Loading...
HomeMy WebLinkAboutB17-0092_M-111-1_1498849080.pdfT FC 1-1 6"∅ 100 CFM 6"∅ 12/12 UP TO EF-8 14/12 14/12 14/10 12/10 12/8 CUH 10/10 10/8 10/8 8/8 12/10 12/10 8/8 8/8 10/8 8/10 8/8 8/8 30/18 460 14/8 30/18 D DHC-8 14/14 24/14 30/1 22/10 18/10 1 24/14 18/10 1 12/12 460 CAP FO FUTUR 8 1 16/14 10/8 STEADMAN IT ROOM AHU-14 (E) EF 160 360 70 60 100 H H T AC 1 (E)112 VAV (E)114 VAV (E)113 VAV (E)102 VAV (E)109 VAV (E)105 VAV (E)101 VAV (E)115 VAV (E)104 VAV (E)103 VAV (E)108 VAV (N)109A VAV 50"x12" 10" 50"x12" 36"x12" 24"x12" 60"x30" 16"x12" 10"x8" 10"x12" 20"x12" 12"x12" 16"x12" 16"x12" (N)102A VAV 8" A 200 (TYP. OF 2) (N)105A VAV 8" A 150 (TYP. OF 2) 8" A 150 (TYP. OF 2) 120 220 14" 8" / 8" B 100 RECONNECT EXISTING DIFFUSER FLEX DUCT AND BALANCE TO 100 CFM (E) EXHAUST UP (E)111 VAV (N)107A VAV (R)107 VAV H3 H4 H7 N1 H (N)108A VAV Q4 8" A 150 (TYP. OF 4) 28"x12" 34"x12" 30"x10" 24"x10" 12"x10" 24"x12" 24"x12" 10" A 380 (TYP. OF 5) 8" A 95 8" A 100 8" 160 A 8" / 8" C 235 8" / 8" B 75 8" / 8" B 75 8" / 8" 30 B H15 H15 12"x10" 12"x10" 12"x12" 10" 14"x6" 14"x6" 75 22" / 10" B 125 8" B 300 110 100 75 75 100 50 50 100 200 150 150 100 100 100 100 140 140 140 90 90 90 90 120 1000 1000 1000 500 500 200 180 180 180 300 120 170 170 335 90 90 120 90 200 140 100 280 12"x10" 8"x8" 120 H18 H18 150 H18 8" B 150 (TYP. OF 2) H18 12"x10" 8" B 150 (TYP. OF 2) 100 8" B 150 150 80 75 85 8" A 130 8" A 100 (TYP. OF 3) 50 300 10" 8" 8" A 200 H18 150 14" 14" 14" 14" 16" 24"x10" 20"x20" THIS ELBOW IS NOT EXISTING AND NEEDS TO BE REPLACED. B 100 22" / 10" (TYP. OF 3) 16"x10" (E)110 VAV (E)106 VAV NEW FSD 14"x10" B 950 22" / 22" (TYP. OF 2) 8"x8" H20 50 H18 H18 B 100 22" / 10" 8" A 100 32"x16" 34"x16" 24"x10" 24"x14" CHEMO HOOD EXHAUST UP THRU ROOF 14" 40"x14" 40"x14" H8 H7 H7 H7 H7 H7 H7 H7 H7 H7 H7 H7 H7 H7 H9 H9 REMOVE THE CV CONTROL DAMPER ON L4. REPLACE W/ SPOOL PIECE. 8'-6" B.O.S. STACKED SA & RA MAINS 1-2-24 VAV 1-2-25 VAV 1-2-23 TB 1-2-21 VAV 1-2-22 VAV 40"x14" 40"x14" 40"x14" 20"x14" 18"x16" H10 H12 H12 8" F 0 (TYP. OF 2) 12" F 480 10" F 355 8" A 150 10" A 300 (TYP. OF 2) 8" 100 A 8" A 100 10" A 300 B 300 22" / 10" 10" 250 22" / 10" B B 650 22" / 22" 20"x14" 14"x10" 8"x10" 40"x14" 24"x10" 14"x14" CHEMO HOOD DOWN TO HOOD RELOCATE EXISTING MINOR DRAIN PIPING IN THIS AREA TO ACCOMODATE DUCT ROUTING 24"x10" 24"x10" 24"x10" 20"x10" 16"x10" 20"x10" 14"x10" 14"x10" 28"x10" 28"x10" 28"x10" 18"x10" 210 220 200 200 210 200 200 240 210 210 190 190 200 200 200 240 130 80 130 700 230 H18 (RB) 100 CFM (RB) 215 CFM (RB) 75 CFM (RB) 70 CFM (TYP. 2) H19 H19 H19 (RB) 115 