Loading...
HomeMy WebLinkAboutB16-0266_A001_1478902337.pdfE C WINDOW TYPE (ALPHABETIC) REVISION (NUMERIC) COLUMN LINE WORK OR DATUM POINT C 9'-0" A.F.F. CEILING TYPE / FINISH CEILING HEIGHT F FLOOR FINISH B BASE FINISH W WALL FINISH DOOR NUMBER 123A ROOMNAME A123 ROOM NUMBER BUILDING PORTION (WHEN USED) A4a PARTITION TYPE 1A A101 SIM DRAWING WHERE SHOWN SECTION CALL-OUT A101 2A 3B 3A 2B ELEVATION CALL-OUT DRAWING WHERE SHOWN 1A A101 DETAIL CALL-OUT DRAWING WHERE SHOWN 1.01 KEYNOTE T TRIM FINISH FURNITURE TYPE 204 306 INTERIOR FINISH INDEX E.8 OR EXISTING PARTITION EXISTING PARTITION TO BE DEMOLISHED NOTE: REFER TO LIFE SAFETY DRAWING(S) FOR RATED PARTITION INDICATIONS NEW PARTITION CONCRETE MASONRY (CMU) CONCRETE PRECAST CONCRETE BRICK STONE STEEL ALUMINUM POROUS FILL SOIL RIGID INSULATION BATT INSULATION GYPSUM DRYWALL PLASTER OR SAND PLYWOOD FRAMING LUMBER FINISH WOOD CERAMIC TILE ACOUSTICAL PANELS LIGHTWEIGHT CONC. TOPPING 2'x2' LIGHT FIXTURE 2'x4' LIGHT FIXTURE RECESSED CAN LIGHT FIXTURE EXIT SIGN PENDANT LIGHT FIXTURE EXHAUST FAN RETURN REGISTER SUPPLY DIFFUSER SECURITY CAMERA FLUSH MOUNTED PA SPEAKER SUSPENDED CEILING SYSTEM STRIP FLUORESCENT LIGHT FIXTURE EMERGENCY WALL MOUNTED LIGHT FIXTURE WITH BATTERY BACKUP - REFER TO ELEC. WALL MOUNTED LIGHT FIXTURE SPRINKLER DIRECTION OF SLOPE IN STRUCTURE DIRECTION OF SLOPE IN INSULATION DIRECTION OF SLOPE IN CRICKET WALK PAD SHEET SEQUENCE VIEW TYPE MODIFIER 0 = DEMOLITION PLANS (OPTIONAL) 1 = FLOOR PLANS 2 = REFELECTED CEILING PLANS 3 = FINISH PLANS 4 = FF&E PLANS VIEW TYPE 0 = GENERAL / SCHEDULES 1 = PLANS 2 = EXTERIOR ELEVATIONS & DETAILS 3 = OVERALL BUILDING & EXTERIOR WALL SECTIONS 4 = ENLARGED PLANS 5 = INTERIOR ELEVATIONS & CASEWORK 6 = DETAILS DISCIPLINE T = TITLE SHEET & INDEX G = GENERAL B = GEOTECHNICAL / ENVIRONMENTAL D = DEMOLITION SERIES C = CIVIL L = LANDSCAPE A = ARCHITECTURAL / INTERIORS I = INTERIORS S = STRUCTURAL F = FIRE PROTECTION P = PLUMBING M = MECHANICAL / HVAC E = ELECTRICAL X = OTHER 30" SITTING HEIGHT 34" ADA HEIGHT 36" STANDING HEIGHT 42" TRANSACTION HEIGHT 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2014 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 8/29/2016 4:05:50 PM GENERAL DRAWING STANDARDS & NOTES THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOTES - GENERAL 1. VERIFY ALL EXISTING CONDITIONS. 2. CONTRACTOR TO MAINTAIN EGRESS ROUTES FROM EXISTING BUILDING THROUGHOUT COURSE OF CONSTRUCTION. 3. VERTICAL DIMENSIONS ARE FROM "FLOOR LINE" UNLESS OTHERWISE NOTED. REFER TO ELEVATIONS FOR "FLOOR LINE" DATUMS. 4. HORIZONTAL DIMENSIONS FOR NEW CONSTRUCTION ARE FROM FACE OF FINISH UNLESS OTHERWISE NOTED. HORIZONTAL DIMENSIONS FOR EXISTING CONSTRUCTION ARE FROM FACE OF EXISTING FINISHED SURFACE. 5. