HomeMy WebLinkAboutB16-0266_A001_1491490893.pdfE
C
WINDOW TYPE (ALPHABETIC)
REVISION (NUMERIC)
COLUMN LINE
WORK OR DATUM POINT
C
9'-0" A.F.F.
CEILING TYPE / FINISH
CEILING HEIGHT
F FLOOR FINISH
B BASE FINISH
W WALL FINISH
DOOR NUMBER
123A
ROOMNAME
A123
ROOM NUMBER
BUILDING PORTION (WHEN USED)
A4a PARTITION TYPE
1A
A101
SIM
DRAWING WHERE SHOWN
SECTION CALL-OUT
A101
2A
3B
3A
2B
ELEVATION CALL-OUT
DRAWING WHERE SHOWN
1A
A101
DETAIL CALL-OUT
DRAWING WHERE SHOWN
1.01 KEYNOTE
T TRIM FINISH
FURNITURE TYPE
204
306 INTERIOR FINISH INDEX
E.8
OR
EXISTING PARTITION
EXISTING PARTITION
TO BE DEMOLISHED
NOTE: REFER TO LIFE SAFETY DRAWING(S) FOR RATED PARTITION INDICATIONS
NEW PARTITION
CONCRETE
MASONRY (CMU)
CONCRETE
PRECAST
CONCRETE
BRICK
STONE
STEEL
ALUMINUM
POROUS FILL
SOIL
RIGID INSULATION
BATT INSULATION
GYPSUM DRYWALL
PLASTER OR SAND
PLYWOOD
FRAMING LUMBER
FINISH WOOD
CERAMIC TILE
ACOUSTICAL PANELS
LIGHTWEIGHT
CONC. TOPPING
2'x2' LIGHT FIXTURE
2'x4' LIGHT FIXTURE
RECESSED CAN LIGHT FIXTURE
EXIT SIGN
PENDANT LIGHT FIXTURE
EXHAUST FAN
RETURN REGISTER
SUPPLY DIFFUSER
SECURITY CAMERA
FLUSH MOUNTED PA SPEAKER
SUSPENDED CEILING SYSTEM
STRIP FLUORESCENT LIGHT FIXTURE
EMERGENCY WALL MOUNTED LIGHT FIXTURE
WITH BATTERY BACKUP - REFER TO ELEC.
WALL MOUNTED LIGHT FIXTURE
SPRINKLER
DIRECTION OF SLOPE
IN STRUCTURE
DIRECTION OF SLOPE
IN INSULATION
DIRECTION OF
SLOPE IN CRICKET
WALK PAD
SHEET SEQUENCE
VIEW TYPE MODIFIER
0 = DEMOLITION PLANS
(OPTIONAL)
1 = FLOOR PLANS
2 = REFELECTED CEILING
PLANS
3 = FINISH PLANS
4 = FF&E PLANS
VIEW TYPE
0 = GENERAL / SCHEDULES
1 = PLANS
2 = EXTERIOR ELEVATIONS
& DETAILS
3 = OVERALL BUILDING &
EXTERIOR WALL
SECTIONS
4 = ENLARGED PLANS
5 = INTERIOR ELEVATIONS
& CASEWORK
6 = DETAILS
DISCIPLINE
T = TITLE SHEET & INDEX
G = GENERAL
B = GEOTECHNICAL /
ENVIRONMENTAL
D = DEMOLITION SERIES
C = CIVIL
L = LANDSCAPE
A = ARCHITECTURAL /
INTERIORS
I = INTERIORS
S = STRUCTURAL
F = FIRE PROTECTION
P = PLUMBING
M = MECHANICAL / HVAC
E = ELECTRICAL
X = OTHER
30" SITTING
HEIGHT
34" ADA
HEIGHT
36" STANDING
HEIGHT
42" TRANSACTION
HEIGHT
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
10/12/2016
6:08:01 PM
GENERAL DRAWING
STANDARDS & NOTES
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A001
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
NOTES - GENERAL
1. VERIFY ALL EXISTING CONDITIONS.
2. CONTRACTOR TO MAINTAIN EGRESS ROUTES FROM EXISTING BUILDING
THROUGHOUT COURSE OF CONSTRUCTION.
