HomeMy WebLinkAboutB17-0092_M-111-1_1508947706.pdfT
FC
1-1
6"∅100 CFM
6"∅
12/12 UP
TO EF-8 14/1214/12 14/10 12/10 12/8
CUH
10/10
10/8
10/8
8/8 12/1012/10
8/8
8/8
10/8 8/108/8
8/8 30/18460
14/830/18D
DHC-8
14/1424/14
30/122/10 18/101
24/14
18/10
1
12/12
460
CAP FO
FUTUR
8
1
16/14
10/8
STEADMAN IT ROOM
AHU-14
(E) EF
160
360
70
60
100 HH
T
AC
1
(E)112
VAV
(E)114
VAV
(E)113
VAV
(E)102
VAV
(E)109
VAV
(E)105
VAV
(E)101
VAV
(E)115
VAV
(E)104
VAV (E)103
VAV (E)108
VAV
(N)109A
VAV 50"x12"10"50"x12"36"x12" 24"x12"
60"x30"16"x12"10"x8"10"x12" 20"x12"12"x12"16"x12"16"x12"
(N)102A
VAV
8"A 200
(TYP. OF 2)
(N)105A
VAV
8"A 150
8"A 150
(TYP. OF 2)
120
220
14"
8" / 8"B 100
(E) EXHAUST
UP
(E)111
VAV
(N)107A
VAV
(R)107
VAV
H3
H4
H7
(N)108A
VAV
Q4
8"A 150
(TYP. OF 4)
28"x12"34"x12"
30"x10" 12"x10"24"x10"10"A 335
(TYP. OF 5)
8"A 95
8"A 100
8"
160 A
8" / 8"C 235
8" / 8"B 75
8" / 8"B 75
H15 H15
12"x10"
10"x8" 8"14"x6"14"x6"75
22" / 10"B
125
8"B 150
110
100
75
75
100
155
60
65
170
160
90
90
90
90
120
1000 1000 1000
500 500
150 160
175
85
130
335
90
90
120
90
12"x10"8"x8"130
H18 H18
150
H18
8"B 150
H1812"x10"8"B 150
(TYP. OF 2)
100
8"B 150
150
80
150
858"A 130
8"A 100
(TYP. OF 3)
30
300
8" 8"A 200
H18
150 14"14"
14"14"14"20"x10"20"x14" THIS ELBOW IS NOT
EXISTING AND NEEDS TO BE
REPLACED.
B 120
22" / 10"
(TYP. OF 3)
16"x10"
(E)110
VAV
(E)106
VAV
NEW FSD
16"x10"790
22" / 22"B
(TYP. OF 2)
8"x8"
H20
50
H18
H18
B 100
22" / 10"
8"A 100
R1
H
Q7
Q7
H18
H18
H18
H18
H18
H18
H18
H18
H18
H18
H18
1
130
130H18
H18
2
8"A 150
8"A 100
85
REBAL. TO 160 CFM
REBAL. TO 150 CFM
8"B 160
H18
H18
H18 10"x4"10014"x10"24"x10"20"x10"16"x10"
32"x16"
34"x16"24"x10"24"x14"CHEMO HOOD
EXHAUST UP THRU
ROOF
14"
40"x14"
40"x14"
H8
H7H7
H7 H7
H7 H7
H7
H7 H7 H7
H7
H7
H7
H9
H9
REMOVE THE CV CONTROL
DAMPER ON L4. REPLACE W/
SPOOL PIECE.
8'-6" B.O.S.