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT WITH THE DESIGN PROFESSIONAL TO OBTAIN CLARIFICATION BEFORE CONTINUING WITH CONSTRUCTION. 6. HOLES CUT THROUGH EXISTING OR NEW FIRE RATED CONSTRUCTION FOR INSTALLATION OF PIPING, DUCTWORK, OR OTHER PENETRATIONS SHALL BE KEPT TO A MINIMUM NUMBER AND HELD TO A MINIMUM SIZE. FILL VOIDS BETWEEN PIPES, DUCTS, OTHER PENETRATING ITEMS AND RATED CONSTRUCTION WITH FIRE RETARDANT SEALANT SYSTEM LISTED IN THE UL FIRE RESISTANCE DIRECTORY WITH FIRE (F) AND TEMPERATURE (T) RATINGS EQUAL TO OR GREATER THAN THE FIRE RESISTANCE RATING OF THE ASSEMBLY BEING SEALED. 7. ALIGN NEW FLOOR FINISHES WITH EXISTING ADJACENT FLOOR FINISHES UNLESS OTHERWISE INDICATED WHERE NEW AND EXISTING FINISHED SURFACES ARE INDICATED TO BE ALIGNED, INSTALL SO FINISHED SURFACES ARE FLUSH (FEATHER MAXIMUM 1/8” PER FOUR FEET). 8. IT IS UNDERSTOOD AND AGREED THAT DRAWING REFINEMENTS, ADDITIONAL DETAILING AND CLARIFICATIONS WILL BE ISSUED DURING THE CONSTRUCTION SCHEDULE AND NO ADJUSTMENT WILL BE MADE IN THE CONTRACTORS’ OR SUB-CONTRACTORS’ PRICE UNLESS SUCH REFINEMENT, DETAILING OR CLARIFICATIONS RESULT IN CHANGES TO THE SCOPE, QUALITY, FUNCTION AND OR INTENT OF THE DRAWINGS AND THE PROJECT MANUAL NOT REASONABLY INFERABLE BY A CONTRACTOR OR SUB-CONTRACTOR EXPERIENCED IN THIS TYPE OF WORK. 9. ALL CONTRACTORS AND SUB-CONTRACTORS MUST QUOTE ON COMPLETED, FULLY OPERABLE SYSTEMS BASED ON THE DESIGN INTENT OF THE CONTRACT DOCUMENTS, AND ALL MATERIAL AND LABOR IMPLIED THEREFROM. 10. UNLESS OTHERWISE REQUIRED BY THE OWNER, CONSTRUCTION ADMINISTRATION SERVICES WILL BE COMPLETED USING NEWFORMA PROJECT CENTER. REFERENCE DIVISION 1 OF THE SPECIFICATION FOR THE PROCEDURES FOR REQUESTS FOR INFORMATION AND SUBMITTALS. LEGEND - GENERAL SYMBOLS LEGEND - PARTITION INDICATIONS LEGEND - MATERIAL INDICATIONS LEGEND - REFLECTED CEILING DEFINITION: THE TERM "DESIGN PROFESSIONAL" MEANS "ARCHITECT", "PROFESSIONAL ENGINEER", "INTERIOR DESIGNER" OR OTHER PARTY RESPONSIBLE FOR PROVIDING DESIGN SERVICES AS APPROPRIATE. 1. THE REFLECTED CEILING PLAN PROVIDES INFORMATION CONCERNING THE LOCATIONS OF LIGHTS, CEILING FIXTURES, HVAC GRILLES, ETC. REFER TO THE REFLECTED CEILING PLAN FOR LOCATIONS ONLY. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR APPLICABLE ENGINEERING INFORMATION. 2. SPRINKLER HEADS ARE NOT INDICATED. REFER TO PLUMBING DRAWINGS FOR SPRINKLER REQUIREMENTS AND INFORMATION. 3. CEILING FIXTURES INCLUDING GRILLES, DIFFUSERS, INCANDESCENT LIGHTS, ETC. ARE TO BE CENTERED IN ACOUSTIC CEILING PANELS UNLESS NOTED OTHERWISE. 