3. VERTICAL DIMENSIONS ARE FROM "FLOOR LINE" UNLESS OTHERWISE NOTED. REFER
TO ELEVATIONS FOR "FLOOR LINE" DATUMS.
4. HORIZONTAL DIMENSIONS FOR NEW CONSTRUCTION ARE FROM FACE OF FINISH
UNLESS OTHERWISE NOTED. HORIZONTAL DIMENSIONS FOR EXISTING
CONSTRUCTION ARE FROM FACE OF EXISTING FINISHED SURFACE.
5. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT,
CONSULT WITH THE DESIGN PROFESSIONAL TO OBTAIN CLARIFICATION BEFORE
CONTINUING WITH CONSTRUCTION.
6. HOLES CUT THROUGH EXISTING OR NEW FIRE RATED CONSTRUCTION FOR
INSTALLATION OF PIPING, DUCTWORK, OR OTHER PENETRATIONS SHALL BE KEPT TO
A MINIMUM NUMBER AND HELD TO A MINIMUM SIZE. FILL VOIDS BETWEEN PIPES,
DUCTS, OTHER PENETRATING ITEMS AND RATED CONSTRUCTION WITH FIRE
RETARDANT SEALANT SYSTEM LISTED IN THE UL FIRE RESISTANCE DIRECTORY WITH
FIRE (F) AND TEMPERATURE (T) RATINGS EQUAL TO OR GREATER THAN THE FIRE
RESISTANCE RATING OF THE ASSEMBLY BEING SEALED.
7. ALIGN NEW FLOOR FINISHES WITH EXISTING ADJACENT FLOOR FINISHES UNLESS
OTHERWISE INDICATED WHERE NEW AND EXISTING FINISHED SURFACES ARE
INDICATED TO BE ALIGNED, INSTALL SO FINISHED SURFACES ARE FLUSH (FEATHER
MAXIMUM 1/8” PER FOUR FEET).
8. IT IS UNDERSTOOD AND AGREED THAT DRAWING REFINEMENTS, ADDITIONAL
DETAILING AND CLARIFICATIONS WILL BE ISSUED DURING THE CONSTRUCTION
SCHEDULE AND NO ADJUSTMENT WILL BE MADE IN THE CONTRACTORS’ OR
SUB-CONTRACTORS’ PRICE UNLESS SUCH REFINEMENT, DETAILING OR
CLARIFICATIONS RESULT IN CHANGES TO THE SCOPE, QUALITY, FUNCTION AND OR
INTENT OF THE DRAWINGS AND THE PROJECT MANUAL NOT REASONABLY
INFERABLE BY A CONTRACTOR OR SUB-CONTRACTOR EXPERIENCED IN THIS TYPE
OF WORK.
9. ALL CONTRACTORS AND SUB-CONTRACTORS MUST QUOTE ON COMPLETED, FULLY
OPERABLE SYSTEMS BASED ON THE DESIGN INTENT OF THE CONTRACT
DOCUMENTS, AND ALL MATERIAL AND LABOR IMPLIED THEREFROM.
10. UNLESS OTHERWISE REQUIRED BY THE OWNER, CONSTRUCTION ADMINISTRATION
SERVICES WILL BE COMPLETED USING NEWFORMA PROJECT CENTER. REFERENCE
DIVISION 1 OF THE SPECIFICATION FOR THE PROCEDURES FOR REQUESTS FOR
INFORMATION AND SUBMITTALS.
LEGEND - GENERAL SYMBOLS
LEGEND - PARTITION INDICATIONS
LEGEND - MATERIAL INDICATIONS
LEGEND - REFLECTED CEILING
DEFINITION: THE TERM "DESIGN PROFESSIONAL" MEANS "ARCHITECT", "PROFESSIONAL
ENGINEER", "INTERIOR DESIGNER" OR OTHER PARTY RESPONSIBLE FOR PROVIDING
DESIGN SERVICES AS APPROPRIATE.
1. THE REFLECTED CEILING PLAN PROVIDES INFORMATION CONCERNING THE
LOCATIONS OF LIGHTS, CEILING FIXTURES, HVAC GRILLES, ETC. REFER TO THE
REFLECTED CEILING PLAN FOR LOCATIONS ONLY. REFER TO MECHANICAL,
ELECTRICAL, AND PLUMBING DRAWINGS FOR APPLICABLE ENGINEERING
INFORMATION.
