Loading...
HomeMy WebLinkAboutB17-0092_M-401-1_1498849080.pdfH ~ LPC LPS T 810-06 SCALE: NONE AIR FLOW 6" 24" TO 36" MIN 54" PITCH HIGH LIMIT HUMIDISTAT F&T PITCH F&T ALUMINUM DUCTWORK SEALED WATERTIGHT WITH SEAMS ON TOP OR AT LEAST 2" ABOVE BOTTOM OF DUCT ACCES S DOOR MIN 2" DDC COMPATIBLE MODULATING VALVE MINIMUM DISTANCE TO FIRST FITTING NOTES: 1. 2. INSULATE STEAM PIPING AND CONTROL VALVE. PROVIDE HUMIDIFIER WITH INSULATED TUBES. AIR FLOW SAIL SWITCH 36" 6" EQUAL TO DUCT STATIC PRESSURE CLASS (INCHES) TEMPERATURE SWITCH TO PREVENT VALVE OPERATION IF HEAT EXCHANGER IS NOT HOT DUCT FLANGE CONNECTION, SEAL WATERTIGHT (TYP.) TO NEARBY FLOOR DRAIN TO BUILDING STEAM CONDENSATE RETURN SYSTEM FROM BUILDING STEAM SYSTEM INSULATION TO FULLY COVER HUMIDIFER CASING AND HEAT EXCHANGER DUCT DRAIN SUMP 4" DRIP DUCT HUMIDIFIER (WITH CONDENSATE LIFT FEATURE) PIPING DETAIL 830-12 HOT WATER REHEAT COIL PIPING DETAIL NOTE: INSTALL HWS PIPING ON LEAVING AIR SIDE OF COIL. SCALE: NONE HOT COIL WATER FLOW AIR P/T UNION OR FLANGE FOR STEEL PIPE ONLY. NOT REQUIRED FOR COPPER (TYP.) P/T MANUAL VENT VALVE DRAIN VALVE WITH HOSE END CONNECTION AND CAP NOTE: ARRANGE PIPING TO ALLOW COIL REMOVAL. 3/4" HWS HWS MAIN HWR CALIBRATED BALANCING VALVE HWR MAIN HWS ~ ~ 830-30 RADIANT HEATING CEILING PANEL PIPING DETAIL SCALE: NONE CALIBRATED BALANCE VALVE HWR P/T SOFT COPPER PIPING CONNECTIONS BETWEEN PANELS (TYP.) 2-WAY TCV HWS P/T UNION OR FLANGE FOR STEEL PIPE ONLY. NOT REQUIRED FOR COPPER (TYP.) RADIANT CEILING PANEL PROVIDE 2" RIGID WITH FOIL FACE FIBERGLASS BATT INSULATION ABOVE RADIANT PANELS 850-12 EF-16 ROOF EXHAUST FAN DETAIL SEAL DUCT PENETRATION PREFABRICATED ROOF CURB SCALE: NONE PROVIDE DRAIN AT BOTTOM OF FAN SCROLL A"Ø 15'-0" TOTAL STACK HEIGHT ISOLATION PER SPECS. EXHAUST FAN APPROX. OUTLET SIZE: C"XD" B"Ø PROVIDE 3-POINT GUY WIRE SUPPORT AT 8'-0" & 13'-0" ABOVE ROOF BRACKET UPPER STACK TO DISCHARGE DUCT FLEXIBLE CONNECTION DUCT SUPPORT 36" SEE ARCH. FOR ROOF DETAILS 1" GAP ALL AROUND 891-1 DUCT ROOF PENETRATION DETAIL SCALE: NONE PREFABRICATED INSULATED CURB DUCT ROOF COUNTERFLASHING ROOFING SYSTEM. SEE ARCH. EXTERIOR DUCT JOINT PER SMACNA 891-5 ROOF DUCT SUPPORT DETAIL, ROUND 3/16" WELDED SOLE PLATE AND ATTACHMENT BOLTS SCALE: NONE DIAGONAL BRACING DUCT INSULATION AND JACKETING PER SPECIFICATIONS 16 GA. SHEET METAL HOLD DOWN STRAP