HomeMy WebLinkAboutB17-0092_T-001.1_1508947722.pdfGENERAL NOTES: WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 1. 2. 3. 4. 5. 6. 7. DEMOLITION NOTES: UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES, ETC. TO BE REMOVED. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS. REWORK EXISTING TERMINATIONS, CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT CONTINUITY TO EXISTING CIRCUITS AND DEVICES TO REMAIN OR BE RELOCATED. PRIOR TO COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT SUPPORTS BACK TO POINT OF ORIGIN OR NEXT DEVICE TO REMAIN. REMOVED ITEMS SHALL BE TURNED OVER TO THE OWNER, UNLESS NOTED OTHERWISE, AND STORED IN THE AREA DESIGNATED BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER CHOOSES NOT TO ACCEPT. WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. REUSE EXISTING CONDUIT WHERE CURRENT NEC AND LOCAL CODE REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR NEW INSTALLATIONS AND EXTENSION OF EXISTING INSTALLATIONS. REUSE EXISTING CONDUIT IN PLACE, DO NOT REINSTALL EXISTING CONDUIT. PROVIDE LABELING PER SPECIFICATIONS FOR REUSED CONDUIT. RELOCATED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL FOREIGN MATERIAL. REPLACE EQUIPMENT OR DEVICES WHICH ARE DEFECTIVE OR DAMAGED DURING RELOCATION. WHERE EXISTING DEVICES ARE TO BE REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH. BLANK COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE, UNLESS NOTED OTHERWISE. 1. 2. 3. 4. 5. 6. 7. TECHNOLOGY PLAN NOTES: PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL TELE/DATA OUTLETS AND A/V JUNCTION BOXES. ROUTE 1" CONDUIT FROM EACH OUTLET TO ABOVE ACCESSIBLE CEILING UNLESS NOTED OTHERWISE. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. KEEP ALL EXPOSED CONDUITS TIGHT TO STRUCTURE. PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL SECURITY, CCTV,ACCESS CONTROL, AND TELEVISION OUTLETS. ROUTE 3/4" CONDUIT FROM EACH OUTLET TO ABOVE ACCESSIBLE CEILING UNLESS NOTED OTHERWISE. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. KEEP ALL EXPOSED CONDUITS TIGHT TO STRUCTURE. PROVIDE AN 8' SERVICE LOOP AT STATION END OF ALL CABLE RUNS. PROVIDE 25' SERVICE LOOP AT ALL WIRELESS ACCESS POINT LOCATIONS. TERMINATE 2 CAT6A CABLES IN A SURFACE MOUNT OULTLET BOX. HOMERUN ALL VOICE, DATA, TELEVISION, ACCESS CONTROL, SECURITY, AND CCTV CABLES TO DESIGNATED CONTROL PANELS, PATCH PANELS, OR WALL FIELDS IN NEAREST TELECOMMUNICATION ROOM LOCATED IN THE SAME ZONE. PROVIDE J-HOOK TYPE CABLE SUPPORTS EVERY FOUR TO FIVE FEET TO SUPPORT CABLES IN ROUTE TO CABLE TRAY OR CONDUIT PATHWAYS TO TELECOMMUNICATIONS ROOM. ROUTE CABLE SUPPORTS SUCH THAT CABLE VISIBILITY WILL BE MINIMIZED IN ANY OPEN CEILING AREAS. HANG LADDER RACK ABOVE THE POD FROM THE CEILING UTILIZING A TRAPEZE STYLE SUPPORT SYSTEM EVERY 5 TO 6 FEET. PROVIDE A RARITAN PX3-1749V2N1 PDU FOR 18 CABINETS FOR A & B POWER (36 TOTAL). PROVIDE APC AP780 METERED 20A, 120V PDU FOR 10 CABINETS FOR A & B POWER (20 TOTAL). INSTALL DATA, COAX, AND TV CONTROL RJ-45 IN SAME FACE PLATE TYPICAL AT EACH TV LOCATION IN PATIENT ROOMS. ALL OTHER TV LOCATIONS INSTALL COAX AND DATA OUTLETS IN SAME FACE PLATE. COORDINATE NURSE CALL DEVICE BACK BOX AND CONDUIT REQUIREMENTS WITH VENDOR PRIOR TO INSTALLATION. PROVIDE (2) 1-1/4" CONDUITS FROM LOW VOLTAGE COMPARTMENTS OF FLOOR BOX/POKE THRU TO ABOVE ACCESSIBLE CEILING ON THE SAME LEVEL. PROVIDE ANY REQUIRED FACE