HomeMy WebLinkAboutB16-0153_A6.01_1478901955.pdfWINDOW
A
WINDOW
STYLE
WINDOW
ELEVATION
WINDOW
C
SILL HT.
WINDOW
D
WINDOW
B
WINDOW
E
FIXED FIXED TRAPAZOID
FIXED PENTAGON
SILL HT.
CASEMENT AWNING
CASEMENT
SILL HT.
SILL HT.
TYPE A
DOOR
STYLE
SLIDING GLASS
DOOR
ELEVATION
TYPE B
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
716 FOREST RD
VAIL, CO 81657
A6.01
WINDOW
SCHEDULE - A
716 FOREST RD - UNIT A
Project
Number - 1464
04/18/16
PERMIT SET
1/4" = 1'-0"
WINDOW LEGEND
1/4" = 1'-0"
SLIDING GLASS DOOR LEGEND
WINDOW SCHEDULE - UNIT A
MARK LOCATION FLOOR WINDOW STYLE FRAME WIDTH FRAME HEIGHT X2(SILL HEIGHT) MANUFACTURER
1a UNIT A BASEMENT - A B 2' - 4 1/2" 4' - 10" MATCH EXISTING Based on JELD-WEN single hung window
2a UNIT A BASEMENT - A B 2' - 4 1/2" 4' - 10" MATCH EXISTING Based on JELD-WEN single hung window
3a UNIT A LIVING - A B 4' - 6" 6' - 0" MATCH EXISTING Based on JELD-WEN single hung window
4a UNIT A LIVING - A A 4' - 6" 6' - 0" MATCH EXISTING Based on JELD-WEN single hung window
5a UNIT A LIVING - A B 4' - 6" 6' - 0" MATCH EXISTING Based on JELD-WEN single hung window
6a UNIT A LIVING - A C 4' - 6" 2' - 0" MATCH EXISTING Based on JELD-WEN single hung window
7a UNIT A LIVING - A C 4' - 6" 2' - 0" MATCH EXISTING Based on JELD-WEN single hung window
8a UNIT A LIVING - A C 4' - 6" 2' - 0" MATCH EXISTING Based on JELD-WEN single hung window
9a UNIT A LIVING - A A 5' - 7 1/2" 1' - 6" MATCH EXISTING Based on JELD-WEN single hung window
10a UNIT A MAIN - A C 3' - 0" 3' - 0" 4' - 0" Based on JELD-WEN single hung window
11a UNIT A MAIN - A A 3' - 0" 3' - 0" 2' - 6" Based on JELD-WEN single hung window
12a UNIT A UPPER - A B 3' - 6" 5' - 0" 3' - 0" Based on JELD-WEN single hung window
13a UNIT A UPPER - A A 3' - 6" 5' - 0" 3' - 0" Based on JELD-WEN single hung window
14a UNIT A UPPER - A B 3' - 6" 5' - 0" 3' - 0" Based on JELD-WEN single hung window
15a UNIT A UPPER - A B 3' - 6" 5' - 0" 3' - 0" Based on JELD-WEN single hung window
16a UNIT A UPPER - A A 3' - 6" 5' - 0" 3' - 0" Based on JELD-WEN single hung window
17a UNIT A UPPER - A B 3' - 6" 5' - 0" 3' - 0" Based on JELD-WEN single hung window
18a UNIT B LIVING - A D 3' - 8" 4' - 10" 9' - 0" Based on JELD-WEN single hung window
19a UNIT B LIVING - A D 3' - 8" 3' - 0" 9' - 0" Based on JELD-WEN single hung window
20a UNIT B LIVING - A A 3' - 8" 7' - 0" 2' - 0" Based on JELD-WEN single hung window
21a UNIT B LIVING - A A 3' - 8" 7' - 0" 2' - 0" Based on JELD-WEN single hung window
22a UNIT A UPPER - A B 3' - 0" 4' - 0" 3' - 0" Based on JELD-WEN single hung window
23a UNIT A UPPER - A D 3' - 8" 6' - 2" 4' - 6" Based on JELD-WEN single hung window
24a UNIT A UPPER - A D 3' - 8" 6' - 2" 4' - 6" Based on JELD-WEN single hung window
25a UNIT A UPPER - A A 3' - 0" 3' - 6" 4' - 6" Based on JELD-WEN single hung window
26a UNIT A MAIN - A B 3' - 6" 5' - 0" 2' - 6" Based on JELD-WEN single hung window
27a UNIT A MAIN - A A 3' - 8" 5' - 0" 2' - 6" Based on JELD-WEN single hung window
28a UNIT A MAIN - A B 3' - 6" 5' - 0" 2' - 6" Based on JELD-WEN single hung window
29a UNIT A UPPER MASTER - A D 3' - 8" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
30a UNIT A UPPER MASTER - A D 3' - 8" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
31a UNIT A UPPER MASTER - A A 3' - 8" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
32a UNIT A UPPER MASTER - A A 3' - 8" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
33a UNIT A UPPER MASTER - A B 3' - 0" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
34a UNIT A UPPER MASTER - A A 3' - 0" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
35a UNIT A UPPER MASTER - A B 3' - 0" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
36a UNIT A UPPER MASTER - A A 3' - 0" 6' - 0" 8' - 0" Based on JELD-WEN single hung window
37a UNIT A UPPER MASTER - A A 3' - 0" 6' - 0" 8' - 0" Based on JELD-WEN single hung window
38a UNIT A UPPER MASTER - A A 3' - 0" 6' - 0" 8' - 0" Based on JELD-WEN single hung window
39a UNIT A UPPER MASTER - A B 3' - 0" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
40a UNIT A UPPER MASTER - A A 3' - 0" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
41a UNIT A UPPER MASTER - A A 1' - 6" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
42a UNIT A UPPER MASTER - A B 3' - 0" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
43a UNIT A UPPER MASTER - A B 3' - 0" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
44a UNIT A UPPER MASTER - A B 3' - 0" 7' - 0" 1' - 0" Based on JELD-WEN single hung window
45a UNIT A UPPER MASTER - A A 3' - 0" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
46a UNIT A UPPER MASTER - A A 3' - 0" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
47a UNIT A UPPER MASTER - A A 1' - 6" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
48a UNIT A UPPER MASTER - A A 3' - 0" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
49a UNIT A UPPER MASTER - A A 3' - 0" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
50a UNIT A UPPER MASTER - A A 3' - 0" 3' - 0" 8' - 0" Based on JELD-WEN single hung window
51a UNIT A LIVING - A A 3' - 6" 2' - 0" MATCH EXISTING Based on JELD-WEN single hung window
52a UNIT A LIVING - A A 3' - 6" 6' - 0" MATCH EXISTING Based on JELD-WEN single hung window
SLIDING GLASS DOOR SCHEDULE - UNIT A
DOOR # STYLE LOCATION WIDTH HEIGHT
S1a A MASTER BEDROOM 6' - 0" 8' - 0 1/2"
S2a A LIVING ROOM 6' - 4 1/2" 7' - 0 1/2"
05/25/16