Loading...
HomeMy WebLinkAboutB17-0092_LS000.1_1508947562.pdfEXISTING FIRE RESISTIVE REQUIREMENTS TO BE STRUCTURAL FRAME BEAMS COLUMNS EXTERIOR BEARING WALLS INTERIOR BEARING WALLS EXTERIOR NONBEARING WALLS FLOOR CONSTRUCTION ROOF CONSTRUCTION & CANOPY SHAFT & VERTICAL EXIT ENCLOSURES EXTERIOR OPENINGS IBC RATING TESNFPA RATING CONSTRUCTION (TYPE I B) UL 263 UL 790 IBC: 2 HR (TO MATCH FLOOR RATING) NFPA: 2 HR IF 4+ STORIES, 1 HR IF >4 STORIES, EXISTING ENCLOSURES = 0.5 HR. NOTE : REFER TO PARTITION TYPES SCHEDULE ON A720.1 FOR UL ASSEMBLIES AT ADDITIONAL INTERIOR PARTITIONS AND WALL RATINGS AND SPECIFICATION SECTION 078413 PENETRATION FIRESTOPPING FOR USE OF UL ASSEMBLIES AT THROUGH-PENETRATION FIRESTOP CONDITIONS. REMARK 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 1 HR 2 HR 1 HR 2 HR 1.5 HR NOTE: WORK TIMES LIMITED BY "VAIL 2016 VAIL VILLAGE AND LIONSHEAD VILLAGE CONSTRUCTION INFORMATION HANDOUT" IN ADDITION TO OWNER REQUIREMENTS. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:29:02 AM15924.00 LS000.1 CODE ANALYSIS 2017 07/11/17PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 8165710/25/17