HomeMy WebLinkAboutB17-0092_LS201D.1_1508947567.pdfLEGEND EXISTING TO REMAIN NEW WALL KEY PLAN GENERAL NOTES 1. SPRINKLER SYSTEM PROTECTION WILL REMAIN OPERATIONAL EXCEPT FOR ANY SPRINKLER MODIFICATION REQUIRED TO ACCOMMODATE THE REMODEL. SPRINKLER SYSTEM WILL BE OFF LINE FOR NOT MORE THAN 4 HOURS FOR THE RESPECTIVE SMOKE COMPARTMENT WHILE SPRINKLER REMODEL IS TAKING PLACE. UNLESS FIRE WATCH IS IN PLACE. 2. SPRINKLER SYSTEM SHOP DRAWINGS WILL BE SUBMITTED FOR REVIEW. 3. EXISTING SMOKE DETECTORS WILL BE COVERED DURING THE REMODEL WITHIN THESE SUITES. TEMPORARY PARTION PER NFPA 241. PLASTIC CURTAINS ARE NOT ACCEPTABLE REGION INDICATES AREA NOT IN SCOPE REMOVE AND REPLACE CEILING KEYNOTES PASSAGE THROUGH EXISTING CORRIDOR TO BE MAINTAINED AT ALL TIMES. PROVIDE TEMPORARY PARTITION SUCH THAT EXISTING EGRESS CAN BE MAINTAINED WHILE DEMOLISHING CEILING THIS AREA WOULD NOT BE OCCUPIED DURING CONSTRUCTION PASSAGE THROUGH EXISTING CORRIDORTO BE MAINTAINED AT ALL TIMES. PROVIDE TEMPORARY PARTITION SUCH THAT EXISTING EGRESS CAN BE MAINTAINED WHILE DEMOLISHING CEILINGS NOTE: WORK TO BE PERFORMED DURING OFF-HOURS OR IN A MANNER THAT DOES NOT IMPACT THE OPERATIONS OF THE CARDIO PULMONARY SUITE EXISTING DOOR AND EXIT LIGHT TO BE MAINTAINED DURATION: FIRST HALF OF SEQUENCE #2 - SEE G-010.2 FOR MORE INFORMATION. F102 F102 RECEPTION 102 PASSAGE THROUGH EXISTING CORRIDOR TO BE MAINTAINED AT ALL TIMES. THIS AREA WOULD NOT BE OCCUPIED DURING CONSTRUCTION PASSAGE THROUGH EXISTING CORRIDOR TO BE MAINTAINED AT ALL TIMES. NOTE: WORK TO BE PERFORMED DURING OFF-HOURS OR IN A MANNER THAT DOES NOT IMPACT THE OPERATIONS OF THE CARDIO PULMONARY SUITE DURATION: SECOND HALF OF SEQUENCE #2 - SEE G-010.2 FOR MORE INFORMATION. F102 F102 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/11/2017 10:30:12 AM15924.00 LS201D.1 INTERIM LIFE LAFETY PLAN - AREA D 2017 07/11/17PERMIT RESUBMISSION VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657A B C D E 1 1/4" = 1'-0"A1 ENLARGED ILSM FLOOR PLAN - AREA A NORTH 1/4" = 1'-0"C1 ENLARGED ILSM FLOOR PLAN - AREA A NORTH F10 EXISTING UPPER MILLWORK TO REMAIN, REPLACE LOWER CABINETS WITH ADA COMPLIANT 32" BASE CABINETS. F102 PER 2012 NFPA 101, SECTION 4.6.10.1, "BUILDINGS OR PORTIONS OF BUILDINGS SHALL BE PERMITTED TO BE OCCUPIED DURING CONSTRUCTION ONLY WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED" ADDENDUM 1 05/23/17 1 10/25/17