HomeMy WebLinkAboutB17-0092_M-121-1_1498849080.pdf~ ~ ~~
~
~~
~~
HWR
3/4" HWS
1" R
1" S
(E)
H
(E) 5" HWS/R &
5" CWS/R UP
LPS UP
DN
FC
1-1
AC
2
CUH
1
CWR
CWR
CWR
CWR CWR
CWR CWS
CWS
CWS
CWS CWS
CWS HWR
HWR
HWR
HWR HWR
HWR
HWR
HWR
HWR
HWS
HWS
HWS
HWS HWS
HWS HWS
HWS HWS
HR
HS
CAP FO
FUTUR
1r"
1r"
CUH
CWS
CWR D
s"
1"
s"
1"
s"HWS UP
TO FTR
s"HWR UP
TO FTR
s"HWS UP
TO FTR
s"HWR UP
TO FTR
HWS
HWR
FCU
3"
2i"
P-9 P-1
WATER HEATER
HWR
HWR
HWS
HWS
HWR
3" HWS/HWR UP TO
SECOND FLOOR
(NO
3"
BO
PEE
s" HWR
HWS
HWS
HWR
AC-3
H-1
4"
3/4"
1"
3/4"
4" 5"
5" 2" 1"
3/4"
3/4"
3/4"
3/4"
1" 1"
3/4"
3/4"
3/4"
1 1/4"
3/4"
1"
3/4"
3/4"
3/4"
3/4"
2"MPS UP H
H
1 1/2" HWR
2 1/2" HWS
1 1/2" HWR
2 1/2" HWS
3" S
3" R
2 1/2" HWS
1 1/2" HWR
2" HWR
2" HWS
2" HWS
T
T
T
T
T
T
T
T
T
T
T
T
T
(E)101
VAV
(E)115
VAV
(N)105A
VAV
(E)104
VAV
(E)103
VAV
(N)102A
VAV
(E)114
VAV
(E)102
VAV
(N)109A
VAV
(E)109
VAV
(E)110
VAV
(E)106
VAV
(E)111
VAV
(E)112
VAV
(E)108
VAV
(E)113
VAV
(E)105
VAV
(R)107
VAV
(N)107A
VAV
N1
H
H
CONNECT TO (E) STEAM
1" LPS
Q2
Q3
T
Q4
T
Q3
Q2
T
Q2
T
T
Q2
3/4" HWS
3/4" HWR
(N)108A
VAV
T
PROVIDE DRAIN COOLER. SIZE AS RECOMMENDED
BY HUMIDIFIER MANUFACTURER. ROUTE ANY
REQUIRED STEAM TRAPS TO THIS DRAIN COOLER.
3/4" LPC
10' - 0"
1
RCP
10' - 0"
1
RCP
6' - 0"
1
RCP
10' - 0"
1
RCP
ALL HEATING WATER SUPPLY AND
RETURN PIPING 3/4" UNLESS
NOTED OTHERWISE
T
Q1
T
T
T
P
T
COORD. LOCATION
OF NEW TSTAT
WITH EXISTING
RETAIL PHARMACY
1-2-21
VAV
1-2-23
TB
1-2-24
VAV
1-2-25
VAV
1-2-22
VAV
H12
H12
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
9:33:58 AM
180 S. Frontage
Road
West,
Vail, CO 81657
15924.00
M-121.1
LEVEL 1 HVAC PIPING PLAN
- CENTRAL
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
A
B
C
KEYNOTES
H12 ADD ALTERNATE 2: REPLACE PNEUMATIC CONTROLS WITH DDC
CONTROLS AT THE MRI ROOM AND (2) OFFICES IN THE PHARMACY
AREA. PROVIDE SEQUENCES POINTS AND ALARMS TO MATCH NEW
TERMINAL BOXES IN THE AREA. RECORD THE EXISTING BOX
SETPOINTS PRIOR TO TAKING OUT OF OPERATION FOR
REPLACEMENT AND TRANSFER SETPOINT TO NEW DDC CONTROLS.
Q1 PROVIDE (3) ROOM PRESSURE MONITORS MONITORED AND TRENDED
BY BAS. GANG INDICATORS AT INDICATED LOCATION. PRESSURE
DIFFERENTIALS WILL BE MONITORED BETWEEN THE CLEAN ROOM
AND ANTE, BETWEEN THE CHEMO ROOM AND ANTE, AND BETWEEN
THE ANTE ROOM AND ADJACENT NON USP-800 PHARMACY. PROVIDE
TEMPORARY LABELS INDICATING WHICH ROOM IS MONITORED BY
WHICH PRESSURE MONITOR. FINAL LABELS WILL BE PROVIDED AND
INSTALLED BY OWNER.
Q2 EXISTING THERMOSTAT TO REMAIN IN EXISTING LOCATION.
Q3 RELOCATE EXISTING THERMOSTAT TO LOCATION INDICATED.
Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC PIPING,
AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA.
SCALE: 1/8" = 1'-0"
LEVEL 1 HVAC PIPING PLAN - CENTRAL
SCALE: 1/8" = 1'-0"
LEVEL 1 HVAC PIPING PLAN - PHARMACY
06/30/17