HomeMy WebLinkAboutB17-0092_M-001-1_1498849080.pdfHVAC LEGEND
SYMBOL DESCRIPTION ABBR. DESCRIPTION
LOW PRESSURE CONDENSATE RETURN PIPING
HOT WATER SUPPLY PIPING
HOT WATER RETURN PIPING
HIGH TEMPERATURE HOT WATER SUPPLY PIPING
HIGH TEMPERATURE HOT WATER RETURN PIPING
CHILLED WATER SUPPLY PIPING
CHILLED WATER RETURN PIPING
SUPPLY DUCT UP / SUPPLY DUCT DOWN
RETURN DUCT UP / RETURN DUCT DOWN
FLEXIBLE DUCT CONNECTION
BACKDRAFT DAMPER
TEMP. CONTROL DAMPER-OPPOSED BLADE
LOUVER WITH SCREEN
MANUAL VOLUME DAMPER
MOTOR OPERATED DAMPER
SPIN-IN FITTING WITH MVD
CONDENSER WATER SUPPLY PIPING
LOW PRESSURE STEAM SUPPLY PIPING (0 - 15#)
ROUND DUCT UP / ROUND DUCT DOWN
INDICATES FLAT OVAL DUCTWORK
ABBR.
SYMBOL
COOLING COIL DRAIN PAN PIPING
TEMP. CONTROL DAMPER- PARELLEL BLADE
LPS
LPC
MPS
MVD
MPC
BBD
BF
RL
RS
RHG
TT
MEDIUM PRESSURE STEAM SUPPLY PIPING (16# - 60#)
MEDIUM PRESSURE CONDENSATE RETURN PIPING
HIGH PRESSURE STEAM SUPPLY PIPING (61# - 125#)
HIGH PRESSURE CONDENSATE RETURN PIPING
PUMPED CONDENSATE PIPING
BOILER BLOWDOWN PIPING
REFRIGERANT SUCTION PIPING
BOILER FEED WATER PIPING
FLOAT AND THERMOSTATIC STEAM TRAP
REFRIGERANT LIQUID PIPING
REFRIGERANT HOT GAS PIPING
TCD
FD
FSD
SD
DAD
TEMPERATURE SENSOR
DUCT FIRE DAMPER
COMBINATION DUCT SMOKE & FIRE DAMPER
DUCT SMOKE DAMPER
DUCT SMOKE DETECTOR
DUCT ACCESS DOOR
ELECTRIC-PNEUMATIC CONTROL VALVE
TURNING VANES IN DUCT ELBOW
WALL MOUNTED THERMOSTAT
PNEUMATIC-ELECTRIC CONTROL SWITCH
LOUVER
HUMIDISTAT
DUCT RISE
UNIT MOUNTED THERMOSTAT
UNDERCUT DOOR
THERMOSTATIC STEAM TRAP
DUCT DROP
HWS
HWR
HTWS
HTWR
CWS
CWR
D
C
CR
HPS
HPC
PC
F&T
IBT
TCV
MAV
AAV
FS
EJ
BJ
RSV
DPS
(2 OR 3-WAY) TEMPERATURE CONTROL VALVE
INVERTED BUCKET STEAM TRAP
VENTURI METER
CALIBRATED BALANCING VALVE
REFRIGERANT SERVICE VALVE
AUTOMATIC AIR VENT
DIFFERENTIAL PRESSURE SWITCH
MANUAL AIR VENT
FLOW SWITCH
EXPANSION JOINT
CONDENSER WATER RETURN PIPING
BALL JOINT EXPANSION COMPENSATOR
LPS
LPC
MPS
MPC
BBD
BF
RL
RS
RHG
HWS
HWR
HTWS
HTWR
CWS
CWR
D
C
CR
HPS
HPC
PC
SUPPLY & RETURN BRANCH
PIPING TO TERMINAL UNIT
CWR,HWR
CWS,HWS
CWS,CWR/HWS,HWR
~
~~
ACOUSTICALLY LINED DUCTWORK
TEMPERATURE CONTROL OUTSIDE AIR DAMPER
TEMPERATURE CONTROL RETURN AIR DAMPER
TEMPERATURE CONTROL EXHAUST AIR DAMPER
STATIC PRESSURE IN INCHES WATER COLUMN
SUPPLY AIR DEVICE
RETURN AIR DEVICE
M
TS
F
~~
T
T
~~
H
U
L
R
D
SD
RG
SP IN WC
TCEAD
TCRAD
TCOAD
A.L.
48F12
TCD
BDD
EP
PE
DOUBLE/SINGLE LINE DUCT LEGEND
45° TEE (ROUND)
FLEX DUCT 90° RADIUS ELBOW
RIGID FLEX
45° TEE (RECTANGULAR) 90° TEE (ROUND) MANUAL VOLUME DAMPER 90° ELBOW
DUCT SPLIT
REDUCER 45° ELBOW
GRD RUNOUT
90° TEE (RECTANGULAR)
SEE DUCT
TAKE-OFF DETAIL
CONICAL
TEE
VOLUME
DAMPER
GENERAL LEGEND
SYMBOL DESCRIPTION ABBR.
DESCRIPTION
NEW
SECTION DESIGNATION
SECTION DRAWN ON THIS SHEET
SECTION CUT ON THIS SHEET
RISER DIAGRAM NUMBER
SHEET RISER IS DRAWN ON
EQUIPMENT UNIT IDENTIFICATION
CAP END OF PIPE
PITCH DOWN IN DIRECTION OF ARROW
UNION OR FLANGE
CONCENTRIC PIPE REDUCER
ECCENTRIC PIPE REDUCER
PRESSURE AND/OR TEMPERATURE RELIEF VALVE
PLUG VALVE
GATE VALVE
VERTICAL PIPE VALVE
DIFFUSER IDENTIFICATION
DIFFUSER NECK DIAMETER
DIFFUSER CFM
EXISTING
PIPE ANCHOR
PIPE ALIGNMENT GUIDE
ABBR. SYMBOL
EQUIPMENT UNIT NUMBER
PRESSURE REDUCING VALVE
(E)
(N)
(R)
PTRV
(F)
DIA
WAD
NIC
AFF
GC
MC
EC
RELOCATED
FUTURE
POINT OF CONNECTION, NEW TO EXISTING
DIRECTION OF FLOW IN PIPE
DUCTWORK, PIPING AND EQUIPMENT TO BE REMOVED
DIAMETER
ABOVE FINISHED FLOOR
WALL ACCESS DOOR
ELECTRICAL CONTRACTOR
NOT IN CONTRACT
GENERAL CONTRACTOR
PRV
GLV
BFV
BV
CV
P/T
STRAINER W/ BLOWDOWN
GLOBE VALVE
BUTTERFLY VALVE
BALL VALVE
CHECK VALVE
SOLENOID VALVE
PRESSURE / TEMPERATURE TAP
BUTTERFLY SOLENOID VALVE
FLEXIBLE PIPE CONNECTOR
HOSE END DRAIN VALVE
STRAINER
CEILING ACCESS PANEL
PRESSURE GAUGE
PUMP
THERMOMETER
SIGHT GLASS
C.A.P.
TB
MECHANICAL CONTRACTOR
#
UNIT
M-X
X
X.X X.X
X
GV
THRUST BLOCK
XX
P/T
DETAIL SHEETS PLAN SHEETS
XX
(Not all symbols listed below are used on these drawings) (Not all symbols listed below are used on these drawings)
NECK
CFM
X
EXHAUST DUCT UP / EXHAUST DUCT DOWN
WALL MOUNTED CARBON DIOXIDE SENSOR
C
EXHAUST AIR DEVICE
EG
KEYNOTE
SINGLE LINE
DOUBLE LINE
DOUBLE LINE
SINGLE LINE
SINGLE LINE
FLEX
RIGID
SINGLE LINE DOUBLE LINE
DOUBLE LINE
(Not all symbols listed below are used on these drawings)
DP
T
IBT
F&T
TT
RND
REC
45° TAKEOFF
SPIN IN
X
RETURN AIR DEVICE WITH SOUND BOOT
RG
~~
POINT OF DISCONNECTION (DEMO)
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
9:33:34 AM
180 S. Frontage
Road
West,
Vail, CO 81657
15924.00
M-001.1
MECHANICAL LEGENDS &
NOTES
2017
03/10/17
PERMIT
VAIL
VALLEY
MEDICAL
CENTER
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS
TO REMAIN ARE DENOTED LIGHTLY.
A DETAILED METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION
ACTIVITY AFFECTS THE SAFETY OF THE OCCUPANTS, OWNER'S EQUIPMENT OR
VALUABLE CONTENTS OR ANY SYSTEM WHICH SUPPORTS THESE SYSTEMS; OR
ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY.
CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING
CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK AND SHALL NOTIFY THE
ENGINEER/ARCHITECT OF ANY DISCREPANCIES FOR RESOLUTION.
COORDINATE WORK WITH ALL TRADES.
CONTRACTOR IS RESPONSIBLE FOR SECURING AND WEATHERPROOFING ANY
ROOF OPENING NOT COMPLETED DURING WORKING HOURS.
COORDINATE ALL DUCTWORK AND PIPING WITH EQUIPMENT, STRUCTURE, ETC.
CONTRACTOR SHALL BE RESPONSIBLE FOR DEACTIVATION OF ROOF-MOUNTED
EQUIPMENT AND ASSOCIATED INDOOR EQUIPMENT. ONLY ONE UNIT SHALL BE
TAKEN OUT OF SERVICE AT ANY TIME, WITH REMAINDER OF UNITS LEFT
OPERATIONAL.
CONTRACTOR SHALL NOT SHUT DOWN / TAKE OUT OF SERVICE ANY SYSTEMS
WITHOUT FIRST COORDINATING WITH OWNER AND PREPARING M.O.P.
DEMOLITION GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
EXISTING ITEMS TO REMAIN ARE DENOTED LIGHTLY UNLESS OTHERWISE NOTED. ALL
ITEMS SHOWN HATCHED SHALL BE REMOVED UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSTEMS OR
SERVICE WITHOUT FIRST COORDINATING WITH THE OWNER.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND
UNDERSTAND THE EXTENT OF THE REMODEL WORK REQUIRED PRIOR TO BID. NO
EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS
INDICATED BY THE CONTRACT DOCUMENT.
CONTRACTOR SHALL DETERMINE AND COORDINATE THE EXACT EXTENT OF
DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT DOCUMENT.
PRIOR TO COMMENCEMENT OF ANY DEMOLITION WORK, VERIFY EXISTING
CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION.
ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY
UNLESS OTHERWISE NOTED. REMOVED ITEMS SHALL BE TURNED OVER TO THE
OWNER UNLESS OTHERWISE NOTED AND STORED IN THE AREA DESIGNATED BY THE
OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER
CHOOSES NOT TO ACCEPT.
WHERE EXISTING PIPING, T.C. TUBING/WIRING ETC. ARE TO BE REMOVED FROM
WALLS WHICH ARE REMAINING, THE WALLS SHALL BE REPAIRED TO MATCH ORIGINAL
CONDITIONS.
WHERE EXISTING PIPING TO BE REMOVED PASSES THROUGH FLOORS, THEY SHALL
BE CUT BACK TO WITHIN CONCRETE AND FILLED WITH GROUT TO ACHIEVE A
SMOOTH AND EVEN FINISH WITH CONCRETE SURFACE.
EXISTING VAV BOXES INDICATED AS TO BE REMOVED BOTH ON THE PLANS AND ON
THE EXISTING VAV BOX SCHEDULE ARE TO BE REMOVED BACK TO THE MEDIUM
PRESSURE MAIN.
HVAC PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
ALL SUPPLY AIR DIFFUSERS ARE 4-WAY AIR PATTERN UNLESS SHOWN OTHERWISE.
DUCT SIZE OF BRANCH DUCT TO AIR DEVICE SHALL BE THE SAME SIZE AS NECK SIZE
OF AIR DEVICE UNLESS NOTED OTHERWISE.
ALL HEATING WATER SUPPLY AND RETURN BRANCH PIPING TO TERMINAL BOXES
SHALL BE 3/4" UNLESS NOTED OTHERWISE. ALL PIPING TAKE-OFFS FROM MAINS
SHALL BE TOP TAKE-OFFS WITH SWING JOINTS.
BRANCH DUCT SIZE TO INLET OF ALL TERMINAL BOXES SHALL BE THE SAME SIZE AS
THE INLET SCHEDULED UNLESS NOTED OTHERWISE. BRANCH DUCTS TO TERMINAL
BOXES EXCEEDING 15' OR TWO ELBOWS, SHALL BE UP-SIZED TO NEXT STANDARD
DIAMETER.
UNLESS OTHERWISE NOTED, ALL SUPPLY AIR DUCTWORK SHALL BE EXTERNALLY
WRAPPED TO THICKNESS AS STATED IN SPECIFICATIONS. RETURN AND EXHAUST
DUCTWORK IS NEITHER LINED NOR WRAPPED.
PROVIDE ROOM AIR BALANCE TO ACHIEVE POSITIVE (+) OR NEGATIVE (-) AT THE
DIFFERENTIAL PRESSURE INDICATED ON THE DRAWINGS.
PROVIDE EOMD AT ALL LOW POINTS FOR STEAM SUPPLY PIPING AS REQUIRED
WHICH MAY NOT NECESSARILY BE SHOWN.
ALL BRANCH STEAM SUPPLY AND CONDENSATE RETURN PIPING FROM MAINS SHALL
BE TOP TAKE-OFFS WITH SWING JOINTS.
PROVIDE MANUAL VOLUME DAMPER FOR ALL AIR DEVICES. SPIN-IN DAMPERS ARE
REQUIRED FOR LOW PRESSURE SUPPLY TAKEOFFS. REFER TO DETAILS.
06/30/17