Loading...
HomeMy WebLinkAboutB17-0092_T-001.1_1498849140.pdfREFERENCE SYMBOLS LEGEND (Not all symbols listed below are used on these drawings) KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE MECHANICAL EQUIPMENT REFERENCE EXISTING TO REMAIN EXISTING TO BE REMOVED EXISTING TO BE RELOCATED EXISTING TO REMAIN - REPLACE DEVICE DESCRIPTION DESCRIPTION SYMBOL 1 1 UH E R RL ER TECHNOLOGY LEGEND (Not all symbols listed below are used on these drawings) TELEPHONE TERMINAL CABINET TELEPHONE TERMINAL BACKBOARD ELECTRIC HINGE ELECTRIC POWER TRANSFER ELECTRIC DOOR LOCK ELECTRIC DOOR STRIKE TELE/DATA OUTLET, FLOOR MOUNTED (#=QTY OF CABLES) SECURITY CONTROL PANEL POWER SUPPLY MOTION DETECTOR (WALL MOUNTED) MAGNETIC DOOR LOCK GLASS BREAK DETECTOR (CEILING MOUNTED) GLASS BREAK DETECTOR (WALL MOUNTED) TELEPHONE/POWER POLE INTERCOM STATION KEYPAD MICROPHONE STATION DESCRIPTION SYMBOL DESCRIPTION SYMBOL SYMBOL CR CARD READER (IL = INTEGRATED LOCK) DOOR CONTACT EH EP EL ES GB IC KP M ML MD PS SEC VC WAP GB VOLUMN CONTROL WIRELESS ACCESS POINT TELEVISION OUTLET CLOCK OUTLET (D= DOUBLE SIDED) PUSH BUTTON PAGING SYSTEM SPEAKER PAGING SYSTEM HORN (HIGH OUTPUT) BOX SPEAKER - SURFACE MOUNT SECURITY CAMERA PROJECTOR TP D S S C S TELE/DATA OUTLET (#=QTY OF CABLES) FLAG NOTE REFERENCE W TELEPHONE, WALL MOUNTED REQUEST TO EXIT RX DURESS ALARM DA MOTION DETECTOR (CEILING MOUNTED) MD DAS DONNER ANTENNA NURSE CALL LEGEND (Not all symbols listed below are used on these drawings) DOME LIGHT, WALL MOUNTED DOME LIGHT, CEILING MOUNTED DUTY STATION REMOTE LOCATOR RECEIVER SINGLE PATIENT STATION (A = W/AUDIO STATION) DESCRIPTION SYMBOL DESCRIPTION SYMBOL CODE CALL STATION (CODE BLUE) CONSOLIDATED ROOM BORAD WITH RELAYS MASTER STATION NURSE CALL STATION ZONE DOME LIGHT, CEILING MOUNTED EMERGENCY PULL CORD, BATH/TOILET (PB = CORD WITH PUSHBUTTON) Z MS NC CB RB EP D RL SP ALARM INTERFACE UNIT AI BED INTERFACE UNIT BI NURSE CALL HEAD END/CONTROL PANEL NC ZONE DOME LIGHT, WALL MOUNTED Z A STAFF EMERGENCY STATION SS ABBREVIATIONS LEGEND ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE RAISED FLOOR BELOW FINISHED GRADE MINIMUM NORMALLY CLOSED NORMALLY OPEN NOT TO SCALE CONDUIT CABLE TELEVISION CLOSED CIRCUIT TELEVISION EXISTING EMERGENCY EXPLOSION PROOF FIRE ALARM GROUND LOCK DOWN WEATHER PROOF WITHOUT WITH UNINTERRUPTABLE POWER SUPPLY UNLESS OTHERWISE NOTED UNDER GROUND UNDER FLOOR TYPICAL TRANSIENT VOLTAGE SURGE SUPPRESSER TAMPER PROOF STAND-BY PULL BOX ON SITE WORK FORCE OWNER FURNISHED, OWNER INSTALLED OWNER FURNISHED, CONTRACTOR INSTALLED ON CENTER ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH NOT IN CONTRACT DESCRIPTION SYMBOL DESCRIPTION SYMBOL (Not all symbols listed below are used on these drawings) LD G FA EP EM (E) CCTV CATV C BFG ARF AFG AFF AC WP W/O W/ UPS UON UG UF TYP TVSS TP SB PB OSWF OFOI OFCI OC NTS NO NIC NC MIN MAXIMUM MAX TIME CLOCK TC PIEZO/SOUNDER PZ ELECTRIC WHITE BOARD EWB BIO-HAZARD BIO ELAPSE TIME CLOCK ETC WIREMOLD WM # # CODE BLUE/STAFF ASSIST STATION CB SA TELE/DATA OUTLET, CEILING MOUNTED (# = QTY OF CABLES) # IL GENERAL NOTES: WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 1. 2. 3. 4. 5. 6. 7. DEMOLITION NOTES: UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES, ETC. TO BE REMOVED. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS. REWORK EXISTING TERMINATIONS, CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT CONTINUITY TO EXISTING CIRCUITS AND DEVICES TO REMAIN OR BE RELOCATED. PRIOR TO COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT SUPPORTS BACK TO POINT OF ORIGIN OR NEXT DEVICE TO REMAIN. REMOVED ITEMS SHALL BE TURNED OVER TO THE OWNER, UNLESS NOTED OTHERWISE, AND STORED IN THE AREA DESIGNATED BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER CHOOSES NOT TO ACCEPT. WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. REUSE EXISTING CONDUIT WHERE CURRENT NEC AND LOCAL CODE REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR NEW INSTALLATIONS AND EXTENSION OF EXISTING INSTALLATIONS. REUSE EXISTING CONDUIT IN PLACE, DO NOT REINSTALL EXISTING CONDUIT. PROVIDE LABELING PER SPECIFICATIONS FOR REUSED CONDUIT. RELOCATED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL FOREIGN MATERIAL. REPLACE EQUIPMENT OR DEVICES WHICH ARE DEFECTIVE OR DAMAGED DURING RELOCATION. PROVIDE A BLANK PLATE AT ANY EXISTING BACK BOX NOT RE-USED AFTER REMOVING CABLES. 1. 2. 3. 4. 5. 6. 7. TECHNOLOGY PLAN NOTES: PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL TELE/DATA OUTLETS. ROUTE 1" CONDUIT FROM EACH OUTLET TO ABOVE ACCESSIBLE CEILING UNLESS NOTED OTHERWISE. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. KEEP ALL EXPOSED CONDUITS TIGHT TO STRUCTURE. PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL SECURITY, CCTV,ACCESS CONTROL, WAP, AND TELEVISION OUTLETS. ROUTE 3/4" CONDUIT FROM EACH OUTLET TO ABOVE ACCESSIBLE CEILING UNLESS NOTED OTHERWISE. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. KEEP ALL EXPOSED CONDUITS TIGHT TO STRUCTURE. PROVIDE AN 8' SERVICE LOOP AT STATION END OF ALL CABLE RUNS. PROVIDE 25' SERVICE LOOP AT ALL WIRELESS ACCESS POINT LOCATIONS. TERMINATE CABLE ON A SURFACE MOUNT OULTLET BOX. PROVIDE OBERON WAP ENCLOSURE. HOMERUN ALL VOICE, DATA, TELEVISION, ACCESS CONTROL, SECURITY, CLOCKS, SPEAKERS, AND CCTV CABLES TO DESIGNATED CONTROL PANELS, PATCH PANELS, OR WALL FIELDS IN EXISTING TELECOMMUNICATION ROOM 1048. PROVIDE J-HOOK TYPE CABLE SUPPORTS IN OPEN OR ACCESSIBLE CEILING SPACE AS REQUIRED TO SUPPORT CABLES IN ROUTE TO CABLE TRAY OR CONDUIT PATHWAY TO TELECOMMUNICATIONS ROOM. ROUTE CABLE SUPPORTS SUCH THAT CABLE VISIBILITY WILL BE MINIMIZED IN ANY OPEN CEILING AREAS. COORDINATE NURSE CALL BACK BOX REQUIREMENTS WITH NURSE CALL VENDOR. PROVIDE CAT 6 CABLE AT CLOCK LOCATIONS. PROVIDE NEW CAT 6 CABLE AT RELOCATED ACCESS POINT LOCATIONS. PROVIDE BLAMK PLATES FOR OUTLET BOXES TO REMAIN. COORDINATE CARD READER LOCATION AND MOUNTING WITH OWNER AND ARCHITECT. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL, CEILING, AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH-IN. ALL EXISTING SPEAKERS TO REMAIN MUST WIRE BACK TO TELECOM ROOM 1048. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY ENGINEER OF ADVERSE FIELD CONDITIONS PRIOR TO PERFORMING ANY WORK. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. TOP OF CABINET 84" (7'-0") UON 96" (8'-0") UON 72" (6'-0") UON 54" (4'-6") UON 48" (4'-0") UON TYPICAL 9'-0" CEILING OR HIGHER TYPICAL 8'-0" CEILING 2. 3. NOTES: 1. FINISHED FLOOR 18" (1'-6") UON NOTE: ALL DEVICES INDICATED TO BE INSTALLED AT DIFFERENT MOUNTING HEIGHTS AND LOCATED WITHIN ONE STUD SPACE FROM EACH OTHER SHALL ALIGN VERTICALLY, ON THE SAME SIDE OF THE STUD. WHERE WALL MOUNTED TELEPHONES OCCUR OVER LIGHT SWITCHES, VOLUME CONTROLS, ETC. OFFSET ONE STUD SPACE. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. W CONTROL PANELS TOP S TOP S C C B B MD MD C C CR VC IC NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS KP M CB EP D SP SS 44" (3'-8") UON TOILET COUNTER TOP MS DA GB GB S 80" (6'-8") UON PROVIDE 10" SLEEVE OVER THREADED ROD FOR CABLE PROTECTION TRAPEZE TYPE CABLE TRAY. SUPPORT ACROSS BOTTOM SIDE OF TRAY EVERY 8' MAXIMUM. THREADED ROD DOUBLE NUT OR NYLOCK NOTE: PROVIDE #10 COPPER GROUND CONDUCTOR IN WIRE BASKET. ATTACH WITHIN 6" OF BASKET SECTIONS USING SPLIT BOLTS. TERMINATE GROUND ON TELECOM GROUND BAR. WIRE BASKET DETAIL NO SCALE ALL WIRES AND CABLES SHALL BE SUPPORTED. MAXIMUM SPACING BETWEEN HOOKS SHALL BE 4' to 5'. ATTACH HOOK ASSEMBLY TO BUILDING STRUCTURE. ALL CABLE RUNS TO BE PERPENDICULAR AND PARALLEL TO BUILDING WALLS. NOTE: 2" 4'-5' TO NEXT ASSEMBLY (TYP.) ATTACHED TO STURCTURE AS REQUIRED 3/8" ROD LENGTH AS REQUIRED COMMUNICATION CABLE J-HOOK. QUANTITIES AS REQUIRED. CABLE SUPPORT SYSTEM DETAIL NO SCALE TO ACCESS CONTROL PANEL 3/4" C. STUB FLOOR LINE SECURE AREA 3" 1/2" CONDUIT (STUBBED BEHIND DRYWALL REFER TO NOTE 3) FLUSH MOUNT DOOR CONTACT SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). NOTES: MOUNT SJB AT 10' CENTER AFF CEILING 2. 1. 4. 3. SINGLE DOOR NO SCALE ELECTRIC STRIKE 1/2" C. 48" AFF CL CARD READER 4"X4" BOX W/SINGLE GANG MUD RING. REFER TO FLOOR PLAN FOR LOCATION. 1/2" C. REQUEST TO EXIT DEVICE MOUNT CENTERED ON DOORS APPROXIMATLEY 12" ABOVE DOOR FRAME 1/2" C. (STUBBED BEHIND DRYWALL) HINGE SIDE TO ACCESS CONTROL PANEL 3/4" C. STUB FLOOR LINE SECURE AREA SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). NOTES: MOUNT SJB AT 10' CENTER AFF CEILING 2. 1. 4. 3. SINGLE DOOR NO SCALE 1/2" C. 1/2" C. POWER SUPPLY 48" AFF TYP. CL PUSH PAD (TYP). REFER TO FLOOR PLAN FOR LOCATION. AUTO OP. HINGE SIDE 1/2" C. (STUBBED BEHIND DRYWALL) 3/4" C. STUB TO ACCESS CONTROL PANEL FLUSH MOUNT DOOR CONTACT (TYP.) CEILING MOUNT SJB AT 10' CENTER AFF SECURE AREA FLOOR LINE 6" 3" NOTES: SECURITY JUNCTION BOX (SJB) SHALL BE 6X6X6 WITH SCREW COVER. ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). DOUBLE DOOR NO SCALE 3. 4. 1. 2. CL 1/2" C. CARD READER 4"X4" J-BOXES W/SINGLE GANG MUD RING. REFER TO FLOOR PLAN FOR LOCATIONS 48" AFF 1/2" C. (STUBBED BEHIND DRYWALL) ELECTRIC HINGE HINGE SIDE HINGE SIDE REQUEST TO EXIT DEVICE MOUNT CENTERED ON DOORS APPROXIMATLEY 12" ABOVE DOOR FRAME 1/2" C. (STUBBED BEHIND DRYWALL) TO ACCESS CONTROL PANEL 3/4" C. STUB FLOOR LINE SECURE AREA 3" 1/2" CONDUIT (STUBBED BEHIND DRYWALL REFER TO NOTE 3) FLUSH MOUNT DOOR CONTACTS SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). NOTES: MOUNT SJB AT 10' CENTER AFF CEILING 2. 1. 4. 3. SINGLE DOOR NO SCALE 48" AFF CL CARD READER 4"X4" BOX W/SINGLE GANG MUD RING. REFER TO FLOOR PLAN FOR LOCATION. 1/2" C. ELECTRIC POWER TRANSFER 1/2" C. (STUBBED BEHIND DOOR FRAME) REQUEST TO EXIT DEVICE MOUNT CENTERED ON DOORS APPROXIMATLEY 12" ABOVE DOOR FRAME 1/2" C. (STUBBED BEHIND DRYWALL) 3" HINGE SIDE HINGE SIDE TO ACCESS CONTROL PANEL 3/4" C. STUB FLOOR LINE SECURE AREA SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). NOTES: MOUNT SJB AT 10' CENTER AFF CEILING 2. 1. 3. SINGLE DOOR NO SCALE INTEGRATED CARD READER 1/2" C. HINGE SIDE ELECTRIC HINGE 1/2" C. 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 3/10/2017 10:59:15 AM 15924.00 T-001.1 TECHNOLOGY LEGENDS & NOTES 2017 03/10/17 PERMIT VAIL VALLEY MEDICAL CENTER 180 S. Frontage Road West, Vail, CO 81657 06/30/17