HomeMy WebLinkAboutLoad Calcs_30.pdfDouble M Inc P.O. Box 1462 Gypsum, CO 81637 (970) 376-4862 Date: 5-26-16 Residential Electrical Load Calculations Owner: Fischer Residence Address: 2636 Davos Trail General Lighting Load Square footage: 4100 General lighting load: Small appliance: Laundry Circuit: Lighting Load Subtotal: First 3000@ 100%: 3001 watts to 120,000 watts@ 35%: Over 120,000 watts@ 25%: Lighting Load Total: Cooking Equipment Loads Range: Load@ 100% Dryer load Dryer: Load@ 100% 12300 Watts 3000 Watts 3000 Watts 18300 Watts 3000 Watts 5355 Watts Watts 8355 Watts 10400 Watts 5000 Watts Fixed Appliance Load Dishwasher: Disposal: Elevator: Microwave: Range Hood: Refrigerator: Jacuzzi Tub: Spa: Freezer: Compressor: Car charger: Garage Door: Total: 1050 Watts 600 Watts 7200 Watts 1500 Watts 360 Watts 1920 Watts 1500 Watts 9600 Watts 720 Watts 4800 Watts 9600 Watts 720 Watts 39570 Watts Less than 4 appliance at 100%: More than 4 appliances at 75%: Watts 29677.5 Watts Total: Heating or A/C load which ever is larger Heating unit: A/C unit: Heat tape: Largest load: Largest Motor Load 1440 Watts Watts 5000 Watts 6440 Load @ 100% 4800 Watts @ 25%: Total load: Total amp draw: Service Size: 29677.5 Watts 6440 Watts 1200 Watts 61072.5 Watts 254.46875 Amps 400 Amps