 x 17.8 x 24.8 cm high) Colors Five Ritter upholstery colors: Iris Blue, Nile Green, Terra Rosa, Royal Lavender, Pebble Grey Adjustable arm system (right and left side arms included) Factory installed only Knee crutches Armboard Procto rest Welch Allyn®light bracket Urology pan Stainless steel pan Side rails Electrical 115 VAC, 50/60 Hz, 5.5 AMPS (basic unit –001 & 005) 115 VAC, 50/60 Hz, 6 AMPS (with heater –003 & 007) UL 2601-1 and Can/CSA 601.1-M90 CE Mark 115 VAC, 50/60 Hz, 10.5 AMPS (with receptacle –002 & –006) 115 VAC, 50/60 Hz, 11 AMPS (with heater & receptacle –004 & –008) UL 544 and Can/CSA 22.2, 125-M1984 CE Mark 230 VAC, 50/60 Hz, 2.75 AMPS (basic unit –009) 230 VAC, 50/60 Hz, 3.00 AMPS (with heater –010) CE Mark © Midmark Corporation 2002 Products subject to improvement changes without notice. Litho in U.S.A. Industry code 0251 007-0344-00 9/02 ISO 9001 Certified For more information or a demonstration, contact your Ritter or Midmark dealer, or contact Midmark Corporation, Versailles, Ohio. Call: 1-800-643-6275 Fax: 1-800-365-8631 midmark.com Ritter 222 High-Low Power Examination Table Features Unprecedented low and high posi- tioning heights, counterbalanced, gas spring assisted back section assists in placing the back in an infinite number of positions, easy access backrest mechanism, built-in pillow, hideaway stirrups that pull out to lock in one of four lateral positions, foot extension shelf to expand the table to its fullest length, paper roll holder hidden under the headrest, storage for four 21" x 3.5" diameter paper rolls, polystyrene treatment pan, Exam Assistant Drawer System™ and leveling screws The Ritter 222’s unique arm system accessory gives your patients a stable platform to assist them in getting onto the table. EQUIP# TBL01 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION. REF: 4012 TM-1 Electric Lotion Warmer (110 V only) TM-1 Electric Lotion Warmer (110 V only) Table Mounted - Holds up to 6 (4 oz.) bottles. Keeps massage lotion and ultrasound gel at a comfortable temperature. Easily attaches to any treatment table or wall. Mini-Lotion Warmer hangs on the front of the Hydrocollator E-1 or E-2 heating units. (Bottles not included) Mains Power: 110~120 V 50/60 Hz Power Consumption: 1000W Weight: 15 lb (7 kg) Shipping Weight: 21 lb (8 kg) Dimensions: 13”L x 8”W x 16”H (33 cm x 20 cm x 41 cm) Electrical Safety Class: Class 1, Type B Safety Tests: UL 544 (US units only) CAN C 22-2, No. 601-1-M90 w/A2 HVAC: 51BTU/HR. BUT’S VARY 5%-10% ELECTRICAL: 1.3AMPS FOR DESIGN PURPOSES ONLY NOT FOR CONSTRUCTION EQUIP# WRM02 FOR DESIGN PURPOSES ONLY. NOT FOR CONSTRUCTION