HomeMy WebLinkAboutB17-0092_G-001.1_1498849080.pdfPROJECT SITE
FRONTAGE RD. WEST
W. MEADOWS DR
LIONSHEAD CIR
VAIL RD
BEAVER DAM RD
FOREST RD
ROCKLEDGE RD
MIL
L CRE
E
K RD
MILL C
REEK RD
LIFT 8 TOWER
I-70
1. THE CONTRACT DOCUMENTS IN THEIR ENTIRETY ARE THE RESPONSIBILITY OF
ALL TRADES. WHERE REQUIREMENTS ARE SHOWN IN ONE SECTION OF THE
SPECIFICATIONS OR DRAWINGS BUT NOT ANOTHER, THE CONTRACTOR OR
SUBCONTRACTOR IS NOT RELIEVED FROM PROVIDING COMPLETELY FINISHED
AND PROPERLY FUNCTIONING SYSTEMS.
2. THE CONTRACTOR / SUBCONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE
LAYOUT AND COORDINATION OF DIMENSIONS IN THE FIELD THAT ESTABLISH
WORK POINTS FOR THEIR WORK AND VARIOUS TRADES.
3. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT
REQUIRED FOR THE PROPER EXECUTION, INSTALLATION, OR PERFORMANCE OF
THE WORK, SHALL BE PROVIDED BY THE CONTRACTOR / SUBCONTRACTOR.
4. ALL ITEMS REQUIRING A METHOD OF PROCEDURE APPROVAL SHALL BE
SUBMITTED FOR REVIEW 21 DAY IN ADVANCE.
5. THE CONSTRUCTION SITE IS TO BE KEPT CLEAN AND FREE OF DEBRIS. THE
CONTRACTOR / SUBCONTRACTOR IS RESPONSIBLE FOR ALL PHASES OF
SECURING, HANDLING, TRANSPORTING AND DISPOSING OF DEBRIS.
6. THE CONTRACTORS / SUBCONTRACTORS SHALL NOT SHUT OFF OR INTERRUPT
ANY SYSTEMS OR SERVICES WITHOUT FIRST COORDINATING WITH THE OWNER.
7. THE CONTRACTOR / SUBCONTRACTORS SHALL COORDINATE WITH THE OWNER
TO IDENTIFY AND PROTECT EXISTING STRUCTURE, ELECTRICAL/DATA/TELECOM
SYSTEMS, UTILITIES, SURFACES AND FINISHES WHICH ARE TO REMAIN. ANY
DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED BY THE
CONTRACTOR/SUBCONTRACTOR.
8. DELIVERY AND STORAGE OF CONSTRUCTION MATERIALS AND EQUIPMENT
(STAGING AREAS) SHALL BE COORDINATED WITH THE OWNER. NOT TO
INTERFERE WITH HOSPITAL TRAFFIC.
9. THE CONTRACTOR / SUBCONTRACTOR SHALL TAKE CARE TO PROTECT ALL
NEWLY INSTALLED MATERIALS AND FINISHES UNTIL WORK IS FORMALLY
ACCEPTED BY THE ARCHITECT OR THE OWNER'S REPRESENTATIVE AND
TRANSFERRED TO THE OWNER
10. ALL PENETRATIONS THROUGH FLOORS, WALLS AND RATED ASSEMBLIES AS WELL
AS ALONG SLAB PERIMETERS AND SEPARATION WALL PERIMETERS, SHALL BE
SEALED AND PROTECTED WITH U.L. APPROVED SAFETY ASSEMBLIES AND/OR
PROTECTIVE DEVICES HAVING THE SAME OR GREATER TESTED RATING AS THAT
REQUIRED FOR THE ASSEMBLY BEING PENETRATED. ALL PENETRATIONS SHALL
BE PROTECTED TO MAINTAIN FIRE RATED ASSEMBLY INTEGRITY.
11. PROVIDE ELECTROLYTIC PROTECTION / ISOLATION BETWEEN ALL DISSIMILAR
METALS, AND BETWEEN TREATED WOOD AND METALS TO PREVENT
ELECTROLYTIC REACTION AND/OR CORROSION.
