HomeMy WebLinkAboutB17-0092_T-001.1_1498849140.pdfREFERENCE SYMBOLS LEGEND
(Not all symbols listed below are used on these drawings)
KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE
MECHANICAL EQUIPMENT REFERENCE
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING TO BE RELOCATED
EXISTING TO REMAIN - REPLACE DEVICE
DESCRIPTION DESCRIPTION
SYMBOL
1
1
UH
E
R
RL
ER
TECHNOLOGY LEGEND
(Not all symbols listed below are used on these drawings)
TELEPHONE TERMINAL CABINET
TELEPHONE TERMINAL BACKBOARD
ELECTRIC HINGE
ELECTRIC POWER TRANSFER
ELECTRIC DOOR LOCK
ELECTRIC DOOR STRIKE
TELE/DATA OUTLET, FLOOR MOUNTED (#=QTY OF CABLES)
SECURITY CONTROL PANEL
POWER SUPPLY
MOTION DETECTOR (WALL MOUNTED)
MAGNETIC DOOR LOCK
GLASS BREAK DETECTOR (CEILING MOUNTED)
GLASS BREAK DETECTOR (WALL MOUNTED)
TELEPHONE/POWER POLE
INTERCOM STATION
KEYPAD
MICROPHONE STATION
DESCRIPTION
SYMBOL
DESCRIPTION
SYMBOL
SYMBOL
CR CARD READER (IL = INTEGRATED LOCK)
DOOR CONTACT
EH
EP
EL
ES
GB
IC
KP
M
ML
MD
PS
SEC
VC
WAP
GB
VOLUMN CONTROL
WIRELESS ACCESS POINT
TELEVISION OUTLET
CLOCK OUTLET (D= DOUBLE SIDED)
PUSH BUTTON
PAGING SYSTEM SPEAKER
PAGING SYSTEM HORN (HIGH OUTPUT)
BOX SPEAKER - SURFACE MOUNT
SECURITY CAMERA
PROJECTOR
TP
D
S
S
C
S
TELE/DATA OUTLET (#=QTY OF CABLES)
FLAG NOTE REFERENCE
W TELEPHONE, WALL MOUNTED
REQUEST TO EXIT
RX
DURESS ALARM
DA
MOTION DETECTOR (CEILING MOUNTED)
MD
DAS DONNER ANTENNA
NURSE CALL LEGEND
(Not all symbols listed below are used on these drawings)
DOME LIGHT, WALL MOUNTED
DOME LIGHT, CEILING MOUNTED
DUTY STATION
REMOTE LOCATOR RECEIVER
SINGLE PATIENT STATION (A = W/AUDIO STATION)
DESCRIPTION SYMBOL
DESCRIPTION
SYMBOL
CODE CALL STATION (CODE BLUE)
CONSOLIDATED ROOM BORAD WITH RELAYS
MASTER STATION
NURSE CALL STATION
ZONE DOME LIGHT, CEILING MOUNTED
EMERGENCY PULL CORD, BATH/TOILET (PB = CORD WITH
PUSHBUTTON)
Z
MS
NC
CB
RB
EP
D
RL
SP
ALARM INTERFACE UNIT
AI
BED INTERFACE UNIT
BI
NURSE CALL HEAD END/CONTROL PANEL
NC
ZONE DOME LIGHT, WALL MOUNTED
Z
A
STAFF EMERGENCY STATION
SS
ABBREVIATIONS LEGEND
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE RAISED FLOOR
BELOW FINISHED GRADE
MINIMUM
NORMALLY CLOSED
NORMALLY OPEN
NOT TO SCALE
CONDUIT
CABLE TELEVISION
CLOSED CIRCUIT TELEVISION
EXISTING
EMERGENCY
EXPLOSION PROOF
FIRE ALARM
GROUND
LOCK DOWN
WEATHER PROOF
WITHOUT
WITH
UNINTERRUPTABLE POWER SUPPLY
UNLESS OTHERWISE NOTED
UNDER GROUND
UNDER FLOOR
TYPICAL
TRANSIENT VOLTAGE SURGE SUPPRESSER
TAMPER PROOF
STAND-BY
PULL BOX
ON SITE WORK FORCE
OWNER FURNISHED, OWNER INSTALLED
OWNER FURNISHED, CONTRACTOR INSTALLED
ON CENTER
ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE
OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH
NOT IN CONTRACT
DESCRIPTION SYMBOL
DESCRIPTION
SYMBOL
(Not all symbols listed below are used on these drawings)
LD
G
FA
EP
EM
(E)
CCTV
CATV
C
BFG
ARF
AFG
AFF
AC
WP
W/O
W/
UPS
UON
UG
UF
TYP
TVSS
TP
SB
PB
OSWF
OFOI
OFCI
OC
NTS
NO
NIC
NC
MIN
MAXIMUM
MAX
TIME CLOCK
TC
PIEZO/SOUNDER
PZ
ELECTRIC WHITE BOARD
EWB
BIO-HAZARD
BIO
ELAPSE TIME CLOCK
ETC
WIREMOLD
WM
#
#
CODE BLUE/STAFF ASSIST STATION
CB SA
TELE/DATA OUTLET, CEILING MOUNTED (# = QTY OF CABLES)
#
IL
GENERAL NOTES:
WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS
TO REMAIN ARE DENOTED LIGHTLY.
PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY
REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE
CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR
NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED
OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO
OWNER PRIOR TO BEGINNING WORK.
INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED.
PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE
SURROUNDING AREA.
DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS
UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED
FROM THE STRUCTURAL ENGINEER.
FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO
ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS.
A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A
CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS,
TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM
WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING
MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM
OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR,
RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY
INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT
PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS.
1.
2.
3.
4.
5.
6.
7.
DEMOLITION NOTES:
UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES, ETC. TO
BE REMOVED.
DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED.
CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE EXACT
EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT
DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE ALLOWED FOR WORK
REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT
DOCUMENTS. REWORK EXISTING TERMINATIONS, CONNECTIONS, CONDUIT,
WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT CONTINUITY TO EXISTING
CIRCUITS AND DEVICES TO REMAIN OR BE RELOCATED. PRIOR TO
COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS AND
NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION.
ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY
INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT SUPPORTS BACK TO
POINT OF ORIGIN OR NEXT DEVICE TO REMAIN. REMOVED ITEMS SHALL BE
TURNED OVER TO THE OWNER, UNLESS NOTED OTHERWISE, AND STORED IN THE
AREA DESIGNATED BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE
OF ALL ITEMS THE OWNER CHOOSES NOT TO ACCEPT.
WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN
ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE CEILINGS,
THEY SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH GROUT TO ACHIEVE
A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER
CONDUCTORS HAVE BEEN REMOVED.
REUSE EXISTING CONDUIT WHERE CURRENT NEC AND LOCAL CODE
REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR NEW
INSTALLATIONS AND EXTENSION OF EXISTING INSTALLATIONS. REUSE EXISTING
CONDUIT IN PLACE, DO NOT REINSTALL EXISTING CONDUIT. PROVIDE LABELING
PER SPECIFICATIONS FOR REUSED CONDUIT.
RELOCATED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL FOREIGN
MATERIAL. REPLACE EQUIPMENT OR DEVICES WHICH ARE DEFECTIVE OR
DAMAGED DURING RELOCATION.
PROVIDE A BLANK PLATE AT ANY EXISTING BACK BOX NOT RE-USED AFTER
REMOVING CABLES.
1.
2.
3.
4.
5.
6.
7.
TECHNOLOGY PLAN NOTES:
PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL
TELE/DATA OUTLETS. ROUTE 1" CONDUIT FROM EACH OUTLET TO ABOVE
ACCESSIBLE CEILING UNLESS NOTED OTHERWISE. PROVIDE INSULATED THROAT
CONNECTOR ON CONDUIT END. KEEP ALL EXPOSED CONDUITS TIGHT TO
STRUCTURE.
PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL
SECURITY, CCTV,ACCESS CONTROL, WAP, AND TELEVISION OUTLETS. ROUTE
3/4" CONDUIT FROM EACH OUTLET TO ABOVE ACCESSIBLE CEILING UNLESS
NOTED OTHERWISE. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT
END. KEEP ALL EXPOSED CONDUITS TIGHT TO STRUCTURE.
PROVIDE AN 8' SERVICE LOOP AT STATION END OF ALL CABLE RUNS. PROVIDE
25' SERVICE LOOP AT ALL WIRELESS ACCESS POINT LOCATIONS. TERMINATE
CABLE ON A SURFACE MOUNT OULTLET BOX. PROVIDE OBERON WAP
ENCLOSURE.
HOMERUN ALL VOICE, DATA, TELEVISION, ACCESS CONTROL, SECURITY, CLOCKS,
SPEAKERS, AND CCTV CABLES TO DESIGNATED CONTROL PANELS, PATCH
PANELS, OR WALL FIELDS IN EXISTING TELECOMMUNICATION ROOM 1048.
