' nh Compliance Certificate
Project Davos Trail Residence
Energy Code: 2015 IECC
Location: Vail, Colorado
Construction Type: Single-family
Project Type: Alteration
Climate Zone: 6 (9248 HDD)
Permit Date:
Permit Number: B16-0209
Construction Site: Owner/Agent: Designer/Contractor:
2636 Davos Trail Randy Fischer Randy Fischer
Vail, CO 81657 2695 Davos Trail Division Six Construction
Vail, CO 81657 2695 Davos Trail
970-306-3030 Vail, CO 81657
randy@divisionsixconst.com 970-306-3030
randy@divisionsixconst.com
Compliance: Passes using prescriptive requirements for alteration projects
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Flat Roof- 2x12: Flat Ceiling or Scissor Truss 255 57.0 0.0 0.024 6
Sloped Roof Entry- 2x10: Cathedral Ceiling 125 49.0 0.0 0.022 3
Sloped Roof- 14"TJI: Cathedral Ceiling 1,043 57.0 0.0 0.019 20
Flat Roof- 2x12: Flat Ceiling or Scissor Truss 210 57.0 0.0 0.024 5
Sloped Roof- Kitchen 2x12: Cathedral Ceiling 218 60.0 0.0 0.018 4
South Elevation: Wood Frame, 16" o.c. 1,071 23.0 7.0 0.038 34
South Elevation -Windows- U.29: Wood Frame:Double Pane with Low-E 112 0.290 32
South Elevation Windows- U.30: Wood Frame:Double Pane with Low-E 12 0.300 4
South Elevation Windows- U.33: Wood Frame:Double Pane with Low-E 16 0.330 5
South Elevation Windows- U.35: Wood Frame:Double Pane with Low-E 21 0.350 7
South Elevation - Doors (Glass): Glass 21 0.290 6
East Elevation: Wood Frame, 16" o.c. 1,107 24.0 7.0 0.037 29
East Elevation-Windows- U.25: Wood Frame:Double Pane with Low-E 9 0.250 2
East Elevation-Windows- U.26: Wood Frame:Double Pane with Low-E 66 0.260 17
East Elevation-Windows- U.27: Wood Frame:Double Pane with Low-E 24 0.270 6
East Elevation-Windows- U.28: Wood Frame:Double Pane with Low-E 9 0.280 3
East Elevation-Windows- U.29: Wood Frame:Double Pane with Low-E 68 0.290 20
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 1 of11
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
East Elevation-Windows- U.30: Wood Frame:Double Pane with Low-E 56 0.300 17
East Elevation-Windows- U.31: Wood Frame:Double Pane with Low-E 14 0.310 4
East Elevation-Windows- U.33: Wood Frame:Double Pane with Low-E 34 0.330 11
East Elevation-Windows- U.35: Wood Frame:Double Pane with Low-E 27 0.350 9
East Elevation- Door(Glass): Glass 20 0.290 6
North East Elevation: Wood Frame, 16" o.c. 1,169 24.0 7.0 0.037 37
North East Elevation -Windows- U.25: Wood Frame:Double Pane with Low-E 19 0.250 5
North East Elevation -Windows- U.26: Wood Frame:Double Pane with Low-E 12 0.260 3
North East Elevation -Windows- U.28: Wood Frame:Double Pane with Low-E 18 0.280 5
North East Elevation -Windows- U.33: Wood Frame:Double Pane with Low-E 20 0.330 7
North East Elevation - Doors: Glass 90 0.290 26
West Elevation: Wood Frame, 16" o.c. 546 24.0 7.0 0.037 15
West Elevation-Windows- U.27: Wood Frame:Double Pane with Low-E 5 0.270 1
West Elevation-Windows- U.29: Wood Frame:Double Pane with Low-E 60 0.290 17
West Elevation-Windows- U.33: Wood Frame:Double Pane with Low-E 40 0.330 13
West Elevation- Doors- U.29- Entry: Glass 13 0.290 4
West Elevation- Doors- U.33 - Elevator: Glass 15 0.330 5
South West Elevation (Garage/Front): Wood Frame, 16" o.c. 430 24.0 7.0 0.037 8
South West Elevation -Windows- U.31: Wood Frame:Double Pane with Low-E 9 0.310 3
South West Elevation -Windows- U.33: Wood Frame:Double Pane with Low-E 8 0.330 3
South West Elevation - Doors- U.33: Glass 14 0.330 5
South West Elevation -Garage Doors: Solid 150 0.080 12
South West Elevation - Doors- U.29: Glass 44 0.290 13
North West Elevation (Garage/Side): Wood Frame, 16" o.c. 330 24.0 7.0 0.037 11
North West Elevation -Windows- U: Wood Frame:Double Pane with Low-E 12 0.330 4