12. ALL WOOD, EXCEPT ARCHITECTURAL WOODWORK, USED ON THIS PROJECT
SHALL BE FIRE RETARDANT, NON-COMBUSTIBLE TREATED AS APPROVED FOR
USE BY THE LOCAL CODE AUTHORITIES. NO WOOD (WHETHER TREATED OR NOT)
SHALL BE USED WITHIN THE CEILING PLENUM SPACE.
13. THE CONTRACTOR / SUBCONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING,
BACKING OR STRUCTURAL SUPPORT AS REQUIRED TO PROPERLY INSTALL ALL
MOUNTED ASSEMBLIES, INCLUDING ALL ATTACHED EQUIPMENT (OWNER AND
CONTRACTOR FURNISHED ITEMS), PLUMBING FIXTURES, MILLWORK, AND
CASEWORK. NOTE: ALL FRAMING OR CONCEALED BLOCKING SHALL BE METAL
BETWEEN STUDS AS IS RECOMMMENDED FOR WALL MOUNTED ITEMS. REFER TO
THE A-700 SERIES DRAWINGS FOR FUTHER INFORMATION.
14. WHERE FIRE EXTINGUISHER CABINETS, ELECTRICAL PANELS OR OTHER
EQUIPMENT OR DEVICES ARE RECESSED IN FIRE-RATED PARTITIONING AND/OR
SOUND RATED PARTITIONING, MODIFY PARTITION CONSTRUCTION TO PROVIDE
CONTINUOUS ENCLOSURE FOR UNINTERRUPTED ASSOCIATED FIRE RATING
AND/OR SOUND RATING.
15. ALL ROOMS OR AREAS WITH CEILINGS OPEN TO STRUCTURE ARE TO HAVE METAL
WALL GRILLS FOR AIR DUCT OPENINGS OR AT OPEN AIR TRANSFERS.
COORDINATE SIZE OF GRILLE WITH MECHANICAL DRAWINGS AND AIR FLOW
REQUIREMENTS.
16. METAL FRAMING STUD SPACING MAY VARY AT LOCATIONS RECEIVING MOISTURE
RESISTANT GYPSUM BOARD. INSTALL FRAMING AT WALLS, HARD CEILINGS AND
SOFFITS PER MANUFACTURER'S RECOMMENDATIONS. REFER TO
SPECIFICATIONS FOR A DISCRIPTION OF THE LOCATIONS TO RECEIVE MOISTURE
RESISTANT GYPSUM BOARD INCLUDING BUT NOT LIMITED TO LOCATIONS
ADJACENT TO PLUMBING FIXTURES.
17. THE GC SHALL CARRY FIRE WATCH COSTS TO PROVIDE PERSONNEL PER NFPA.
18. THE OWNER WILL BE REQUIRED TO SIGN OFF ON ROUGH IN AND ARCHITECTURAL
DEVICES BEFORE PROCEEDING. SEE SPECIFICATION 01 4000 FOR MORE
INFORMATION.
19. GC TO PROVIDE ICRA COMPLIANCE PLAN TO OWNER FOR APPROVAL PRIOR TO
COMMENCING WORK.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Consultant
Revision Date No.
Sheet Information
Project Information
Location Map
Project Team
Issuance Date
CENTRAL
WING
RENOVATION
Sheet Index General Notes
3/10/2017
3:40:15 PM
15924.00
G-001.1
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
SHEET INDEX AND
PROJECT DATA
ARCHITECT
Davis Partnership Architects
2901 Blake Street
Suite 100
Denver, CO 80205
P. 303.861.8555
Ann Adams
ann.adams@davispartnership.com
OWNER
Vail Valley Medical Center
180 S Frontage Road W
Vail, CO 81657
Helen Rowe
helen.rowe@vvmc.com
CIVIL ENGINEER
Martin/Martin, Inc.
0101 Fawcett Rd.
Suite 260
Avon, Co 81620
P. 970.926.6007
Mark Luna
mluna@martinmartin-mtn.com
OWNER REPRESENTATIVE
Project One Integrated Services
88 Inverness Cir E
Building G, Suite 101
Englewood, CO 80112
P. 303.917.7507
Chris Knight
chrisk@projectoneis.com
MECHANICAL, ELECTRICAL, PLUMBING
Cator Ruma & Associates Co
896 Tabor Street
Lakewood, CO 80401
P. 303.232.6200
Wayne Trader
wtrader@catorruma.com
CODE CONSULATANT
Advanced Consulting Engineers
3900 S. Wadsworth Blvd.
Suite 595
Lakewood, CO 80235
P. 720.981.4150
Masoud Sabounchi
masoud@acecode.com
STRUCTURAL ENGINEER
Martin/Martin, Inc.