4. ALL CEILING HEIGHTS NOTED ARE ABOVE FINISHED FLOOR (A.F.F.) NOTES - REFLECTED CEILING PLAN LEGEND - ROOF NOTES - TOBACCO FREE WORKZONE USE OF TOBACCO PRODUCTS IS NOT PERMITTED ANYWHERE ON OWNER'S PROPERTY. PROHIBIT USE OF ALL TOBACCO PRODUCTS, INCLUDING BUT NOT LIMITED TO CIGARETTES, CIGARS, PIPES, CHEWING TOBACCO, SNUFF, DIP, SNUS AND ELECTRONIC CIGARETTES BY ALL PERSONNEL COVERED BY THIS CONTRACT WHILE ON OWNER'S PROPERTY. THIS PROHIBITION APPLIES TO OCCUPANTS OF JOBSITE OFFICES, STORAGE OR WORK SHEDS, WORK AREAS ASSIGNED EXCLUSIVELY TO THE CONTRACTOR, AND VEHICLES WHILE THE VEHICLE IS ON OWNER'S PROPERTY. ENFORCE REQUIREMENTS STRICTLY. LVR LOUVER MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MLD MOLDING mm MILLIMETER MO MASONRY OPENING MT METAL THRESHOLD MTL METAL MULL MULLION MWK MILLWORK N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OFF OFFICE OFOI OWNER FURNISHED OWNER INSTALLED OH OVERHEAD OPNG OPENING OPP OPPOSITE OPP H OPPOSITE HAND OVFL OVERFLOW #LBS POUNDS PAR PARALLEL PART PARTIAL PARTN PARTITION PERIM PERIMETER PERP PERPENDICULAR PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER, PLASTIC PLBG PLUMBING PLWD PLYWOOD PNL PANEL PNT PAINT PP PITCH POCKET PR PAIR PRV POWERED ROOF VENTILATOR PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED, PORCELAIN TILE PWC PLASTIC WALL COVERING QT QUARRY TILE QTY QUANTITY QUAL QUALITY R RISER RA RETURN AIR RAD RADIUS RB RUBBER, RUBBER BASE RD ROOF DRAIN REBAR REINFORCING BAR RECEP RECEPTACLE, RECEPTION REF REFERENCE REFL REFLECTED REFR REFRIGERATOR REG REGULAR REINF REINFORCED REP REPAIR REQ REQUIRE, REQUIRED RESIL RESILIENT REV REVISION RFG ROOFING RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING RT RIGHT S SOUTH SC SOLID CORE SCHED SCHEDULE SCUP SCUPPER SD SOAP DISPENSER SECT SECTION SHT SHEET SHWR SHOWER SIM SIMILAR SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SP STAND PIPE SPEC SPECIFICATION SPM SINGLE PLY MEMBRANE SS SERVICE SINK, STAINLESS STEEL SSM SOLID SURFACE MATERIAL ST STAINLESS STL STEEL STN STONE STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL SYS SYSTEM T TREAD T GL TEMPERED GLASS T&G TONGUE & GROOVE TB TOWEL BAR TD TRENCH DRAIN TEL TELEPHONE TEMP TEMPERED, TEMPORARY TERR TERRAZZO THK THICK TLT TOILET TOC TOP OF CURB, TOP OF CONCRETE TOM TOP OF MASONRY TOS TOP OF STEEL TOSL TOP OF SLAB TTD TOILET TISSUE DISPENSER TWS THRU-WALL SCUPPER TYP TYPICAL UC UNDERCOUNTER, UNDERCUT UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE VB VAPOR BARRIER, VINYL BASE VC VALVE CABINET VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL VIT VITREOUS CHINA VNR VENEER VP VENT PIPE, VAPOR PROOF VTR VENT THRU ROOF VWC VINYL WALL COVERING W WIDTH W/ WITH W/O WITHOUT WAINS WAINSCOT WB WOOD BASE WC WALL COVERING, WATER CLOSET WD WOOD WG WIRE GLASS WH WATER HEATER WIN WINDOW WPR WATERPROOFING WPT WORK POINT WR WATER RESISTANT, WASTE RECEPTACLE WT WEIGHT WWF WELDED WIRE FABRIC @ AT A/C AIR CONDITIONING AB ANCHOR