HomeMy WebLinkAboutB17-0092_STRUCT ENGINEERING CALC_1491500700.pdf
Vail Valley Medical Center
Central Wing Renovation
Martin/Martin, Inc. Project No.: 16.0188.S.01
Structural Calculations
March 2, 2017
March 10, 2017
Index of Structural Calculations
1. Design Parameters 1-3
2. Framing Calculations 4-8
Martin/Martin, Inc.JOB TITLE VVMC - EAST WING ADD & RENO
12499 W Colfax Ave.
Lakewood, CO 80215 JOB NO.16.0188.S.01 SHEET NO.
(303) 431-6100 (phone)CALCULATED BY MDS DATE 5/16/16
(303) 431-6866 (fax)CHECKED BY DATE
www.struware.com
Code Search
Code:International Building Code 2015
Occupancy:
Occupancy Group =I Institutional
Risk Category & Importance Factors:
Risk Category = IV
Wind factor = 1.00
Snow factor = 1.20
Seismic factor = 1.50
Type of Construction:
Fire Rating:
Roof = 0.0 hr
Floor = 0.0 hr
Building Geometry:
Roof angle (θ) 0.25 / 12 1.2 deg
Building length (L) 120.0 ft
Least width (B) 302.0 ft
Mean Roof Ht (h) 80.0 ft
Parapet ht above grd 86.0 ft
Minimum parapet ht 6.0 ft
Live Loads:
Roof 0 to 200 sf: 20 psf
200 to 600 sf: 24 - 0.02Area, but not less than 12 psf
over 600 sf: 12 psf
Floor:
0 psf
N/A
See Attached for Live Loads 0 psf
See Attached for Live Loads 0 psf
See Attached for Live Loads 0 psf
See Attached for Live Loads 0 psf
See Attached for Live Loads 0 psf
See Attached for Live Loads 0 psf