SECURED W/SHEET METAL SCREW FASTENER ANCHOR BOLTS, LOCATE IN DECK AS REQUIRED BY STRUCTURAL ENGINEER CHANNEL STRUT. HOT DIPPED GALVANIZED AFTER FABRICATION PRE-FABRICATED EQUIPMENT RAIL SUPPORT ANCHOR TO STRUCTURE PER MFR'S INSTRUCTIONS RE: ARCH. FOR ROOFING DETAIL AND WATER PROOFING REPAIR ALL FIELD CUTS AND WELDS WITH ZINC RICH PAINT, FINISH WITH TWO COATS OF OUTDOOR FINISH PAINT AS SELECTED BY ARCHITECT 891-11 DUCT PASSING UNDER BEAM SCALE: NONE RADIUS BEAM FLOOR 910-1 FIRE DAMPER INSTALLATION DETAIL SCALE: NONE MOUNTING/RETAINING ANGLES INSTALLED PER MFR'S INSTALLATION INSTRUCTIONS NOTE: VERTICAL TYPE FIRE DAMPER SHOWN. FOR HORIZONTAL TYPE, TURN ASSEMBLY 90° AND PROVIDE W/NEGATOR CLOSURE SPRING. AIR FLOW PROVIDE SLEEVE GAUGE STEEL FIRE DAMPER SLEEVE, THICKNESS PER MFR'S INSTALLATION INSTRUCTIONS FOR HORIZONTAL FIRE DAMPERS LOCATE DUCT ACCESS DOOR FROM ABOVE TO ACCESS NEGATOR CLOSURE SPRING BREAKAWAY JOINTS, BOTH SIDES OF DAMPER SLEEVE PROVIDE MULTIPLE ACCESS DOORS FOR DUCTWORK 60" OR WIDER OR ON SIDE OF DUCT WHEN REQUIRED TO PROVIDE ADEQUATE ACCESS TO FIRE DAMPER FIRE DAMPER INSTALLATION NOTE: M.C. SHALL PROVIDE & INSTALL ADDITIONAL STEEL MULLIONS PER MFR INSTALLATION INSTRUCTIONS FOR MULTIPLE FIRE DAMPER ASSEMBLIES. MAINTAIN EXPANSION CLEARANCE PER MFR'S INSTALLATION INSTRUCTIONS 910-2 DUCT TAKE-OFF DETAIL RETURN OR EXHAUST AIR FLOW SCALE: NONE SUPPLY AIR FLOW RETURN OR EXHAUST AIR FLOW SUPPLY AIR FLOW BRANCH DUCT 45° MAXIMUM A MAIN DUCT 910-7 SPLITTER DUCT DETAIL C/D (AS SHOWN ON PLAN) E/F (AS SHOWN ON PLAN) TURNING VANES (TYP.) SCALE: NONE SEE PLAN FOR SIZES. NOTE: TRANSITION IF REQUIRED E/B C/B E C TRANSITION IF REQUIRED A/B (AS SHOWN ON PLAN) TRANSITION TO E+C/B 910-9 MEDIUM PRESSURE MVD DETAIL GROUND END TO 1/2" SQUARE FOR WRENCH ADJUSTMENT 3/4" THREADED ROD SCALE: NONE 12 GA. PLATE D GASKET (NEOPRENE) NUT WASHER LOCKNUT D-1" LOCATE DUCT ACCESS DOOR TO SERVICE INTERNAL LINKAGE, ACTUATOR, AND/OR CONTROLS AS REQUIRED. WHERE APPLICABLE, DUCT SMOKE DETECTOR. LOCATE ON SAME SIDE OF DAMPER AS ACCESS DOOR. 910-11 FIRE/SMOKE DAMPER INSTALLATION DETAIL NOTES: 1. INSTALL ASSEMBLY IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2. PROVIDE AND INSTALL ADDITIONAL STEEL MULLIONS FOR MULTIPLE FIRE/SMOKE DAMPER ASSEMBLIES. 