HomeMy WebLinkAboutB16-0473_A107_1483477524.pdfWD
5
0 5 10 20
A A A
2'-0" 2'-6" 2'-6" 2'-0"
C
F
A A
A A
3'-8" 3'-8" 3'-8"
A A
A A
A A
NEW <400CFM
VENT HOOD
DEMO
F
DEMO
T
T
E
E
E
E E
E
REPLACE OR WRAP EXTG
LOG RIDGE BEAM W/SQUARE
BEAM OR TRIM
H
J
L L
+9'-4"
F
F
A A
L
A
L L L
DEMO FLUOR
UP-LIGHT (x4)
1'-3"
3'-0"
8'-0"
4'-0"
A A
1'-2"
1'-2"
+15'-0"
+9'-1"
+9'-1"
A
A
SLOPING
SLOPING
TV HDMI
+42", VFY HT AND
LOW VOLT REQM'TS
BRIDGE
OVHD
D
22OV
+42" M D M D
NEW TIMBER DROPPED
BEAMS, RE: STRUCT.
WRAP EXTG DROPPED BEAM
W/TRIM TO MATCH TIMBERS
A A
A A
A A
3'-0"
9"
9"
G G G G
M
D 3 G G
4'-0" 6'-0" 6'-0" 6'-0"
EQ 1
2" EQ 3'-01
2" EQ 3'-11"
EQ
3'-11"
D J J J
3
3 A A A
2'-0"
3'-41
2" 3'-4"
A A
1'-11"
1'-11"
2'-4"
2'-4"
s
s
A
A
A
A
A
A MOTION
M
M
M M M
M D D D
D
+32"
+32"
LIGHT AND VENTILATION
PER IRC R303.3
GENERAL ELECTRICAL NOTES:
1. POWER AND LIGHTING DISTRIBUTION TO
FOLLOW REQUIREMENTS PER 2015 IRC
2. POWER AND LIGHTING TO CONFORM TO
THE 2014 NATIONAL ELECTRIC CODE.
2. PER 2015 IECC, 75% OF ALL NEW LIGHTING
TO BE HIGH EFFICACY
3. ALL EXISTING OUTLETS & SWITCHES TO
REMAIN, MODIFICATIONS AS SHOWN ON
PLANS, VFY NEW SWITCH LOCATIONS
4. ELECTRICAL WALK-THRU IS REQUIRED
WITH ARCHITECT AT ROUGH-IN
5. TYPICAL COLOR OF OUTLETS, SWITCHES,
AND COVERS (LUTRON ARCHITECTURAL
MATTE): ALMOND (AL) DRYWALL
LOCATIONS; BROWN (BR) STONE &
NATURAL WOOD LOCATIONS, VERIFY.
6. TYPICAL SWITCH HEIGHTS: 48" AFF TO
THE TOP OF SWITCH BOX FOR STANDARD
SWITCHES, +42" AFF TTT FOR BESIDE
SWITCHES
7. ALL RECESSED CANS TO BE ON DIMMERS,
EXCEPT CLOSETS
8. LED LIGHT COLOR TEMPERATURES:
CLOSETS AND BATHS = 4000K (WHITE)
ALL OTHER LOCS = 3000K (WARM WHITE)
CEILING FAN
LIGHTING SYMBOLS
BATHROOM EXHAUST FAN
TV 2 RG6 COAXIAL
s
DUPLEX OUTLET, +12" U.O.N.
SWITCH
DIMMER
MULTIPLE SWITCH
3-WAY SWITCH
RECESSED LENSED SHOWER LIGHT
QUAD OUTLET
3
M
D
F
24" LED UNDER CABINET LIGHT
COMBO. DATA/TELEPHONE OUTLET
NEW NATURAL GAS LINE
DUPLEX FLOOR OUTLET
INFLOOR DATA AND QUAD
POWER OUTLET
INFLOOR DATA AND DUPLEX
POWER OUTLET
DUPLEX OUTLET, HALF
SWITCHED +12" U.O.N.
SWITCH IN JAMB
J
HB
HOSE BIB
A
EXTERIOR WALL SCONCE
NEW JUNCTION BOX
J
L
RECESSED CAN LIGHT:
ADJUSTABLE &/OR SLOPED TRIM
FIXED DOWN LIGHT
RECESSED CAN LIGHT:
SURFACE MOUNTED LIGHT FIXTURE
A
GROUND FAULT DUPLEX OUTLET,
+42" U.O.N.
A-24
PENDANT LIGHT
A
F
L
BATHROOM EXHAUST FAN
WITH LIGHT
COMBINATION SMOKE AND
CARBON MONOXIDE DETECTOR
DUPLEX FLOOR OUTLET,
HALF SWITCHED
A
CEILING MOUNTED LIGHT FIXTURE
EXTERIOR PENDANT LIGHT
A
T THERMOSTAT
A107
RCP
P R O J E C T :
1714 BUFFEHR
CREEK
ROAD
D R A W N B Y :
D A T E :
R E V I S I O N S :
LOT 3, LIA ZNEIMER
SUBDIVISION
VAIL, COLORADO
11.04.16
-
1714B-16
1
1/4" = 1'-0"
MAIN LEVEL REFLECTED CEILING PLAN
01/03/17