12499 W. Colfax Ave.
Lakewood, CO 802015
P. 303.431.6100
Shane McCormick
smccormick@martinmartin.com
MEDICAL EQUIPMENT
Mitchell Associates
630 Dundee RD Suite 340
Northbrook, IL 60062
360.798.7653
Matt Gibbs
mgibbs@mitchellplanning.com
INTERIOR DESIGNER
Davis Partnership Architects
2901 Blake Street
Suite 100
Denver, CO 80205
P. 303.861.8555
Janette Ray
janette.ray@davispartnership.com
2017
03/10/17
PERMIT
NUMBER SHEET
ISSUANCE
ISSUE
DATE
12 Plumbing Demolition
PD101.1 LEVEL 1 AND 2 DEMOLITION WASTE AND VENT PLANS - CENTRAL PERMIT 03/10/17
PD111.1 LEVEL 1 AND 2 DEMOLITION DOMESTIC WATER PLANS - CENTRAL PERMIT 03/10/17
13 Plumbing
P-001.1 PLUMBING LEGENDS & NOTES PERMIT 03/10/17
P-002.1 PLUMBING SCHEDULES & DETAILS PERMIT 03/10/17
P-111.1 LEVEL 1 AND 2 WASTE & VENT PLAN - CENTRAL PERMIT 03/10/17
P-121.1 LEVEL 1 AND 2 DOMESTIC WATER PLAN - CENTRAL PERMIT 03/10/17
P-131.1 LEVEL 1 AND 2 MEDICAL GAS PLAN - CENTRAL PERMIT 03/10/17
14 Mechanical Demolition
MD-111.1 LEVEL 1 DEMOLITION HVAC PLAN - CENTRAL PERMIT 03/10/17
MD-121.1 LEVEL 1 HVAC PIPING PLAN - CENTRAL PERMIT 03/10/17
15 Mechanical
M-001.1 MECHANICAL LEGENDS & NOTES PERMIT 03/10/17
M-002.1 MECHANICAL SCHEDULES PERMIT 03/10/17
M-111.1 LEVEL 1 AND 2 HVAC PLAN - CENTRAL PERMIT 03/10/17
M-117.1 ROOF HVAC PLAN - CENTRAL PERMIT 03/10/17
M-121.1 LEVEL 1 HVAC PIPING PLAN - CENTRAL PERMIT 03/10/17
M-401.1 MECHANICAL DETAILS PERMIT 03/10/17
16 Electrical Demolition
ED-101.1 LEVEL 1 DEMOLITION LIGHTING PLAN - CENTRAL PERMIT 03/10/17
ED-102.1 LEVEL 2 DEMOLITION LIGHTING PLAN - CENTRAL PERMIT 03/10/17
ED-111.1 LEVEL 1 DEMOLITION POWER PLAN - CENTRAL PERMIT 03/10/17
ED-112.1 LEVEL 2 DEMOLITION POWER PLAN - CENTRAL PERMIT 03/10/17
ED-121.1 LEVEL 1 DEMOLITION FIRE ALARM PLAN - CENTRAL PERMIT 03/10/17
ED-122.1 LEVEL 2 DEMOLITION FIRE ALARM PLAN - CENTRAL PERMIT 03/10/17
17 Electrical
E-001.1 ELECTRICAL LEGENDS & NOTES PERMIT 03/10/17
E-002.1 ELECTRICAL SCHEDULES PERMIT 03/10/17
E-011.1 ELECTRICAL ONE-LINE DIAGRAM - WEST NORMAL ENTRANCE PERMIT 03/10/17
E-012.1 ELECTRICAL ONE-LINE DIAGRAM - WEST NORMAL POWER PERMIT 03/10/17
E-013.1 ELECTRICAL ONE-LINE DIAGRAM - WEST EMERGENCY POWER PERMIT 03/10/17
E-014.1 ELECTRICAL ONE-LINE DIAGRAM - WEST CRITICAL AND EQUIPMENT PERMIT 03/10/17
E-015.1 ELECTRICAL ONE-LINE DIAGRAM - EAST NORMAL POWER PERMIT 03/10/17
E-016.1 ELECTRICAL ONE-LINE DIAGRAM - EAST EMERGENCY POWER PERMIT 03/10/17
