HomeMy WebLinkAboutB17-0092_E-401-1_1508947650.pdfSINGLE GANG PLASTER RING WITH GROUND SCREW AND PIGTAIL TO MATCH DRYWALL THICKNESS 4" SQ COMBO BOX NO SCALE 16135.3 RECEPTACLE BOX SUPPORT DETAIL TOP OF CABINET TOP OF CABINET 80" (6'-8") OR 6" BELOW CEILING WHICHEVER IS LOWER 84" (7'-0") UON96" (8'-0") UON72" (6'-0") UON78" (6'-6") UON48" (4'-0") UON64" (5'-4") UONTYPICAL 9'-0" CEILING OR HIGHER TOP OF CABINET TYPICAL 8'-0" CEILING 2. 3. NOTES: 1. FINISHED FLOOR 18" (1'-6") UONNOTE: ALL DEVICES INDICATED TO BE INSTALLED AT DIFFERENT MOUNTING HEIGHTS AND LOCATED WITHIN ONE STUD SPACE FROM EACH OTHER SHALL ALIGN VERTICALLY, ON THE SAME SIDE OF THE STUD. WHERE WALL MOUNTED TELEPHONES OCCUR OVER LIGHT SWITCHES, VOLUME CONTROLS, ETC. OFFSET ONE STUD SPACE. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. BOTTOM OF DEVICE W GFI GZM PB P P CONTROL PANELS TOP S TOP S PC C C B B FAA C C MDC C E MD C C FACP SCR D CB E 1 2 S V T TC S SM I M NO SCALE 16143.1 F TYPICAL DEVICE MOUNTING HEIGHTS NOTE: TRAPEZE SHALL BE PROVIDED WHEREVER TWO OR MORE RACEWAYS ARE RUN ADJACENT. FUTURE STRUT TO BE ATTACHED TO EXISTING STRUT NOTE: SEE SPECIFICATIONS FOR ADDITIONAL SUPPORT, SEISMIC AND OTHER REQUIREMENTS. U-CHANNEL STRUT SPACE FOR FUTURE RACEWAYS 1/2 W MIN. W RACEWAYS INSTALLED AS PART OF THIS CONTRACT SHALL BE ATTACHED TO TOP OF STRUT WITH APPROVED U-CHANNEL STRUT FASTENER STEEL ALL THREADPER SPECS ATTACHED TO STRUCTURE AS REQUIRED NO SCALE 16190.2 TRAPEZE DETAIL 1/2" 1/4" 1/4" 3/16" 1/4" 3/16" 13/16" WIDTH AS REQUIRED 2 1/2" NOTES: 1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION. 2. REWORD NAMEPLATE FOR FIELD CONDITIONS. 3. HP SHALL INDICATE HORSEPOWER. UTILIZATION EQUIPMENT NAMEPLATE DETAIL EXHAUST FAN #1 480V 3Ø HP FED FROM H1A SCALE: FULL 16195.3 AIRFLOW DIRECTION INSERT RUBBER PLUG THIS END OF INLET TUBE. INLET TUBE HOLES FACE UPSTREAM OF AIRFLOW. TUBE SUPPORT HOLE ONLY FOR DUCTS MORE THAN 3' WIDE EXPECTED AIRFLOW DIRECTION RETURN TUBE SLANT CUT FACE ORIENTED DOWN-STREAM OF AIRFLOW. DO NOT INSERT RUBBER PLUG. DUCT WIDTH NO SCALE 16721.2 DUCT DETECTOR DETAIL NOTES: 2 1/2" WIDTH AS REQUIRED 1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION. 2. REWORD NAMEPLATE FOR FIELD CONDITIONS. 3. AMP RATING SHALL INDICATE BUS RATING. SCALE: FULL 16195.2 PANEL L1A 22,000 AIC 120/208V 3Ø, 4W, 225A FED FROM MDC 3/16" 1/4" 1/4" 1/4" 3/16" 3/16" 1/4" 3/16" 3/32" 1/4" SUB-DISTRIBUTION CENTER AND BRANCH PANELBOARD NAMEPLATE DETAIL PH A - BLACK; PH B - RED; PH C - BLUE NEUTRAL - WHITE; GROUND - GREEN 3/16" 3/32"3/32" 4. CONTRACTOR TO COORDINATE DEIVCE MOUNTING HEIGHTS WITH WALL SURFACE SO THAT DEVICES DO NOT OVERLAP TWO SURFACES. FOR EXAMPLE, LIGHT SWTICHES SHALL BE MOUNTED AT 44" WHERE WALL PROTECTION IS INSTALLED UP TO 48" 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/10/2017 1:48:04 PM15924.00 E-401.1 ELECTRICAL DETAILS 07/11/17PERMIT RESUBMISSION EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 8165710/25/17