HomeMy WebLinkAboutB16-0266_A002_1491490867.pdfCLEAR FLOOR SPACE - RECTANGLE 30"x48" TURNING SPACE - CIRCULAR TURNING SPACE - T-SHAPED 5'-0" x > 24" ALCOVE CLEAR SPACE (FORWARD APPROACH) - RECTANGLE 36"x48" ALCOVE CLEAR SPACE (PARALLEL APPROACH) - RECTANGLE 30"x60" x > 15" ACCESSIBLE TURNING SPACE & CLEAR SPACE 5'-0" 2'-0" 1'-0" 3'-0" 1'-0" 5'-0" 3'-0" 4'-0" 2'-6" 4'-0" 3'-0" 2'-6" 5'-0" FRONT APPROACH POCKET OR HINGE APPROACH SIDE APPROACH STOP OR LATCH APPROACH DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS 3'-6" 3'-6" 3'-6" 4'-0" 2'-0" 1'-10" FRONT APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE FRONT APPROACH, PUSH SIDE (WITH CLOSER & LATCH) HINGE APPROACH, PULL SIDE (OPTION A) HINGE APPROACH, PULL SIDE (OPTION B) HINGE APPROACH, PUSH SIDE HINGE APPROACH, PUSH SIDE (WITH CLOSER & LATCH) LATCH APPROACH, PULL SIDE (WITH CLOSER) LATCH APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE (WITH CLOSER) 32" MIN. FRONT APPROACH: HINGE APPROACH: LATCH APPROACH: LATCH APPROACH, PULL SIDE MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS & GATES 5'-0" 1'-6" 4'-0" 4'-0" 1'-0" 5'-0" 3'-0" 4'-6" 3'-6" 3'-6" 1'-10" 4'-0" 1'-0" 1'-10" 4'-0" 2'-0" 4'-6" 2'-0" 2'-0" 3'-6" 2'-0" 4'-0" 34" - 38" 34" - 38" 4'-0" MAX. 1'-3" MIN. 4'-0" MAX. 3'-8" MAX. 4'-0" MAX. 4'-0" MAX. 3'-10" MAX. 2'-10" MAX. 2'-10" MAX. 1'-3" MIN. UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH SIDE REACH HANDRAIL HEIGHT AT STAIRS HANDRAIL HEIGHT AT RAMPS X = TREAD DEPTH TOP HANDRAIL EXTENSION AT STAIRS BOTTOM HANDRAIL EXTENSION AT STAIRS TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS X X 1'-0" MIN. 1'-0" MIN. 1'-0" MIN. 1'-8" MAX 2'-1" MAX 2'-3" MAX. 6'-8" MIN. REDUCED VERTICAL CLEARANCE 10" MAX. 10" MAX. 2'-0" MAX. CARPET ON FLOOR SURFACES VERTICAL CHANGES IN LEVEL (a) BEVELED CHANGES IN LEVEL (b) BEVELED CHANGES IN LEVEL 1 2 1 2 1/2" 1/4" MAX. 1/4" - 1/2" MAX. 1/2" 1/4" 1/4" CLR. 34" 27" AFF MAX TO BOT OF REFLECTING SURFACE OF MIRROR CLR 27"34" MAX. AFF MAX TO BOT OF REFLECTING SURFACE OF MIRROR MIN. 8" 27" MIN. MIN. 9" MAX. 6" MIN. 11" EMPLOYEE RESTROOM LAVATORY PUBLIC RESTROOM LAVATORY KNEE & TOE CLEARANCE AT LAVATORY ACCESSIBLE WATER CLOSET ACCESSIBLE WATER CLOSET ACCESSIBLE URINAL STANDARD URINAL DRINKING FOUNTAIN MAX. 12" 42" MIN. 40"40" 15" MIN. 7" - 9" 33" - 36" 39" - 41" 18" MIN. 39" - 41" 17" - 19" 18" MIN. 39" - 41" 33" - 36" 16" - 18" 36" 12" 24" 44" AFF MAX. 17" MAX. MIN. 13 1/2" EQ EQ EQ EQ 24" 30" CLR MIN. 38" - 43" SPOUT HT. 16" 27" 31" 36" SPOUT HT. 48" MAX. DOOR OPERATED PUSH-BUTTON 54" MIN. TOILET ACCESSORY# 48" MAX TA-1 TA-2 TA-3 TA-4 TA-5 TA-6 TA-7 TA-8 TA-9 TA-10 TA-11 TA-12 TA-13 TA-14 ILLUSTRATION: ACCESSORY ITEM: RESPONSIBILITY: BLOCKING TYPE: GRAB BAR - 18" -- C2 GRAB BAR - 42" -- C2 GRAB BAR - 36" -- C2 SEAT COVER