HomeMy WebLinkAboutB17-0092_P-121-1_1498849140.pdf~
~~~
~
~
~
~~
~
~
CAP TYP.
W
W SD W W/CO
2 1/2"
3/4"
WH
1"
2"
1 1/4"
3/4"
2"
1"
2 1/2"
3/4"
3/4" 1 1/4"
2"
1 1/2"
3/4"
1"
2"
1 1/4"
1"
1 1/2" 2"
1/2"
S-1
S-1
S-2
SH-1
1"
2 1/2"
3/4"
" 1/2" 3/4"
1/2"
3/4"
1/2"
3/4"
2"
1"
1 1/2"
2 1/2"
1"
1 1/4"
2 1/2"
2"
1 1/2"
/2"
2"
1/2"
1 1/4"
1/2"
1/2"
S-2
S-1
1" CW UP TO
HUMIDIFIER
CAPPED
EWC-1
RECONNECT CW
TO NEW EWC
DN
1/2"CW DN TO WATER
DISPENSER (BY OTHERS)
s"
s"
i"
1r"
i"
3/4"
3/4"
1/2"
2"
1/2"
1 1/4"
1/2"
1/2"CW/HW DN
1 1/4"
1"
1
1
1/2"
3/4"
2 1/2" HW
2" HWC
4" CW
2 1/2" HW
2" HWC
4" CW
2 1/2" HW
2" HWC
4" CW
P15
P15
WC-1
L-1
L-1
L-1 WC-1
MSB-2
BALANCE
TO 0.5
GPM
CONNECT TO
(E) RECIRC
CONNECT TO
(E) RECIRC
S-14
W/EW
Q4
P16
P18
P18
S-1
P19
1" CW
1" HW
3/4" CW
3/4" HWC
3/4" HW
P21
BALANCE
TO 0.5 GPM
BALANCE
TO 0.5 GPM
S-14
W/EW
S-12
DEMO FIXTURE,
PIPING AND
ANY DEAD
LEGS BALANCE
TO 0.5 GPM
P18
(E) SINK
(E) SINK
(E) SINK
(E) SINK
WC-1
L-1
S-1
S-1
1" CW
1" CW
1/2" CW
BALANCE
TO 0.5 GPM
P23
P23
P20
S-1
P23
P23
P18
P18
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
9:59:34 AM
180 S. Frontage
Road
West,
Vail, CO 81657
15924.00
P-121.1
LEVEL 1 AND 2 DOMESTIC
WATER PLANS - CENTRAL
2017
03/10/17
PERMIT VAIL
VALLEY
MEDICAL
CENTER
A
B
C
KEYNOTES
P15 4" DOMESTIC WATER INTERCONNECTION BETWEEN WEST WING AND
EAST WING, 2-1/2" HOT WATER, AND 2" HOT WATER RECIRC. REPLACE
PIPING AS PART OF THE CENTRAL WING ENABLING WORK. PROVIDE
VALVE AND CAP FOR FUTURE CONNECTION OF EAST WING PIPING.
P16 REPLACE ALL EXISTING DOMESTIC WATER RECIRC PIPING WITHIN
THIS SCOPE AREA. EXISTING PIPING HAS MULTIPLE PINHOLE LEAKS.
P18 WITHIN BOUNDS OF RENOVATION SCOPE AREA, MODIFY THE
EXISTING WET FIRE PROTECTION SYSTEM AS REQUIRED IN
ACCORDANCE WITH NFPA-13 AND THE LOCAL AHJ REQUIREMENTS TO
ACCOMODATE THE ARCHITECTURAL REMODEL. MODIFY EXISTING
SPRINKLER ZONES TO MATCH LIFE SAFETY ZONING. MATCH EXISTING
SPRINKLERS.
P19 PROVIDE 3/8" DCW W/ANGLE STOP SHUT-OFF VALVE AND 72" OF 3/8"
SOFT COPPER TUBING FROM BELOW COUNTER SINK DCW SUPPLY.
CONNECT TO ICE MAKER, COFFEE MAKER, AND WATER FILLER ABOVE
COUNTER TOP.
P20 DEMO EXISTING STUDOR VENT SERVING BREAK ROOM SINK.
PROVIDE NEW 1-1/2"V FOR EXISTING BREAK ROOM SINK.
P21 RELOCATE EXISTING SINK AND FAUCET TO NEW LOCATION IN
NUCLEAR MEDICINE CAMERA ROOM. DEMO DCW DHW VENT AND
WASTE BACK TO MAINS WHERE EXISTING SINK IS BEING REMOVED
FROM EXISTING LOCATION. PROVIDE NEW CONNECTIONS AT NEW
LOCATION AS DESCRIBED FOR FIXTURE S-12. LEAVE NO DEADLEGS.
P23 REPLACE EXISTING CORRODED WRIST-BLADE FAUCET HANDLES FOR
INDICATED SINKS. EXISTING FAUCETS ARE 2 CORE T&S BRASS ON 4"
CENTERS.
Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC PIPING,
AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA.
SCALE: 1/8" = 1'-0"
LEVEL 1 DOMESTIC WATER PLAN - CENTRAL
SCALE: 1/8" = 1'-0"
LEVEL 1 DOMESTIC WATER PLAN - PHARMACY
SCALE: 1/8" = 1'-0"
LEVEL 2 DOMESTIC WATER PLAN - CENTRAL
06/30/17