PROVIDE J-HOOK TYPE CABLE SUPPORTS IN OPEN OR ACCESSIBLE CEILING
SPACE AS REQUIRED TO SUPPORT CABLES IN ROUTE TO CABLE TRAY OR
CONDUIT PATHWAY TO TELECOMMUNICATIONS ROOM. ROUTE CABLE SUPPORTS
SUCH THAT CABLE VISIBILITY WILL BE MINIMIZED IN ANY OPEN CEILING AREAS.
COORDINATE NURSE CALL BACK BOX REQUIREMENTS WITH NURSE CALL
VENDOR.
PROVIDE CAT 6 CABLE AT CLOCK LOCATIONS.
PROVIDE NEW CAT 6 CABLE AT RELOCATED ACCESS POINT LOCATIONS.
PROVIDE BLAMK PLATES FOR OUTLET BOXES TO REMAIN.
COORDINATE CARD READER LOCATION AND MOUNTING WITH OWNER AND
ARCHITECT.
COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL, CEILING, AND
FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR
SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH-IN.
ALL EXISTING SPEAKERS TO REMAIN MUST WIRE BACK TO TELECOM ROOM 1048.
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY ENGINEER
OF ADVERSE FIELD CONDITIONS PRIOR TO PERFORMING ANY WORK.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
TOP OF CABINET
84" (7'-0")
UON
96" (8'-0")
UON
72" (6'-0")
UON
54" (4'-6")
UON
48" (4'-0")
UON
TYPICAL 9'-0" CEILING OR HIGHER
TYPICAL 8'-0" CEILING
2.
3.
NOTES:
1.
FINISHED FLOOR
18" (1'-6")
UON
NOTE: ALL DEVICES INDICATED TO BE
INSTALLED AT DIFFERENT MOUNTING
HEIGHTS AND LOCATED WITHIN ONE
STUD SPACE FROM EACH OTHER
SHALL ALIGN VERTICALLY, ON THE
SAME SIDE OF THE STUD. WHERE WALL
MOUNTED TELEPHONES OCCUR OVER
LIGHT SWITCHES, VOLUME CONTROLS,
ETC. OFFSET ONE STUD SPACE.
HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE.
WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF
DOOR TRIM AND CEILING LINE.
MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE.
W
CONTROL PANELS
TOP
S
TOP
S
C
C
B
B
MD
MD
C
C
CR
VC
IC
NO SCALE
TYPICAL DEVICE MOUNTING HEIGHTS
KP
M
CB
EP
D
SP SS 44" (3'-8")
UON
TOILET
COUNTER
TOP
MS
DA
GB
GB
S
80" (6'-8")
UON
PROVIDE 10" SLEEVE OVER
THREADED ROD FOR CABLE
PROTECTION
TRAPEZE TYPE CABLE TRAY.
SUPPORT ACROSS BOTTOM
SIDE OF TRAY EVERY 8'
MAXIMUM.
THREADED ROD
DOUBLE NUT OR NYLOCK
NOTE: PROVIDE #10 COPPER GROUND CONDUCTOR IN WIRE BASKET. ATTACH WITHIN 6" OF
BASKET SECTIONS USING SPLIT BOLTS. TERMINATE GROUND ON TELECOM GROUND BAR.
WIRE BASKET DETAIL
NO SCALE
ALL WIRES AND CABLES SHALL BE SUPPORTED. MAXIMUM SPACING BETWEEN
HOOKS SHALL BE 4' to 5'. ATTACH HOOK ASSEMBLY TO BUILDING STRUCTURE.
ALL CABLE RUNS TO BE PERPENDICULAR AND PARALLEL TO BUILDING WALLS.
NOTE:
2"
4'-5' TO NEXT
ASSEMBLY (TYP.)
ATTACHED TO
STURCTURE AS
REQUIRED
3/8" ROD
LENGTH AS
REQUIRED
COMMUNICATION
CABLE J-HOOK.
QUANTITIES AS
REQUIRED.
CABLE SUPPORT SYSTEM DETAIL
NO SCALE
TO ACCESS
CONTROL PANEL
3/4" C. STUB
FLOOR LINE
SECURE AREA
3"
1/2" CONDUIT (STUBBED BEHIND
DRYWALL REFER TO NOTE 3)
FLUSH MOUNT DOOR CONTACT
SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4"
FROM OPENING SIDE OF DOOR.
IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING
JURISDICTION (AHJ).
NOTES:
MOUNT SJB AT 10' CENTER AFF
CEILING
2.
1.
4.
3.