STACKED SA & RA
MAINS
1-2-24
VAV
1-2-25
VAV
1-2-23
VAV
1-2-21
VAV
1-2-22
VAV
40"x14" 40"x14"40"x14"20"x14"18"x16"
H10
H12
H12
8"F 0
(TYP. OF 2)
12"F 480
10"F 355
8"A 150
10"A 300
(TYP. OF 2)
8"
100 A
8"A 100
10"A 300
B 300
22" / 10"
10"
250
22" / 10"B
B 650
22" / 22"20"x14"
14"x10"
8"x10"
40"x14"24"x10"14"x14"CHEMO HOOD DOWN TO HOOD RELOCATE EXISTING MINOR
DRAIN PIPING IN THIS AREA TO
ACCOMODATE DUCT ROUTING
24"x10"
24"x10" 24"x10"20"x10"16"x10"20"x10"14"x10"14"x10"28"x10"28"x10"28"x10"18"x10"210
220
200
200
210
200
200
240
210
210
190
190
200
200
200
240
130
80
130
700
230
H18(RB) 100 CFM
(RB) 215 CFM
(RB)
75
CFM
(RB)
70 CFM
(TYP. 2)
H19
H19
H19
(RB)
115 CFM
H21
(RB)
120
CFMH18
H18
H18
H19
110
110
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL WING RENOVATION
7/10/2017 1:59:47 PM15924.00
M-111.1
LEVEL 1 AND 2 HVAC
PLANS - CENTRAL
07/11/17PERMIT
RESUBMISSION
EAST WING
ADDITION
180 S Frontage Rd W, Vail, CO 81657A
B
C
KEYNOTES
H3 REPLACE EXISTING FAN AS SCHEDULED AND AS INDICATED ON
ROOF PLAN. REBALANCE SYSTEM AND ALL GRILLES TO INDICATED
AIRFLOWS.
H4 RELOCATE EXISTING VAV BOX AND HEATING WATER COIL AND
RECONNECT
H7 PRIOR TO DEMOLITION, SUBMIT TEST AND BALANCE PRE-READS
FOR THIS EXISTING EQUIPMENT AND REBALANCE EXISTING
TERMINAL BOXES, GRILLES, REGISTERS, AND DIFFUSERS
FOLLOWING RECONNECTION.
H8 LOW RETURN DROP WITH RETURN GRILLE TO IV CLEAN AND ANTE
ROOMS. LOCATE BOTTOM OF GRILLE AT 6 INCHES AFF. PROVIDE
10"18" TYPE E GRILLE BALANCED TO 355 CFM FOR ANTE ROOM AND
10"X12" TYPE E GRILLE BALANCED TO 180 CFM FOR CLEAN ROOM.
H15 DEMO EXISTING EXHAUST FAN IN EAST WING AND RESERVE AS
INDICATED FROM NEW SYSTEM. REBALANCE EACH EXISTING
EXHAUST GRILLE TO 100 CFM.
H18 RELOCATE EXISTING GRD AND EXTEND DUCTWORK TO NEW
LOCATION TO COORDINATE WITH NEW ARCHITECTURAL CEILING
GRID.
H19 PERFORM PRE-READS FOR THE EXISTING SUPPLY AND RETURN
HVAC SYSTEM AND REPORT VALUES TO ENGINEER. REBALANCE
ENTIRE EXISTING SUPPLY AND RETURN SYSTEM TO MATCH
PRE-READS WITH EXCEPTION OF GRILLED INDICATED BY THIS
KEYNOTE. FOR GRILLES INDICATED BY THIS KEYNOTE REBALANCE
TO THE NEW (RB) INDICATED FLOW.
H20 OMIT SUPPLY DUCTWORK INSULATION (ABOVE NUC MED ONLY) DUE
TO SPACE RESTRAINTS.
H21 SEAL ALL NEW AND EXISTING PENETRATIONS THROUGH FIRE
RATED WALL. WALL WAS NOT PREVIOUSLY RATED. PROVIDE FIRE
DAMPER IN EXISTING DUCT PENETRATIONS. REVIEW EXISTING DUCT
SIZES PRIOR TO ORDER.
Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC
PIPING, AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA.
Q7 RELOCATE EXISTING PACKAGED HUMIDIFIER STEAM GENERATOR
AND STEAM GRID FROM 2014 CATH LAB PROJECT FOR REUSE FOR
THIS PROJECT. INSTALL PER MANUFACTURER INSTALLATION
INSTRUCTIONS. COORDINATE ANY REQUIRED BACKING WITH
HUMIDIFIER WEIGHT. PROVIDE DRAIN COOLER TO (E) MSB, GANGING
MULTIPLE DRAINS FROM STEAM GENERATOR INTO SINGLE DRAIN
COOLER VIA SPILL FUNNEL. ROUTE DUCT DRAIN TO 104E SOILED
HOLD, NO DRAIN COOLER REQUIRED.
SCALE: 1/8" = 1'-0"
LEVEL 1 HVAC PLAN - CENTRAL
SCALE: 1/8" = 1'-0"
LEVEL 1 HVAC PLAN - PHARMACY
SCALE: 1/8" = 1'-0"
LEVEL 2 HVAC PLAN
ADDENDUM 1 05/23/2017 1
ADDENDUM 4 07/06/2017 2
10/25/17