PLATES, INSERTS, AND BLANKS TO COMPLETE INSTALLATION. PROVIDE OBERON CEILING ENCLOSURE FOR EACH WIRELESS ACCESS POINT DEVICE. MATCH ENCLOSURE TO CEILING TYPE AND CURRENT DEVICE TYPE. REFER TO HEADWALL SYSTEMS SHOP DRAWINGS FOR EXACT LOW VOLTAGE SYSTEMS DEVICE ELEVATIONS. COORDINATE BOX REQUIREMENTS AND CABLE ROUTING WITH VENDOR. PROVIDE 3 YEARS OF LICENSING AND ANY REQUIRED SYSTEM SET UP FOR PRIMEX ONE-VUE WIRELESS SYNCHRONIZED CLOCK SYSTEM. OWNER SHALL PROVIDE CLOCKS - CONTRACTOR SHALL INSTALL. PROVIDE HOSPITAL PAGE, LOCAL PAGE, AND BACKGROUND MUSIC AS PRIORITIZED INPUTS FOR HOWARD HEAD SUITE. EXISITNG CONDITIONS REQUIRE NEW AND TEMPORARY RISER FEEDS TO EXISTING TELECOM ROOM. CABLING TO EXISTING DEVICES WILL ALSO NEED TO BE REPLACED OR RE-ROUTED. REMOVE/RELOCATE DEVICES AND EQUIPMENT IN EXISTING TELECOM ROOMS. PROTECT TEMPORARY AND EXISTING CABLING DURING PHASED CONSTRUCTION. REFER TO DRAWINGS FOR AREAS THAT CONTAIN DEVICES AFFECTED BY SCOPE OF PROJECT. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL, CEILING, AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH-IN. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY ADVERSE FIELD CONDITIONS PRIOR TO PERFORMING ANY WORK. PROVIDE 4" SQUARE JUNCTION BOX WITH SINGLE GANG MUD RING AT EACH CLOCK LOCATION. ROUTE 3/4" CONDUIT TO ACCESSIBLE CEILING. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REFERENCE SYMBOLS LEGEND (Not all symbols listed below are used on these drawings) KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE MECHANICAL EQUIPMENT REFERENCE EXISTING TO REMAIN EXISTING TO BE REMOVED EXISTING TO BE RELOCATED EXISTING TO REMAIN - REPLACE DEVICE DESCRIPTION DESCRIPTIONSYMBOL 1 1 UH E R RL ER TECHNOLOGY LEGEND (Not all symbols listed below are used on these drawings) TELEPHONE TERMINAL CABINET TELEPHONE TERMINAL BACKBOARD ELECTRIC HINGE ELECTRIC POWER TRANSFER ELECTRIC DOOR LOCK ELECTRIC DOOR STRIKETELE/DATA OUTLET, FLOOR MOUNTED (#=QTY OF CABLES) SECURITY CONTROL PANEL POWER SUPPLY MOTION DETECTOR (WALL MOUNTED) MAGNETIC DOOR LOCK GLASS BREAK DETECTOR (CEILING MOUNTED) GLASS BREAK DETECTOR (WALL MOUNTED) TELEPHONE/POWER POLE INTERCOM STATION KEYPADMICROPHONE STATION DESCRIPTIONSYMBOLDESCRIPTION SYMBOL SYMBOL CR CARD READER (IL = INTEGRATED LOCK) DOOR CONTACT EH EP EL ES GB IC KPM ML MD PS SEC VC WAP GBVOLUMN CONTROL WIRELESS ACCESS POINT TELEVISION OUTLET CLOCK OUTLET (D= DOUBLE SIDED) PUSH BUTTON PAGING SYSTEM SPEAKER PAGING SYSTEM HORN (HIGH OUTPUT) BOX SPEAKER - SURFACE MOUNT SECURITY CAMERA PROJECTOR T P D S S C S TELE/DATA OUTLET (#=QTY OF CABLES) FLAG NOTE REFERENCE W TELEPHONE, WALL MOUNTED REQUEST TO EXITRX DURESS ALARM DA MOTION DETECTOR (CEILING MOUNTED)MD DAS DONNER ANTENNA ABBREVIATIONS LEGEND ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE RAISED FLOOR BELOW FINISHED GRADE MINIMUM NORMALLY CLOSED NORMALLY OPEN NOT TO SCALE CONDUIT CABLE TELEVISION CLOSED CIRCUIT TELEVISION EXISTING EMERGENCY EXPLOSION PROOF FIRE ALARM GROUND LOCK DOWN WEATHER PROOF WITHOUT WITH UNINTERRUPTABLE POWER SUPPLY UNLESS OTHERWISE NOTED UNDER GROUND UNDER FLOOR TYPICAL TRANSIENT VOLTAGE SURGE SUPPRESSER TAMPER PROOF STAND-BY PULL BOX ON SITE WORK FORCE OWNER FURNISHED, OWNER INSTALLED OWNER FURNISHED, CONTRACTOR INSTALLED ON CENTER ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH NOT IN CONTRACT DESCRIPTION SYMBOL DESCRIPTION SYMBOL (Not all symbols listed below are used on these drawings) LD G FA EP EM (E) CCTV CATV C BFG ARF AFG AFF AC WP W/O W/ UPS UON UG UF TYP TVSS TP SB PB OSWF OFOI OFCI OC NTS NO NIC NC MIN MAXIMUMMAX TIME CLOCKTC PIEZO/SOUNDERPZ ELECTRIC WHITE BOARDEWB BIO-HAZARD BIO ELAPSE TIME CLOCKETC WIREMOLDWM # # TELE/DATA OUTLET, CEILING MOUNTED (# = QTY OF CABLES)# IL NURSE CALL BACKBOX (Not all symbols listed below are used on these drawings) MOUNTING HEIGHTBACKBOXDESCRIPTION SYMBOL 2J 2 INPUT AUXILIARY JACK BOX WITH SINGLE-GANG RING VERIFY WITH LOCAL AHJ 54" A.F.F. PS SINGLE PATIENT STATION 3-GANG BACK BOX, DEEP WITH PLASTER RING AN ANNUNCIATOR CB 54" A.F.F. BM BED MANAGEMENT/HOUSEKEEPING 54" A.F.F. CODE STATION WITH STAFF ASSIST PERIPHERAL STATION SA 54" A.F.F.STAFF ASSIST STATION EP 45" A.F.F.CALL CORD STATION DOME LIGHT DOME ZONE LIGHT BI BED RECEPTACLE, SINGLE 37-PIN DSUB Z DUAL PATIENT STATION SMART STAFF/DUTY STATION CEILING/ABOVE OR NEXT TO DOOR MS MASTER STATION STAFF DESKTOP CONSOLE DESKTOP STAFF STATION 54" A.F.F. RL RTLS STAFF LOCATOR 24" A.F.F. 3-GANG RING ON A DEEP BOX 4" SQUARE BOX WITH SINGLE-GANG RING 4" SQUARE BOX WITH SINGLE-GANG RING 4" SQUARE BOX WITH SINGLE-GANG RING DEEP BOX WITH SINGLE-GANG RING 2-GANG DEEP BACK BOX 2-GANG BACK BOX 4" SQUARE BOX WITH SINGLE-GANG RING 3-GANG BACK BOX, DEEP WITH PLASTER RING BOX WITH 3-GANG RING BOX WITH 3-GANG RING NO BOX REQUIRED 54" A.F.F. 54" A.F.F. CEILING/ABOVE OR NEXT TO DOOR 54" A.F.F. 45" A.F.F. CEILING MOUNT ASCOM MFG ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM ASCOM CBSA Z DP DS SS TOP OF CABINET 84" (7'-0") UON96" (8'-0") UON72" (6'-0") UON54" (4'-6") UON48" (4'-0") UONTYPICAL 9'-0" CEILING OR HIGHER TYPICAL 8'-0" CEILING 2. 3. NOTES: 1. FINISHED FLOOR18" (1'-6") UONNOTE: ALL DEVICES INDICATED TO BE INSTALLED AT DIFFERENT MOUNTING HEIGHTS AND LOCATED WITHIN ONE STUD SPACE FROM EACH OTHER SHALL ALIGN VERTICALLY, ON THE SAME SIDE OF THE STUD. WHERE WALL MOUNTED TELEPHONES OCCUR OVER LIGHT SWITCHES, VOLUME CONTROLS, ETC. OFFSET ONE STUD SPACE. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. W CONTROL PANELS TOP S TOP S C C B B MD MD C C CR VC IC NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS KP M CB EP DSP SS 44" (3'-8") UONTOILE T COUNTER TOPMS DA GB GB S 80" (6'-8") UONPROVIDE 10" SLEEVE OVER THREADED ROD FOR CABLE PROTECTION TRAPEZE TYPE CABLE TRAY. SUPPORT ACROSS BOTTOM SIDE OF TRAY EVERY 8' MAXIMUM. THREADED ROD DOUBLE NUT OR NYLOCK NOTE: PROVIDE #10 COPPER GROUND CONDUCTOR IN WIRE BASKET. ATTACH WITHIN 6" OF BASKET SECTIONS USING SPLIT BOLTS. TERMINATE GROUND ON TELECOM GROUND BAR. WIRE BASKET DETAIL NO SCALE ALL WIRES AND CABLES SHALL BE SUPPORTED. MAXIMUM SPACING BETWEEN HOOKS SHALL BE 4' to 5'. ATTACH HOOK ASSEMBLY TO BUILDING STRUCTURE. ALL CABLE RUNS TO BE PERPENDICULAR AND PARALLEL TO BUILDING WALLS. NOTE: 2" 4'-5' TO NEXT ASSEMBLY (TYP.) ATTACHED TO STURCTURE AS REQUIRED 3/8" ROD LENGTH AS REQUIRED COMMUNICATION CABLE J-HOOK. QUANTITIES AS REQUIRED. CABLE SUPPORT SYSTEM DETAIL NO SCALE 2901 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Denver 1 A B C D E 2 3 4 5 6 A B C D E 1 2 3 4 5 6 DPA Project: Sheet Number: COPYRIGHT - DAVIS PARTNERSHIP, P.C. Sheet Title: Revisions Date Sheet Information Project Information Issuance Consultant CENTRAL WING RENOVATION 7/10/2017 1:44:56 PM15924.00 T-001.1 TECHNOLOGY LEGENDS & NOTES 07/11/17PERMIT RESUBMISSION EAST WING ADDITION 180 S Frontage Rd W, Vail, CO 8165710/25/17