2. SPRINKLER HEADS ARE NOT INDICATED. REFER TO PLUMBING DRAWINGS FOR
SPRINKLER REQUIREMENTS AND INFORMATION.
3. CEILING FIXTURES INCLUDING GRILLES, DIFFUSERS, INCANDESCENT LIGHTS, ETC.
ARE TO BE CENTERED IN ACOUSTIC CEILING PANELS UNLESS NOTED OTHERWISE.
4. ALL CEILING HEIGHTS NOTED ARE ABOVE FINISHED FLOOR (A.F.F.)
NOTES - REFLECTED CEILING PLAN
LEGEND - ROOF
NOTES - TOBACCO FREE WORKZONE
USE OF TOBACCO PRODUCTS IS NOT PERMITTED ANYWHERE ON OWNER'S PROPERTY.
PROHIBIT USE OF ALL TOBACCO PRODUCTS, INCLUDING BUT NOT LIMITED TO
CIGARETTES, CIGARS, PIPES, CHEWING TOBACCO, SNUFF, DIP, SNUS AND ELECTRONIC
CIGARETTES BY ALL PERSONNEL COVERED BY THIS CONTRACT WHILE ON OWNER'S
PROPERTY. THIS PROHIBITION APPLIES TO OCCUPANTS OF JOBSITE OFFICES, STORAGE
OR WORK SHEDS, WORK AREAS ASSIGNED EXCLUSIVELY TO THE CONTRACTOR, AND
VEHICLES WHILE THE VEHICLE IS ON OWNER'S PROPERTY. ENFORCE REQUIREMENTS
STRICTLY.
LVR LOUVER
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLD MOLDING
mm MILLIMETER
MO MASONRY OPENING
MT METAL THRESHOLD
MTL METAL
MULL
MULLION
MWK MILLWORK
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR
INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED OWNER
INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPP H OPPOSITE HAND
OVFL OVERFLOW
#LBS POUNDS
PAR PARALLEL
PART PARTIAL
PARTN PARTITION
PERIM PERIMETER
PERP PERPENDICULAR
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER, PLASTIC
PLBG PLUMBING
PLWD PLYWOOD
PNL PANEL
PNT PAINT
PP PITCH POCKET
PR PAIR
PRV POWERED ROOF VENTILATOR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED, PORCELAIN
TILE
PWC PLASTIC WALL COVERING
QT QUARRY TILE
QTY QUANTITY
QUAL QUALITY
R RISER
RA RETURN AIR
RAD RADIUS
RB RUBBER, RUBBER BASE
RD ROOF DRAIN
REBAR REINFORCING BAR
RECEP RECEPTACLE, RECEPTION
REF REFERENCE
REFL REFLECTED
REFR REFRIGERATOR
REG REGULAR
REINF REINFORCED
REP REPAIR
REQ REQUIRE, REQUIRED
RESIL RESILIENT
REV REVISION
RFG ROOFING
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
RT RIGHT
S SOUTH
SC SOLID CORE
SCHED SCHEDULE
SCUP SCUPPER
SD SOAP DISPENSER
SECT SECTION
SHT SHEET
SHWR SHOWER
SIM SIMILAR
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTACLE
SP STAND PIPE
SPEC SPECIFICATION
SPM SINGLE PLY MEMBRANE
SS SERVICE SINK, STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
ST STAINLESS
STL STEEL
STN STONE
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SYS SYSTEM
T TREAD
T GL TEMPERED GLASS
T&G TONGUE & GROOVE
TB TOWEL BAR
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERED, TEMPORARY
TERR TERRAZZO
THK THICK
TLT TOILET
TOC TOP OF CURB, TOP OF CONCRETE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOSL TOP OF SLAB
TTD TOILET TISSUE DISPENSER
TWS THRU-WALL SCUPPER
TYP TYPICAL
UC UNDERCOUNTER, UNDERCUT
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VB VAPOR BARRIER, VINYL BASE
VC VALVE CABINET
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VIN VINYL
VIT VITREOUS CHINA
VNR VENEER
VP VENT PIPE, VAPOR PROOF
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WIDTH
W/ WITH
W/O WITHOUT
WAINS WAINSCOT
WB WOOD BASE
