Loading...
HomeMy WebLinkAboutB17-0092_E-301-1_1508947648.pdf2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/10/2017 1:47:39 PM15924.00 E-301.1 ELECTRICAL PANEL SCHEDULES 07/11/17PERMIT RESUBMISSION EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 122 A K Kitchen 4320 VA 90.00% 3888 VA Total Demand Load: 44033 VA G General 7360 VA 100.00% 7360 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 173 A M Motor 624 VA 125.00% 780 VA Total Connected Load: 62504 VA R Receptacle 47660 VA 60.49% 28830 VA L Lighting 2540 VA 125.00% 3175 VA Power Factor: 1 Load Type Connected Load Demand Factor Demand Load Panel Totals Phase Balance: 20 % A-B 17 % B-C 2 % C-A Total Amps: 188 A 157 A 184 A Total Load: 22120 VA 18780 VA 21604 VA 83 HEAT TAPE OB GUTTER -- 20 A 1 0 VA 0 VA 1 20 A -- HEAT TAPE OB GUTTER 84 81 HEAT TAPE OB GUTTER -- 20 A 1 0 VA 0 VA 1 20 A -- HEAT TAPE OB GUTTER 82 1 79 FA EXTENDER G 20 A 1 200 VA 0 VA 1 20 A -- Spare 80 1 77 CAMERA POWER R 20 A 1 180 VA 180 VA 1 20 A R L-111,112,113 78 1 1 75 RAY DAMPERS G 20 A 1 200 VA 360 VA 1 20 A R R-SERVER RM 113 76 1 73 Spare -- 20 A 1 0 VA 1080 VA 1 20 A R R-SERV RM 111,112,113 74 1 71 4640 VA 0 VA 1 20 A -- Spare 72 69 5000 VA 500 VA 1 20 A R R-CARDIO STRESS... 70 12 67 NEW PANEL 'NL1D' R; G; L 100 A 3 5960 VA 0 VA 1 20 A -- Spare 68 2 65 R-OFFICE R 20 A 1 1260 VA 360 VA 1 20 A R R-PT TREADMILL 66 1 1 63 R-BREAK ROOM DISP K 20 A 1 1620 VA 300 VA 1 20 A G R-CARDIO TECH WORK 64 1 61 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 62 1 59 PRE-ACTION COMP. M 20 A 1 624 VA 0 VA 1 20 A -- Spare 60 2 57 R-OFFICE R 20 A 1 900 VA 0 VA 1 20 A -- Spare 58 1 55 R-MRI CONTROL ROOM R 20 A 1 900 VA 360 VA 1 20 A R R-STORAGE 56 2 2 53 R-OFFICE COPIER G 20 A 1 1000 VA 540 VA 1 20 A R R-STORAGE 54 2 2 51 R-OFFICE R 20 A 1 1080 VA 720 VA 1 20 A R R-CARDIO CLEAN CHG 52 1 2 49 R-OFFICE R 20 A 1 1260 VA 720 VA 1 20 A R R-CARDIO CLEAN CHG 50 1 2 47 R-OFFICE R 20 A 1 540 VA 1080 VA 1 20 A R R-CARDIO TECH WORK 48 1 1 45 R-BREAK ROOM R 20 A 1 540 VA 540 VA 1 20 A R R-CARDIO CORRIDOR 46 1 1 43 R-BRK MICROWAVE K 20 A 1 1500 VA 360 VA 1 20 A R R-CARDIO ABG ROOM 44 1 1 41 R-BRK REF K 20 A 1 1200 VA 720 VA 1 20 A R R-CARDIO RECEPTION 42 1 1 39 MAG DOOR HOLDERS G 20 A 1 0 VA 360 VA 1 20 A R R-CORR/STAFF RECESS 40 2 1 37 R-SHF WORK ROOM R 20 A 1 540 VA 0 VA 1 20 A -- Spare 38 1 35 R-SHF OFFICE NORTH R 20 A 1 360 VA 540 VA 1 20 A R R-CARDIO OFFICE 36 1 2 33 R-CONF ROOM - A/V R 20 A 1 360 VA 540 VA 1 20 A R R-ULTRASOUND 34 2 2 31 R-COPIER G 20 A 1 1000 VA 180 VA 1 20 A R R-CARDIO CONTROL RR 32 1 2 29 R-OFFICE/COPY R 20 A 1 540 VA 360 VA 1 20 A R CARDIO CNTL CHG 30 1 1 27 R-PRE-OP CHECK IN R 20 A 1 720 VA 360 VA 1 20 A R CARDIO CNTL CHG 28 1 1 25 R-PRE-OP CHECK IN R 20 A 1 720 VA 0 VA 1 20 A -- Spare 26 1 23 R-MRI MECH ROOM R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 24 1 21 R-SHF CORRDIOR R 20 A 1 900 VA 720 VA 1 20 A R R-STORAGE 22 2 2 19 R-CONFERENCE ROOM R; G 20 A 1 560 VA 1440 VA 1 20 A R R-CARDIO CONTROL 20 1 1 17 R-SHF OFFICES R 20 A 1 900 VA 1080 VA 1 20 A R R-OFFICE 18 2 15 0 VA 900 VA 1 20 A R R-OFFICE 16 21 13 PANEL 'MRI' R; G 50 A 2 1360 VA 920 VA 1 20 A R; G R-SHF BIOMECH... 