HomeMy WebLinkAboutB16-0209_B16-0209 - ResCheck Compliance Certificate_1512688150.pdf rREScheck Software Version 4.6.2 ' nh Compliance Certificate Project Davos Trail Residence Energy Code: 2015 IECC Location: Vail, Colorado Construction Type: Single-family Project Type: Alteration Climate Zone: 6 (9248 HDD) Permit Date: Permit Number: B16-0209 Construction Site: Owner/Agent: Designer/Contractor: 2636 Davos Trail Randy Fischer Randy Fischer Vail, CO 81657 2695 Davos Trail Division Six Construction Vail, CO 81657 2695 Davos Trail 970-306-3030 Vail, CO 81657 randy@divisionsixconst.com 970-306-3030 randy@divisionsixconst.com Compliance: Passes using prescriptive requirements for alteration projects Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Flat Roof- 2x12: Flat Ceiling or Scissor Truss 255 57.0 0.0 0.024 6 Sloped Roof Entry- 2x10: Cathedral Ceiling 125 49.0 0.0 0.022 3 Sloped Roof- 14"TJI: Cathedral Ceiling 1,043 57.0 0.0 0.019 20 Flat Roof- 2x12: Flat Ceiling or Scissor Truss 210 57.0 0.0 0.024 5 Sloped Roof- Kitchen 2x12: Cathedral Ceiling 218 60.0 0.0 0.018 4 South Elevation: Wood Frame, 16" o.c. 1,071 23.0 7.0 0.038 34 South Elevation -Windows- U.29: Wood Frame:Double Pane with Low-E 112 0.290 32 South Elevation Windows- U.30: Wood Frame:Double Pane with Low-E 12 0.300 4 South Elevation Windows- U.33: Wood Frame:Double Pane with Low-E 16 0.330 5 South Elevation Windows- U.35: Wood Frame:Double Pane with Low-E 21 0.350 7 South Elevation - Doors (Glass): Glass 21 0.290 6 East Elevation: Wood Frame, 16" o.c. 1,107 24.0 7.0 0.037 29 East Elevation-Windows- U.25: Wood Frame:Double Pane with Low-E 9 0.250 2 East Elevation-Windows- U.26: Wood Frame:Double Pane with Low-E 66 0.260 17 East Elevation-Windows- U.27: Wood Frame:Double Pane with Low-E 24 0.270 6 East Elevation-Windows- U.28: Wood Frame:Double Pane with Low-E 9 0.280 3 East Elevation-Windows- U.29: Wood Frame:Double Pane with Low-E 68 0.290 20 Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 1 of11 Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter East Elevation-Windows- U.30: Wood Frame:Double Pane with Low-E 56 0.300 17 East Elevation-Windows- U.31: Wood Frame:Double Pane with Low-E 14 0.310 4 East Elevation-Windows- U.33: Wood Frame:Double Pane with Low-E 34 0.330 11 East Elevation-Windows- U.35: Wood Frame:Double Pane with Low-E 27 0.350 9 East Elevation- Door(Glass): Glass 20 0.290 6 North East Elevation: Wood Frame, 16" o.c. 1,169 24.0 7.0 0.037 37 North East Elevation -Windows- U.25: Wood Frame:Double Pane with Low-E 19 0.250 5 North East Elevation -Windows- U.26: Wood Frame:Double Pane with Low-E 12 0.260 3 North East Elevation -Windows- U.28: Wood Frame:Double Pane with Low-E 18 0.280 5 North East Elevation -Windows- U.33: Wood Frame:Double Pane with Low-E 20 0.330 7 North East Elevation - Doors: Glass 90 0.290 26 West Elevation: Wood Frame, 16" o.c. 546 24.0 7.0 0.037 15 West Elevation-Windows- U.27: Wood Frame:Double Pane with Low-E 5 0.270 1 West Elevation-Windows- U.29: Wood Frame:Double Pane with Low-E 60 0.290 17 West Elevation-Windows- U.33: Wood Frame:Double Pane with Low-E 40 0.330 13 West Elevation- Doors- U.29- Entry: Glass 13 0.290 4 West Elevation- Doors- U.33 - Elevator: Glass 15 0.330 5 South West Elevation (Garage/Front): Wood Frame, 16" o.c. 430 24.0 7.0 0.037 8 South West Elevation -Windows- U.31: Wood Frame:Double Pane with Low-E 9 0.310 3 South West Elevation -Windows- U.33: Wood Frame:Double Pane with Low-E 8 0.330 3 South West Elevation - Doors- U.33: Glass 14 0.330 5 South West Elevation -Garage Doors: Solid 150 0.080 12 South West Elevation - Doors- U.29: Glass 44 0.290 13 North West Elevation (Garage/Side): Wood Frame, 16" o.c. 330 24.0 7.0 0.037 11 North West Elevation -Windows- U: Wood Frame:Double Pane with Low-E 12 0.330 4 North West Elevation - Doors: Glass 12 0.290 3 South East Elevation (Garage/Side): Wood Frame, 16" o.c. 206 24.0 7.0 0.037 8 :Lower Level Existing SOG - Exposed Edge: Slab-On-Grade:Unheated 78 10.0 0.684 53 Insulation depth: 4.0' Main Level SOG - Exposed Edge: Slab-On-Grade:Heated 16 15.0 0.655 10 Insulation depth: 4.0' Main Level -Overhangs: All-Wood Joist/Truss:Over Outside Air 203 40.0 7.0 0.021 4 Basement Wall (50% below Grade): Solid Concrete or Masonry 915 13.0 10.0 0.036 33 Wall height: 7.5' Depth below grade: 7.0' Insulation depth: 7.5' Mechanical Equipment Description Fuel type Efficiency Gas-Fired Steam Gas 95 AFUE Air Source Electric 7.7 HSPF, 13 SEER Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 2 of11 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 3 of11 RInspectionEScheck Software VersionChecklist 4.6.2 Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and Complies Requirement will be met. 