HomeMy WebLinkAbout1414 Moraine Drive - Air Infiltration Testing Report.pdf NORTPENFRGY formerly ACTIVE ENERGIES_ 1414 Moraine Drive Air Infiltration Report Test Date: February 14, 2018 Builder: Gillette Construction, LLC Contact: Brian Gillette Site Address: 1414 Moraine Drive, Vail, CO Site Visit By: Jason Weingast Background The project goal is to undergo testing at the final point in construction to determine if the home meets the 2015 IECC requirements for infiltration. Active Energies was contracted to perform a final blower door test to determine total air infiltration. The home is permitted under The Town of Vail and requires blower door testing per the IECC. The blower door testing must show a tested value of 3 ACH50 or lower in order to comply with the IECC. Site Observations Construction of the building envelope was complete. All exterior openings were shut and locked and interior doors were open. The blower door test was performed in the lower guest exterior door to the home. The pressure probe was placed outside. Blower Door Test The unit was depressurized, utilizing blower door testing equipment to a pressure of-50 Pa. At the test pressure, the CFM50 was recorded, in order to determine the ACH5o. The blower door air leakage resulted in the following measurements: 1.3ACH5o Please call with any questions or concerns. \°64 ‘ Jason Weingast LEED for Homes Green Rater,HERS Rater NORTH 39 ENERGY/Active Energies, Inc. Expert Energy Consulting, Training &Verification Services Page 1 of 1 2/16/2018 P.O.Box 1434,Edwards,CO 81632 P: 970.306.4237