North West Elevation - Doors: Glass 12 0.290 3
South East Elevation (Garage/Side): Wood Frame, 16" o.c. 206 24.0 7.0 0.037 8
:Lower Level Existing SOG - Exposed Edge: Slab-On-Grade:Unheated 78 10.0 0.684 53
Insulation depth: 4.0'
Main Level SOG - Exposed Edge: Slab-On-Grade:Heated 16 15.0 0.655 10
Insulation depth: 4.0'
Main Level -Overhangs: All-Wood Joist/Truss:Over Outside Air 203 40.0 7.0 0.021 4
Basement Wall (50% below Grade): Solid Concrete or Masonry 915 13.0 10.0 0.036 33
Wall height: 7.5'
Depth below grade: 7.0'
Insulation depth: 7.5'
Mechanical Equipment
Description Fuel type Efficiency
Gas-Fired Steam Gas 95 AFUE
Air Source Electric 7.7 HSPF, 13 SEER
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 2 of11
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 3 of11
RInspectionEScheck Software VersionChecklist 4.6.2
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and Complies Requirement will be met.
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
V, building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ['Not Observable
Systems serving multiple ENot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr EDoes Not
[PR2]2 on loads calculated per ACOA Cooling: Cooling:
Manual J or other methods ['Not Observable
approved by the code official. Btu/hr Btu/hr ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 4 of11
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[Foil' ❑ Unheated ❑ Unheated ❑Does Not table for values.
0 ❑ Heated ❑ Heated [Not Observable
❑Not Applicable
402.1.2 Slab edge insulation ft ft EComplies I See the Envelope Assemblies
[F03]' depth/length. ❑Does Not table for values.
a ['Not Observable
❑Not Applicable
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[F04]' insulation R-value.Where interior R- R- ❑Does Not table for values.
40 insulation is used, verification ['Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies Requirement will be met.
[F05]' insulation installed per ❑Does Not
manufacturer's instructions.
[Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
1[F06]' insulation depth of burial or El Does Not table for values.
distance from top of wall.
['Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies Requirement will be met.
[F011]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ['Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies Requirement will be met.
[FO controls installed. ❑Does Not
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 5 ofil
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, :Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 , ❑Not Observable
1 ❑Not Applicable
402.1.1, 1 Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). I ❑Does Not table for values.
402.3.3,
402.3.6,
[Not Observable
402.5 : ❑Not Applicable
[FR2]1
303.1.3 1U-factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
fii, with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 ;Air barrier and thermal barrier ❑Complies Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
fii, ,instructions.
❑Not Observable
; ❑Not Applicable
402.4.3 ;Fenestration that is not site built ❑Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits. _
402.4.5 :IC-rated recessed lighting fixtures ❑Complies Requirement will be met.
[FR16]2 sealed at housing/interior finish ❑Does Not
;and labeled to indicate <_2.0 cfm
;leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct is ❑Does Not
Ca >= 3 inches in diameter and >_
R-6 where < 3 inches. Supply and [Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met.
[FR17] above 105 °F or chilled fluids ❑Does Not
below 55 °F are insulated to >_R-
3 ❑Not Observable
❑Not Applicable
403.4.1 :Protection insulation on HVAC I❑Complies Requirement will be met.