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the V, building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ['Not Observable Systems serving multiple ENot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr EDoes Not [PR2]2 on loads calculated per ACOA Cooling: Cooling: Manual J or other methods ['Not Observable approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 4 of11 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [Foil' ❑ Unheated ❑ Unheated ❑Does Not table for values. 0 ❑ Heated ❑ Heated [Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft EComplies I See the Envelope Assemblies [F03]' depth/length. ❑Does Not table for values. a ['Not Observable ❑Not Applicable 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]' insulation R-value.Where interior R- R- ❑Does Not table for values. 40 insulation is used, verification ['Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies Requirement will be met. [F05]' insulation installed per ❑Does Not manufacturer's instructions. [Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies 1[F06]' insulation depth of burial or El Does Not table for values. distance from top of wall. ['Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies Requirement will be met. [F011]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ['Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Requirement will be met. [FO controls installed. ❑Does Not ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 5 ofil Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, :Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 , ❑Not Observable 1 ❑Not Applicable 402.1.1, 1 Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). I ❑Does Not table for values. 402.3.3, 402.3.6, [Not Observable 402.5 : ❑Not Applicable [FR2]1 303.1.3 1U-factors of fenestration products ❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not fii, with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not fii, ,instructions. ❑Not Observable ; ❑Not Applicable 402.4.3 ;Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. _ 402.4.5 :IC-rated recessed lighting fixtures ❑Complies Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not ;and labeled to indicate <_2.0 cfm ;leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies Requirement will be met. [FR12]1 insulated >= R-8 where duct is ❑Does Not Ca >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and [Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met. [FR17] above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 :Protection insulation on HVAC I❑Complies Requirement will be met. [FR24]1 piping. ❑Does Not fi ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ElComplies Requirement will be met. [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19] installed on all outdoor air ❑Does Not intakes and exhausts. [Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 6 ofll Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 7 ofll Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ;All installed insulation is labeled '❑Complies Requirement will be met. [IN13]2 :or the installed R-values ❑Does Not ✓ :provided. IP [Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel [Not Observable O I ENot Applicable 303.2, Floor insulation installed per ❑Complies Requirement will be met. 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, or floor ['Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). 111 Steel 111 Steel ❑Not Applicable 303.2 Wall insulation is installed per 1 ❑Complies Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 8 ofll Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood EDoes Not table for values. 