CFM H21 (RB) 120 CFM H18 H18 H18 H19 110 110 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 9:33:45 AM 180 S. Frontage Road West, Vail, CO 81657 15924.00 M-111.1 LEVEL 1 AND 2 HVAC PLANS - CENTRAL 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER A B C KEYNOTES H3 REPLACE EXISTING FAN AS SCHEDULED AND AS INDICATED ON ROOF PLAN. REBALANCE SYSTEM AND ALL GRILLES TO INDICATED AIRFLOWS. H4 RELOCATE EXISTING VAV BOX AND HEATING WATER COIL AND RECONNECT H7 PRIOR TO DEMOLITION, SUBMIT TEST AND BALANCE PRE-READS FOR THIS EXISTING EQUIPMENT AND REBALANCE EXISTING TERMINAL BOXES, GRILLES, REGISTERS, AND DIFFUSERS FOLLOWING RECONNECTION. H8 LOW RETURN DROP WITH RETURN GRILLE TO IV CLEAN AND ANTE ROOMS. LOCATE BOTTOM OF GRILLE AT 6 INCHES AFF. PROVIDE 10"18" TYPE E GRILLE BALANCED TO 355 CFM FOR ANTE ROOM AND 10"X12" TYPE E GRILLE BALANCED TO 180 CFM FOR CLEAN ROOM. H9 EXISTING DUCTS NEED TO BE REPLACED WHERE LINED, AND FIRE SMOKE DAMPERS (INDICATED BUT NOT EXISTING) NEED TO BE INSTALLED. ADDITIONALLY SHAFT NEEDS TO BE SEALED. H10 COORDINATE WITH STRUCTURAL FOR BEAM PENETRATION ALONG COLUMN LINE J. EXISTING BOTTOM OF STRUCTURE IS APPROXIMATELY 8'6". H12 ADD ALTERNATE 2: REPLACE PNEUMATIC CONTROLS WITH DDC CONTROLS AT THE MRI ROOM AND (2) OFFICES IN THE PHARMACY AREA. PROVIDE SEQUENCES POINTS AND ALARMS TO MATCH NEW TERMINAL BOXES IN THE AREA. RECORD THE EXISTING BOX SETPOINTS PRIOR TO TAKING OUT OF OPERATION FOR REPLACEMENT AND TRANSFER SETPOINT TO NEW DDC CONTROLS. H15 DEMO EXISTING EXHAUST FAN IN EAST WING AND RESERVE AS INDICATED FROM NEW SYSTEM. REBALANCE EACH EXISTING EXHAUST GRILLE TO 100 CFM. H18 RELOCATE EXISTING GRD AND EXTEND DUCTWORK TO NEW LOCATION TO COORDINATE WITH NEW ARCHITECTURAL CEILING GRID. H19 PERFORM PRE-READS FOR THE EXISTING SUPPLY AND RETURN HVAC SYSTEM AND REPORT VALUES TO ENGINEER. REBALANCE ENTIRE EXISTING SUPPLY AND RETURN SYSTEM TO MATCH PRE-READS WITH EXCEPTION OF GRILLED INDICATED BY THIS KEYNOTE. FOR GRILLES INDICATED BY THIS KEYNOTE REBALANCE TO THE NEW (RB) INDICATED FLOW. H20 OMIT SUPPLY DUCTWORK INSULATION (ABOVE NUC MED ONLY) DUE TO SPACE RESTRAINTS. H21 SEAL ALL NEW AND EXISTING PENETRATIONS THROUGH FIRE RATED WALL. WALL WAS NOT PREVIOUSLY RATED. PROVIDE FIRE DAMPER IN EXISTING DUCT PENETRATIONS. REVIEW EXISTING DUCT SIZES PRIOR TO ORDER. Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC PIPING, AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA. SCALE: 1/8" = 1'-0" LEVEL 1 HVAC PLAN - CENTRAL SCALE: 1/8" = 1'-0" LEVEL 1 HVAC PLAN - PHARMACY SCALE: 1/8" = 1'-0" LEVEL 2 HVAC PLAN 06/30/17