14 1 1 11 L-MRI L 20 A 1 1540 VA 900 VA 1 20 A R R-OFFICE 12 2 1 9 R-SHF OFFICES R 20 A 1 900 VA 180 VA 1 20 A R R-SHF BIOMECH... 10 1 1 7 R-SHF OFFICES R 20 A 1 720 VA 720 VA 1 20 A R R-SHF OFFICES 8 1 1 5 R-SHF OFFICE, VISITOR R 20 A 1 1440 VA 540 VA 1 20 A R R-SHF OFFICES 6 1 1 3 R-SHF OFFICE, RR R 20 A 1 540 VA 540 VA 1 20 A R R-SHF OFFICES 4 1 1 1 R-SHF RECEPTION R 20 A 1 540 VA 1080 VA 1 20 A R R-OFFICE 2 2 Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note 1. EXISTING LOAD 2. NEW LOAD Circuit Notes: Enclosure: Type 1 MCB Rating: 200 A Mounting: Surface Wire: 4 Bus Rating: 200 A Supply From: Phase: 3 Mains Type: MLO Location: Voltage: 120/208 Wye A.I.C. Rating: 10,000 Panel L1E EXISTING General Notes: O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 42 A K Kitchen 0 VA 0.00% 0 VA Total Demand Load: 15180 VA G General 3260 VA 100.00% 3260 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 43 A M Motor 0 VA 0.00% 0 VA Total Connected Load: 15600 VA R Receptacle 11340 VA 94.09% 10670 VA L Lighting 1000 VA 125.00% 1250 VA Power Factor: 1 Load Type Connected Load Demand Factor Demand Load Panel Totals Phase Balance: 19 % A-B 9 % B-C 30 % C-A Total Amps: 50 A 42 A 39 A Total Load: 5960 VA 5000 VA 4640 VA 41 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 42 39 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 40 37 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 38 35 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 36 33 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 34 1 31 R-CT HALL BATH R 20 A 1 180 VA 0 VA 1 20 A -- Spare 32 1 29 R-S.H. VISUAL OFFICE R 20 A 1 900 VA 0 VA 1 20 A -- Spare 30 1 27 R-CT R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 28 1 25 L-CT L 20 A 1 250 VA 0 VA 1 20 A -- Spare 26 1 23 L-CT L 20 A 1 250 VA 0 VA 1 20 A -- Spare 24 21 500 VA 0 VA 1 20 A -- Spare 22119 SYSCO SWITCH ED TELE G 20 A 2 500 VA 0 VA 1 20 A -- Spare 20 1 17 R-CT R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 18 1 15 R-CT R 20 A 1 1080 VA 0 VA 1 20 A -- Spare 16 1 13 L-DR. LOUNGE L 20 A 1 250 VA 200 VA 1 20 A G R-NUC. MED - PRINTER 14 1 11 L-STORAGE L 20 A 1 250 VA 540 VA 1 20 A R R-NUC. MED - CONTROL 12 9 R-OFFICE R 20 A 1 720 VA 180 VA 1 20 A G R-NUC. MED - COMP. 10 7 R-OFFICE R; G 20 A 1 1280 VA 1680 VA 1 20 A G R-NUC. MED - MICRO 8 5 R-OFFICE R 20 A 1 720 VA 900 VA 1 20 A R R-NUC. MED - HOT LAB 6 3 R-OFFICE R 20 A 1 720 VA 720 VA 1 20 A R R-NUC. MED 4 1 R-OFFICE R 20 A 1 720 VA 900 VA 1 20 A R R-NUC. MED 2 Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note 1. REFED FROM PANEL 'PB' Circuit Notes: Enclosure: Type 1 Mounting: Surface Wire: 4 Bus Rating: 100 A Supply From: L1E Phase: 3 Mains Type: MLO Location: Voltage: 120/208 Wye A.I.C. Rating: 10,000 Panel NL1D EXISTING General Notes: O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 116 A K Kitchen 3000 VA 100.00% 