402.2.2, ❑ Steel ❑ Steel [Not Observable 402.2.6 [FI1]1 ENot Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. [Not Observable ❑Not Applicable 402.2.3 :Vented attics with air permeable EComplies Requirement will be met. [F122]2 insulation include baffle adjacent ElDoes Not to soffit and eave vents that ;extends over insulation. [Not Observable ' ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. [Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. [Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies Exception: Requirement is [F14]1 cfm/100 ft2 across the system or ft2 ft2 ElDoes Not not applicable. <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ['Not Observable tests,verification may need to ENot Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 EComplies Exception: Requirement is [F127]1 determine air leakage with ft2 ft2 ❑Does Not not applicable. either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ENot Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. [Not Observable ❑Not Applicable 403.1.1 :Programmable thermostats EComplies Requirement will be met. [F19]2 installed for control of primary ❑Does Not ;heating and cooling systems and :initially set by manufacturer to ['Not Observable :code specifications. 1 , ,ENot Applicable 403.1.2 'Heat pump thermostat installed ❑Complies Requirement will be met. [F110]2 ion heat pumps. ElDoes Not ENot Observable ElNot Applicable 403.5.1 Circulating service hot water qElComPlies Requirement will be met. [F111]2 systems have automatic or ElDoes Not accessible manual controls. ['Not Observable ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 9 ofll Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 ;All mechanical ventilation system '❑Complies Requirement will be met. [F125]2 fans not part of tested and listed ❑Does Not ail HVAC equipment meet efficacy and air flow limits. [Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies Requirement will be met. [F126]2 through one-or two-pipe heating ❑Does Not 441 systems have outdoor setback control to lower boiler water [Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 :Heated water circulation systems ❑Complies Requirement will be met. [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply [Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the iii'occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 ;Electric heat trace systems ❑Complies Requirement will be met. [F129]2 comply with IEEE 515.1 or UL EDoes Not ill515. Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the , piping. 403.5.2 Water distribution systems that ;❑Complies Exception: Requirement is [F130]2 have recirculation pumps that ElDoes Not not applicable. pump water from a heated water supply pipe back to the heated ['Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403 .5.4 Drain water heat recovery units 1 ❑Complies Exception: Requirement is [F13tested tested in accordance with CSA ❑Does Not not applicable. B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ;❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for :individual units connected to :three or more showers. i 404.1 '75%of lamps in permanent ❑Complies Requirement will be met. [F16]' fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage [Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies Exception: Requirement is [F123]3 no continuous pilot light. ❑Does Not not applicable. [Not Observable , ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 10 ofll Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 ;Compliance certificate posted. '❑Complies Requirement will be met. [F17F ❑Does Not [Not Observable ❑Not Applicable 303.3 'Manufacturer manuals for ❑Complies Requirement will be met. [F118P mechanical and water heating ❑Does Not systems have been provided. • [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Davos Trail Residence Report date: 11/10/17 Data filename: C:\Users\user\Documents\Ondra\Work\DAVOS\06 - ResCheck\2636 Davos Trail.rck Page 11 of11 ci. 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 31.00 Below-Grade Wall 23.00 Floor 47.00 Ceiling / Roof 57.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.08 Heating&Cooling Equipment Efficiency Gas-Fired Steam 95 AFUE Air Source 7.7 HSPF, Water Heater: Name: Date: Comments