HomeMy WebLinkAboutB17-0092_M-111-1_1508947706.pdfT FC 1-1 6"∅100 CFM 6"∅ 12/12 UP TO EF-8 14/1214/12 14/10 12/10 12/8 CUH 10/10 10/8 10/8 8/8 12/1012/10 8/8 8/8 10/8 8/108/8 8/8 30/18460 14/830/18D DHC-8 14/1424/14 30/122/10 18/101 24/14 18/10 1 12/12 460 CAP FO FUTUR 8 1 16/14 10/8 STEADMAN IT ROOM AHU-14 (E) EF 160 360 70 60 100 HH T AC 1 (E)112 VAV (E)114 VAV (E)113 VAV (E)102 VAV (E)109 VAV (E)105 VAV (E)101 VAV (E)115 VAV (E)104 VAV (E)103 VAV (E)108 VAV (N)109A VAV 50"x12"10"50"x12"36"x12" 24"x12" 60"x30"16"x12"10"x8"10"x12" 20"x12"12"x12"16"x12"16"x12" (N)102A VAV 8"A 200 (TYP. OF 2) (N)105A VAV 8"A 150 8"A 150 (TYP. OF 2) 120 220 14" 8" / 8"B 100 (E) EXHAUST UP (E)111 VAV (N)107A VAV (R)107 VAV H3 H4 H7 (N)108A VAV Q4 8"A 150 (TYP. OF 4) 28"x12"34"x12" 30"x10" 12"x10"24"x10"10"A 335 (TYP. OF 5) 8"A 95 8"A 100 8" 160 A 8" / 8"C 235 8" / 8"B 75 8" / 8"B 75 H15 H15 12"x10" 10"x8" 8"14"x6"14"x6"75 22" / 10"B 125 8"B 150 110 100 75 75 100 155 60 65 170 160 90 90 90 90 120 1000 1000 1000 500 500 150 160 175 85 130 335 90 90 120 90 12"x10"8"x8"130 H18 H18 150 H18 8"B 150 H1812"x10"8"B 150 (TYP. OF 2) 100 8"B 150 150 80 150 858"A 130 8"A 100 (TYP. OF 3) 30 300 8" 8"A 200 H18 150 14"14" 14"14"14"20"x10"20"x14" THIS ELBOW IS NOT EXISTING AND NEEDS TO BE REPLACED. B 120 22" / 10" (TYP. OF 3) 16"x10" (E)110 VAV (E)106 VAV NEW FSD 16"x10"790 22" / 22"B (TYP. OF 2) 8"x8" H20 50 H18 H18 B 100 22" / 10" 8"A 100 R1 H Q7 Q7 H18 H18 H18 H18 H18 H18 H18 H18 H18 H18 H18 1 130 130H18 H18 2 8"A 150 8"A 100 85 REBAL. TO 160 CFM REBAL. TO 150 CFM 8"B 160 H18 H18 H18 10"x4"10014"x10"24"x10"20"x10"16"x10" 32"x16" 34"x16"24"x10"24"x14"CHEMO HOOD EXHAUST UP THRU ROOF 14" 40"x14" 40"x14" H8 H7H7 H7 H7 H7 H7 H7 H7 H7 H7 H7 H7 H7 H9 H9 REMOVE THE CV CONTROL DAMPER ON L4. REPLACE W/ SPOOL PIECE. 8'-6" B.O.S. STACKED SA & RA MAINS 1-2-24 VAV 1-2-25 VAV 1-2-23 VAV 1-2-21 VAV 1-2-22 VAV 40"x14" 40"x14"40"x14"20"x14"18"x16" H10 H12 H12 8"F 0 (TYP. OF 2) 12"F 480 10"F 355 8"A 150 10"A 300 (TYP. OF 2) 8" 100 A 8"A 100 10"A 300 B 300 22" / 10" 10" 250 22" / 10"B B 650 22" / 22"20"x14" 14"x10" 8"x10" 40"x14"24"x10"14"x14"CHEMO HOOD DOWN TO HOOD RELOCATE EXISTING MINOR DRAIN PIPING IN THIS AREA TO ACCOMODATE DUCT ROUTING 24"x10" 24"x10" 24"x10"20"x10"16"x10"20"x10"14"x10"14"x10"28"x10"28"x10"28"x10"18"x10"210 220 200 200 210 200 200 240 210 210 190 190 200 200 200 240 130 80 130 700 230 H18(RB) 100 CFM (RB) 215 CFM (RB) 75 CFM (RB) 70 CFM (TYP. 2) H19 H19 H19 (RB) 115 CFM H21 (RB) 120 CFMH18 H18 H18 H19 110 110 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/10/2017 1:59:47 PM15924.00 M-111.1 LEVEL 1 AND 2 HVAC PLANS - CENTRAL 07/11/17PERMIT RESUBMISSION EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657A B C KEYNOTES H3 REPLACE EXISTING FAN AS SCHEDULED AND AS INDICATED ON ROOF PLAN. REBALANCE SYSTEM AND ALL GRILLES TO INDICATED AIRFLOWS. H4 RELOCATE EXISTING VAV BOX AND HEATING WATER COIL AND RECONNECT H7 PRIOR TO DEMOLITION, SUBMIT TEST AND BALANCE PRE-READS FOR THIS EXISTING EQUIPMENT AND REBALANCE EXISTING TERMINAL BOXES, GRILLES, REGISTERS, AND DIFFUSERS FOLLOWING RECONNECTION. H8 LOW RETURN DROP WITH RETURN GRILLE TO IV CLEAN AND ANTE ROOMS. LOCATE BOTTOM OF GRILLE AT 6 INCHES AFF. PROVIDE 10"18" TYPE E GRILLE BALANCED TO 355 CFM FOR ANTE ROOM AND 10"X12" TYPE E GRILLE BALANCED TO 180 CFM FOR CLEAN ROOM. H15 DEMO EXISTING EXHAUST FAN IN EAST WING AND RESERVE AS INDICATED FROM NEW SYSTEM. REBALANCE EACH EXISTING EXHAUST GRILLE TO 100 CFM. H18 RELOCATE EXISTING GRD AND EXTEND DUCTWORK TO NEW LOCATION TO COORDINATE WITH NEW ARCHITECTURAL CEILING GRID. H19 PERFORM PRE-READS FOR THE EXISTING SUPPLY AND RETURN HVAC SYSTEM AND REPORT VALUES TO ENGINEER. REBALANCE ENTIRE EXISTING SUPPLY AND RETURN SYSTEM TO MATCH PRE-READS WITH EXCEPTION OF GRILLED INDICATED BY THIS KEYNOTE. FOR GRILLES INDICATED BY THIS KEYNOTE REBALANCE TO THE NEW (RB) INDICATED FLOW. H20 OMIT SUPPLY DUCTWORK INSULATION (ABOVE NUC MED ONLY) DUE TO SPACE RESTRAINTS. H21 SEAL ALL NEW AND EXISTING PENETRATIONS THROUGH FIRE RATED WALL. WALL WAS NOT PREVIOUSLY RATED. PROVIDE FIRE DAMPER IN EXISTING DUCT PENETRATIONS. REVIEW EXISTING DUCT SIZES PRIOR TO ORDER. Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC PIPING, AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA. Q7 RELOCATE EXISTING PACKAGED HUMIDIFIER STEAM GENERATOR AND STEAM GRID FROM 2014 CATH LAB PROJECT FOR REUSE FOR THIS PROJECT. INSTALL PER MANUFACTURER INSTALLATION INSTRUCTIONS. COORDINATE ANY REQUIRED BACKING WITH HUMIDIFIER WEIGHT. PROVIDE DRAIN COOLER TO (E) MSB, GANGING MULTIPLE DRAINS FROM STEAM GENERATOR INTO SINGLE DRAIN COOLER VIA SPILL FUNNEL. ROUTE DUCT DRAIN TO 104E SOILED HOLD, NO DRAIN COOLER REQUIRED. SCALE: 1/8" = 1'-0" LEVEL 1 HVAC PLAN - CENTRAL SCALE: 1/8" = 1'-0" LEVEL 1 HVAC PLAN - PHARMACY SCALE: 1/8" = 1'-0" LEVEL 2 HVAC PLAN ADDENDUM 1 05/23/2017 1 ADDENDUM 4 07/06/2017 2 10/25/17