3000 VA Total Demand Load: 96203 VA G General 35277 VA 100.00% 35277 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 141 A M Motor 0 VA 0.00% 0 VA Total Connected Load: 117410 VA R Receptacle 61320 VA 58.15% 35660 VA L Lighting 17813 VA 125.00% 22266 VA Power Factor: 1 Load Type Connected Load Demand Factor Demand Load Panel Totals Phase Balance: 18 % A-B 12 % B-C 5 % C-A Total Amps: 132 A 155 A 139 A Total Load: 36501 VA 42766 VA 38143 VA -- 41 Space -- -- -- 0 VA 33665... 42 -- 39 Space -- -- -- 0 VA 36751... 40 -- 37 Space -- -- -- 0 VA 29373... 3 20 A R; K; G; L PANEL 'NL1A' VIA XFMR 38 1 -- 35 Space -- -- -- 0 VA 0 VA -- -- -- Space 36 -- -- 33 Space -- -- -- 0 VA 0 VA -- -- -- Space 34 -- -- 31 Space -- -- -- 0 VA 0 VA -- -- -- Space 32 -- -- 29 Space -- -- -- 0 VA 0 VA -- -- -- Space 30 -- -- 27 Space -- -- -- 0 VA 0 VA -- -- -- Space 28 -- -- 25 Space -- -- -- 0 VA 0 VA -- -- -- Space 26 -- -- 23 Space -- -- -- 0 VA 0 VA -- -- -- Space 24 -- -- 21 Space -- -- -- 0 VA 0 VA -- -- -- Space 22 -- -- 19 Space -- -- -- 0 VA 0 VA -- -- -- Space 20 -- -- 17 Space -- -- -- 0 VA 0 VA -- -- -- Space 18 -- -- 15 Space -- -- -- 0 VA 0 VA -- -- -- Space 16 -- -- 13 Space -- -- -- 0 VA 0 VA -- -- -- Space 14 -- -- 11 Space -- -- -- 0 VA 439 VA 1 20 A L L-PHARMACY 12 2 1 9 L-ENTRY/CORRIDORS L 20 A 1 1523 VA 286 VA 1 20 A L L-NUC MED 10 2 1 7 L-STOR/REST/ELEC L 20 A 1 333 VA 2511 VA 1 20 A L L-ADMIN 8 2 1 5 L-LABS L 20 A 1 1589 VA 2450 VA 1 20 A L L-EXAM/MRI 6 1 1 3 L-OFFICES/CONF/BRK L 20 A 1 1756 VA 2450 VA 1 20 A L L-LOBBY/CORR 4 1 1 1 L-PT ENT/GYM/TRTMNT L 20 A 1 1834 VA 2450 VA 1 20 A L L-GYM/CARDIO 2 1 Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note 1. EXISTING LOAD 2. NEW LOAD Circuit Notes: Enclosure: Type 1 Mounting: Surface Wire: 4 Bus Rating: 125 A Supply From: Phase: 3 Mains Type: MLO Location: Voltage: 480/277 Wye A.I.C. Rating: 18,000 Panel NH1A EXISTING General Notes: O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 33 A K Kitchen 0 VA 0.00% 0 VA Total Demand Load: 11947 VA G General 8497 VA 100.00% 8497 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 32 A M Motor 1176 VA 125.00% 1470 VA Total Connected Load: 11653 VA R Receptacle 1980 VA 100.00% 1980 VA L Lighting 0 VA 0.00% 0 VA Power Factor: 1 Load Type Connected Load Demand Factor Demand Load Panel Totals Phase Balance: 78 % A-B 163 % B-C 47 % C-A Total Amps: 33 A 19 A 49 A Total Load: 3761 VA 2240 VA 5652 VA 41 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 42 39 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 40 37 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 38 1 35 FA POWER EXTEND G 20 A 1 500 VA 0 VA 1 20 A -- Spare 36 33 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 34 31 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 32 29 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 30 27 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 28 25 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 26 1 23 MRI EXHAUST FAN M 20 A 1 1176 VA 0 VA 1 20 A -- Spare 24 21 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 22 19 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 20 2 17 R-PHARMACY... G 20 A 1 1000 VA 0 VA 1 20 A -- Spare 18 2 15 R-PHARMACY PRINTER G 20 A 1 500 VA 0 VA 1 20 A -- Spare 16 2 13 R-PHARMACY REF G 20 A 1 900 VA 540 VA 1 20 A R R-PHARMACY DESK 14 2 2 11 R-PHARMACY REF G 20 A 1 900 VA 516 VA 1 20 A G R-PHARMACY HOOD 12 2 2 9 R-PHARMACY PRINTER G 20 A 1 200 VA 540 VA 1 20 A R R-FACP ROOM 10 1 2 7 R-PHARMACY WRK... R 20 A 1 900 VA 516 VA 1 20 A G R-PHARMACY HOOD 8 2 1 5 R-PHARMACY REFER. G 20 A 1 600 VA 960 VA 1 20 A G R-PHARMACY UC... 6 2 1 3 R-PHARMACY PRINTER G 20 A 1 400 VA 600 VA 1 20 A G R-PHARMACY UC REF 4 2 1 1 R-PHARMACY... G 20 A 1 700 VA 205 VA 1 20 A G R-PHARMACY PYXIS 2 2 Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note 1. EXISTING LOAD 2. NEW LOAD Circuit Notes: Enclosure: Type 1 Mounting: Surface Wire: 4 Bus Rating: 100 A Supply From: Phase: 3 Mains Type: MLO Location: Voltage: 120/208 Wye A.I.C. Rating: 10,000 Panel EL1C EXISTING General Notes: O Other 0 VA 0.00% 0 VA E Existing 0 VA 0.00% 0 VA Total Demand Current: 20 A K Kitchen 1800 VA 90.00% 1620 VA Total Demand Load: 16944 VA G General 13524 VA 100.00% 13524 VA C Continuous 0 VA 0.00% 0 VA Total Connected Current: 20 A M Motor 0 VA 0.00% 0 VA Total Connected Load: 16908 VA R Receptacle 720 VA 100.00% 720 VA L Lighting 864 VA 125.00% 1080 VA Power Factor: 1 Load Type Connected Load Demand Factor Demand Load Panel Totals Phase Balance: 53 % A-B 24 % B-C 23 % C-A Total Amps: 17 A 25 A 20 A Total Load: 4573 VA 6846 VA 5489 VA -- 41 Space -- -- -- 0 VA 5256 VA 42 -- 39 Space -- -- -- 0 VA 6432 VA 40 -- 37 Space -- -- -- 0 VA 4356 VA 3 45 A R; K; G PANEL 'CL1A' VIA XFMR 38 1 -- 35 Space -- -- -- 0 VA 0 VA -- -- -- Space 36 -- -- 33 Space -- -- -- 0 VA 0 VA -- -- -- Space 34 -- -- 31 Space -- -- -- 0 VA 0 VA -- -- -- Space 32 -- -- 29 Space -- -- -- 0 VA 0 VA -- -- -- Space 30 -- -- 27 Space -- -- -- 0 VA 0 VA -- -- -- Space 28 -- -- 25 Space -- -- -- 0 VA 0 VA -- -- -- Space 26 -- -- 23 Space -- -- -- 0 VA 0 VA -- -- -- Space 24 -- -- 21 Space -- -- -- 0 VA 0 VA -- -- -- Space 22 -- -- 19 Space -- -- -- 0 VA 0 VA -- -- -- Space 20 -- -- 17 Space -- -- -- 0 VA 0 VA -- -- -- Space 18 -- -- 15 Space -- -- -- 0 VA 0 VA -- -- -- Space 16 -- -- 13 Space -- -- -- 0 VA 0 VA -- -- -- Space 14 -- -- 11 Space -- -- -- 0 VA 0 VA -- -- -- Space 12 -- -- 9 Space -- -- -- 0 VA 0 VA -- -- -- Space 10 -- -- 7 Space -- -- -- 0 VA 0 VA -- -- -- Space 8 -- 2 5 L-PHARMACY L 20 A 1 233 VA 0 VA 1 20 A -- Spare 6 2 3 L-ULTRASND/NUC MED L 20 A 1 414 VA 0 VA 1 20 A -- Spare 4 1 1 L-ELEC/IT L 20 A 1 217 VA 0 VA 1 20 A -- Spare 2 Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note 1. EXISTING LOAD 2. NEW LOAD Circuit Notes: Enclosure: Type 1 Mounting: Surface Wire: 4 Bus Rating: 100 A Supply From: Phase: 3 Mains Type: MLO Location: Voltage: 480/277 Wye A.I.C. Rating: 10,000 Panel CH1A EXISTING 1 1 1 2 ADDENDUM 1 05/23/2017 1 ADDENDUM 3 06/27/2017 2 10/25/17