WC WALL COVERING, WATER CLOSET
WD WOOD
WG WIRE GLASS
WH WATER HEATER
WIN WINDOW
WPR WATERPROOFING
WPT WORK POINT
WR WATER RESISTANT, WASTE
RECEPTACLE
WT WEIGHT
WWF WELDED WIRE FABRIC
@ AT
A/C AIR CONDITIONING
AB ANCHOR BOLT
AC ACOUSTICAL
ACP ACOUSTICAL CEILING PANEL
AD ACCESS DOOR
ADJ ADJACENT, ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
ALT ALTERNATE
AP ARMOR PLATE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AWC ACOUSTICAL WALL COVERING
BC BRICK COURSES(ING)
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BENCH MARK, BEAM
BOT BOTTOM
BRG BEARING
BRK BRICK
BSMT BASEMENT
BUR BUILT UP ROOFING
CB CATCH BASIN
CF CUBIC FOOT (FEET)
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CFM CUBIC FOOT PER MINUTE
CG CORNER GUARD
CHAN CHANNEL
CHR CHAIR RAIL
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CLG CEILING
CLO CLOSET
CLR CLEAR
cm CENTIMETER
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMP COMPOSITION, COMPOSITE
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CP CLEAR PLASTIC
CPT CARPET
CR CRASH RAIL
CR/BG CRASH RAIL / BUMPER GUARD
CT CERAMIC TILE
CTR CENTER
CV CHECK VALVE
CW CLEAR WIRE GLASS
CY CUBIC YARD
CYL CYLINDER
Ѥ CENTERLINE
D DEPTH
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DIV DIVISION
DN DOWN
DP DAMPROOFING
DR DOOR, DRAIN
DS DOWNSPOUT
DWG DRAWING
DWGS DRAWINGS
EA EACH
EB EXPANSION BOLT
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR, ELEVATION
EMER EMERGENCY
ENGR ENGINEER(ING)
EPDM ETHYLENE PROPYLENE DIENE
MONOMER (ROOF MEMBRANE)
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXPA EXPANSION ANCHOR
EXT EXTERIOR
F FAHRENHEIT
FA FIRE ALARM
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FHC FIRE HOSE CABINET
FIN FINISH(ED)
FO FINISHED OPENING
FOF FACE OF FINISH
FOS FACE OF STUD
FRTW FIRE RETARDANT TREATED WOOD
FV FIELD VERIFIED
FWC FABRIC WALL COVERING
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERAL
GL GLASS, GLAZING
GND GROUND
GNV GOOSE NECK VENTILATOR
GR GROUT
GYP GYPSUM
GYP BD GYPSUM BOARD
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HD HEAVY DUTY
HDW HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HRL HANDRAIL
HVAC HEATING VENTILATING & AIR
CONDITIONING
HWD HARDWOOD
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
IPT INTERIOR PAINT
JAN JANITOR
JCT JUNCTION
JST JOIST
JT JOINT
JT B JOINT BACKER
KB KEYBOARD
KIT KITCHEN
KO KNOCKOUT
KP KICK PLATE
KS KNEE SPACE
L LENGTH
LAM LAMINATE, LAMINATED
LAM GL LAMINATED GLASS
LAV LAVATORY
LB POUND
LBF POUNDS-FORCE
LH LEFT HAND
LIN LINEAR
LLV LONG LEG VERTICAL
LEGEND - ABBREVIATIONS
1. CONTRACTOR TO CONTACT OWNER PRIOR TO START OF DEMOLITION OF ANY AREAS
TO ALLOW OWNER TO REMOVE ANY MOVABLE EQUIPMENT SO DESIRED.
2. REMOVE ALL FIRE EXTINGUISHERS AND CABINETS IN WALLS TO BE DEMOLISHED AND
RETURN TO OWNER FOR FURTURE REUSE.
3. REPAIR HOLES IN EXISTING WALLS TO REMAIN WHERE WALL MOUNTED ITEMS ARE
TO BE REMOVED. REFER TO ROOM FINISH LEGEND FOR FINAL FINISH.
4. PATCH, FILL, AND LEVEL ALL HOLES IN FLOOR SLAB DUE TO DEMOLITION OF
PLUMBING RISERS, FLOOR DRAINS, ELECTRICAL RISERS, MILLWORK, CASEWORK, OR
EQUIPMENT.