SINGLE DOOR
NO SCALE
ELECTRIC
STRIKE
1/2" C.
48" AFF
CL
CARD READER 4"X4" BOX
W/SINGLE GANG MUD RING.
REFER TO FLOOR PLAN FOR
LOCATION.
1/2" C.
REQUEST TO EXIT DEVICE
MOUNT CENTERED ON
DOORS APPROXIMATLEY 12"
ABOVE DOOR FRAME
1/2" C.
(STUBBED BEHIND DRYWALL)
HINGE
SIDE
TO ACCESS
CONTROL PANEL
3/4" C. STUB
FLOOR LINE
SECURE AREA
SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4"
FROM OPENING SIDE OF DOOR.
IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING
JURISDICTION (AHJ).
NOTES:
MOUNT SJB AT 10' CENTER AFF
CEILING
2.
1.
4.
3.
SINGLE DOOR
NO SCALE
1/2" C. 1/2" C.
POWER SUPPLY
48" AFF TYP.
CL
PUSH PAD (TYP). REFER TO
FLOOR PLAN FOR LOCATION.
AUTO OP.
HINGE
SIDE
1/2" C. (STUBBED
BEHIND DRYWALL)
3/4" C. STUB
TO ACCESS
CONTROL PANEL
FLUSH MOUNT DOOR
CONTACT (TYP.)
CEILING
MOUNT SJB AT 10'
CENTER AFF
SECURE AREA
FLOOR LINE
6"
3"
NOTES:
SECURITY JUNCTION BOX (SJB) SHALL BE 6X6X6 WITH SCREW COVER.
ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM
OPENING SIDE OF DOOR.
IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING
JURISDICTION (AHJ).
DOUBLE DOOR
NO SCALE
3.
4.
1.
2.
CL
1/2" C.
CARD READER 4"X4"
J-BOXES W/SINGLE
GANG MUD RING.
REFER TO FLOOR
PLAN FOR LOCATIONS
48" AFF
1/2" C.
(STUBBED BEHIND
DRYWALL)
ELECTRIC
HINGE
HINGE
SIDE
HINGE
SIDE
REQUEST TO EXIT DEVICE
MOUNT CENTERED ON
DOORS APPROXIMATLEY 12"
ABOVE DOOR FRAME
1/2" C.
(STUBBED BEHIND DRYWALL)
TO ACCESS
CONTROL PANEL
3/4" C. STUB
FLOOR LINE
SECURE AREA
3"
1/2" CONDUIT (STUBBED
BEHIND
DRYWALL REFER TO NOTE 3)
FLUSH MOUNT DOOR CONTACTS
SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4"
FROM OPENING SIDE OF DOOR.
IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING
JURISDICTION (AHJ).
NOTES:
MOUNT SJB AT 10' CENTER AFF
CEILING
2.
1.
4.
3.
SINGLE DOOR
NO SCALE
48" AFF
CL
CARD READER 4"X4" BOX
W/SINGLE GANG MUD RING.
REFER TO FLOOR PLAN FOR
LOCATION.
1/2" C.
ELECTRIC
POWER
TRANSFER
1/2" C. (STUBBED
BEHIND DOOR FRAME)
REQUEST TO EXIT DEVICE
MOUNT CENTERED ON
DOORS APPROXIMATLEY
12"
ABOVE DOOR FRAME
1/2" C.
(STUBBED BEHIND DRYWALL)
3"
HINGE
SIDE
HINGE
SIDE
TO ACCESS
CONTROL PANEL
3/4" C. STUB
FLOOR LINE
SECURE AREA
SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING
JURISDICTION (AHJ).
NOTES:
MOUNT SJB AT 10' CENTER AFF
CEILING
2.
1.
3.
SINGLE DOOR
NO SCALE
INTEGRATED
CARD READER
1/2" C.
HINGE
SIDE
ELECTRIC
HINGE
1/2" C.
2901 Blake Street, Suite 100
Denver, CO 80205
303.861.8555
Denver
1
A
B
C
D
E
2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
DPA Project:
Sheet Number:
COPYRIGHT - DAVIS PARTNERSHIP, P.C.
Sheet Title:
Revisions Date
Sheet Information
Project Information
Issuance
Consultant
CENTRAL
WING
RENOVATION
3/10/2017
10:59:15 AM
15924.00
T-001.1
TECHNOLOGY LEGENDS &
NOTES
2017
03/10/17
PERMIT
VAIL
VALLEY
MEDICAL
CENTER
180 S. Frontage
Road
West,
Vail, CO 81657
06/30/17