HomeMy WebLinkAboutB17-0092_P-111-1_1508947714.pdf4"
W
4"
W
W4"
2"
W W2"
4"
W W
W
W SLOPESLOPE
SLOPE SLOPESLOPESLOPESLOPE
SLOPE
2"W UP
TO LAV
2"W UP
TO LAV
2"W UP
TO LAV
4"W UP
TO WC
2"V UP
2"W UP
TO LAV
4"W UP
TO WC
2"V UP
2"V UP2"W UP
TO SHWR
2"W UP
TO LAV
2"W UP
TO LAV
3"W UP
3"
2"W UP
2"W UP
TO LAVS
4"W UP
TO WC
2"V UPW
WW4"
4"
4"3"D2"
(E)3"VTR
(
2"
(E)3"VTR
2"
2"V ~~~ ~~~~~~~~WW
W
4"
2"
W
SL OPE
OPE
SLOPE
SLOPE
(E)
P-TDAC-3
3/4"BD
2"
2"
S-1
2"
1i"
4"WCO
2 1/2"3"
2 1/2"
2 1/2"
2"
4"
2 1/2"
(E) 4" W
1 1/2"
4"
4"
4"W1 1/2"
2"
W WW
WW WWWW4"W UP
2"W UP2"W UP
2"W UP
2"W UP
2"W UP
2"W UP
2"W UP
4"W UP
2"W UP
2"W UP
2"V UP
4"W DN
4"W DN
4"W UP FROM BELOW
4"
2"
4"
2"
2" 2"
2"
3"
2"
4"
2"W UP
2"
4"
2"
2"
4"W DOWN
4"W DOWN
4"
3"4"
4"W DN
4"W UP TO WC
2"W UP TO LAV
3"W UP TO MSB
2"W UP TO LAV
2"V UP
2"W UP TO FD
2"V UP
1-1/2" UP TO EWC
2"V UP
4"W UP TO WCO
4"W UP TO WC
2"W UP TO LAV
2"W UP TO SH
4"4"
4"
2" W UP
2"
2"V UP
4"W UP
TO WC
2"W UP
TO LAV
4"W UP
TO WC
2"W UP
TO LAV
W UP
O WC
V UP
UP
LAV
4"W UP
TO WC
2"V UP
2"W UP
TO LAV
W UP
O WC
V UP
UP
FCO WALL
WASTE RISER
CLEANOUT
(E) 4" V
4"
4"
2"
UP
4"W DN
W/WCO
2"V DN
2" W UP
2" W UP
2" W UP 4"W
2" W
TIE NEW 2"V
TO (E) 2"V UP
2" V
RELOCATE EXISTING WASTE AND VENT
PIPING AS REQUIRED TO COORDINATE
WITH NEW MEPT SYSTEMS AND
ARCHITECTURE.
2" V
1 1/2" V
1 1/2" V
2" W
1 1/2" V
2" W
TIE WC AND LAV
INTO (E) 4"W RISER
IF INVERT IS
POSSIBLE. IF NOT,
UTILIZE 6" BD FOR
WC AND 4"W RISER
FOR LAV ONLY
1 1/2" V
4" W
6" W
6" SD 6" OD
6" OD
6" SD
6" SD 6" OD
CONNECT TO (E)
6" BUILDING DRAIN
(E) 4" DRAIN
(E) 6" BUILDING
DRAIN
(E) 4"V UP
TIE (N) 2"W TO
(E) 2"W BELOW
SLAB
(N) WCO
(N) WCO
2"W UP
TO
SINK
4" W
2" W
1 1/2" V
4" W
2" V
3" W
2" W
2" V
P20
(N) WCO
4" W
4" W4" W
2" V 2" V2" V
1 1/2" V
1
(E) 2"W DOWN TO (E) 4"W BELOW1
(E) 4"W DOWN TO
(E) 4"W BELOW
(E) 2"W DOWN TO
(E) 4"W BELOW
1
1
2" W
1 1/2" V
(N) WCO
1
CONNECT NEW 2"W TO
SECTION OF EXISTING
2"W FORMERLY
CONNECTED TO EXISTING
SINK
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL WING RENOVATION
7/10/2017 2:00:57 PM15924.00
P-111.1
LEVEL 1 AND 2 WASTE &
VENT PLANS - CENTRAL
07/11/17PERMIT
RESUBMISSION
EAST WING
ADDITION
180 S Frontage Rd W, Vail, CO 81657A
B
C
SCALE: 1/8" = 1'-0"
LEVEL 1 WASTE & VENT PLAN - PHARMACY
SCALE: 1/8" = 1'-0"
LEVEL 2 WASTE & VENT PLAN - CENTRAL
KEYNOTES
SCALE: 1/8" = 1'-0"
LEVEL 1 WASTE & VENT PLAN - CENTRAL
2
ADDENDUM 1 05/23/2017 1
ADDENDUM 2 06/12/2017 2
10/25/17