DISPENSER -- A1 WALL MOUNTED SOAP DISPENSER -- A1 MIRROR -- C1 HOOK -- C1 (OR DOOR MOUNTED) WALL BUMP -- A1 PAPER TOWEL DISPENSER -- A1 COMBINATION PAPER TOWEL DISPENSER -- A2 SANITARY NAPKIN DISPOSAL UNIT -- A1 BABY CHANGING STATION -- C2 TOILET TISSUE DISPENSER -- C1 VENDOR -- A1 SEAT COVER SURFACE COIN SLOT NOTE: EQUIPMENT INDICATED IN DIAGRAM MAY OR MAY NOT BE USED ON THIS PROJECT. REFER TO EQUIPMENT PLAN(S), INTERIOR ELEVATIONS, ETC. FOR LOCATION AND QUANTITIES OF ITEMS. CONFIRM WITH OWNER ALL REQUIREMENTS FOR OWNER FURNISHED, CONTRACTOR INSTALLED (OFCI) ITEMS. MANUFACTURER: -- -- -- -- -- -- -- -- -- -- -- -- -- --39" - 41" MIN 18" 42" 36" MAX 33" MIN 36" 36" MAX 33" MIN 48" MAX 38" MAX 38" MAX 36" 48" MAX 48" MAX 11" 30" 48" MAX MIN 19" 48" MAX MODEL NUMBER: -- -- -- -- -- -- -- -- -- -- -- -- -- -- TA-15 AIR BLADE -- A1 -- --41" MAX 34" MAX 27" MIN 2 1/2" MAX. 18" MIN. 20" - 24" 2" MAX. 17" - 19" BENCH BACK SUPPORT AND SEAT HEIGHT 12" BACK OF WALL 42" MIN. 12" DRESSING ROOM BENCH WITH BACK 42" MIN. 20" - 24" DRESSING ROOM BENCH WITHOUT BACK 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2014 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 8/29/2016 4:05:55 PM GENERAL ACCESSIBILITY STANDARDS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A002 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOTES - GENERAL ACCESSIBILITY BUILDING AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE ACCESSIBLE IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE AND 2009 ICC A117.1. DEFINITIONS: ACCESSIBLE: A SITE, BUILDING, FACILITY OR PORTION THEREOF THAT COMPLIES WITH THE REFERENCED CODES. ACCESSIBLE ROUTE: A CONTINUOUS, UNOBSTRUCTED PATH THAT COMPLIES WITH THE CODES. CIRCULATION PATH: AN EXTERIOR OR INTERIOR WAY OF PASSAGE FROM ONE PLACE TO ANOTHER FOR PEDESTRIANS. COMMON USE: INTERIOR OR EXTERIOR CIRCULATION PATHS, ROOMS, SPACES OR ELEMENTS THAT ARE NOT FOR PUBLIC USE AND ARE MADE AVAILABLE FOR THE SHARED USE OF TWO OR MORE PEOPLE. EMPLOYEE WORK AREA: ALL OR ANY PORTION OF ASPACE USED ONLY BY EMPLOYEES AND ONLY FOR WORK. CORRIDORS, TOILET ROOMS, KITCHENETTES AND BREAK ROOMS ARE NOT EMPLOYEE WORK AREAS. FACILITY: ALL OR ANY PORTION OF BULIDINGS, STRUCTURES, SITE IMPROVEMENTS, ELEMENTS AND PEDESTRIAN OR VEHICULAR ROUTES LOCATED ON THE SITE. PUBLIC ENTRANCE: AN ENTRANCE THAT IS NOT A SERVICE ENTRANCE OR A RESTRICTED ENTRANCE. PUBLIC-USE AREAS: INTERIOR OR EXTERIOR ROOMS OR SPACES THAT ARE MADE AVAILABLE TO THE GENERAL PUBLIC. RESTRICTED ENTRANCE: AN ENTRANCE THAT IS MADE AVAILABLE FOR COMMON USE ON A CONTROLLED BASIS, BUT NOT PUBLIC USE, AND THAT IS NOT A SERVICE ENTRANCE. SERVICE ENTRANCE: AN ENTRANCE INTENDED PRIMARILY FOR DELIVERY OF GOODS OR SERVICES. SITE: A PARCEL OF LAND BOUNDED BY A LOT LINE OR A DESIGNATED PORTION OF A PUBLIC RIGHT-OF-WAY WHEELCHAIR SPACE: A SPACE FOR A SINGLE WHEELCHAIR AND ITS OCCUPANT. SCOPING REQUIREMENTS: SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES, TEMPORARY OR PERMANENT, SHALL BE ACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES. SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES SHALL BE EXEMPT FROM THESE REQUIREMENTS TO THE EXTENT SPECIFIED BELOW AND IN OTHER SECTIONS OF THE AFORE REFERENCED ACCESSIBILITY CODES. ACCESSIBILITY IS NOT REQUIRED IN BUILDINGS AND FACILITIES, OR PORTIONS THEREOF, TO THE EXTENT PERMITTED BY 2012 VCC SECTIONS 1104 THROUGH 1110. EXISTING BUILDINGS SHALL COMPLY WITH 2012 VIRGINIA REHABILITATION CODE SECTION 3409. SECTION 1103.2.3 - EMPLOYEE WORK AREAS: SPACES AND ELEMENTS WITHIN EMPLOYEE WORK AREAS SHALL ONLY BE REQUIRED TO COMPLY WITH SECTIONS 907.5.2.3.2, 1107 AND 1104.3.1 AND SHALL BE DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH DISABILITIES CAN APPROACH, ENTER AND EXIT THE WORK AREA. WORK AREAS OR PORTIONS OF WORK AREAS, THAT ARE LESS THAN 150 SQUARE FEET IN AREA AND ELEVATED 7 INCHES OR MORE ABOVE THE GROUND OR FINISHED FLOOR WHERE THE ELEVATION IS ESSENTIAL TO THE FUNCTION OF THE SPACE SHALL BE EXEMPT FROM ALL REQUIREMENTS. SECTION 1103.2.8 - LIMITED ACCESS SPACES: NONOCCUPIABLE SPACES ACCESSED ONLY BY LADDERS, CATWALKS, CRAWL SPACES, FREIGHT ELEVATORS OR VERY NARROW PASSAGEWAYS ARE NOT REQUIRED TO BE ACCESSIBLE. SECTION 1103.2.9 - EQUIPMENT SPACES: SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE, REPAIR OR MONITORING OF EQUIPMENT ARE NOT REQUIRED TO BE ACCESSIBLE. SUCH SPACES INCLUDE, BUT ARE NOT LIMITED TO , ELEVATOR PITS, ELEVATOR PENTHOUSES, MECHANICAL, ELECTRICAL OR COMMUNICATIONS EQUIPMENT ROOMS, PIPING OR EQUIPMENT CATWALKS, WATER OR SEWAGE TREATMENT PUMP ROOMS AND STATIONS, ELECTRIC SUBSTATIONS AND TRANSFORMER VAULTS, AND HIGHWAY AND TUNNEL UTILITY FACILITIES. SECTION 907.5.2.3.2 - EMPLOYEE WORK AREAS (REFERENCED ABOVE): WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE NOTIFICATION APPLIANCE CIRCUITS SERVING THE EMPLOYEE WORK AREAS SHALL BE INITIALLY DESIGNED WITH A MINIMUM OF 20 PERCENT SPARE CAPACITY TO ACCOUNT FOR THE POTENTIAL OF ADDING VISIBLE NOTIFICATION APPLIANCES IN THE FUTURE TO ACCOMMODATE HEARING IMPAIRED EMPLOYEES. SECTION 1007 - ACCESSIBLE MEANS OF EGRESS (REFERENCED ABOVE): ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS. SECTION 1104.3.1 - EMPLOYEE WORK AREAS (REFERENCED ABOVE): COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS SHALL BE ACCESSIBLE ROUTES EXCEPTIONS: 1. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE WORK AREAS THAT ARE LESS THAN 300 SQUARE FEET IN SIZE AND DEFINED BY PERMANENTLY INSTALLED PARTITIONS, COUNTERS, CASEWORK OR FURNISHINGS, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. 2. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE USE AREAS, THAT ARE AN INTEGRAL COMPONENT OF EQUIPMENT, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. 3. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EXTERIOR EMPLOYEE WORK AREAS THAT ARE FULLY EXPOSED TO THE WEATHER, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. SECTION 1105 - ACCESSIBLE ENTRANCES: AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL BE ACCESSIBLE. EXCEPTIONS: 1. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO AREAS NOT REQUIRED TO BE ACCESSIBLE. 2. LOADING AND SERVICE ENTRANCES THAT ARE NOT THE ONLY ENTRANCE TO A TENANT SPACE. WHERE RESTRICTED ENTRANCES ARE PROVIDED TO A BUILDING OR FACILITY, AT LEAST ONE RESTRICTED ENTRANCE TO THE BUILDING OR FACILITY SHALL BE ACCESSIBLE. IF A SERVICE ENTRANCE IS THE ONLY ENTRANCE TO A BUILDING OR A TENANT SPACE IN A FACILITY, THAT ENTRANCE SHALL BE ACCESSIBLE. AT LEAST ONE ACCESSIBLE ENTRANCE SHALL BE PROVIDED TO EACH TENANT IN A FACILITY. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO TENANTS THAT ARE NOT REQUIRED TO BE ACCESSIBLE. SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES WHERE PARKING IS PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN COMPLIANCE WITH REFERENCED CODE SECTIONS AND TABLES. TEN PERCENT OF PATIENT AND VISITOR PARKING SPACES PROVIDED TO SERVE HOSPITAL OUTPATIENT FACILITIES SHALL BE ACCESSIBLE. FOR EVERY SIX OR A FRACTION OF SIX ACCESSIBLE SPACES, AT LEAST ONE SHALL BE A VAN-ACCESSIBLE PARKING SPACE. NOTHING IN THE REFERENCED STANDARDS IS INTENDED TO PREVENT THE USE OF DESIGNS, PRODUCTS, OR TECHNOLOGIES AS ALTERNATIVES TO THOSE PRESCRIBED PROVIDED THEY RESULT IN EQUIVALENT OR GREATER ACCESSIBILITY AND SUCH EQUIVALENCY IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. THE AUTHORITY HAVING JURISDICTION SHALL PROVIDE AN APPROPRIATE REVIEW AND APPROVAL PROCESS TO ENSURE COMPLIANCE WITH ADOPTED STANDARDS. ADAAG AND ICC A117.1 ARE SUBJECT TO VARIOUS AND POSSIBLE CONTRADICTORY INTERPRETATIONS. THE ARCHITECT, THEREFORE, WILL USE REASONABLE PROFESSIONAL EFFORTS AND JUDGEMENTS TO INTERPRET APPLICABLE ACCESSIBILITY REQUIREMENTS AS THEY PERTAIN TO PHYSICAL BARRIERS AND AS THEY APPLY TO THE PROJECT. THE ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT THE PROJECT WILL COMPLY WITH ALL INTERPRETATIONS OF SUCH ACCESSIBILITY REQUIREMENTS AND/OR THE REQUIREMENTS OF OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND REGULATIONS THAT APPLY TO THE PROJECT. SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES STANDARDS - ACCESSIBLE CLEAR SPACE AND MANEUVERING CLEARANCES STANDARDS - FLOOR SURFACES STANDARDS - ACCESSIBLITY DIAGRAMS STANDARDS - TOILET ACCESSORY MOUNTING DIAGRAMS STANDARDS - TOILET FIXTURE MOUNTING DIAGRAMS STANDARDS - DRESSING ROOM CLEARANCES 04/06/17