BOLT AC ACOUSTICAL ACP ACOUSTICAL CEILING PANEL AD ACCESS DOOR ADJ ADJACENT, ADJUSTABLE AFF ABOVE FINISHED FLOOR AL ALUMINUM ALT ALTERNATE AP ARMOR PLATE APPROX APPROXIMATE ARCH ARCHITECTURAL AWC ACOUSTICAL WALL COVERING BC BRICK COURSES(ING) BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BENCH MARK, BEAM BOT BOTTOM BRG BEARING BRK BRICK BSMT BASEMENT BUR BUILT UP ROOFING CB CATCH BASIN CF CUBIC FOOT (FEET) CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFM CUBIC FOOT PER MINUTE CG CORNER GUARD CHAN CHANNEL CHR CHAIR RAIL CI CAST IRON CIP CAST IN PLACE CJ CONTROL JOINT CLG CEILING CLO CLOSET CLR CLEAR cm CENTIMETER CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN COMP COMPOSITION, COMPOSITE CONC CONCRETE CONT CONTINUOUS CORR CORRIDOR CP CLEAR PLASTIC CPT CARPET CR CRASH RAIL CR/BG CRASH RAIL / BUMPER GUARD CT CERAMIC TILE CTR CENTER CV CHECK VALVE CW CLEAR WIRE GLASS CY CUBIC YARD CYL CYLINDER Ѥ CENTERLINE D DEPTH DBL DOUBLE DEG DEGREE DEMO DEMOLITION DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DP DAMPROOFING DR DOOR, DRAIN DS DOWNSPOUT DWG DRAWING DWGS DRAWINGS EA EACH EB EXPANSION BOLT EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATOR, ELEVATION EMER EMERGENCY ENGR ENGINEER(ING) EPDM ETHYLENE PROPYLENE DIENE MONOMER (ROOF MEMBRANE) EQ EQUAL EQUIP EQUIPMENT ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EXIST EXISTING EXPA EXPANSION ANCHOR EXT EXTERIOR F FAHRENHEIT FA FIRE ALARM FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FHC FIRE HOSE CABINET FIN FINISH(ED) FO FINISHED OPENING FOF FACE OF FINISH FOS FACE OF STUD FRTW FIRE RETARDANT TREATED WOOD FV FIELD VERIFIED FWC FABRIC WALL COVERING GA GAGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GEN GENERAL GL GLASS, GLAZING GND GROUND GNV GOOSE NECK VENTILATOR GR GROUT GYP GYPSUM GYP BD GYPSUM BOARD H HIGH HB HOSE BIBB HC HOLLOW CORE HD HEAVY DUTY HDW HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HRL HANDRAIL HVAC HEATING VENTILATING & AIR CONDITIONING HWD HARDWOOD ID INSIDE DIAMETER IN INCH INSUL INSULATION INT INTERIOR IPT INTERIOR PAINT JAN JANITOR JCT JUNCTION JST JOIST JT JOINT JT B JOINT BACKER KB KEYBOARD KIT KITCHEN KO KNOCKOUT KP KICK PLATE KS KNEE SPACE L LENGTH LAM LAMINATE, LAMINATED LAM GL LAMINATED GLASS LAV LAVATORY LB POUND LBF POUNDS-FORCE LH LEFT HAND LIN LINEAR LLV LONG LEG VERTICAL LEGEND - ABBREVIATIONS 1. CONTRACTOR TO CONTACT OWNER PRIOR TO START OF DEMOLITION OF ANY AREAS TO ALLOW OWNER TO REMOVE ANY MOVABLE EQUIPMENT SO DESIRED. 2. REMOVE ALL FIRE EXTINGUISHERS AND CABINETS IN WALLS TO BE DEMOLISHED AND RETURN TO OWNER FOR FURTURE REUSE. 3. REPAIR HOLES IN EXISTING WALLS TO REMAIN WHERE WALL MOUNTED ITEMS ARE TO BE REMOVED. REFER TO ROOM FINISH LEGEND FOR FINAL FINISH. 