[FR24]1 piping. ❑Does Not
fi ❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ElComplies Requirement will be met.
[FR18]2 >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6Automatic or gravity dampers are ❑Complies Requirement will be met.
[FR19] installed on all outdoor air ❑Does Not
intakes and exhausts.
[Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 6 ofll
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 7 ofll
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 ;All installed insulation is labeled '❑Complies Requirement will be met.
[IN13]2 :or the installed R-values ❑Does Not
✓ :provided.
IP [Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel [Not Observable
O I ENot Applicable
303.2, Floor insulation installed per ❑Complies Requirement will be met.
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
underside of the subfloor, or floor ['Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10).
111 Steel 111 Steel ❑Not Applicable
303.2 Wall insulation is installed per 1 ❑Complies Requirement will be met.
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 8 ofll
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood EDoes Not table for values.
402.2.2, ❑ Steel ❑ Steel [Not Observable
402.2.6
[FI1]1 ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. [Not Observable
❑Not Applicable
402.2.3 :Vented attics with air permeable EComplies Requirement will be met.
[F122]2 insulation include baffle adjacent ElDoes Not
to soffit and eave vents that
;extends over insulation. [Not Observable
' ❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[F13]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
[Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
[Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies Exception: Requirement is
[F14]1 cfm/100 ft2 across the system or ft2 ft2 ElDoes Not not applicable.
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ['Not Observable
tests,verification may need to ENot Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 EComplies Exception: Requirement is
[F127]1 determine air leakage with ft2 ft2 ❑Does Not not applicable.
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ENot Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met.
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
[Not Observable
❑Not Applicable
403.1.1 :Programmable thermostats EComplies Requirement will be met.
[F19]2 installed for control of primary ❑Does Not
;heating and cooling systems and
:initially set by manufacturer to ['Not Observable
:code specifications. 1 , ,ENot Applicable
403.1.2 'Heat pump thermostat installed ❑Complies Requirement will be met.
[F110]2 ion heat pumps. ElDoes Not
ENot Observable
ElNot Applicable
403.5.1 Circulating service hot water qElComPlies Requirement will be met.
[F111]2 systems have automatic or ElDoes Not
accessible manual controls.
['Not Observable
ENot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 9 ofll
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 ;All mechanical ventilation system '❑Complies Requirement will be met.
[F125]2 fans not part of tested and listed ❑Does Not
ail
HVAC equipment meet efficacy
and air flow limits. [Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies Requirement will be met.
[F126]2 through one-or two-pipe heating ❑Does Not
441 systems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 :Heated water circulation systems ❑Complies Requirement will be met.
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply [Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
iii'occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 ;Electric heat trace systems ❑Complies Requirement will be met.
[F129]2 comply with IEEE 515.1 or UL EDoes Not
ill515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the ,
piping.
403.5.2 Water distribution systems that ;❑Complies Exception: Requirement is
[F130]2 have recirculation pumps that ElDoes Not not applicable.
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403
.5.4 Drain water heat recovery units 1 ❑Complies Exception: Requirement is
[F13tested tested in accordance with CSA ❑Does Not not applicable.
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ;❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
:individual units connected to
:three or more showers.
i
404.1 '75%of lamps in permanent ❑Complies Requirement will be met.
[F16]' fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage [Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies Exception: Requirement is
[F123]3 no continuous pilot light. ❑Does Not not applicable.
[Not Observable
, ❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 10 ofll
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 ;Compliance certificate posted. '❑Complies Requirement will be met.
[F17F ❑Does Not
[Not Observable
❑Not Applicable
303.3 'Manufacturer manuals for ❑Complies Requirement will be met.
[F118P mechanical and water heating ❑Does Not
systems have been provided. •
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Davos Trail Residence Report date: 11/10/17
Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 11 of11
ci. 2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 31.00
Below-Grade Wall 23.00
Floor 47.00
Ceiling / Roof 57.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.29
Door 0.08
Heating&Cooling Equipment Efficiency
Gas-Fired Steam 95 AFUE
Air Source 7.7 HSPF,
Water Heater: