Loading...
HomeMy WebLinkAboutB16-0153_A0.09_1479389395.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. WALL SYSTEMS: RATED ASSEMBLIES (@ MAIN & UPPER LEVELS): F1-W VINYL PLANK ON GYPCRETE Vinyl plank installed per manufacturer's specifications, over 1 1/2" thick light concrete underlayment over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "x"gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. F1-C CARPET ON GYPCRETE Carpet and pad, installed per manufacturer's specifications, over 1 1/2" thick light weigth concrete underlayment over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "X" gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. C1 GYPSUM BOARD CEILING CONSTRUCTION (1Hr-Rated) UL DESIGN NO. L521 & UL P533 5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses or joists. (TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies. CEILING SYSTEMS: FLOOR SYSTEMS: Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. NOTES ** Interior Walls Studs: 4 - 2x4 Wood Studs 6 - 2x6 Wood Studs 8 - 2x8 Wood Studs RE: See wall tags for stud sizes. **** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where recommended by manufacturer. Maintain required fire-rating. Refer to Structural Drawings for Bearing Walls and Shear Walls. RATED ASSEMBLIES (EXTERIOR): W1-1 WOOD SIDING @ RATED EXTERIOR WALLS Wood siding over (1) layer of Tyvek building wrap on structural sheathing (per structural design) @ exterior face of 2x6 dimensional lumber studs w/ min. R-21 closed cell spary-in faom insualtion between studs. (1) layer 5/8" gypsum board @ interior face of studs. Interior finish will be paint or FRP panels, see room finish schedule for finish. (Re: Structural for size and spacing of studs and sheathing). W1-2 STUCCO @ RATED EXTERIOR WALLS 3 coat stucco system over self-furring metal lathe over 15 lb asphaltic building paper, 2x6 dimensional lumber studs w/ R-21 closed cell spary-in faom insualtion between studs. (1) layer 5/8" gypsum board @ interior face of studs. (Re: Structural for size and spacing of studs and sheathing). NON-RATED ASSEMBLIES (INTERIOR): W4-*** GYPSUM BOARD PARTITION ON 2X DIMAENSIONAL LUMBER STUDS (Non-Rated) (1) Layer 5/8" gypsum board**** on each side of 2x dimensional lumber studs at non-bearing walls, demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing). W5- GYPSUM BOARD OVER FURRING (Non-Rated) (1) Layer 5/8" gypsum board**** over 1 1/2" metal furring strips @ 16" O.C. with 1 1/2" rigid insulation. (Re. Structural for size and spacing). (1Hr-Rated), R-50 R1 NEW METAL ROOF CONSTRUCTION: New metal roof to match existing metal roof. Install over Vycor ice and water sheild. Note: Install ice and water 24" up at vertical wall interface. Typical. Note: Install snow retention system and heat tape in accordance with manufacturer's instructions. 110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119), Miami Dade Code Approval ROOF SYSTEMS: 5/8" GYPSUM WALL BOARD 3 1/2" W3-1 2X4 DIMENSIONAL LUMBER, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. SOUND BATTS 5/8" GYPSUM WALL BOARD 5 1/2" W3-2 2X6 DIMENSIONAL LUMBER, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. SOUND BATTS 2X6 DIMENSIONAL LUMBER 5/8" GYPSUM WALL BOARD INTERIOR EXTERIOR CLOSED CELL SPRAY-IN INSULATION, R-21 MIN. BUILDING WRAP STRUCTURAL SHEATHING, RE: STRUCTURE W1-1 5/8" GYP. = 40 MIN. 2x8 FRAMING @ 16" O.C.= 20 MIN. BATT INSULATION = 15 MIN. FIRE RATING (1-HOUR MIN.) : SHEATHING = 20 MIN. CEMENTITIOUS SIDING 2X6 DIMENSIONAL LUMBER 5/8" GYPSUM WALL BOARD INTERIOR EXTERIOR CLOSED CELL SPRAY-IN INSULATION, R-21 MIN. BUILDING WRAP STRUCTURAL SHEATHING, RE: STRUCTURE W1-3 5/8" GYP. = 40 MIN. 2x8 FRAMING @ 16" O.C.= 20 MIN. BATT INSULATION = 15 MIN. FIRE RATING (1-HOUR MIN.) : SHEATHING = 20 MIN. MORTAR SETTING BED 2 1/2" STONE VENEER SELF-FURRING METAL LATHE 5/8" GYPSUM WALL BOARD, TYPE X, TYP. 5 1/2" 1 1/2" W2-1 2X6 DIMENSIONAL LUMBER @ 16" O.C.,TYP. 1 1/4" 1 1/2" 5 1/2" 1" 1" AIR CAVITY, TYP. BATT INSULATION, TYP. 5/8" GYP. = 40 MIN. X6 FIRE RATED: 2 HOUR MIN. 2x8 FRAMING (X2) @ 16" O.C.= 20 MIN. X2 BATT INSULATION = 15 MIN. X2 FIRE RATING (2-HOUR MIN.) : 7/8" RESILIENT CHANNEL, TYP. 5/8" GYPSUM WALL BOARD, TYPE X, TYP. 5 1/2" W2-2 2X6 DIMENSIONAL LUMBER @ 16" O.C.,TYP. BATT INSULATION, TYP. 5/8" GYP. = 40 MIN. x2 FIRE RATED: 1 HOUR MIN. 2x8 FRAMING (X2) @ 16" O.C.= 20 MIN. BATT INSULATION = 15 MIN. FIRE RATING (1-HOUR MIN.) : INTERIOR GARAGE FOUNDATION WALL, RE: STRUCTURE, TYP. 5/8" GYPSUM WALL BOARD W3-3 1 1/2" METAL FURRING @ 16" O.C., TYP. 1 1/2" RIGID INSULATION BETWEEN FURRING, TYP. WALL ASSEMBLIES EXTERIOR WALL ASSEMBLIES: INTERIOR WALL ASSEMBLIES: NOTE: ALL EXTERIOR WALLS TO HAVE A FIRE RATING OF 1 HOUR MINIMUM. STRUCTURE TO HAVE FIRE SPRINKLER SYSTEM. FIRE RATED ASSEMBLIES: NON-RATED ASSEMBLIES 2X6 DIMENSIONAL LUMBER 5/8" GYPSUM WALL BOARD INTERIOR SELF FURRING LATH EXTERIOR 1 LAYER ASPHALTIC BUILDING PAPER STRUCTURAL SHEATHING, RE: STRUCTURE W1-2 5/8" GYP. = 40 MIN. 2x6 FRAMING @ 16" O.C.= 20 MIN. BATT INSULATION = 15 MIN. FIRE RATING (1-HOUR MIN.) : SHEATHING = 20 MIN. 3 COAT STUCCO SYSTEM CLOSED CELL SPRAY-IN INSULATION, R-21 MIN. 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 716 FOREST RD VAIL, CO 81657 A0.09 ASSEMBLIES 716 FOREST RD - UNIT A Project Number - 1464 04/18/16 PERMIT SET 1 1/2" = 1'-0" 6 INTERIOR PARTITIOIN (2x4) W3-1 1 1/2" = 1'-0" 7 INTERIOR PARTITION (2x6) W3-2 3" = 1'-0" 1 WOOD SIDING W1-1 3" = 1'-0" 3 STONE SIDING W1-3 1 1/2" = 1'-0" 4 INTERIOR UNIT SEPARATION W2-1 1 1/2" = 1'-0" 5 GARAGE SEPARATION W2-2 1 1/2" = 1'-0" 8 FOUNDATION WALL W/ FINISH W3-3 3" = 1'-0" 2 STUCCO FINISH W1-2 05/25/16