Loading...
HomeMy WebLinkAboutB17-0092_P-121-1_1498849140.pdf~ ~~~ ~ ~ ~ ~~ ~ ~ CAP TYP. W W SD W W/CO 2 1/2" 3/4" WH 1" 2" 1 1/4" 3/4" 2" 1" 2 1/2" 3/4" 3/4" 1 1/4" 2" 1 1/2" 3/4" 1" 2" 1 1/4" 1" 1 1/2" 2" 1/2" S-1 S-1 S-2 SH-1 1" 2 1/2" 3/4" " 1/2" 3/4" 1/2" 3/4" 1/2" 3/4" 2" 1" 1 1/2" 2 1/2" 1" 1 1/4" 2 1/2" 2" 1 1/2" /2" 2" 1/2" 1 1/4" 1/2" 1/2" S-2 S-1 1" CW UP TO HUMIDIFIER CAPPED EWC-1 RECONNECT CW TO NEW EWC DN 1/2"CW DN TO WATER DISPENSER (BY OTHERS) s" s" i" 1r" i" 3/4" 3/4" 1/2" 2" 1/2" 1 1/4" 1/2" 1/2"CW/HW DN 1 1/4" 1" 1 1 1/2" 3/4" 2 1/2" HW 2" HWC 4" CW 2 1/2" HW 2" HWC 4" CW 2 1/2" HW 2" HWC 4" CW P15 P15 WC-1 L-1 L-1 L-1 WC-1 MSB-2 BALANCE TO 0.5 GPM CONNECT TO (E) RECIRC CONNECT TO (E) RECIRC S-14 W/EW Q4 P16 P18 P18 S-1 P19 1" CW 1" HW 3/4" CW 3/4" HWC 3/4" HW P21 BALANCE TO 0.5 GPM BALANCE TO 0.5 GPM S-14 W/EW S-12 DEMO FIXTURE, PIPING AND ANY DEAD LEGS BALANCE TO 0.5 GPM P18 (E) SINK (E) SINK (E) SINK (E) SINK WC-1 L-1 S-1 S-1 1" CW 1" CW 1/2" CW BALANCE TO 0.5 GPM P23 P23 P20 S-1 P23 P23 P18 P18 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 9:59:34 AM 180 S. Frontage Road West, Vail, CO 81657 15924.00 P-121.1 LEVEL 1 AND 2 DOMESTIC WATER PLANS - CENTRAL 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER A B C KEYNOTES P15 4" DOMESTIC WATER INTERCONNECTION BETWEEN WEST WING AND EAST WING, 2-1/2" HOT WATER, AND 2" HOT WATER RECIRC. REPLACE PIPING AS PART OF THE CENTRAL WING ENABLING WORK. PROVIDE VALVE AND CAP FOR FUTURE CONNECTION OF EAST WING PIPING. P16 REPLACE ALL EXISTING DOMESTIC WATER RECIRC PIPING WITHIN THIS SCOPE AREA. EXISTING PIPING HAS MULTIPLE PINHOLE LEAKS. P18 WITHIN BOUNDS OF RENOVATION SCOPE AREA, MODIFY THE EXISTING WET FIRE PROTECTION SYSTEM AS REQUIRED IN ACCORDANCE WITH NFPA-13 AND THE LOCAL AHJ REQUIREMENTS TO ACCOMODATE THE ARCHITECTURAL REMODEL. MODIFY EXISTING SPRINKLER ZONES TO MATCH LIFE SAFETY ZONING. MATCH EXISTING SPRINKLERS. P19 PROVIDE 3/8" DCW W/ANGLE STOP SHUT-OFF VALVE AND 72" OF 3/8" SOFT COPPER TUBING FROM BELOW COUNTER SINK DCW SUPPLY. CONNECT TO ICE MAKER, COFFEE MAKER, AND WATER FILLER ABOVE COUNTER TOP. P20 DEMO EXISTING STUDOR VENT SERVING BREAK ROOM SINK. PROVIDE NEW 1-1/2"V FOR EXISTING BREAK ROOM SINK. P21 RELOCATE EXISTING SINK AND FAUCET TO NEW LOCATION IN NUCLEAR MEDICINE CAMERA ROOM. DEMO DCW DHW VENT AND WASTE BACK TO MAINS WHERE EXISTING SINK IS BEING REMOVED FROM EXISTING LOCATION. PROVIDE NEW CONNECTIONS AT NEW LOCATION AS DESCRIBED FOR FIXTURE S-12. LEAVE NO DEADLEGS. P23 REPLACE EXISTING CORRODED WRIST-BLADE FAUCET HANDLES FOR INDICATED SINKS. EXISTING FAUCETS ARE 2 CORE T&S BRASS ON 4" CENTERS. Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC PIPING, AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA. SCALE: 1/8" = 1'-0" LEVEL 1 DOMESTIC WATER PLAN - CENTRAL SCALE: 1/8" = 1'-0" LEVEL 1 DOMESTIC WATER PLAN - PHARMACY SCALE: 1/8" = 1'-0" LEVEL 2 DOMESTIC WATER PLAN - CENTRAL 06/30/17