E-101.1 LEVEL 1 LIGHTING PLAN - CENTRAL PERMIT 03/10/17
E-102.1 LEVEL 2 LIGHTING PLAN - CENTRAL PERMIT 03/10/17
E-111.1 LEVEL 1 POWER PLAN - CENTRAL PERMIT 03/10/17
E-112.1 LEVEL 2 POWER PLAN - CENTRAL PERMIT 03/10/17
E-113.1 ROOF POWER PLAN - CENTRAL PERMIT 03/10/17
E-121.1 LEVEL 1 FIRE ALARM PLAN - CENTRAL PERMIT 03/10/17
E-122.1 LEVEL 2 FIRE ALARM PLAN - CENTRAL PERMIT 03/10/17
E-301.1 ELECTRICAL PANEL SCHEDULES PERMIT 03/10/17
E-302.1 ELECTRICAL PANEL SCHEDULES PERMIT 03/10/17
E-401.1 ELECTRICAL DETAILS PERMIT 03/10/17
20 Technology Demolition
TD.101.1 LEVEL 1 - DEMOLOTION TECHNOLOGY PLAN - CENTRAL PERMIT 03/10/17
TD.102.1 LEVEL 2 DEMOLITION TECHNOLOGY PLAN - CENTRAL PERMIT 03/10/17
21 Technology
T-001.1 TECHNOLOGY LEGENDS & NOTES PERMIT 03/10/17
T-101.1 LEVEL 1 TECHNOLOGY PLAN - CENTRAL PERMIT 03/10/17
T-102.1 LEVEL 2 TECHNOLOGY PLAN - CENTRAL PERMIT 03/10/17
22 Equipment
Q-101A ENLARGED MEDICAL EQUIPMENT PLAN - AREA A PERMIT 03/10/17
Q-101B ENLARGED MEDICAL EQUIPMENT PLAN - AREA B PERMIT 03/10/17
Q-102C ENLARGED MEDICAL EQUIPMENT PLAN - AREA C PERMIT 03/10/17
NUMBER SHEET ISSUANCE
ISSUE
DATE
01 General
G-000.1 COVER PERMIT 03/10/17
G-001.1 SHEET INDEX AND PROJECT DATA PERMIT 03/10/17
02 Life Safety
LS000.1 CODE ANALYSIS PERMIT 03/10/17
LS101.1 LIFE SAFETY PLAN - LEVEL 1 PERMIT 03/10/17
LS101.2 LIFE SAFETY PLAN - LEVEL 1 - OCCUPANCY & USE PERMIT 03/10/17
LS102.1 LIFE SAFETY PLAN - LEVEL 2 PERMIT 03/10/17
LS102.2 LIFE SAFETY PLAN - LEVEL 2 - OCCUPANCY & USE PERMIT 03/10/17
LS200A.1 INTERIM LIFE SAFETY PLAN - AREA A PERMIT 03/10/17
LS200B.1 INTERIM LIFE SAFETY PLAN - AREA B PERMIT 03/10/17
LS200C.1 INTERIM LIFE SAFETY PLAN - AREA C PERMIT 03/10/17
02 Site Survey
L101.1 COMBINED SURVEY PERMIT 03/10/17
07 Structural
S-001 GENERAL NOTES PERMIT 03/10/17
S-002 QUALITY ASSURANCE PERMIT 03/10/17
S-101 LEVEL 1 FRAMING PLAN PERMIT 03/10/17
S-102 LEVEL 2 FRAMING PLAN PERMIT 03/10/17
S-200 FRAMING DETAILS PERMIT 03/10/17
08 Architectural Demolition
A-000.1 ABBREVIATIONS & SYMBOLS PERMIT 03/10/17
AD101.1 OVERALL DEMOLITION PLAN - LEVEL 1 PERMIT 03/10/17
AD101A.1 ENLARGED DEMOLITION FLOOR PLAN - AREA A PERMIT 03/10/17
AD101B.1 ENLARGED DEMOLITION FLOOR PLAN - AREA B PERMIT 03/10/17
AD102.1 OVERALL DEMOLITION PLAN - LEVEL 2 PERMIT 03/10/17
AD102C.1 ENLARGED DEMOLITION FLOOR PLAN - AREA C PERMIT 03/10/17
AD151.1 OVERALL DEMOLITION RELFECTED CEILING PLAN - LEVEL 1 PERMIT 03/10/17
