Loading...
HomeMy WebLinkAboutB17-0092_P-121-1_1508947716.pdf~~~~~~~~~~~ CAP TYP. W W SD W W/CO 2 1/2" 3/4" WH 1" 2" 1 1/4" 3/4" 2" 1" 2 1/2" 3/4" 3/4" 1 1/4" 2" 1 1/2" 3/4" 1" 2" 1 1/4" 1"1 1/2"2" 1/2" S-1 S-2 SH-1 1" 2 1/2" 3/4" " 1/2" 3/4" 1/2" 3/4" 1/2" 3/4" 2" 1" 1 1/2" 2 1/2" 1" 1 1/4" 2 1/2" 2" 1 1/2" /2" 2" 1/2" 1 1/4" 1/2" 1/2" S-2 S-1 1" CW UP TO HUMIDIFIER CAPPED EWC-1 RECONNECT CW TO NEW EWC DN 1/2"CW DN TO WATER DISPENSER (BY OTHERS) s" s" i" 1r" i" 3/4" 3/4" 1/2" 2"1/2" 1 1/4" 1/2" 1 1/2"1/2"CW/HW DN 1 1/4" 1" 1 1 1/2" 3/4" 2 1/2" HW 2" HWC 4" CW 2 1/2" HW 2" HWC 4" CW P15 WC-1 L-1 L-1 L-1 WC-1 MSB-2 BALANCE TO 0.5 GPM CONNECT TO (E) RECIRC CONNECT TO REPLACED RECIRC. REF: KEYNOTE P16 S-14 W/EW Q4 P16 P18 P18 1" CW 1" HW 3/4" CW 3/4" HWC P21 BALANCE TO 0.5 GPM BALANCE TO 0.5 GPM 1" CW 1" HW P24 P154" CW 2" HWC 2 1/2" HW 1 S-1 P26 S-14 W/EW S-12 DEMO FIXTURE, PIPING AND ANY DEAD LEGS BALANCE TO 0.5 GPM P18 (E) SINK (E) SINK (E) SINK (E) SINK WC-1L-1 S-1 S-1 1" CW 1" CW 1/2" CW BALANCE TO 0.5 GPM P23 P23 P20 S-1 P23 P23 P18 P18 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/10/2017 2:01:08 PM15924.00 P-121.1 LEVEL 1 AND 2 DOMESTIC WATER PLANS - CENTRAL 07/11/17PERMIT RESUBMISSION EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 81657A B C KEYNOTES P15 4" DOMESTIC WATER INTERCONNECTION BETWEEN WEST WING AND EAST WING, 2-1/2" HOT WATER, AND 2" HOT WATER RECIRC. REPLACE PIPING AS PART OF THE CENTRAL WING ENABLING WORK. PROVIDE VALVE AND CAP FOR FUTURE CONNECTION OF EAST WING PIPING. P16 REPLACE ALL EXISTING DOMESTIC WATER RECIRC PIPING WITHIN THIS SCOPE AREA. EXISTING PIPING HAS MULTIPLE PINHOLE LEAKS. P18 WITHIN BOUNDS OF RENOVATION SCOPE AREA, MODIFY THE EXISTING WET FIRE PROTECTION SYSTEM AS REQUIRED IN ACCORDANCE WITH NFPA-13 AND THE LOCAL AHJ REQUIREMENTS TO ACCOMODATE THE ARCHITECTURAL REMODEL. MODIFY EXISTING SPRINKLER ZONES TO MATCH LIFE SAFETY ZONING. MATCH EXISTING SPRINKLERS. P20 DEMO EXISTING STUDOR VENT SERVING BREAK ROOM SINK. PROVIDE NEW 1-1/2"V FOR EXISTING BREAK ROOM SINK. P21 RELOCATE EXISTING SINK AND FAUCET TO NEW LOCATION IN NUCLEAR MEDICINE CAMERA ROOM. DEMO DCW DHW VENT AND WASTE BACK TO MAINS WHERE EXISTING SINK IS BEING REMOVED FROM EXISTING LOCATION. PROVIDE NEW CONNECTIONS AT NEW LOCATION AS DESCRIBED FOR FIXTURE S-12. LEAVE NO DEADLEGS. P23 REPLACE EXISTING CORRODED WRIST-BLADE FAUCET HANDLES FOR INDICATED SINKS. EXISTING FAUCETS ARE 2 CORE T&S BRASS ON 4" CENTERS. P24 PROVIDE 1" DCW TO HUMIDIFIER RELOCATED FROM OWNER STORAGE AND CONNECT TO HUMIDIFIER AS INSTRUCTED IN HUMIDIFIER INSTALLATION DOCUMENTATION, WITH WATER SEAL/LOOP. HUMIDIFIER HAS INTEGRAL AIR GAP TO PREVENT DCW CONTAMINATION. P26 IN AREA INDICATED BY CROSSHATCH, MODIFY EXISTING SPRINKLER SYSTEM MAIN LOCATION. MAIN IS CURRENTLY INSTALLED NEAR CEILING GRID. RELOCATED THIS MAIN AS HIGH AGAINST STRUCTURE AS POSSIBLE TO AID IN COORDINATION WITH OTHER SYSTEMS. Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC PIPING, AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA. SCALE: 1/8" = 1'-0" LEVEL 1 DOMESTIC WATER PLAN - CENTRAL SCALE: 1/8" = 1'-0" LEVEL 1 DOMESTIC WATER PLAN - PHARMACY SCALE: 1/8" = 1'-0" LEVEL 2 DOMESTIC WATER PLAN - CENTRAL ADDENDUM 1 05/23/2017 1 10/25/17