4. PATCH, FILL, AND LEVEL ALL HOLES IN FLOOR SLAB DUE TO DEMOLITION OF PLUMBING RISERS, FLOOR DRAINS, ELECTRICAL RISERS, MILLWORK, CASEWORK, OR EQUIPMENT. 5. REPAIR ALL CEILINGS TO MATCH EXISTING CEILINGS WHERE WALLS ARE TO BE DEMOLISHED AND EXISTING CEILING IS TO REMAIN. 6. CONTRACTOR TO MATCH ALL EXISTING CONDITIONS FOR ALL REQUIRED MODIFICATIONS IN RENOVATED AREAS (U.N.O.). THIS REFERS TO REPETITIONS OF FINISH PATTERNS AND COLORS, MODIFICATIONS TO HANDRAILS AND BUMPER PANELS, ETC. 7. WHERE PARTITIONS, EQUIPMENT, OR ACCESSORIES, ETC. ARE REMOVED AND NO REPLACEMENT FINISH IS CALLED FOR, THE GENERAL CONTRACTOR SHALL REPAIR TO MATCH ADJACENT FINISH. 8. CONTRACTOR TO PROTECT FROM DAMAGE ALL EXISTING FLOORS, WALLS, CEILINGS, ETC. DURING CONSTRUCTION AND PROVIDE TEMPORARY PARTITIONS AS NEEDED. CONTRACTOR IS RESPONSIBILE FOR REPAIR AND REPLACEMENT OF ALL DAMAGED FLOORING, WALLS, CEILINGS, ETC. FINISHES TO MATCH EXISTING. 9. DASHED LINES INDICATE EXISTING CONSTRUCTION TO BE DEMOLISHED. TYPICAL (U.N.O.) 10. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL DEMOLITION MATERIALS. TEMPORARY LIGHTING WILL BE PROVIDED BY THE CONTRACTOR. 11. REMOVE ALL FLOOR COVERINGS AND PREP CONCRETE DECK FOR NEW CARPET, VINYL AND CERAMIC TILE AS SCHEDULED. (TYPICAL - ALL ROOMS WITHIN LIMITS OF PROJECT) 12. REMOVE EXISTING CEILING GRID AND ASSOCIATED SUPPORT SYSTEM - RETURN EXISTING LIGHT FIXTURES TO OWNER (TYPICAL - ALL ROOMS WITHIN LIMITS OF PROJECT) 13. ADDITIONAL DEMOLITION MAY BE REQUIRED TO ACCOMMODATE NEW CONSTRUCTION SHOWN ON OTHER SHEETS. CONTRACTORS TO REVIEW EXISTING CONDITIONS AND INCLUDE IN BASE BID ALL DEMOLITION REQUIRED FOR A COMPLETE INSTALLATION. 14. REMOVE ALL EXISTING BASES AND VINYL WALL COVERINGS. PREPARE SURFACES TO ACCEPT NEW FINISHES, TYP. NOTES - GENERAL DEMOLITION NOTES - PATCH & REPAIR 1. FILL ALL HOLES IN FLOOR SLAB WITH CONCRETE AFTER REMOVAL OF PLUMBING LINES, DRAINS, PIPES, ETC. MAINTAIN REQUIRED FIRE RATINGS. 2. PATCH AND REPAIR HOLES IN EXISTING GYP BD PARTITIONS FROM REMOVED EQUIPMENT, MECHANICAL AND ELECTRICAL DEVICES AND OUTLETS, ATTACHMENTS, FURNISHINGS, ETC. 3. PATCH AND REPAIR ALL CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW MECHANICAL AND ELECTRICAL WORK. THIS WORK MAY EXTEND BEYOND BOUNDARIES INDICATING "PROJECT LIMITS" ON ARCHITECTURAL DRAWINGS. FINISHES SHALL MATCH EXISTING, OR PROVIDE NEW AS SCHEDULED. 4. PATCH AND REPAIR ALL EXISTING FIREPROOFING DISTURBED DURING DEMOLITION AT COLUMNS AND BRACING TO MEET REQUIRED FIRE RATINGS. 5. PATCH AND REPAIR FINISHES WHERE EXISTING WALLS, PARTITIONS, DOORS, PLUMBING FIXTURES, OR CASEWORK HAVE BEEN REMOVED. FINISHES SHALL MATCH EXISTING, OR PROVIDE NEW AS SCHEDULED. LEGEND - DRAWING NUMBERS LEGEND - TYPICAL COUNTER HEIGHTS 11/03/16