HomeMy WebLinkAboutB17-0092_P-121-1_1508947716.pdf~~~~~~~~~~~
CAP TYP.
W
W SD W W/CO
2 1/2"
3/4"
WH
1"
2"
1 1/4"
3/4"
2"
1"
2 1/2"
3/4"
3/4" 1 1/4"
2"
1 1/2"
3/4"
1"
2"
1 1/4"
1"1 1/2"2"
1/2"
S-1
S-2
SH-1
1"
2 1/2"
3/4"
" 1/2" 3/4"
1/2"
3/4"
1/2"
3/4"
2"
1"
1 1/2"
2 1/2"
1"
1 1/4"
2 1/2"
2"
1 1/2"
/2"
2"
1/2"
1 1/4"
1/2"
1/2"
S-2
S-1
1" CW UP TO
HUMIDIFIER
CAPPED
EWC-1
RECONNECT CW
TO NEW EWC
DN
1/2"CW DN TO WATER
DISPENSER (BY OTHERS)
s"
s"
i"
1r"
i"
3/4"
3/4"
1/2"
2"1/2"
1 1/4"
1/2"
1 1/2"1/2"CW/HW DN
1 1/4"
1"
1
1
1/2"
3/4"
2 1/2" HW
2" HWC
4" CW
2 1/2" HW
2" HWC
4" CW
P15
WC-1
L-1
L-1
L-1 WC-1
MSB-2
BALANCE
TO 0.5 GPM
CONNECT TO
(E) RECIRC
CONNECT TO REPLACED
RECIRC. REF: KEYNOTE P16
S-14
W/EW
Q4
P16
P18
P18
1" CW
1" HW
3/4" CW
3/4" HWC
P21
BALANCE
TO 0.5 GPM
BALANCE
TO 0.5 GPM
1" CW
1" HW
P24
P154" CW
2" HWC 2 1/2" HW
1
S-1
P26 S-14
W/EW
S-12
DEMO
FIXTURE,
PIPING AND
ANY DEAD
LEGS
BALANCE
TO 0.5
GPM
P18
(E) SINK
(E) SINK
(E) SINK
(E) SINK
WC-1L-1
S-1
S-1
1" CW
1" CW
1/2" CW
BALANCE
TO 0.5 GPM
P23
P23
P20 S-1
P23
P23
P18
P18
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP,
P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL WING RENOVATION
7/10/2017 2:01:08 PM15924.00
P-121.1
LEVEL 1 AND 2 DOMESTIC
WATER PLANS - CENTRAL
07/11/17PERMIT
RESUBMISSION
EAST WING
ADDITION
180 S Frontage Rd W, Vail, CO 81657A
B
C
KEYNOTES
P15 4" DOMESTIC WATER INTERCONNECTION BETWEEN WEST WING AND
EAST WING, 2-1/2" HOT WATER, AND 2" HOT WATER RECIRC.
REPLACE PIPING AS PART OF THE CENTRAL WING ENABLING WORK.
PROVIDE VALVE AND CAP FOR FUTURE CONNECTION OF EAST WING
PIPING.
P16 REPLACE ALL EXISTING DOMESTIC WATER RECIRC PIPING WITHIN
THIS SCOPE AREA. EXISTING PIPING HAS MULTIPLE PINHOLE LEAKS.
P18 WITHIN BOUNDS OF RENOVATION SCOPE AREA, MODIFY THE
EXISTING WET FIRE PROTECTION SYSTEM AS REQUIRED IN
ACCORDANCE WITH NFPA-13 AND THE LOCAL AHJ REQUIREMENTS
TO ACCOMODATE THE ARCHITECTURAL REMODEL. MODIFY
EXISTING SPRINKLER ZONES TO MATCH LIFE SAFETY ZONING.
MATCH EXISTING SPRINKLERS.
P20 DEMO EXISTING STUDOR VENT SERVING BREAK ROOM SINK.
PROVIDE NEW 1-1/2"V FOR EXISTING BREAK ROOM SINK.
P21 RELOCATE EXISTING SINK AND FAUCET TO NEW LOCATION IN
NUCLEAR MEDICINE CAMERA ROOM. DEMO DCW DHW VENT AND
WASTE BACK TO MAINS WHERE EXISTING SINK IS BEING REMOVED
FROM EXISTING LOCATION. PROVIDE NEW CONNECTIONS AT NEW
LOCATION AS DESCRIBED FOR FIXTURE S-12. LEAVE NO DEADLEGS.
P23 REPLACE EXISTING CORRODED WRIST-BLADE FAUCET HANDLES
FOR INDICATED SINKS. EXISTING FAUCETS ARE 2 CORE T&S BRASS
ON 4" CENTERS.
P24 PROVIDE 1" DCW TO HUMIDIFIER RELOCATED FROM OWNER
STORAGE AND CONNECT TO HUMIDIFIER AS INSTRUCTED IN
HUMIDIFIER INSTALLATION DOCUMENTATION, WITH WATER
SEAL/LOOP. HUMIDIFIER HAS INTEGRAL AIR GAP TO PREVENT DCW
CONTAMINATION.
P26 IN AREA INDICATED BY CROSSHATCH, MODIFY EXISTING SPRINKLER
SYSTEM MAIN LOCATION. MAIN IS CURRENTLY INSTALLED NEAR
CEILING GRID. RELOCATED THIS MAIN AS HIGH AGAINST
STRUCTURE AS POSSIBLE TO AID IN COORDINATION WITH OTHER
SYSTEMS.
Q4 PATCH ANY EXISTING INSULATION ON DUCTWORK, HYDRONIC
PIPING, AND DOMESTIC WATER PIPING WITHIN THIS SCOPE AREA.
SCALE: 1/8" = 1'-0"
LEVEL 1 DOMESTIC WATER PLAN - CENTRAL
SCALE: 1/8" = 1'-0"
LEVEL 1 DOMESTIC WATER PLAN - PHARMACY
SCALE: 1/8" = 1'-0"
LEVEL 2 DOMESTIC WATER PLAN - CENTRAL
ADDENDUM 1 05/23/2017 1
10/25/17