3. PROVIDE APPROPRIATE DUCT TRANSITIONS BETWEEN SCHEDULED DAMPER SIZE AND INDICATED DUCT SIZE. 4. PROVIDE RED IDENTIFICATION PAINT ON EXTERIOR OF DAMPER SLEEVE. SCALE: NONE MOUNTING/RETAINING ANGLES INSTALLED PER MFR'S INSTALLATION INSTRUCTIONS ACTUATOR OUT OF AIRSTREAM MANUAL RESET THERMAL SWITCH FIRE/SMOKE DAMPER PROVIDE MULTIPLE ACCESS DOORS FOR DUCTWORK 60" OR WIDER OR ON SIDE OF DUCT WHEN REQUIRED TO PROVIDE ADEQUATE ACCESS TO FIRE DAMPER BREAKAWAY JOINTS, BOTH SIDES OF DAMPER SLEEVE MAINTAIN EXPANSION CLEARANCE PER MFR'S INSTALLATION INSTRUCTIONS 932-11 AIR DEVICE WITH RECTANGULAR NECK & ROUND RUNOUT BOOT DETAIL SCALE: NONE CEILING NOTE: REGISTERS AND GRILLES SIMILAR. SHEET METAL DUCTWORK, INSULATED PER SPECIFICATIONS BELLMOUTH TYPE SPIN-IN WITH BUTTERFLY TYPE MVD, EXTEND QUADRANT HANDLE THRU INSULATION AND SEAL AROUND INSULATION. INSULATE RUN-OUT PER SPECIFICATIONS STAINLESS STEEL WORM GEAR CLAMP ON BOTH THE FLEX DUCT JACKET AND INNER CORE. T-BAR OR LAY-IN FRAME FOR HARD CEILING. LAY-IN AIR DEVICE FLEXIBLE DUCT (MAX. 6'-0") SUPPORT @ 3'-0" O.C., INSULATED PER SPECIFICATIONS SUPPORT FROM OVERHEAD STRUCTURE EXTERNALLY INSULATED SHEET METAL PLENUM BOX OVER GRILLE PER SPECIFICATIONS ALTERNATE OPTIONAL CONNECTION METHOD AT TOP OF PLENUM SHEET METAL DUCT WHERE INDICATED ON PLANS 932-12B ROUND NECK AIR DEVICE DETAIL SCALE: NONE LONG RADIUS FLEXIBLE DUCT (MAX. 6'-0") SUPPORT @ 3'-0" O.C. INSTALLED PER SPECIFICATIONS NOTE: CEILING DIFFUSER SHOWN; REGISTERS AND GRILLES SIMILAR. CEILING LAY-IN AIR DEVICE SHEET METAL DUCTWORK, INSULATED PER SPECIFICATIONS. BELLMOUTH TYPE SPIN- IN WITH BUTTERFLY TYPE MVD, EXTEND QUADRANT HANDLE THRU INSULATION AND SEAL AROUND INSULATION. T-BAR OR LAY-IN FRAME FOR HARD CEILING. SUPPORT FROM OVERHEAD STRUCTURE INSTALL RUN-OUT PER SPECIFICATIONS STAINLESS STEEL WORM GEAR CLAMP ON BOTH THE FLEX DUCT JACKET AND INNER CORE. HARD CEILING INSTALLATIONS: 1. 2. PROVIDE LAY-IN FRAME TO ALLOW AIR DEVICE TO BE REMOVED. LOCATE MVD TO BE ACCESSIBLE. IF SPIN-IN IS NOT ACCESSIBLE PROVIDE A REMOTE OPERATED MVD. HARD CEILING INSTALLATIONS: 1. 2. PROVIDE LAY-IN FRAME TO ALLOW AIR DEVICE TO BE REMOVED. LOCATE MVD TO BE ACCESSIBLE. IF SPIN-IN IS NOT ACCESSIBLE PROVIDE A REMOTE OPERATED MVD. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 9:34:01 AM 180 S. Frontage Road West, Vail, CO 81657 15924.00 M-401.1 MECHANICAL DETAILS 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 06/30/17