5. REPAIR ALL CEILINGS TO MATCH EXISTING CEILINGS WHERE WALLS ARE TO BE
DEMOLISHED AND EXISTING CEILING IS TO REMAIN.
6. CONTRACTOR TO MATCH ALL EXISTING CONDITIONS FOR ALL REQUIRED
MODIFICATIONS IN RENOVATED AREAS (U.N.O.). THIS REFERS TO REPETITIONS OF
FINISH PATTERNS AND COLORS, MODIFICATIONS TO HANDRAILS AND BUMPER
PANELS, ETC.
7. WHERE PARTITIONS, EQUIPMENT, OR ACCESSORIES, ETC. ARE REMOVED AND NO
REPLACEMENT FINISH IS CALLED FOR, THE GENERAL CONTRACTOR SHALL REPAIR
TO MATCH ADJACENT FINISH.
8. CONTRACTOR TO PROTECT FROM DAMAGE ALL EXISTING FLOORS, WALLS, CEILINGS,
ETC. DURING CONSTRUCTION AND PROVIDE TEMPORARY PARTITIONS AS NEEDED.
CONTRACTOR IS RESPONSIBILE FOR REPAIR AND REPLACEMENT OF ALL DAMAGED
FLOORING, WALLS, CEILINGS, ETC. FINISHES TO MATCH EXISTING.
9. DASHED LINES INDICATE EXISTING CONSTRUCTION TO BE DEMOLISHED. TYPICAL
(U.N.O.)
10. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL
DEMOLITION MATERIALS. TEMPORARY LIGHTING WILL BE PROVIDED BY THE
CONTRACTOR.
11. REMOVE ALL FLOOR COVERINGS AND PREP CONCRETE DECK FOR NEW CARPET,
VINYL AND CERAMIC TILE AS SCHEDULED. (TYPICAL - ALL ROOMS WITHIN LIMITS OF
PROJECT)
12. REMOVE EXISTING CEILING GRID AND ASSOCIATED SUPPORT SYSTEM - RETURN
EXISTING LIGHT FIXTURES TO OWNER (TYPICAL - ALL ROOMS WITHIN LIMITS OF
PROJECT)
13. ADDITIONAL DEMOLITION MAY BE REQUIRED TO ACCOMMODATE NEW
CONSTRUCTION SHOWN ON OTHER SHEETS. CONTRACTORS TO REVIEW EXISTING
CONDITIONS AND INCLUDE IN BASE BID ALL DEMOLITION REQUIRED FOR A
COMPLETE INSTALLATION.
14. REMOVE ALL EXISTING BASES AND VINYL WALL COVERINGS. PREPARE SURFACES
TO ACCEPT NEW FINISHES, TYP.
NOTES - GENERAL DEMOLITION
NOTES - PATCH & REPAIR
1. FILL ALL HOLES IN FLOOR SLAB WITH CONCRETE AFTER REMOVAL OF PLUMBING
LINES, DRAINS, PIPES, ETC. MAINTAIN REQUIRED FIRE RATINGS.
2. PATCH AND REPAIR HOLES IN EXISTING GYP BD PARTITIONS FROM REMOVED
EQUIPMENT, MECHANICAL AND ELECTRICAL DEVICES AND OUTLETS, ATTACHMENTS,
FURNISHINGS, ETC.
3. PATCH AND REPAIR ALL CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW
MECHANICAL AND ELECTRICAL WORK. THIS WORK MAY EXTEND BEYOND
BOUNDARIES INDICATING "PROJECT LIMITS" ON ARCHITECTURAL DRAWINGS.
FINISHES SHALL MATCH EXISTING, OR PROVIDE NEW AS SCHEDULED.
4. PATCH AND REPAIR ALL EXISTING FIREPROOFING DISTURBED DURING DEMOLITION
AT COLUMNS AND BRACING TO MEET REQUIRED FIRE RATINGS.
5. PATCH AND REPAIR FINISHES WHERE EXISTING WALLS, PARTITIONS, DOORS,
PLUMBING FIXTURES, OR CASEWORK HAVE BEEN REMOVED. FINISHES SHALL
MATCH EXISTING, OR PROVIDE NEW AS SCHEDULED.
LEGEND - DRAWING NUMBERS
LEGEND - TYPICAL COUNTER HEIGHTS
10/17/2016
04/06/17