AD151A.1 ENLARGED DEMOLITION REFLECTED CEILING PLAN - AREA A PERMIT 03/10/17
AD151B.1 ENLARGED DEMOLITION REFLECTED CEILING PLAN - AREA B PERMIT 03/10/17
AD152.1 OVERALL DEMOLITION RELFECTED CEILING PLAN - LEVEL 2 PERMIT 03/10/17
AD152C.1 ENLARGED DEMOLITION RELFECTED CEILING PLAN - AREA C PERMIT 03/10/17
AD201.1 DEMOLITION ELEVATIONS PERMIT 03/10/17
09 Architectural
A-101.1 OVERALL FLOOR PLAN - LEVEL 1 PERMIT 03/10/17
A-101A.1 ENLARGED ANNOTATION FLOOR PLAN - AREA A PERMIT 03/10/17
A-101A.2 ENLARGED DIMENSION FLOOR PLAN - AREA A PERMIT 03/10/17
A-101B.1 ENLARGED FLOOR PLAN - AREA B PERMIT 03/10/17
A-102.1 OVERALL FLOOR PLAN - LEVEL 2 PERMIT 03/10/17
A-102C.1 ENLARGED ANNOTATION FLOOR PLAN - AREA C PERMIT 03/10/17
A-102C.2 ENLARGED DIMENSION FLOOR PLAN - AREA C PERMIT 03/10/17
A-107.1 OVERALL FLOOR PLAN - ROOF PERMIT 03/10/17
A-151.1 OVERALL REFLECTED CEILING PLAN - LEVEL 1 PERMIT 03/10/17
A-151A.1 ENLARGED REFLECTED CEILING PLAN AREA A PERMIT 03/10/17
A-151B.1 ENLARGED REFLECTED CEILING PLAN AREA B PERMIT 03/10/17
A-152.1 OVERALL REFLECTED CEILING PLAN - LEVEL 2 PERMIT 03/10/17
A-152C.1 ENLARGED REFLECTED CEILING PLAN - LEVEL 2 - AREA C PERMIT 03/10/17
A-200.1 EXTERIOR ELEVATION & PERSPECTIVES PERMIT 03/10/17
A-300.1 BUILDING SECTIONS PERMIT 03/10/17
A-310.1 WALL SECTIONS AND PERSPECTIVES - EXTERIOR PERMIT 03/10/17
A-320.1 WALL SECTIONS AND PERSPECTIVES - INTERIOR PERMIT 03/10/17
A-401A.1 AREA A ENLARGED PLANS AND INTERIOR ELEVATIONS PERMIT 03/10/17
A-401A.2 AREA A ENLARGED PLANS AND INTERIOR ELEVATIONS PERMIT 03/10/17
A-401B.1 AREA B ENLARGED PLANS AND INTERIOR ELEVATIONS PERMIT 03/10/17
A-401C.1 AREA C ENLARGED PLANS AND INTERIOR ELEVATIONS PERMIT 03/10/17
A-520B.1 EXTERIOR DETAILS PERMIT 03/10/17
A-550.1 INTERIOR DETAILS PERMIT 03/10/17
A-551.1 INTERIOR DETAILS PERMIT 03/10/17
A-591.1 DETAILS - CASEWORK PERMIT 03/10/17
A-592.1 DETAILS - CASEWORK PERMIT 03/10/17
A-621A.1 ENLARGED FINISH FLOOR PLAN - AREA A PERMIT 03/10/17
A-621B.1 ENLARGED FINISH FLOOR PLAN - AREA B PERMIT 03/10/17
A-622C.1 ENLARGED FINISH FLOOR PLAN - AREA C PERMIT 03/10/17
A-720.1 DOOR SCHEDULE, PARTITION TYPES, AND DETAILS PERMIT 03/10/17
A-721.1 FRAMING DETAILS PERMIT 03/10/17
A-740.1 WINDOW TYPES AND DETAILS PERMIT 03/10/17
A-760.1 INTERIOR MOUNTING HEIGHTS PERMIT 03/10/17
A-760.2 INTERIOR MOUNTING HEIGHTS/ TOILET ACCESSORIES SCHEDULE PERMIT 03/10/17